Conceptronic CB100S24S, CB100S48S Quick Installation Manual

NEDERLANDS
1
Conceptronic CB100S24S & CB100S48S
Snelstartgids
Gefeliciteerd met uw nieuwe
Conceptronic 24/48-poorts 10/100 Mbps Smart switch.
In deze snelstartgids vindt u stap-voor-stap instructies voor de installatie van de Conceptronic 24/48­poorts 10/100 Mbps Smart switch.
Bij problemen kunt u het beste naar onze support-site gaan (www.conceptronic.net
- klik op 'Support').
Daar vindt u een database met veel gestelde vragen (FAQ).
Als u een vraag over dit product heeft die niet op onze website wordt beantwoord, kunt u ons gerust e­mailen op support@conceptronic.net
.
Ga voor meer informatie over Conceptronic producten naar de Conceptronic website: www.conceptronic.net
.
1. Inhoud verpakking
U vindt de volgende items in de verpakking van de Conceptronic Web Smart switch:
Conceptronic 24/48-poorts 10/100 Mbps Smart Switch (in deze snelstartgids aangeduid als 'de switch').
Netsnoer
DCE RS-232 consolekabel
Switch montageset (2 hoeksteunen met schroeven)
4 rubberen voetjes
Product-cd
Deze snelstartgids
NEDERLANDS
2
2. Aansluitcomponenten
Hieronder ziet u een korte beschrijving van de aansluitcomponenten van de switch.
CB100S24S
24x 10/100 Mbps BASE-T poorten.
• 2x SFP-poorten, rechter zijkant.**
• 4x 1000 BASE-T poorten, rechter zijkant.**
1x DCE RS-232 DB-9 poort (vrouwelijk).
1x Lichtnetaansluiting, achterkant.
Aan/uit- en console-lampjes.
Link/ACT/snelheid-lampjes voor elke poort.
[ CB100S24S ]
** Wanneer de SFP-transceiver een verbinding legt, wordt de bijbehorende 10/100/1000 BASE-T poort
van de switch uitgeschakeld.
NEDERLANDS
3
CB100S48S
48x 10/100 Mbps BASE-T poorten.
• 2x SFP poorten, rechter zijkant.**
• 4x 1000 BASE-T poorten, rechter zijkant.**
1x DCE RS-232 DB-9 poort (vrouwelijk), achterkant van de switch.
1x Lichtnetaansluiting, achterkant.
Aan/uit- en console-lampjes.
Link/ACT/snelheid-lampjes voor elke poort.
[ CB100S48S ]
** Wanneer de SFP-transceiver een verbinding legt, wordt de bijbehorende 10/100/1000 BASE-T poort
van de switch uitgeschakeld.
NEDERLANDS
4
3. Switch installeren
3.1 Switch installeren voor gebruik op bureau of boekenplank
Als u de switch op een bureau of plank wilt zetten, plakt u de meegeleverde rubberen voetjes op de vier hoeken aan de onderkant van de switch. Dit is nodig om voldoende ventilatieruimte te creëren tussen de switch en het oppervlak waarop deze is geplaatst.
3.2 Switch installeren in een rack
De switch kan in een standaard 19" rack worden geplaatst. Zie de volgende afbeeldingen.
Bevestig de hoeksteunen met de meegeleverde schroeven aan de switch. Nadat de steunen stevig zijn bevestigd, kunt u de switch in een standaard rack monteren, zoals aangegeven in de volgende afbeelding.
Rubberen voetjes
NEDERLANDS
5
Let op:
Als u een systeem in een rack zet, kan het rack omvallen als er geen stabilisators aan de
voorkant en de zijkant zijn gemonteerd; dit kan tot schade leiden en onder bepaalde omstandigheden lichamelijk letsel veroorzaken. Plaats dus altijd eerst de stabilisators voordat u componenten in het rack zet. Wanneer een rack meer componenten bevat, moet u er nooit meer dan één tegelijk uitschuiven over de geleiders. Door het gewicht van meer componenten kan het rack omvallen wat tot lichamelijk letsel kan leiden.
3.3 Netsnoer aansluiten
Sluit het netsnoer aan op de lichtnetingang van de switch en doe de stekker in een stopcontact. Wanneer de switch wordt aangezet, knipperen de lampjes even. Dit geeft aan dat het systeem wordt gereset.
NB:
Verwijder bij stroomuitval de stekker van de switch uit het stopcontact. Sluit de switch weer op
het lichtnet aan wanneer er weer stroom is.
NEDERLANDS
6
4. De SFP-poorten installeren
De Managed Web Smart Switches van Conceptronic zijn uitgerust met SFP (Small Form Factor Portable) poorten waarop een transceiver voor optische glasvezelkabel kan worden aangesloten om een (lange­afstand) gigabitverbinding met andere netwerkapparaten te realiseren.
De SFP-poorten ondersteunen full-duplex gegevensuitwisseling, beschikken over automatische onderhandeling en zijn geschikt voor gebruik met de volgende transceivers:
INFINEON / V23818-K15-B57 (1000BASE-LX) 1310nm
INFINEON / V23818-K305-B57 (1000BASE-SX) 850nm
Finisar / FTRJ-1319-7D (1000BASE-LX) 1310nm
CORETEK OPTO CT-0155TSP-MB5L (Single Mode 100BASE-FX) 1310nm
CT-0155NSP-MB2L (Multi Mode 100BASE-FX) 1310nm
Zie de onderstaande afbeelding voor installatie van de SFP-poorten in de switch.
NEDERLANDS
7
5. Switch aansluiten
5.1 Switch naar End Node
"End nodes" zijn onder meer pc's met een 10, 100 or 1000 Mbps RJ 45 Ethernet/Fast Ethernet netwerkkaart (NIC) en de meeste routers. End nodes worden op de switch aangesloten via een UTP/STP kabel, categorie 3, 4 of 5 (twisted-pair). End nodes kunnen op alle poorten van de switch worden aangesloten.
NB:
Alle 10/100/1000 Mbps NWay Ethernet poorten ondersteunen zowel MDI-II als MDI-X verbindingen.
De Link/Act lampjes van elke UTP-poort lichten groen of amber op wanneer de verbinding in orde is. Als een lampje knippert, worden er gegevenspakketten verzonden via de bijbehorende poort.
NEDERLANDS
8
5.2 Switch naar hub of andere switch
Deze verbindingen kunnen op verschillende manieren worden gerealiseerd met normale kabels:
Een 10BASE-T hub of switch kan op de switch worden aangesloten via een UTP/STP kabel, categorie 3,
4 of 5 (twisted-pair).
Een 100BASE-T hub of switch kan op de switch worden aangesloten via een UTP/STP kabel, categorie 5
(twisted-pair).
Een 1000BASE-T hub of switch kan op de switch worden aangesloten via een UTP/STP kabel, categorie
5e (twisted-pair).
Een andere switch met ondersteuning voor glasvezelkabel kan op de SFP-poorten van de switch worden
aangesloten via een optische glasvezelkabel.
NB:
Wanneer een SFP-transceiver een verbinding legt, wordt de bijbehorende 10/100/1000 BASE-T
poort van de switch uitgeschakeld.
Wanneer de switch goed is geïnstalleerd, kunt u hem configureren, de status van de indicatielampjes controleren en statistische informatie grafisch in beeld brengen met een internetbrowser. U kunt ook de seriële aansluiting (RS-232) met een RS-232 crosskabel op een computer of terminal aansluiten om de fabrieksinstellingen te herstellen.
NB:
Zie voor meer informatie over het configureren van de switch de Gebruiksaanwijzing
(beschikbaar in Engels (User Manual) en Spaans) op de meegeleverde product-cd.
crosskabel
normale kabel
switch of hub
ENGLISH
9
Conceptronic CB100S24S & CB100S48S
Quick Installation Guide
Congratulations on the purchase of your
Conceptronic 24/48 Ports 10/100Mbps Smart switch .
This Quick Installation Guide gives you a step-by-step explanation of how to install the Conceptronic 24/48 Ports 10/100Mbps Smart switch.
When problems occur, we advise you to go to our support-site (go to www.conceptronic.net
and click
‘Support’. Here you will find the Frequently Asked Questions Database.
When you have other questions about your product and you cannot find it at our website, then contact us by e-mail: support@conceptronic.net
For more information about Conceptronic products, please visit the Conceptronic Web Site: www.conceptronic.net
1. Package contents
The following items are present in the package of the Conceptronic Web Smart switch:
Conceptronic 24/48 Ports 10/100Mbps Smart Switch (described as ‘switch’ in this guide).
AC Power cable
DCE RS-232 console cable
Switch Mounting Kit (2 brackets with screws)
4 rubber product-feet
Product CD-ROM
This Quick Installation Guide
ENGLISH
10
2. Switch connection components
Below you will find a short description of the connection components of the switches.
CB100S24S
24x 10/100Mbps BASE-T ports.
• 2x SFP ports, located on the right side. **
• 4x 1000BASE-T ports, located on the right side. **
1x Female DCE RS-232 DB-9 console port.
1x AC Power connection, located on the backside of the switch.
Power & Console LED’s.
Link/Act/Speed LED’s for each port.
[ CB100S24S ]
** When the SFP transceiver acquires a link, the associated integrated 10/100/1000BASE-T port is
disabled.
ENGLISH
11
CB100S48S
48x 10/100Mbps BASE-T ports.
• 2x SFP ports, located on the right side. **
• 4x 1000BASE-T ports, located on the right side. **
1x Female DCE RS -232 DB-9 console port, located on the backside of the switch.
1x AC Power connection, located on the backside of the switch.
Power & Console LEDs.
Link/Act/Speed LEDs for each port.
[ CB100S48S ]
** When the SFP transceiver acquires a link, the associated integrated 10/100/1000BASE-T port is
disabled.
ENGLISH
12
3. Switch installation
3.1 Installing the switch for desktop or shelf use
When installing the switch on a desktop or shelf, the rubber feet included with the switch should be attached to the bottom. Attach these rubber feet on the bottom at each corner of the switch. This will allow enough ventilation space between the switch and the surface the switch is placed on.
3.2 Installing the switch in a rack
The switch can be mounted in a standard 19" rack. Use the following images to guide you.
Fasten the mounting brackets to the switch using the screws provided. With the brackets attached securely, you can mount the switch in a standard rack as shown in the next figure.
ENGLISH
13
Warning:
Installing systems in a rack without the front and side stabilizers installed could cause the rack
to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, always install the stabilizers before installing components in the rack. After installing components in a rack, do not pull more than one component out of the rack on its slide assemblies at one time. The weight of more than one extended component could cause the rack to tip over and may result in injury.
3.3 Connecting the AC power cable
Plug one end of the AC power cable into the power connector of the switch and the other end into a free wall outlet. After the switch is powered on, the LED indicators will momentarily blink. This blinking of the LED indicators represents a reset of the system.
Note:
In the event of a power failure, unplug the switch. When power has resumed, plug the switch
back in.
ENGLISH
14
4. Installing the SFP ports
The Conceptronic Managed Web Smart Switches are equipped with SFP (Small Form Factor Portable) ports, which can be used with fiber-optical transceiver cabling, in order to uplink various other networking devices for a gigabit link that may span great distances.
These SFP ports support full-duplex transmissions, have auto-negotiation and can be used with the following tranceivers:
INFINEON / V23818-K15-B57 (1000BASE-LX) 1310nm
INFINEON / V23818-K305-B57 (1000BASE-SX) 850nm
Finisar / FTRJ-1319-7D (1000BASE-LX) 1310nm
CORETEK OPTO CT-0155TSP-MB5L (Single Mode 100BASE-FX) 1310nm
CT-0155NSP-MB2L (Multi Mode 100BASE-FX) 1310nm
See the figure below for installing the SFP ports in the switch.
ENGLISH
15
5. Connecting the switch
5.1 Switch to End Node
End nodes include PCs outfitted with a 10, 100 or 1000 Mbps RJ 45 Ethernet/Fast Ethernet Network Interface Card (NIC) and most routers. An end node can be connected to the switch via a twisted-pair Category 3, 4, or 5 UTP/STP cable. The end node should be connected to any of the ports of the switch.
Note:
All 10/100/1000Mbps NWay Ethernet ports can support both MDI-II and MDI-X connections.
The Link/Act LEDs for each UTP port will light green or amber when the link is valid. A blinking LED indicates packet activity on that port.
ENGLISH
16
5.2 Switch to hub or other switch
These connections can be accomplished in a number of ways using a normal cable:
A 10BASE-T hub or switch can be connected to the switch via a twisted-pair Category 3, 4 or 5 UTP/STP
cable.
A 100BASE-TX hub or switch can be connected to the switch via a twisted-pair Category 5 UTP/STP
cable.
A 1000BASE-T switch can be connected to the switch via a twisted pair Category 5e UTP/STP cable.
A switch supporting a fiber-optic uplink can be connected to the switch’s SFP ports via fiber-optic
cabling.
Note:
When the SFP transceiver acquires a link, the associated integrated 10/100/1000BASE-T port is
disabled.
After you have successfully installed the switch, you can configure the switch, monitor the LED panel, and display statistics graphically using a web browser. Or, you can connect the RS-232 serial to a computer or terminal with a crossover RS-232 cable for loading factory reset purpose.
Note:
For more information of configuring the switch, refer to the ‘User Manual’ (available in English
and Spanish) on the included Product CD-ROM.
ESPAÑOL
17
CB100S24S y CB100S48S de Conceptronic
Guía de instalación rápida
Felicidades por la compra de su
Smart switch de 10/100Mbps y 24/48 puertos de Conceptronic
Esta Guía de instalación rápida le indica detalladamente cómo instalar el Smart switch de 10/100Mbps y 24/48 puertos de Conceptronic.
Si se producen problemas, le aconsejamos que consulte a nuestro servicio técnico (en www.conceptronic.net
y haga clic en “Support”. Aquí encontrará la base de datos de las preguntas más
frecuentes o FAQ).
