Crown CTS-8200 Brochure

CTs MULTICHANNEL SERIES
CTs 8200
Architectural & Engineering Specifi cations
CTs 8200 (120 V, 60 Hz models)
The power amplifi er shall be a solid-state eight-channel model employ­ing Multi-Mode
The amplifi er shall contain protection from shorted, open and mis­matched loads, general overheating, DC, high-frequency overloads, under/over voltage, and internal faults.
The amplifi er shall contain FIT (Fault Isolation Topology), which isolates channel-specifi c faults and prevents them from affecting remaining channels.
If an amplifi er channel starts to overheat, the Thermal Level Control (TLC) circuit shall engage that channel’s input compressor in an amount proportional to the amount of overheating, in order to generate less heat. If the channel becomes too hot for safe operation, the channel shall shut off, and the Thermal Indicator for that channel shall fl ash brightly to alert the user that a state of thermal stress or overload has caused the channel to shut down.
The front-panel control shall be a power switch. Rear-mounted controls shall include Channel Level Controls and a Mode
Switch. The Mode Switch (used on each consecutive pair of channels) is a four-position switch which selects among Dual 8/4 ohms, Dual 70V, Bridge-Mono 16/8 ohms, and Bridge-Mono 100V.
The recommended load impedance in Dual mode shall be 4/8 and 25 ohms (70V). The load impedance in Bridge-Mono mode shall be 8/16 ohms and 50 ohms (100V). The amplifi er shall be safe when driving any kind of load, including highly reactive ones.
Rear-mounted output connectors shall be one four-pole terminal strip for every two channels with a touch-proof cover. Rear-mounted input connectors shall be removable Phoenix-style barrier connectors for balanced input.
The amplifi er shall be fully compatible with and shall provide appropriate input cables and connectors for Crown® VCA-MC8 module.
Front panel indicators shall include a yellow Bridge-Mode Indicator (one per channel pair) that illuminates when the channel pair’s Mode Switch is set to the “Bridge” position (and fl ashes if the Mode Switch is changed while the amplifi er is powered up, indicating that the amplifi er must be powered off and on to reset the Mode), a green Ready Indicator (one per channel) that illuminates when the channel is initialized and ready to produce audio output, a green Signal Indicator (one per chan­nel) that illuminates to indicate the presence of input signals above –40 dBu, a red Clip Indicator that illuminates when the THD of the channel’s output signal rises to a level typically considered as the onset of audible clipping (and illuminates during Thermal Level Control or input overload), a red Thermal Indicator (one per channel) that fl ashes when a state of thermal stress or overload has caused the channel to shut down (and fl ashes in all channels if the power supply goes into thermal overload), a red Fault Indicator (one per channel) that fl ashes when a fault condition has occurred in the channel, and a blue Power Indicator that illuminates when the amplifi er has been turned on and AC power is available (and illuminates when the amplifi er shuts off due to an under­/over-voltage condition on the AC mains).
®
(AB+B) output circuitry.
The power amplifi er shall meet or exceed the following performance crite­ria. Input sensitivity for rated output: 1.4 V. Rated output with eight chan­nels driven in Dual mode with 0.1% THD (20 Hz to 20 kHz): 175 watts per channel into 4 ohms; 155 watts per channel into 8 ohms, and 185 watts per channel (70V). Rated output in Bridge-Mono mode with four channel pairs driven at 0.1% THD (20 Hz to 20 kHz): 350 watts per channel pair into 8 ohms; 310 watts per channel pair into 16 ohms, and 185 watts per channel pair (100V). Signal to Noise Ratio below rated power (20 Hz to 20 kHz): 100 dB unweighted. Phase Response: ±35 degrees from 10 Hz to 20 kHz at 1 watt. Frequency Response: 20 Hz to 20 kHz, ±0.5 dB at 1 watt into 8 ohms per channel in Dual mode. Damping Factor: greater than 180 from 10 to 400 Hz. Crosstalk (below rated power, 20 Hz to 1 kHz): greater than 80 dB. Intermodulation Distortion (60 Hz and 7 kHz at 4:1, from 163 mil­liwatts to full bandwidth power): less than 0.05% typical. Total Harmonic Distortion at 1 watt from 20 Hz to 20 kHz: less than 0.05%. Common Mode Rejection (20 Hz to 1 kHz): greater than 50 dB. DC Output Offset (shorted input): less than 5 mV. Maximum Input Level (before input compression): + 22 dBu rms. Power Draw at Idle (120 VAC mains, all channels in 4/8 ohm mode): 58 watts. Power Draw at Idle (120 VAC mains, all channels in 70V mode): 77 watts.
The amplifi er chassis shall be constructed of steel with a durable black fi nish and shall be designed for continuously variable-speed forced-air ventilation from the front panel to the back panel.
The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA standard (RS-310-B) rack mounting. The amplifi er shall be 5.25 inches (13.3 cm) tall, and 16.25 inches (41.3 cm) deep behind the rack-mounting surface.
The amplifi er shall weigh 36 pounds, 6 ounces (16.5 kg). The amplifi er shall be designated the Crown CTs 8200.