MANUAL
CONGRATULATIONS
on the purchase of your new CTEK professional battery management unit. This unit is part of a range of professional battery chargers from CTEK SWEDEN AB. It represents the latest technology in battery charging. Using the CTEK D250S DUAL and SMARTPASS products, you can maximize the performance of your 12VDC source.
SAFETY
•The unit is designed for 12V lead-acid batteries. Do not use the unit for any other batteries.
•Use safety glasses when connecting or disconnecting a battery.
•Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes. Seek medical advice.
•Make sure that the cables are not being pinched and are not in contact with warm surfaces or sharp edges.
•While charging, a battery can emit explosive gases; avoid sparks in the immediate area.
•Always provide for proper ventilation during charging.
•Avoid covering the unit.
•D250S DUAL is not reverse polarity protected.
•Disconnect battery poles before installation
All installations on boats must follow ISO 10133. Please note!
1.Connections from the battery must be fused close to the battery.
2.Batteries must be permanently mounted in ventilated areas.
3.Cables must be placed in tubes, separated from cables for 230V (shore power), or be attach to the surface every 300mm.
4.Cables in the engine room must be rated to withstand 700C
D250S DUAL
The D250S Dual has 2 inputs. The Service battery will be charged from the alternator, solar panel, or both in combination. The solar panel adjusts itself to the Starter battery voltage. The Starter battery will be charged and maintained directly by the solar panel if the Service battery is fully charged.
D250S Dual |
<![if ! IE]> <![endif]>EN |
|
features:
•Multi-step 20A temperature compensated battery charging and battery maintenance.
•Battery separation of Starter and Service batteries.
•Maximum power point tracking for solar panels charging the Service battery.
•Two power source inputs (alternator, solar, wind, Supply battery and other).
•Coordination of the two inputs, allowing parallel operation.
•The auxiliary input will also charge and maintain the Starter battery.
Solar panel + Vehicle ground/Solar panel –
Temperature sensor L:2m
+IN
|
12V |
+IN |
D250S DUAL |
+OUT |
Alternator battery + Service battery +
EN • 3
|
|
|
|
|
|
D250S DUAL Lamp INDICATION DURING NORMAL OPERATION |
||||||
DEFINITIONS SOLAR PANEL |
|
DEFINITIONS Alternator battery |
||||||||||
|
|
|
|
|
|
|
|
|
||||
Depending on the application, it could also |
|
Depending on the application, it could also |
|
|
|
|
|
Lit with a steady glow |
|
|||
be referred to as |
|
be referred to as |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
- PV panel |
|
- Starter battery |
|
|
|
|
|
|
|
Service battery charged by the alternator |
||
- Photovoltaic panel |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CONNECTIONS |
|
CONNECTIONS |
|
|
|
|
|
|
|
Service battery charged by the solar panel |
||
- Solar panel |
|
- Trailer coupling |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Service battery charged by both the alternator and solar |
||||
- Wind power |
|
- Alternator |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
panel |
|
|||
|
|
- SMARTPASS Alternator + |
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
Service battery fully charged. Alternator battery maintained |
||||
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
by the solar panel |
|
|
DEFINITIONS SERVICE BATTERY |
|
D250S DUAL LampS |
|
|
D250S DUAL Lamp Error INDICATION |
|
||||||
Depending on the application, it could also |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
be referred to as |
|
1 |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
- House battery |
|
|
|
|
|
|
|
|
|
|
Explanation |
Recommendation |
- Domestic battery |
|
|
|
|
|
|
|
|
|
|
|
|
- Consumer battery |
|
|
|
|
|
|
|
|
|
|
High temperature |
Consider relocationg unit |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|||
CONNECTIONS |
|
2 |
4 |
5 |
|
|
|
|
|
|
detected at either unit or |
and/or service battery |
|
|
|
|
|
|
|
service battery |
|
||||
|
|
|
|
|
|
|
|
|||||
- Electrical equipment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Service battery connec- |
Check Service battery |
|
- Battery bank |
|
|
|
|
|
|
|
|
|
|
||
- SMARTPASS service battery + |
|
1. Error lamp |
4. Alternator |
|
|
|
|
|
|
tion problem detected |
connection and fuse |
|
|
|
|
|
|
|
|
||||||
|
|
2. Power lamp |
battery lamp |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
3. Solar power |
5. Service bat- |
|
|
|
|
|
|
Service battery connec- |
Check Service battery |
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|||||
|
|
lamp |
tery lamp |
|
|
|
|
|
|
tion problem detected |
connection and fuse |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
D250S DUAL Lamp FUNCTION |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Service battery connec- |
Check Service battery |
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
tion problem detected |
connection and fuse |
|
|
|
|
|
LAMP |
Function |
|
Power lamp |
D250S DUAL connected correctly, ready to use |
Steady lamp |
|
|
|
Alternator battery lamp |
Alternator running |
Flashing lamp |
|
|
|
Service battery lamp |
Charging of Service battery |
|
Solar panel lamp |
Solar panel in operation |
|
4 • EN |
|
|
SMARTPASS
SmartPass can operate as a stand-alone unit, but works best in combination with D250S Dual. The SmartPass creates a priority path for charging the Service battery to recharge it more quickly and efficiently. Attached energy sources like solar, wind or shore power will charge both the Service and the Starter batteries through the SmartPass. Service batteries that are overheated due to age, high ambient temperature or other battery problems will be protected from high alternator current.
SMARTPASS
fEATURES:
The CTEK SmartPass adds additional functionality for higher output alternators, larger battery banks and/or high parallel loads.
•Separation of consumers and Service batteries during charging, which improves the charging capacity significantly, and lowers the consumer voltage, which increases expected service life of lights and other electronics.
•Service battery watch, which avoids harmful deep discharges that otherwise would shorten battery life. The battery watch also protects navigation, radio and emergency light from being out of electricity.
•Over-temperature protection of Service battery. High battery temperature could significantly reduce battery life.
•Maintenance charge of Starter battery, which simplifies installation with fewer components. •Simplified installation of AC/DC chargers (shore power). Only one output from the AC/DC charger needed.
Alternator battery + |
Service battery + |
Negative cable connection M8
L:0.3m
+IN |
+OUT |
12V SMARTPASS
+OUT
Temperature sensor L:2m
Consumers +
DEFINITIONS Alternator battery
Depending on the application, it could also be referred to as
- Starter battery
CONNECTIONS
-Trailer coupling
-Solar panel
-Wind power
-Alternator
-D250S DUAL Alternator battery +
DEFINITIONS CONSUMERS
Depending on the application, it could also be referred to as
-Electrical equipment +
CONNECTIONS
-Electrical equipment
DEFINITIONS SERVICE BATTERY
Depending on the application, it could also be referred to as
-House battery
-Domestic battery
-Consumer battery
CONNECTIONS |
|
<![if ! IE]> <![endif]>EN |
|
|
|
|
|
- Electrical equipment |
|
||
|
|
||
- Battery bank |
|
|
|
- D250S DUAL Service battery + |
|||
|
|
||
|
|
||
SMARTPASS LampS |
|
||
1 |
|
3 |
|
|
|
|
|
|
|
5 |
|
2 |
4 |
6 |
|
1. Error lamp |
|
5. Alternator |
|
2. Power lamp |
battery charg- |
|
|
3. Service bat- |
ing lamp |
|
|
tery charging |
6. Service bat- |
|
|
lamp |
|
tery consump- |
|
4. Alternator |
|
tion lamp |
|
battery |
|
|
|
consumption |
|
|
|
lamp |
|
|
|
|
|
|
|
The CTEK SmartPass is designed to work together with 1-2 CTEK D250S Dual, but can also be used alone.
EN • 5
SMARTPASS Lamp FUNCTION
|
Lamp |
Steady |
Flashing |
|
|
Power lamp |
Unit ready to use |
|
|
|
Alternator battery con- |
|
|
|
2 |
Engine running |
Too high current through |
||
sumption lamp |
relay |
|||
|
|
|||
1 |
Service battery charging |
Charging Service battery |
|
|
lamp |
|
|||
|
|
|
||
4 |
Service battery consump- |
Consumers powered by |
Too high current through |
|
tion lamp |
Service battery |
relay |
||
|
||||
3 |
Alternator battery char- |
Alternator battery |
Too high current through |
|
maintained by Service |
||||
ging lamp |
relay |
|||
|
battery |
|||
|
|
|
SMARTPASS Lamp INDICATION DURING NORMAL OPERATION
2 |
1 |
4 |
3 |
Explanation |
|
|
|
|
|
High current from alternator to service battery. Consumer powered by alternator
Reduced current from alternator to service battery.
Consumer powered by alternator
Consumer powered by alternator. Battery charged by
D250S Dual charger
Pulse maintenance of starter battery
SMARTPASS Lamp ERROR INDICATION |
|
|
|||||||||||
Steady lamp |
|
|
|
|
|
Flashing lamp |
|
|
|||||
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
1 |
4 |
|
3 |
|
Explanation |
Recommendation |
||||
|
|
|
|
|
|
|
|
|
|
|
|
Service battery overheated |
Check condition |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
and/or installation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Too high current through or temperature at internal relay. Too high |
Check service battery. Reduce alternator size or add one more D250S |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Service battery charge current. |
DUAL in parallel. Service battery bank too deeply discharged. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Too high current through or temperature at internal relay. Too many |
Consider relocation of unit. Reduce power usage. |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
consumers connected at the same time. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Too high current through or temperature at internal relay. Too high cur- |
Starter battery problems, check battery. |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
rent to starter battery. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Too high current through or temperature at internal relay. Too many |
Relocate unit or reduce concurrent use of consumers. |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
consumers connected. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Battery watch activated. Service battery too low |
Recharge Service battery |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 • EN