The AlphaServer 800 is an Alpha server ba sed on the Alpha 21164
microprocessor 500 MHz CPU with 2 MB ECC cache. Servers are available in Pedestal and Rackmount c onfi gurat i ons with a c hoi ce of DIGITAL UNIX and OpenVMS operating systems. The AlphaServer 800 offers the foll owing high reliability features: hot swap drives, Remote Management Console, and ECC memory. Integrated on system motherboard is an UltraSCSI adapter, SVGA controller (TRIO-S3 with 1MB RAM), Remote Mana gem e nt Console , di skett e controller, two seria l port s, one pa ral le l port, a nd ke yboa rd and m ouse interfaces.
The AlphaServer 800 systems support eight internal stora ge devi c es, inc l uding a floppy diskette, a CD-ROM, two additional 5.25-inch removable media device bays, and four hot swap SCA-2 Ultra disk drives. System supports up 2 GB of memory and 72 GB of internal stora ge with four 18 GB disks instal le d.
System Ordering Rules
AlphaServer 800 Packaged Systems do not incl ude a system di sk or an
Ethernet (10/100 Mbit) ada pt er. Sel e ct ion of a system disk and a ne twork adapter is mandatory. Users can sel e ct a 4. 3 GB, 9 GB, or 18 GB disk as the system disk.
To order a complete system, select (1) a System, (2) a System Disk, and
(3) a Network Adapter.
M-series Cabinet Enclosures
Cabinet enclosures are available in three sizes: 43-inch, 67-inch, and 79-inch;
see Cabinet Configurati on Cha rt for m a xim um systems and Stora ge Works shelves supported in M-series Cabinet Enc l osures.
The AlphaServer 800 integrat e d Re mot e Manage m ent Console (RMC) feat ure s significantly enhances the ability to remotely manage and diagnose system conditions. The RMC allows a remote operator to monitor server voltages, temperatures, and fan, as well as manipulate the server (Power On/Off, reset, halt). An auxiliary regulator powers the RMC in the main power system that allows systems to be remotely interrogated even if systems are turned off or shut down. In the event of an alert condition, the RMC can be set up to automatical l y dia l a user de fi nabl e page r phone or anot he r system t o m ake a remote operator aware of the alert condition.
ServerWORKS Manager provides advanced server a nd net work ma na gem e nt capabilities and is supplied with all AlphaServer systems. Simple Network Management Protocol (SNMP) enables informa ti on t o pass from the m ana ge d system t o t h e c o n sole for DIGIT AL UNI X a n d Op enVMS systems. Using ServerWORKS, the system manager m ay bui l d and vi e w topologi c a l m a ps of the network. Detail ed serve r i nforma t ion i s vie wable , inc l uding system , network, storage, and envi ronm ent a l i nform at ion. Ala rm s may be set aga i nst critical system parameters and events. All AlphaServer systems are supplied with management tools to complement ServerWORKS Manager.
Compaq and the names of Compaq products referenced herei n ar e either trademarks and/or service marks or registered tr ademarks and/or servi ce ma r ks of Compaq.
DIGITAL is a Trademark of Compaq C omputer Corporation. Microsoft , Windows, Windows NT, SQL Server, Office and BackOf fice are either trademarks or regis tered trademarks of Microsoft C orporation. Intel and Pentium are regist ered trademarks of Int e l Corporation. Other product and company names me ntioned herein may be tr adem arks and/or service ma r ks of their respect ive owners.
Alpha Servers 2.25
Page 2
AlphaServer 800 Pedestal–Rackmount

Step 1—AlphaServer 800 Pedestal and Rackmount Package Systems

Configuration menus require t he ma nda tory sel e ct i on of:
DIGITAL UNIX Packaged System from Step 1a, or
OpenVMS Packaged System from Step 1b, and
Minimum of one Ethe rne t Ada pte r a nd one Ult ra SCSI disk from Step 1c
Note: See Step 7 for M-series Cabinet E nc losure c onfi gurat i on rule s Pedestal and Rackmount Syst ems include
Alpha microproce ssor 21164 500 MHz CPU with
2 MB onboard ECC cache
Pedestal enclosure with
- Six expansion slots: three PCI and one PCI/EISA
combo and two EISA
- Onboard UltraSCSI adapter supports internal
removable media (CD-ROMs and tapes) and i nt erna l storage shelf only
- Onboard S3 SVGA Graphic
- 8 DIMM memory slots support 2 memory kits
- Eight storage slots
One diskette drive slot with 1. 44 MB floppy dri ve One CD-ROM drive slot with 600 MB CD-ROM Two additional half he i ght (or one ful l he i ght) removable media slot s Four SCA-2 UltraSCSI hard drive slots
- Two serial ports: One serial port wit h full dupl ex
asynchronous modem control; one RMC dedi c at e d serial port with full duple x async hronous modem control.
- One bi-directional e nha nce d pa ral l el port
- PS/2 style keyboard port and mouse port
350 W switchable (120/ 240 V, 60/ 50 Hz) power supply
3-button mouse.
120 V power cord. Select c ount ry-speci fi c power c ord
for all non North American orders.
US English documentat ion.
Integrated Advanc ed Serve r Mana gem e nt fe a t ures,
including ServerWORKS Manager kit.
DIGITAL UNIX Unlimited User license, Server
Extension license, Inte rne t Alpha Serve r System software kit, or
OpenVMS base license with System Manager license,
Enterprise Integrated Package
Hardware warranty: thre e-ye a r onsite
Software Warranty
90-day SPD conformance with advisory tele phone support for DIGITAL UNIX and Open VMS.
1
1
1. Service upgrades are ava il a ble . See Step 10. Note: Rackmount packaged systems must be i nstal l ed i n a c abi ne t. System c an be i nstal l ed i n a n exi sti ng ca bi ne t or sel e ct
a cabinet from Step 7.
2.26 Alpha Servers
Page 3
AlphaServer 800 Pedestal–Rackmount

Step 1a—DIGITAL UNIX Packaged Systems

All DIGITAL UNIX Pedestal and Rackmount pa c kage d
systems i n c l u d e p re-instal led DIGITAL UNI X, B a se license, Unlimited User license, Server Extension license, and Inte rnet Acc ess Server Software (IASS) media and license.
DIGITAL UNIX packaged systems include factory
instal l ed software ( FI S) DI GI T AL UNI X V4 . 0 D o n h a r d disk drive.
Note: Ra c kmount pa cka ge d systems must be i nstal l ed i n a ca bi ne t. System ca n be i nstal l ed i n a n exi sti ng ca bi net or sel ec t
a cabinet from Step 7.
DIGITAL UNIX Pedestal Pac ka ged Systems
Order Number Operating System CPU Memory Disk Ethernet Graphics Monitor PB82C-FB PB82C-FC PB82C-FD PB82C-FE PB82C-FF
DIGITAL UNIX 500 64 MB Mandatory Mandatory Onboard Recomme nde d DIGITAL UNIX 500 128 MB Mandatory Mandatory Onboard Recomme nde d DIGITAL UNIX 500 256 MB Mandatory Mandatory Onboard Recomme nde d DIGITAL UNIX 500 512 MB Mandatory Mandatory Onboard Recomme nde d DIGITAL UNIX 500 1 GB Mandatory Mandatory Onboard Recomme nde d
DIGITAL UNIX v a r i ants order e d i n No r t h Am e r i ca
include a 104/105-key PC style US Engli sh keyboa rd
Selection of a keyboa rd a nd power cord i s ma ndat ory for
all non North American orders.
A minimum of 64 MB memory is recommended for
DIGITAL UNIX
Order DIGITAL UNIX media and documenta t ion
separately. See Step 9.
DIGITAL UNIX Rackmo unt P a c ka ged Systems
Order Number Operating System CPU Memory Disk Ethernet Graphics Monitor PB82S-FB PB82S-FC PB82S-FD PB82S-FE PB82S-FF
DIGITAL UNIX 500 64 MB Mandatory Mandatory Onboard Rec om me nde d DIGITAL UNIX 500 128 MB Mandatory Mandatory Onboard Recommended DIGITAL UNIX 500 256 MB Mandatory Mandatory Onboard Recommended DIGITAL UNIX 500 512 MB Mandatory Mandatory Onboard Recommended DIGITAL UNIX 500 1 GB Mandatory Mandatory Onboard Recommended
Key: Mandatory items must be on purchase order at initial order acceptance.
Recommended items enhance system functionality.

Step 1b—OpenVMS Packaged Systems

All packaged systems include pre-installed OpenVMS,
Base license, and DIGITAL Enterprise Integration Package. See Step 9 for contents.
OpenVMS packaged systems include Factory Installed
Software (FIS) OpenVMS V7.1-1H2 on the hard disk.
Note: Rackmount pa cka ge d systems must be i nstal l ed i n a ca bi ne t. System c an be i nstal l ed i n a n exi sti ng ca bi net or sel ec t
a cabinet from Step 7.
OpenVMS Pedestal Pa c ka g e d Sy st e m s
Order Number Operating System CPU Memory Disk Ethernet Graphics Monitor PB82C-MB PB82C-MC PB82C-MD PB82C-ME PB82C-MF
OpenVMS 500 64 MB Mandatory Mandatory Onboard Rec om me nde d OpenVMS 500 128 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 256 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 512 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 1 GB Mandatory Mandatory Onboard Recommended
OpenVMS variants ordered in North Americ a i nc lude a
108-key, VT style US English keyboard.
Selection of a keyboa rd a nd power cord i s ma ndat ory for
all non North American orders.
Order Open VMS media and document at i on separa t el y.
See Step 9.
Alpha Servers 2.27
Page 4
AlphaServer 800 Pedestal–Rackmount
Step 1b—OpenVMS Packaged Systems
(continued)
OpenVMS Rac km o unt Packaged Syst e m s
Order Number Operating System CPU Memory Disk Ethernet Graphics Monitor PB82S-MB PB82S-MC PB82S-MD PB82S-ME PB82S-MF
OpenVMS 500 64 MB Mandatory Mandatory Onboard Rec om me nde d OpenVMS 500 128 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 256 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 512 MB Mandatory Mandatory Onboard Recommended OpenVMS 500 1 GB Mandatory Mandatory Onboard Recommended
Key: Mandatory items must be on purchase order at initial order acceptance.
Recommended items enhance system functionality.

Step 1c—Mandatory Options

Selection of a System Disk drive a nd a Network Adapte r i s mandatory. Additiona l disks and net work ada pte rs are supported, select as requi red.
Select one System Disk Drive—Mandatory
4.3 GB disk drive is recommended as System Disk. If more than one size of disk is ordered the Operating System will be factory installed on t he smal le st di sk.
Order Number Sys t em Di sk and M i ni m um O / S ver si on s uppor te d DIGITAL UNIX OpenVMS RZ1CF-SB RZ1DF-SB DS-RZ1DD-SB RZ1EF-SB DS-RZ1ED-SB
1
1
2
2
1. KZPAC RAID Array 230/Plus Controller supports 9 GB drives—for configuration information on getting around the 32 GB Logical Drive Limit of the KZPAC, see the Systems and Option Catalog file for Storage RAID Controllers dated 10 September 1998 and Customer Update da te d 15 August 1997 at :
http://webir.das.dec.com/info/CU5911/CU5911HM.HTM
2. Not supported on KZPAC-xx PCI-based RAID controllers.
4.3 GB 7200 RPM UltraSCSI disk V4.0B V6.2-1H3
9.1 GB 7200 RPM UltraSCSI disk V4.0B V6.2-1H3
9.1 GB 10000 RPM UltraSCSI disk V4.0B V6.2-1H3
18.2 GB 7200 RPM UltraSCSI disk V4.0B V6.2-1H3
18.2 GB 10000 RPM UltraSCSI disk V4.0B V6.2-1H3
Select one Network Adapter—Mandatory
Order Number Net work Adapter and Mi ni m um O / S ve rs i on s upport ed DIGITAL UNIX OpenVMS KZPCM-DA
PCI-based two port UltraSCSI Single-ended adapter and
V4.0D V7.1-1H1
10/100 Mbit Ethernet com bo a dapt e r, uses 1 PCI slot
DE500-AA DE500-BA DE504-BA
10/100 Ethernet adapt e r UTP V4.0B V6.2-1H3 Same as -AA above with cluster fail ove r V4.0D V7.1-1H1 10/100-Mbit Quad Ethernet, High conne c ti vi ty wit h 4
V4.0D V7.1-1H1
channels
2.28 Alpha Servers
Page 5
AlphaServer 800 Pedestal–Rackmount

Step 2—Memory

System supports two memory kits for a ma xi mum of 2 GB of me mory.
Packaged systems include one memory kit.
Each kit i nc l ude s four i ndust ry-st a ndard DIMMs wi t h E CC support .
PB8MA-AC PB8MA-AD PB8MA-AE PB8MA-AF PB8MA-AG
64 MB (4 x 16 MB DI MMs) m e mory kit 128 MB (4 x 32 MB DIMMs) memory kit 256 MB (4 x 64 MB DIMMs) memory kit 512 MB (4 x 128 MB DIMMs) memory kit 1 GB (4 x 256 MB DIMMs) memory kit

Step 3—Storage

Select additional storage devices as required. See Storage Devices section for more information.

Step 3a—Internal Storage

An onboard UltraSCSI adapter is included in each system to support a maximum of seven internal devices, four SCA-2
disk drives plus three removable de vic e s.
Internal Storage included
- One 600 MB 12X CD-ROM drive
- One 1.44 MB diskette drive in de dic a te d slot
Additional Inte rnal Storage supporte d
- Three hard disk drive bays
- Two removable 5.25-inc h hal f-he ight re mova bl e m e dia ba ys, or
One removable 5.25-inc h full -he ight re mova bl e m e dia ba y
Internal Disk Drives
Selection of one System Disk Drive i s mandatory, see Step 1c.
Up to three addit iona l hard di sk drive s are supporte d i nte rna ll y.
RZ1CF-SB RZ1DF-SB DS-RZ1DD-SB RZ1EF-SB
1
DS-RZ1ED-SB
1
4.3 GB 7200 RPM UltraSCSI SCA-2 3.5 x 1” hard disk drive
9.1 GB 7200 RPM UltraSCSI SCA-2 3.5 x 1.6" hard disk drive
9.1 GB 10000 RPM UltraSCSI SCA-2 3.5 x 1.6" hard disk drive
18.2 GB 7200 RPM UltraSCSI SCA-2 3.5 x 1.6" hard disk drive
18.2 GB 10000 RPM UltraSCSI SCA-2 3.5 x 1.6" hard disk drive
1. Not supported on KZPAC-xx PCI-based RAID controllers.
Internal Removable Media Devices
All Pedestal and Ra ckm ount pac ka ge d systems inc lude one 600 MB CD-ROM drive.
System supports two additional 5.25-inch half-height removable media devices, or one additional 5.25-inch full-hei ght
removable media de vic e .
RRD47-AB PBXTZ-AA TLZ09-LK TLZ10-LK
600 MB 5.25 inch half-height 32X CD-ROM drive
2.0 GB 5.25 inch half-height SCSI QIC tape dri ve (T Z K11)
8.0 GB 5.25 inch x 1.6-inch SCSI 4 mm DAT drive , em be dded 12/24 GB 4 mm DAT SCSI tape drive, embe dded
Internal SCSI Ca bl e Kits
PB8HA-DA
Internal 68-pin HD SCSI cables. Connect s 16-bit wide SCSI adapte rs and c ontrol l ers, KZPAC-xx, KZPCM-DA, or KZPBA-CA to internal storage assembly. Maximum one per system.
BC25V-1H
Internal UltraSCSI cable bre a kout a ssembl y kit . Conne ct s the thi rd port of the KZPAC-CA/CB to one of the two expansion breakout slot s on bac k of AlphaServe r 800.
Alpha Servers 2.29
Page 6
AlphaServer 800 Pedestal–Rackmount

Step 3b—Storage Adapters/Controllers

All systems include a n onboard Ult ra SCSI adapte r to
support a maximum of seven int e rnal de vic e s; four SCA­2 hard disk drives and three remova bl e m e dia de vic e s.
If the internal drives are connected to a PCI-based RAID
controller (KZPAC-xx) instead of the onboa rd Ultra SCSI adapter, Fault Mana gem e nt m ust be disabl e d when t he RCU (Raid Configuration Utility) is executed.
- PB8HA-DA cable is required to connect opti ona l PCI-
based RAID controller to interna l disk drive s.
Maximum number of KZPAC PCI-based RAID
controllers supported is four.
Order Number Description KZPCM-DA
BN37A-02
PB8HA-DA
PCI-based two port UltraSCSI Si ng l e - e nded adapter and
10/100Mbit Ethernet Combo a da pte r, uses 1 PCI slot. Int erna l 68-pin and 50-pin HD connec tors and two e x t e r n a l 6 8 -p i n VHDC I connectors.
2 mete r VHDCI m a le to VHDCI m a l e UltraSCSI cable fo r e x t e r nal connections. Required for each UltraSCSI StorageWorks shelf attached to KZPCM.
Internal 68-pin HD SCSI cables. Connect s 16-bit wide SCSI controller KZPCM to internal storage assembly, maximum one per system.
Charts indicate minimum level of operating system
supported. Note: Minimum ope ra ti ng system l e vel support for DIGITAL UNIX wi t h ME MOR Y C HANNE L i s V4 .0B.
Refer to the Supporte d Options Li st for O/S support
http://www. di gi t a l .com/alphase rve r/ t ech_docs/alphasrv8 00/docs/supported_options.html
The following ada pte rs and c ontrol l ers are supporte d.
SCSI cables are not inc lude d a nd must be orde re d
separately.
External DSSI cable s are not i ncl ude d a nd must be
ordered separately.
Maximum # Supported
DIGITAL UNIX
V4.0D
OpenVMS
V7.1-1 H1
22
KZPBA-CA
PCI-based one po r t Ul t r a SCSI Si ng l e-ended adapter, internal 68-
pin and 50-pin HD connectors and exte rnal 68-pi n HD connect or.
BN38C-02
2 mete r 68 - pi n HD m ale to VHDCI m a le Ultra SCSI c able. Re q u i r e d for each external UltraSCSI shelf attached to KZPBA.
PB8HA-DA
Internal 68-pin HD SCSI cables. Connect s 16-bit wide SCSI controller KZPBA to internal storage assembly, maximum one per system.
KZPBA-CB
1
PCI-based one port UltraSCSI Differential adapter, 68-pin HD
connector
BN38C-02
2 mete r 68 - pi n HD m ale to VHDCI m a le Ultra SCSI c able. Re q u i r e d for each external UltraSCSI shelf attached to KZPBA.
Order Number Description KZPSA-BB
PCI-based one port Fast Wide Differential (FWD) SCSI adapter
with 68-pin HD external connect or. Supports Single-E nde d stora ge devices via the DWZZ A or DWZZ B signal c onvert e rs. Int erna l hard disk drives are not supported on KZPSA adapter.
BN21K-02
2 meter SCSI cable 68-pin HD straight m al e c onnec t or with t humb latches and one 68-pin HD right angl e ma l e c onne ct or wit h screw fasteners.
BN31G-xx
SCSI Cable 68-pin HD straight connector at each end; -xx denotes length of cable
BN21W-0B DWZZB-xx
SCSI Cable 68-pin HD SCSI "Y" Cable SCSI bus signal converter. 16-bit differe nt ia l to 16-bi t Single -E nded
22
22
Maximum # Supported
DIGITAL UNIX
V4.0B
OpenVMS
V7.1-1 H1
44
KZPAA-AA
BN21N-02
2.30 Alpha Servers
PCI-based one po r t F a st Narrow Single-Ended (FNSE) SCSI adapter with 50-pin external connec t or
2 meter 8-bit to 16-bit SCSI cable, connects KZPAA to 16-bit Fast10 SCSI StorageWorks shelf.
44
Page 7
AlphaServer 800 Pedestal–Rackmount
Step 3b—Storage Adapters/Controllers
Order Number Description KZPAC-AA
2,3
PCI-based one port UltraSCSI RAID controller with 4 MB cache
(continued)
Maximum # Supported
DIGITAL UNIX
V4.0B
OpenVMS
V7.1-1 H1
44
memory, includes RAID Array 230/Plus Subsystem software and documentation kit for DIGITAL UNIX and OpenVMS. 68-pin HD connec t o r fo r i nternal connection and 68- pin VHDCI bulkh e a d connector for external c onnec t ion. T a pe dri ve s are not supporte d. KZPAC-xx requires PB8HA-DA SCSI cable kit for connection to internal storage assembly. If the internal drives are connected to the KZPAC Fault Management must be disa ble d when RCU is exe c ute d.
KZPSC-UB PB8HA-DA
4
Cache battery bac kup for KZPAC control le r Internal 68-pin HD SCSI cables. Connect s 16-bit wide SCSI
controller KZPAC to internal storage assembly, maximum one per system.
BN37A-02
2 mete r VHDCI m a le to VHDCI m a l e UltraSCSI c a b l e for exte r n a l connections. Required for each UltraSCSI StorageWorks shelf attached to KZPAC.
KZPAC-CA
1,2
PCI-based three port UltraSCSI RAID controller with 4 MB
22
cache memory, includes RAID Array 230/Plus Subsystem Software and documentation ki t for DIGITAL UNIX and OpenVMS. Tape drives are not supported. SCSI cable is required for each active port. BN31K-0E or KZPAC-SB or BC25V-1H must be ordered for connection of third port t o bul khea d bre akout . KZPAC-xx requires PB8HA-DA SCSI cable kit for connection to internal storage assembly. If the internal drives are connected to the KZPAC Fault Management must be disa ble d when RCU is exe c ute d.
KZPAC-CB KZPSC-UB MS100-BB
1,2
Same as KZPAC-CA with 8 MB cache memory 22
3
Cache battery bac kup for KZPAC control le r 8 MB EDRAM cache memory replacement, upgrades KZPAC-CA to
KZPAC-CB
PB8HA-DA
Internal 68-pin HD SCSI cables. Connect s 16-bit wide SCSI controller KZPAC to internal storage assembly, maximum one per system.
BN37A-xx
VHDCI male to VHDCI male Ultra SCSI c able for e x t ernal connections. Required for each UltraSCSI StorageWorks shelf attached to KZPAC.
BN31S-1E
1.5 meter VHDCI to 68-pi n HD SCSI c a bl e for e xte rna l c onne c ti ons. Required for each Fast10 StorageWorks shelf attached to KZPAC.
BC25V-1H
UltraSCSI cable breakout assembl y ki t. Conne c ts int e rnal t hird port of KZPAC-CA/CB to one of the two external bulkhe a d brea kout slots.
BN31K-0E
SCSI cable/bulkhead assembly kit with one port for KZPAC-CA/CB, allows connection of one thi rd port output using one PCI bulkhea d slot.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPAC-CA/CB, allows connection of two third port out puts using one PCI bulkhe a d slot.
1. DIGITAL UNIX and OpenVMS operating systems currently support the KZPBA-CB adapter via di re ct a tt a chm e nt i n existing environments. Multi-host shared SCSI bus configurations using the KZPBA-CB adapter are supported on OpenVMS systems. Multi-host configurations are not currently supported on DIGITAL UNIX systems. For a complete list of restrictions, refe r t o Supported Opti ons Li st at :
http://www.di gi t a l .com/alphase rve r/ t e c h_doc s/ a l pha srv800/ doc s/ support e d_opt i ons.html
2. 18.2 GB disk drives are not supported on KZPAC-xx PCI-based RAID controllers.
3. KZPAC RAID Array 230/Plus Controller supports 9 GB drives—for configuration information on getting around the 32 GB Logical drive Limit of the KZPAC, see the Systems and Option Catalog file for Storage RAID Controllers dated 10 September 1998 and Customer Update da te d 15 August 1997 at :
http://webir.das.dec.com/info/CU5911/CU5911HM.HTM
4. KZPSC-UB is recommended for KZPAC RAID controllers.
Alpha Servers 2.31
Page 8
AlphaServer 800 Pedestal–Rackmount
Step 3b—Storage Adapters/Controllers
KZPAC-SB
(.5 METER)
DSSI Controll e rs
Order Number Description KFPSA-AA BC29S-xx
BC29S-09
PCI-based one po r t DSSI a dapt e r (OpenVMS systems only) 4
For KFPSA PCI base d DSSI c o ntroller . KFPSA to any e x t e r n a l “Micro-Ribbon” DSSI right-angle connec t ion (a l l ot he r DSSI systems and storage devices requiri ng ri ght-a ngl e c onne ct i on) requi re s BC29S-xx DSSI cable.
For KFPSA PCI base d DSSI c o ntroller . Order BC29 S- 09 DSSI c a b le for HSD10 in BA36R-Ax shelves
(continued)
KZPAC-CA/CB
KZPAC-CA/CB
Maximum # Supported
DIGITAL UNIX
V4.0B
OpenVMS
V7.1-1 H1

Step 3c—External Tape Expansion

External t ape dri ves are a lso supported on opt i onal PCI-based SCSI adapte rs.
- KZPAA-AA—maximum bus length including cable and tape device cannot exceed 3.0 meters.
- KZPSA-BB—maximum bus length including cable and tape device cannot exceed 25.0 meters.
External t ape dri ves are not supported on KZ PAC-xx UltraSCSI RAID controllers on systems running DIGITAL UNIX
or OpenVMS.
External Tapes
Minimum level of op erating syst em requi r e d : DI GITAL UNIX V4.0B, OpenVMS V7.1 -1 H1 .
TLZ09-DB
TLZ9L-DB
1,2
DS-TLZ10-DB
1. Includes four cartridge loa de r. La rge r ma ga zi ne s are supported.
2. Base operating systems support sequential backup mode only; additional software is required for random access backup. See Storage Devices section for details.
2.32 Alpha Servers
4.0/8.0 GB 4 mm DAT tablet op t ape dri ve wit h 50-pi n LD SCSI port. Inc lude s BN23G-01 with one male 50-pin LD connect or a nd one m a le 50-pi n HD connec tor.
32/64 GB 4 mm DAT tabletop autoloader with 50-pin LD SCSI port. Includes BN23G-01 cable with one male 50-pin LD connec t or and one m a le 50-pi n HD connect or.
12/24 4mm DAT SCSI tabletop tape dri ve . Requi re s SCSI cable BN23G-01 (for 50-pin HD host) or BN31W-01 (for 68-pin HD host)
Page 9
AlphaServer 800 Pedestal–Rackmount
Step 3c—External Tape Expansion
TSZ07-CA/FA
40/140 MB1600 b/in tabletop ta pe drive (SE/ DIFF). Require s country ki t which i nc lude s ca ble s
(continued)
(TSZK7-xx; see StorageWorks tape devi c e sec t ion.
TSZ07-AA/DA
40/140 MB 1600 b/in rackmountable t ape dri ve. Re qui res count ry ki t whic h i ncl ude s ca ble s (TSZK7-xx; see StorageWorks tape devi c e sec t ion.
TSZ07-BA/EB
40/140 MB 1600 b/in tape drive in (H9642/H9A10) cabinet. Incl ude s SCSI cable (see StorageWorks tape device sec ti on).
DS-TZ89N-TA
35/70 single-ended DLT tabl e top t a pe dri ve with 68-pi n HD fema l e c onne ct or. Re quire s BN21K-xx SCSI cabl e.
TZK11-DA DS-TZS20- DB
2.0 GB QIC tabletop tape dri ve. Inc l udes SCSI termi na tor, a nd 3 foot SCSI cable . 25/50GB AIT (8 mm) tabletop ta pe drive —Bl ue. SCSI cabl e not i nc lude d. Re quire s BN21N-01 for
50- pin HD host, or BN31G-01 for 68-pin HD host SCSI cable.
SCSI Cables for E x ternal Tape s
BN23G-01
3 foot molded SCSI cable. 50-pi n Single -E nded SCSI cabl e (one 50-pi n HD straight ma l e connector with thumb la t che s and one 50-pin L D strai ght m a le c onne ct or wit h bal e loc ks.)
BN23G-0E
1.5 foot molded SCSI cable. 50-pi n Single -E nded SCSI cabl e (one 50-pi n HD straight ma l e connector with thumb la t che s and one 50-pin L D strai ght m a le c onne ct or wit h bal e loc ks.)
BN21K-xx
Single-Ended SCSI cable 68-pin HD straight m a le c onnec t or with t hum b la t che s and one 68-pi n HD right angle male conne c tor wit h scre w fastene rs.

Step 4—Monitors

Graphi cs monito rs o t h e r t h a n t h ose listed below can b e u se d i f c o m p a t ible wit h SVGA g r a p hics ordere d wi th a system .
Higher resolutions are available with optional PCI graphics adapters. See Step 5.
Note: Selection of a video extension cable a nd a c ountry spec i fic power c ord is mandatory for all monitor variants.
See Step 4a for video extension c a ble . See Step 4b for country specific power c ords.
SN-VRQV5-24/23
15" (13.8" viewable ima ge siz e ) Corpora te Seri es aut o-sca n col or m onit or, fl at square Inva r CRT,
0.28 mm dot pitc h, VGA t o 1024 x 768 @ 75 Hz , T CO 95, MPRII, E ne rgy St a r, a t t ac he d 1.8 meter video cable. Requires mandatory selection of video ext e nsion ca bl e and c ount ry specific power cord for all variants. –24 = Northern Hemisphere without power cord –23 = Southern Hemisphere without power cord
SN-VRQP7-24/23
17” (16.0” viewable i ma ge size ) profe ssional seri e s auto-sca nni ng col or m onit or, T rini t ron CRT,
0.25 mm aperture grill pitch, VGA to 1280 x 1024 at 75 Hz, TCO 95, MPR-II, E ne rgy St a r, a t t a c he d
1.8 meter video c abl e . Requi re s ma ndat ory sel ec t ion of vi de o ext e nsion ca bl e a nd c ountry spec i fic power cord for all variants. –24 = Northern Hemisphere without power cord. –23 = Southern Hemisphere without power cord. .
SN-VRQP1-24/23
21" (19.6" viewable ima ge size ) a uto-sca nni ng col or m onit or, T ri nit ron CRT , 0. 25 mm a pert ure gril l pitch, VGA to 1600 x 1200 at 75 Hz NI, T CO 95, E ne rgy St a r, i nc l ude s a 1. 8 m e te r vi de o c a bl e . Requires mandatory selec t ion of vi de o ext e nsion ca bl e a nd c ountry spec i fic power c ord for al l variants. –24 = Northern Hemisphere without power cord. –23 = Southern Hemisphere without power cord.
Step 4a
BN39C-02
Video Extension Cable
1.8 meter video extension cable—mandatory for each monitor ordered
Alpha Servers 2.33
Page 10

Step 4b— Mo n i t or P ower Co rds

AlphaServer 800 Pedestal–Rackmount
BN26J-1K BN19H-2E BN19C-2E BN19A-2E BN19E-2E BN19K-2E BN19Z-2E BN19S-2E BN18L-2E
North Ame r i c a Australia, New Zeala nd, 2. 5 me t ers long Central Europe, 2. 5 m et e rs long UK, Ireland, 2.5 met ers long Switzerland, 2.5 me t ers long Denmark, 2.5 mete rs long Italy, 2.5 met e rs long Egypt, India, South Africa , 2. 5 me t e rs long Israel, 2.5 mete rs long

Step 5—Graphics Adap t ers

Select only i f addi t iona l graphi c s card i s requi red.
All system s i n c lude onboa rd SVGA wi t h 1 MB vi de o RAM. Onboa rd SVGA m ust be di sa bl e d whe n usi ng m ulti-head
graphics options.
Maximum of one PB2GA-JD supporte d pe r syst e m . Onboa rd SVGA m u st be di sa bl e d.
PB2GA-JC PB2GA-JD
PCI-based 1 MB DRAM graphics adapter PCI-based 2 MB DRAM graphics adapter

Step 6—Networks and Communications

Refer to the Supported Options List for O/S support, re stri ct i ons, a nd ma xi mum numbe r of opt ions supported pe r system at
http://www.di gi t a l .com/alphase rve r/ t e c h_doc s/ a l pha srv800/ doc s/ support e d_opt i ons.html
DE500-AA DE500-FA DE504-BA DE450-CA
DEFPA-AB
DEFPA-DB
DEFPA-UB
DGLPA-FA DGLPA-UA
PBXDA-AA PBXDA-AB PBXDP-AA PBXDP-AB PBXDP-AC SN-PBXNP-AC
CXI01-AA
CXI01-AB CXI01-AC CXI01-AF
PCI-based 10/100 Mbit Fast Ethernet ada pte r (T wisted Pai r) PCI-based 10/100 Mbit Ethernet ada pte r MMF PCI-based 10/100 Mbit quad channel Et he rnet a da pte r Ca t 5 UTP PCI-based 10 Mbit Ethernet adapter (Twisted Pair, Thick wire, ThinWire)
PCI-based FDDI adapter, single attachment station (SAS), multi-mode fiber (MMF); maximum supported is four, DIGITAL UNIX and OpenVMS
PCI-based FDDI adapter, dual attachment station (DAS), multi-mode fiber (MMF); maximum supported is four, DIGITAL UNIX and OpenVMS
PCI-based FDDI adapter, SAS, TP-PMD, requires BN25H-xx; maximum supported is four, DIGITAL UNIX a n d Op e n VMS
PCI-based ATMworks 351 adapter, MMF SC connector PCI-based ATMworks 351 adapter, UTP CAT 5 with RJ45 connector
PCI-based 4 port asynchronous communicati ons cont roll er—not supporte d in PCI/E ISA combo slot PCI-based 8 port asynchronous communicati ons cont roll er—not supporte d in PCI/E ISA combo slot PCI-based 2 port synchronous communications cont roll e r, ma xi mum t wo PCI-based 4 port synchronous communications cont roll e r, ma xi mum t wo PCI-based 8 port synchronous communications cont roll e r, ma xi mum t wo PCI-based Token Ring Adapter, ma xim um four, DIGITAL UNIX and OpenVMS
ISA-based asynchronous MUX adapter, 16 lines – expandable t o 64 li ne s; DIGITAL UNIX not supported in bottom EISA/ISA slot
ISA-based Asynchronous 16 port XEM expansion for CXI01-AA ISA-based asynchronous MUX cable converter RJ45 to DB25 Eight pack RJ45-MJ11 converters for Asynchronous MUX adapter
2.34 Alpha Servers
Page 11
AlphaServer 800 Pedestal–Rackmount

Step 7—Cabinet En closu res an d Accessories

Rackmount Packa ged System s must be insta l le d i n a c a bine t .
System can be installed in an existing cabinet or select an M-series Cabinet Enclosure.
Select Cabi net E ncl osure ba sed on numbe r of System s and Storage W orks Shelve s supported.
M-series Top Gun Blue Cabinet Enclosures are available in three sizes:
43” high Cabinet Enclosure (H9A11-xx) 20U or 35.0” of usable vertical space.
67” high Cabinet Enclosure (H9A10-xx) 31U or 54.2” of usable vertical space.
79” high Cabinet Enclosure (H9A15-xx) 38U or 66.5” of usable vertical space.
Cabinet Configuration Cha r t
Cabinet Enclosure Mounti ng K i t Cabinet Height and Space System Shelve s Ballast Kit H9A11-MC/MD
H9A10-MC/MD
H9A15-MC/MD
1. 79” H9A15 Cabinet supports a minimum of two AlphaServe r 800 system s, i nstal l at i on of one system i s not supporte d.
Included in Rackmount System
Included in Rackmount System
Included in Rackmount System
35.0 inches 20U 1
54.2 inches 31U 1
66.5 inches 38U 2
4 2 3
4
0
6 2 3 4 5
1
3 4 5
6
6
2
0
6
6
6
4
1
2 1
2
M-series Cabinet Enclosure Options M-series Cabinet Enclosures require t he mandatory sele c ti on of:
H9A11, H9A10, or H9A15 Cabinet 120V or 240V variant.
Cabinet front door ba sed on ca bi net he ight (opt iona l on H9A11 cabi net ).
Factory Integrat ion.
Ballast kits as required.
Cabinet Enc l o sures
H9A11-MC
120 V one 24 A controller with 10 NEMA 5-15R outlets, i nput power pl ug NEMA L5-30P, Americas, Asia Pacific. Includes rear door, 1 H7600-AA power distribution unit, trim kit, and front filler bezel kit
H9A11-MD
240 V one 16 A controller with 12 IEC C13 outle t s, i nput power pl ug IE C 309, 16A, E urope Includes rear door, 1 H7600-DB power distribution unit, trim kit, and front filler bezel kit
H9A10-MC
120 V dual 24 A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific Includes rear door, top fan t ray, a nd 2 H7600-AA power distributi on unit s
H9A10-MD
240 V dual 16 A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe Includes rear door, top fan t ray, a nd 2 H7600-DB power distribut ion uni t s
H9A15-MC
120 V dual 24 A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific Includes rear door, top fan t ray, a nd 2 H7600-AA power distributi on unit s
H9A15-MD
240 V dual 16 A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe Includes rear door, top fan t ray, a nd 2 H7600-DB power distribut ion uni t s
For custom integration of systems, opt i ons, a nd addi t iona l Compa q a nd thi rd pa rty de vi ce s, or for ot he r ca bi net s, doors, and trim kits of a differe nt col or, c onta c t Com pa q CustomSystem s at 1-800-DIGITAL, or cont a ct your l oca l aut hori ze d Compaq Certified Integration Partner.
Alpha Servers 2.35
Page 12
AlphaServer 800 Pedestal–Rackmount
Step 7—Cabinet En closu res an d Accessories
(continued)
Cabinet Front Door
H9C10-TF H9C15-TF H9C11-EB
1
Top Gun Blue front door for H9A10-MC/MD Cabinet Enclosure Top Gun Blue front door for H9A15-MC/MD Cabinet Enclosure Top Gun Blue front door for H9A11-MC/MD Cabinet Enclosure
1. Selection of front door for H9A11 cabinet is optional, cabinet includes front trim kit and filler bezel kit.
Shelves supported in M-series Cabi ne t s with front doors (H9A10/M 9 A1 5 )
BA36R-RC
StorageWorks UltraSCSI single bus, single-ende d shelf wit h 180 W power supply and RE T MA mounting kit
BA36R-RD
StorageWorks UltraSCSI split bus, single-ended shelf with 180 W power supply and RETMA mounting kit
BA35R-MR
StorageWorks controller shelf wit h RET MA mounti ng kit a nd NEMA power for H9A10-MC, H9A15-MC cabinets (Americas, Asia Pacific) Order BN30B-02 power cord for H9A10-MD, H9A15-MD cabinets (Europe)
CK-BA35X-HH
180 W power supply
Shelves supported in M-series Cabi ne t s with trim ki t ( H9A11)
BA35C-AA
StorageWorks UltraSCSI single bus, single-ende d shelf wit h 180 W power supply and RE T MA mounting kit—blue bezel
BA35C-BA
StorageWorks UltraSCSI split bus, single-ended shelf with 180 W power supply and RETMA mounting kit—blue bezel
Factory Integration
YS-ASCAA-AA
Factory Integration of systems and stora ge devi c es assembl e d and c onfi gured i n c abi ne t e nc losure i n pre-defined locati ons
Ballast Kit
Ballast is dead weight that is added to a cabinet at specific locations for specific configurations to meet safety regulations for installation, ope ra t ion, a nd servic e . See Cabi ne t Confi gura ti on Cha rt for ba l la st kit re quire m ent s.
H9C10-MC
Two 35-40 lbs. steel plate s
For additional informat ion on M-serie s Cabi net E ncl osures visit www. di gi t a l .com/alphaserver/products/m-se ri e s. h t m l
Compaq CustomSystems Support
Cabinets containing system s and stora ge m ust be assembl e d by qual i fie d a ssembl ers: Com pa q Manufac t uring, Com pa q’s Customs Systems Group, or an authorized Compa q Cert i fie d Int egra t ion Part ne r.
For custom integration of systems, opt i ons, a nd addi t iona l Compa q a nd thi rd pa rty de vic e s, or for ot her c a bine t s, doors, and trim kits of a differe nt col or, c onta c t Com paq Custom System s at 1-800-DIGITAL, or cont a ct your l oca l aut hori ze d Compaq Certified Integration Partner.
2.36 Alpha Servers
Page 13
AlphaServer 800 Pedestal–Rackmount

Step 8—Keyboards and Power Cords

Keyboards
System ordered in the Americ a s and Asia Paci fi c i nc lude s keyboa rd and power c ords. Sel e ct c ountry-spec i fic ke yboard for all non North American Pedesta l and Ca bi ne t system orde rs. All keyboa rds are opal gra y.
DIGITAL UNIX Keyboard OpenVMS Keyboard Country SN-LKQ47-AA LK461-AA SN-LKQ47-AB LK461-AB SN-LKQ47-AC LK461-AC SN-LKQ47-AD LK461-AD SN-LKQ47-AE SN-LKQ47-AF LK461-AF SN-LKQ47-AG LK461-AG
LK461-AH SN-LKQ47-AI LK461-AI SN-LKQ47-AK LK461-AK
LK461-AL SN-LKQ47-AM LK461-AM SN-LKQ47-AN LK461-AN SN-LKQ47-AP LK461-AP
LK461-AQ SN-LKQ47-AR SN-LKQ47-AS LK461-AS
LK461-AT
SN-LKQ47-AV LK461-AV SN-LKQ47-AX SN-LKQ47-BA SN-LKQ47-BH LK461-BH SN-LKQ47-BI SN-LKQ47-BK
LK461-BL SN-LKQ47-BP LK461-BP SN-LKQ47-BQ LK461-BQ SN-LKQ47-BR SN-LKQ47-BT LK461-BT SN-LKQ47-BU LK461-BU SN-LKQ47-BV LK461-BV
LK461-BW
LK461-BY SN-LKQ47-CB SN-LKQ47-CZ LK461-CZ
US/English Belgian Canadian/French Danish UK Finnish German Dutch Italian Swiss/French Swiss/Germ an Swedish Norwegia n French Canadian/English Latin-American Spanish Hebrew Brazil Portuguese Bhesy International Greek Taiwanese Korean Romanian Polish Hungarian Arabic Cyrillic Turkish Czech Turkish-French Yugoslavian Thai Slovak
Alpha Servers 2.37
Page 14
AlphaServer 800 Pedestal–Rackmount
Step 8—Keyboards and Power Cords
(continued)
Pedestal Power Cords
North American vari ant s inc lude (North Ame ric a n, Japan) power c ord. If a nothe r power c ord i s selec t ed, bot h power
cords ship wi th system.
Selection of a power cord i s ma ndat ory for a ll non North Ame ric a n orders.
BN26J-1K BN19H-2E BN19C-2E BN19A-2E BN19E-2E BN19K-2E BN19Z-2E BN19S-2E BN18L-2E
North Ame r i c a Australia, New Zeala nd, 2. 5 me t ers long Central Europe, 2. 5 m et e rs long UK, Ireland, 2.5 met ers long Switzerland, 2.5 me t ers long Denmark, 2.5 mete rs long Italy, 2.5 met e rs long Egypt, India, South Africa , 2. 5 me t e rs long Israel, 2.5 mete rs long
Rackmount Power Cords
North American vari ant s inc lude BN20Z-4E 120 V (North Americ a n, Japan) power c ord. If a nothe r power c ord i s
selected, both power cords ship with system.
Selection of a power cord i s ma ndat ory for a ll non North Ame ric a n orders.
Note: AlphaServer 800 Pedestal system power c ords are l ess then 15 fe e t l ong a nd ar e not supporte d in c a bine t enc l osures.
BN20Q-4E
15 feet (4.5 m) 240 V, North Americ a n, 50 Hz power cord connects system to power distribution unit located inside cabinet
BN20Z-4E
15 foot (4.5 m) 120 V, 60 Hz power cord connec ts system t o power di stribut i on unit loc a t ed i nside cabinet
BN35S-4E
15 foot (4.5 m) 240 V, European IEC C13, 50 Hz power cord c onne ct s system t o power distri but ion unit located inside cabinet
Pedestal to Rackmount Co nv e rsion Kit
PB8HA-BA
AlphaServer 800 Pedestal to Rackmount conversion kit. Includes bezel, slide rails and mounting hardware necessary for mounting system in any cabinet equipped with industry-standard RETMA or METRIC rails. Rackmount powe r cords must be orde red sepa ra te l y.
Mouse and Ext ension Cable K it
PBXWS-WA 2T-450KM-AA
3-button mouse (included with all systems, order as spare or replacement) Extension cab le ki t for VGA, PC st yl e ke yboa rd, a nd m ouse , for use wi th Rac k mount syst e m s.

