The above sink Boiling Water Unit dispenses boiling water — Please treat it with care.
If a tundish is used it must be placed above the sink in the open.
IMPORTANT: THIS UNIT MUST BE INSTALLED BY AN AUTHORISED PLUMBER.
WARNING:
WE RECOMMEND A BACKFLOW PREVENTION DEVICE COMPLYING WITH THE REQUIREMENT OF A.S. 3500.1 BE
INSTALLED ON THE WATER SUPPLY INLET TO THIS UNIT.
*Unit to be connected in accordance with A.S.3500 & A.S.3000
PROUDLY MADE IN AUSTRALIA
Boiling Water Units
30, 40, 50 & 60 litres
Wall Mounted
Oponal Stainless Steel Cover
Simple service if required
No costly parts
1 year warranty
Energy ecient
Standard colour bond nish
OPERATING & INSTALLATION INSTRUCTIONS
CELSIUS 100 ABOVE SINK BOILING WATER UNIT. Series JE

CELSIUS 100 BOILING WATER UNIT SPECIFICATIONS JE SERIES
CELSIUS 100 ABOVE SINK BOILING
WATER UNIT JE SERIES
Model No Capacity
(Litres)
No. of Cups/Hr Cup/Hr
Recovery
Rating KW Height mm Width mm Depth mm
CRN30 30 150 160 3.0 635 600 250
CRN40 40 200 200 4.8 775 600 250
CRN50 50 250 200/260 4.8/6.0 775 600 250
CRN60 60 300 200/260 4.8/6.0 840 600 250
DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE
TAP, POWER MUST BE OFF UNTIL INSTALLATION IS COMPLETE.
This unit is ed with a computerised element and boil dry protecon.
Maximum inlet pressure 820 kpa. Fit PLV if required.
Minimum inlet pressure 200 kpa. If a lower pressure is encountered refer to
manufacturer.
DO NOT PLUG IN. POWER MUST BE OFF UNTIL INSTALLATION IS
COMPLETE
PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER.