All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Corsair CV650 (Mauna Loa)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency83.932
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V55.120
Average Efficiency 5VSB79.778
Standby Power Consumption (W) -115V0.0441618
Standby Power Consumption (W) -230V0.0951518
Average PF0.988
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output31.67
Efficiency Rating (ETA)ETA-S
Noise Rating (LAMBDA)LAMBDA-S++
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY GRAPH
Corsair CV650 (Mauna Loa)
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.231
1
5.113V0.314115.15V
0.090A0.461
2
5.112V0.596115.15V
0.550A2.808
3
5.103V3.476115.15V
1.000A5.096
4
5.094V6.290115.16V
1.500A7.629
5
5.085V9.475115.15V
DC/AC
(Watts)
EfficiencyPF/AC Volts
73.567%
77.349%
80.783%
81.017%
80.517%
0.038
0.071
0.280
0.358
0.400
Corsair CV650 (Mauna Loa)
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.045A0.230
1
5.112V0.367230.39V
0.090A0.460
2
5.111V0.656230.39V
0.550A2.807
3
5.103V3.594230.37V
1.000A5.095
4
5.094V6.381230.38V
1.500A7.629
5
5.085V9.573230.38V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.013
62.670%
0.024
70.122%
0.121
78.102%
0.191
79.846%
0.248
79.693%
6
3.000A15.173
5.057V19.677115.15V
VAMPIRE POWER -115V
77.110%
0.457
6
3.000A15.169
79.938%
5.056V18.976230.39V
0.336
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Corsair CV650 (Mauna Loa)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
3.543A1.968A1.973A0.984A64.835
12.206V5.078V3.342V5.083V82.15239.50°C115.14V
8.080A2.964A2.968A1.184A129.354
12.184V5.063V3.336V5.067V152.73240.17°C115.14V
13.037A3.466A3.453A1.386A194.466
12.155V5.049V3.330V5.053V225.25541.39°C115.13V
18.026A3.974A3.969A1.588A259.704
12.121V5.036V3.325V5.038V299.63042.47°C115.13V
22.700A4.985A4.972A1.793A325.008
12.092V5.019V3.318V5.021V376.14243.72°C115.13V
DC/AC
(Watts)
Corsair CV650 (Mauna Loa)
Fan
Efficiency
78.921%69516.6
84.693%72316.9
86.331%82120.3
86.675%97423.8
86.406%114828.5
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
35.49°C0.970
35.81°C0.975
36.64°C0.982
36.77°C0.988
37.41°C0.991
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
27.322A5.997A5.979A1.999A389.532
85.853%131632.6
12.068V5.003V3.312V5.005V453.72145.20°C115.13V
32.027A7.020A6.990A2.206A454.865
85.088%147435.1
12.045V4.985V3.305V4.988V534.57946.63°C115.12V
36.731A8.054A8.005A2.415A520.172
84.185%162837.8
12.027V4.967V3.298V4.970V617.88847.73°C115.12V
41.873A8.581A8.504A2.421A585.109
83.223%179840.3
12.003V4.954V3.292V4.957V703.05848.81°C115.13V
46.749A9.115A9.039A3.042A649.962
82.026%192542.7
11.984V4.938V3.286V4.934V792.39050.26°C115.15V
52.224A9.134A9.056A3.049A714.789
80.864%200042.8
11.969V4.927V3.281V4.921V883.93551.13°C115.13V
0.151A16.000A16.000A0.000A134.511
78.260%104328.4
12.176V4.975V3.317V5.052V171.87844.80°C115.16V
52.020A1.002A0.999A1.000A637.083
83.071%191942.6
11.991V5.004V3.304V4.997V766.91050.83°C115.15V
38.15°C0.993
38.59°C0.994
39.01°C0.995
39.45°C0.995
40.15°C0.995
40.57°C0.995
38.52°C0.977
40.91°C0.996
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
Anex
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)14.30
AC Loss to PWR_OK Hold Up Time (ms)12.10
PWR_OK Inactive to DC Loss Delay (ms)2.20
Corsair CV650 (Mauna Loa)
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS