CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
BOUT THIS MANUAL
A
This manual provides installation and operation information for the Comtech EF Data
CIC-20 LVDS to HSSI Interface Converter. This is a technical document intended for
earth station engineers, technicians, and operators responsible for the operation and
maintenance of the CIC-20 LVDS to HSSI Interface Converter.
ELATED DOCUMENTS
R
Comtech EF Data CDM-600 Digital Satellite Modem Installation and Operation Manual
ONVENTIONS AND REFERENCES
C
AUTION S AND WARNINGS
C
Indicates information critical for proper equipment function.
IMPORTANT
Indicates a hazardous situation that, if not avoided, may result in minor or moderate
injury. CAUTION may also be used to indicate other unsafe practices or risks of
CAUTION
WARNING
RADEMARKS
T
property damage.
Indicates a potentially hazardous situation that, if not avoided, could result in
death or serious injury.
All product names mentioned in this manual may be trademarks or registered trademarks
of their respective companies and are hereby acknowledged.
EPORTING COMMENTS OR SUGGESTIONS CONCERNING THIS MANUAL
R
Comments and suggestions regarding the content and design of this manual will be
appreciated. To submit comments, please contact the Comtech EF Data Customer
Support Department.
v
CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
ELECOMMUNICATIONS TERMINAL EQUIPMENT DIRECTIVE
T
In accordance with the Telecommunications Terminal Equipment Directive 91/263/EEC,
this equipment should not be directly connected to the Public Telecommunications
Network.
EMC (E
The CIC-20 LVDS to HSSI Interface Converter has been demonstrated, by independent
testing, to comply with the following standards:
FCC P
ART
In order that the CIC-20 LVDS to HSSI Interface Converter continues to comply with
these standards, observe the following instructions:
All 'D' type connectors attached to the unit must have back-shells which provide
The equipment must be operated with its cover on at all times. If it becomes
LECTROMAGNETIC COMPATIBILITY
Emissions: EN 55022 Class B - Limits and methods of measurement of radio
interference characteris t ics of I nformation Technology Equipment.
15 C
continuous metallic shielding. Cable with a continuous outer shield (either foil or
braid, or both) must be used, and the shield must be bonded to the back-shell.
necessary to remove the cover, the user should ensure that the cover is correctly refitted before normal operation commences.
LASS
Immunity: EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic,
B
commercial and light industr ial env ironm ent.
)
vi
CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
AFETY COMPLIANCE
S
EN 60950
Applicable testing is routinely performed as a condition of manufacturing on all units to
ensure compliance with safety requirements of EN60950.
This equipment meets the Safety of Information Technology Equipment specification as
defined in EN60950.
The equipment is rated for operation at +12 volts DC and -12 volts DC. It has a
maximum power consumption of 2.0 watts. The power supply current is, in all
circumstances, supplied by a single Comtech CDM-600 Modem.
QUIPMENT CONNECTION
E
The CIC-20 LVDS to HSSI Interface Converter is designed for operation ONLY with
Comtech CDM-600 modems. These modems supply DC operating current (electronically
fused and protected) and control signals for the correct functioning of this unit.
Connection to other manufacturer’s equipment could result in damage to the unit.
NVIRONMENTAL
E
The CIC-20 LVDS to HSSI Interface Converter must not be operated in an environment
where the unit is exposed to extremes of temperature outside the ambient range 0 to 500C,
precipitation, condensation, or humid atmospheres above 95% RH, altitudes (unpressurised) greater than 2000 meters, excessive dust or vibration, flammable gases,
corrosive or explosive atmospheres.
Operation in vehicles or other transportable installations which are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.
vii
CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
OW VOLTAGE DIRECTIVE
L
(LVD)
The following information is applicable for the European Low Voltage Directive
(EN60950):
<HAR> Type of power cord required for use in the European Community.
CAUTION: Double-pole/Neutral Fusing.
!
ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung.
International Symbols:
Symbol Definition Symbol Definition
Alternating Current.
Fuse.
Protective Earth.
Chassis Ground.
Note:
For additional symbols, refer to “Cautions” listed earlier in this preface.
viii
CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
ARRANTY POLICY
W
This Comtech EF Data product is warranted against defects in material and workmanship
for a period of two years from the date of shipment. During the warranty period, Comtech
EF Data will, at its option, repair or replace products that prove to be defective.
For equipment under warranty, the customer is responsible for freight to Comtech EF
Data and all related custom, taxes, tariffs, insurance, etc. Comtech EF Data is responsible
for the freight charges only for return of the equipment from the factory to the customer.
Comtech EF Data will return the equipment by the same method (i.e., Air, Express,
Surface) as the equipment was sent to Comtech EF Data.
IMITATIONS OF WARRANTY
L
The foregoing warranty shall not apply to defects resulting from improper installation or
maintenance, abuse, unauthorized modification, or operation outside of environmental
specifications for the product, or, for damages that occur due to improper repackaging of
equipment for return to Comtech EF Data.
No other warranty is expressed or implied. Comtech EF Data specifically disclaims the
implied warranties of merchantability and fitness for particular purpose.
XCLUSIVE REMEDIES
E
The remedies provided herein are the buyer's sole and exclusive remedies. Comtech EF
Data shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any other legal theory.
ISCLAIMER
D
Comtech EF Data has reviewed this manual thoroughly in order that it will be an easy-touse guide to your equipment. All statements, technical information, and
recommendations in this manual and in any guides or related documents are believed
reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and
they are not intended to be, nor should they be understood to be, representations or
warranties concerning the products described. Further, Comtech EF Data reserves the
right to make changes in the specifications of the products described in this manual at any
time without notice and without obligation to notify any person of such changes.
ix
CIC-20 LVDS to HSSI Interface Converter Revision 0
Preface MN/CIC20.IOM
x
Chapter 1. INTRODUCTION
CIC-20
LVDS to HSSI
Interface Converter
While the CDM-600 modem is capable of data rates up to 20 Mbps, its many interfaces
do not include the HSSI format.
In order to accommodate the HSSI data formats and overhead, the CIC-20 converter
attaches to the rear of the modem at the 25-pin data connectors. No external power is
required and all settings are made on the CIC-20 using one switch.
1
CIC-20 LVDS to HSSI Interface Converter Revision 0
Introduction MN/CIC20.IOM
This page has been intentionally left blank.
2
Chapter 2. INSTALLATION
Perform the following procedural steps:
1
Power down the modem before installing the converter.
2
Remove the four screws, on the sides, and lift off the cover of the CIC-20.
3
The 25-pin female and male D-sub connectors includes four captive screws which can be
reached by removing the cover of the CIC-20.
4
Attach the CIC-20 to the CDM-600 modem by mating the two pair of 25-pin D-subs together,
then tighten the four captive screws.
5
Re-attach the cover and replace the four screws. The metal surfaces of the modem and CIC20 should be flush.
3
CIC-20 LVDS to HSSI Interface Converter Revision 0
Installation MN/CIC20.IOM
This page has been intentionally left blank
.
4
Chapter 3. CONNECTOR PINOUTS
ONNECTOR OVERVIEW
C
3.1
The rear panel connectors (shown in Table 1) provide all necessary external connections
between the modem and other equipment.
Table 1. External Connections
Name Ref Connector Type Function
Overhead P1 25-pin D (male) Overhead Data
Connector
Locations
Data Interface J1 50-pin, mini-D SCSI-II
HSSI (female)
Note:
To maintain compliance with the European EMC Directive (EN55022, EN50082-1)
properly shielded cables are required for data I/O.
2 IDR 64 kbps ESC Tx Data - TX-422DAT-A In
12 IDR 64 kHz ESC Tx Clock + TX-422CLK-B Out
15 IDR 64 kHz ESC Tx Clock - TX-422CLK-A Out
11 IDR 1 kHz Tx Octet Clock + TX-OCT-B Out
24 IDR 1 kHz Tx Octet Clock - TX-OCT-A Out
16 IDR 64 kbps ESC Rx Data + RX-422DAT-B Out
3 IDR 64 kbps ESC Rx Data - RX-422DAT-A Out
9 IDR 64 kHz ESC Rx Clock + RX-422CLK-B Out
17 IDR 64 kHz ESC Rx Clock - RX-422CLK-A Out
19 IDR 1 kHz Rx Octet Clock + RX-OCT-B Out
4 IDR 1 kHz Rx Octet Clock - RX-OCT-A Out
20 Balanced Ext. Ref. Clock + EXT-CLK-B In
23 Balanced Ext. Ref. Clock - EXT-CLK-A In
13 IBS ESC RS232 Tx Data TX-232-DATA In
22 IBS ESC RS232 Tx Clock TX-232-CLK Out
8 IBS ESC RS232 Rx Data RX-232-DATA Out
10 IBS ESC RS232 Rx Clock RX-232-CLK Out
5 IBS Tx High-Rate ESC Data TX-ASYNC In
6 IBS Rx High-Rate ESC Data RX-ASYNC Out
1 IDR Back Alarm 1 H/W input BW-IN1 In
18 IDR Back Alarm 2 H/W input BW-IN2 In
21 IDR Back Alarm 3 H/W input BW-IN3 In
25 IDR Back Alarm 4 H/W input BW-IN4 In
Signal Ground SG 102 1, 26
Receive Timing RT 115 2, 27 From DCE
DCE Available CA 107 3, 28 From DCE
Receive Data RD 104 4, 29 From DCE
Loopback Circuit C LC undefined 5, 30 Not used
Send Timing ST 114 6, 31 From DCE
Signal Ground SG 102 7, 32
DTE Available TA 108/2 8, 33 To DCE
Terminal Timing TT 113 9, 34 To DCE
Loopback Circuit A LA 143 10, 35 Not used
Send Data SD 103 11, 36 To DCE
Loopback Circuit B LB 144 12, 37 Not used
Signal Ground SG 102 13, 38
Reserved (to DCE) 14,15,17, 18,
Tx_Carrier_Off_L
(Notes 1 and 3)
Signal Ground SG 102 19, 44
Carrier Detect (lock)
(Notes 1 and 2)
Mod Fault
(Notes 1 and 4)
Demod Fault
(Notes 1 and 4)
Unit Fault
(Notes 1 and 4)
Reserved (to DTE) 22-23
Test Mode TM 142 24, 49 Not used
Signal Ground SG 102 25, 50
1. Noted signal function names are non-HSSI defined signals. On Cisco™ routers there
is no connection to those pins.
2. TTL - output.
3. TTL or RS232 (active low) input
4. TTL – open collector output.
The HSSI interface uses the type of SCSI-2 connector shown in Figure 2.
Figure 2.
SCSI-2 Connectors
8
Chapter 4. OPERATION
4.1 MODEM CONFIGURATION
After applying power to the modem, the following configuration changes must be made
to the modem in order for it to operate with the CIC-20.
1
Program the transmit and receive data rates to what is desired for Tx and Rx.
2
Set the data interface type to LVDS. The modem itself operates in this electrical format while
the converter translates between LVDS and HSSI.
4.2 MODE SELECT
The dip switch (S2) selects the functionality of the control signals, CA and TA. It can be
accessed with a small screwdriver. The OFF (down) position is the default. Switch S1 is
not used.
OFF (Down) TA TO CA LOOP
Figure 3.
Switch Location
Dip Switch S2
ON (Up) TA CONTROLS TX CARRIER
RR CONTROLS CA
9
CIC-20 LVDS to HSSI Interface Converter Revision 0
Operation MN/CIC20.IOM
This page has been intentionally left blank.
10
Chapter 5. SUMMARY OF
SPECIFICATIONS
Equipment Type
Modems Supported
Terrestrial (User) Data Interface:
Type
HSSI Signals Supported
Other Signals Supported
Electrial Connector
Modem Data Interface
Type
Data Rate:
Electrical Connector
Power Requirements
LVDS / HSSI Interface Converter
Comtech EF Data CDM-600 Digital Satellite Modems
HSSI (synchrounous serial)
RT, RD, ST, TT, SD, TA, CA,
Per EIA-612 (10KH ECL)
CD, DF, MF, TX_CARRIER_OFF
50-pin mini-D female per EIA-613 (HSSI)
LVDS, Serial
2.4 kbps to 20.0 Mbps
25-pin D male
2.0 Watts maximum
+12 volts DC
-12 volts DC
(Power is supplied by the Modem. These power supplies
are electronically fused and protected.)
Approvals
‘CE’ as follows:
EN 55022 Class B (Emissions)
EN 50082-1 (Immunity)
EN 60950 (Safety)
FCC Part 15 Class B
11
CIC-20 LVDS to HSSI Interface Converter Revision 0
Specifications MN/CIC20.IOM
This page has intentionally left blank.
12
METRIC CONVERSIONS
Units of Length
Unit
1 centimeter — 0.3937 0.03281 0. 01094
1 inch 2.540 — 0.08333 0.2778
Centimeter
Inch
Foot
Yard
Mile
6.214 x 10
1.578 x 10
Meter
-6
-5
0.01 — —
0.254 — 25.4
Kilometer Millimeter
—
-4
0.3048 — —
-4
0.9144 — —
-4
— — —
1.609 x 103
1.609 —
1 foot 30.480 12.0 — 0.3333
1 yard 91.44 36.0 3.0 —
1 meter 100.0 39.37 3.281 1.094
1 mile
1 mm — 0.03937 — — — — — —
1 kilometer — — — — 0.621 — — —
1.609 x 10
5
6.336 x 104 5.280 x 103 1.760 x 103
1.893 x 10
5.679 x 10
6.214 x 10
Temperature Conversions
Ounce
Troy
Formulas
C = (F - 32) * 0.555
F = (C * 1.8) + 32
Pound
Avoir.
Pound
Troy
Kilogram
Unit
32° Fahrenheit
212° Fahrenheit
-459.6° Fahrenheit
Fahrenheit
°°°°
—
—
—
Centigrade
°°°°
0
(water freezes)
100
(water boils)
273.1
(absolute 0)
Units of Weight
Unit
1 gram — 0.03527 0.03215 0.002205 0.002679 0.001
Gram
Ounce
Avoirdupois
1 oz. avoir. 28.35 — 0.9115 0. 0625 0.07595 0.02835
1 oz. troy 31.10 1.097 — 0.06857 0.08333 0.03110
1 lb. avoir. 453.6 16.0 14.58 — 1.215 0.4536
1 lb. Troy 373.2 13.17 12.0 0.8229 — 0.3732
1 kilogram
1.0 x 10
3
35.27 32.15 2.205 2.679 —
2114
WEST 7TH STREET TEMPE ARIZONA
85281
480 • 333 • 2200
480 • 333 • 2161
USA
PHONE
FA
X
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.