Si tiene otras preguntas sobre su producto y no las encuentra en nuestro sitio web, póngase en contacto con nosotros por correo electrónico: apoyo@conceptronic.net
.
Si desea más información sobre los productos de Conceptronic, consulte nuestro sitio web: www.conceptronic.net
1. Contenido del paquete
El paquete del Web Smart switch de Conceptronic incluye los elementos siguientes:
Smart switch de 10/100Mbps y 24/48 puertos de Conceptronic (denominado “switch” en esta guía).
Cable de alimentación AC
Cable de consola DCE RS-232
Kit de montaje del switch (2 soportes con tornillos)
4 peanas de goma de fijación del producto
CD-ROM del producto
Esta guía de instalación rápida
ESPAÑOL
18
2. Componentes de conexión del switch
A continuación enumeramos brevemente los componentes de conexión de los switches.
CB100S24S
24 puertos BASE-T de 10/100Mbps
• 2 puertos SFP, ubicados en la parte derecha**
• 4 puertos 1000BASE-T, ubicados en la parte derecha**
1 puerto consola DB-9 hembra DCE RS-232
1 conexión de alimentación AC, ubicada en la parte trasera del switch
LEDs de encendido y consola
LEDs Link/Act/Velocidad para cada puerto
[ CB100S24S ]
** Cuando el transceptor SFP incorpore un enlace, el puerto 10/100/1000BASE-T asociado integrado
quedará desactivado.
ESPAÑOL
19
CB100S48S
48 puertos BASE-T de 10/100Mbps
• 2 puertos SFP, ubicados en la parte derecha**
• 4 puertos 1000BASE-T, ubicados en la parte derecha**
1 puerto consola DB-9 hembra DCE RS-232, ubicado en la parte trasera del switch
1 conexión de alimentación AC, ubicada en la parte trasera del switch
LEDs de encendido y consola
LEDs Link/Act/Velocidad para cada puerto
[ CB100S48S ]
** Cuando el transceptor SFP incorpore un enlace, el puerto 10/100/1000BASE-T asociado integrado
quedará desactivado.
ESPAÑOL
20
3. Instalación del switch
3.1 Instalación del switch para su uso en un escritorio o en un estante
Cuando instale el switch en un escritorio o en un estante, deberá colocar y adherir las peanas de goma que incluye el producto en la parte inferior de cada esquina del switch. Así dejará suficiente espacio de ventilación entre el switch y la superficie sobre la que reposa.
3.2 Instalación del switch en un rack
El switch puede instalarse en un rack estándar de 19". Consulte la ilustración siguiente a modo de orientación.
Ajuste los soportes de fijación al switch utilizando los tornillos que incluye el producto. Una vez fijados los soportes de forma segura, podrá montar el switch en un rack estándar tal y como muestra la ilustración siguiente.
Peanas de goma
ESPAÑOL
21
Atención
: Instalar sistemas en un rack sin haber montado primero los estabilizadores frontal y lateral
podría hacer que el rack volcase y provocar lesiones en determinadas situaciones. Por tanto, monte siempre los estabilizadores antes de instalar componentes en un rack. Una vez instalados los componentes, no saque del rack más de un componente al mismo tiempo por las juntas deslizantes. El peso de varios componentes de grandes dimensiones podría hacer que el rack volcase y provocar lesiones.
3.3 Conectar el cable de alimentación AC
Enchufe uno de los extremos del cable de alimentación AC en un conector de alimentación del switch y el otro extremo, a una toma libre de pared. Una vez encendido el switch, los LEDs parpadearan unos instantes, lo cual indica que el sistema se está reiniciando.
Nota
: En caso de que se produzca un corte de corriente, desenchufe el switch. Una vez recuperada la
corriente, vuelva a enchufarlo.
ESPAÑOL
22
4. Instalación de los puertos SFP
Los conectores Web Smart Switches de Conceptronic están equipados con puertos SFP (Small Form Factor Portable), que pueden utilizarse con cableado de fibra óptica del transceptor para realizar enlaces
ascendentes con otros dispositivos de red y obtener un enlace gigabit capaz de abarcar grandes distancias.
Estos puertos SFP son compatibles con transmisiones full-duplex, tienen autonegociación y pueden utilizarse con los transceptores siguientes:
INFINEON / V23818-K15-B57 (1000BASE-LX) 1310 nm
INFINEON / V23818-K305-B57 (1000BASE-SX) 850 nm
Finisar / FTRJ-1319-7D (1000BASE-LX) 1310 nm
CORETEK OPTO CT-0155TSP-MB5L (modo individual 100BASE-FX) 1310 nm
CT-0155NSP-MB2L (modo múltiple 100BASE-FX) 1310 nm
Consulte la ilustración siguiente para instalar los puertos SFP en el switch.