Step 9—Software

DIGITAL UNIX
Software Processor Code = E
DIGITAL
Software kit and Unlimited User license.
DIGITAL UNIX packaged systems require operat ing system m edi a and doc um ent a ti on for fi rst system on sit e .
DIGITAL UNIX Media and Documentation—required for first system on site
QA-MT4AA-H8 QA-MT4AA-GZ
UNIX packaged systems include DIGITAL UNIX base license, Server Extension , Internet AlphaServer
DIGITAL UNIX media and online document at i on on CD-ROM DIGITAL UNIX full hardcopy documentation
2.38 Alpha Servers
Page 15
AlphaServer 800 Pedestal–Rackmount
Step 9—Software
(continued)
StorageWorks Software Packages for DIGITAL UNIX
QB-5RXAE-AA
StorageWorks Software Package (includes licenses for Logical Storage Manager and AdvFS Utilities).
QB-5RYAE-AA
StorageWorks Software Package (includes licenses for Logical Storage Manager and AdvFS Utilities plus Networker Save and Restore).
TruCluster Available Server License
QL-05SAE-AA
TruCluster Available Server License
DIGITAL UNIX Software Layered Products Library CD-ROM
QA-054AA-H8
Layered products media a nd doc ume nt at i on for DIGITAL UNIX on CD-ROM
DECnet for DIGITAL UNIX
QL-MTJAE-AA QL-MTKAE-AA
DECnet/OSI end-syst e m license f or DI GITAL UNIX DECnet/OSI extended function l i ce nse for DIGITAL UNIX
OpenVMS
Software Processor Code = E
OpenVMS Concurrent Use Licenses are not specific to a single system and can be moved between systems at user
discretion.
OpenVMS Co ncurrent Use License s c an also be shared in a m ixed OpenVMS VAX a n d OpenVMS Alpha Cl u st er.
OpenVMS Concurrent Use Licenses
QL-MT3AA-3B QL-MT3AA-3C QL-MT3AA-3D QL-MT3AA-3E QL-MT3AA-3F QL-MT3AA-3G QL-MT3AA-3H QL-MT3AA-3J QL-MT3AA-3K QL-MT2AE-AA
OpenVMS Concurrent Use 1-user license OpenVMS Concurrent Use 2-user license OpenVMS Concurrent Use 4-user license OpenVMS Concurrent Use 8-user license OpenVMS Concurrent Use 16-user license OpenVMS Concurrent Use 32-user license OpenVMS Concurrent Use 64-user license OpenVMS Concurrent Use 128-user license OpenVMS Concurrent Use 256-user license OpenVMS Traditional unlimited user license
OpenVMS layered products
QL-MUZAE-AA QL-2A1AE-AA
OpenVMS Cluster License Volume Shadowing License
OpenVMS me di a a nd do c um e nt at i o n— r equired for first system on site
QA-MT1AA-H8 QA-MT1AG-H8 QA-MT1AD-H8 QA-001AA-GZ
OpenVMS media and online document a ti on CD-ROM (V7.1) OpenVMS media and online document a ti on CD-ROM (V6.2-1H3) OpenVMS media and online document a ti on CD-ROM (V7.1-1H1) OpenVMS hardcopy documentation
)2
1
1. Required to run UltraSCSI.
2. UltraSCSI is not currently supported on OpenVMS V6.2-1H3. OpenVMS V6.2-1H3 runs in Fast10 SCSI Mode.
OpenVMS Layered Products CD-ROM
QA-03XAA-H8
1
Layered products media a nd doc ume nt at i on for OpenVMS on CD-ROM
1. Includes DIGITAL Enterprise Integrat i on Packa ge for OpenVMS media a nd doc ume nt at i on.
Alpha Servers 2.39
Page 16
AlphaServer 800 Pedestal–Rackmount
Step 9—Software
(continued)
DECnet for OpenVMS
QL-MTGAE-AA QL-MTHAE-AA
DECnet extended functi on l ic e nse for OpenVMS DECnet end-system to extende d func ti on upgra de l i ce nse for OpenVMS
DSSI Informati o n
EK-410AB-MG EK-D4AXP-TS
DSSI VMScluster Installation Guide DSSI VMScluster Troubleshooting Guide

Step 10—Hardware and Software Supplemental Support Services

Hardware—Americas and Asia Pacific only
Systems include three-year hardware warranty, onsite with 5 x 9, 24 hour response time.
Select opti onal Hardware Supplem e nta l Support Servic e s if requi re d.
Select optional Hardware Installation.
FM-CH4HR-36 FM-CH512-36 FM-CH616-36 FM-CH724-36 FM-CHXHW-60 FM-CH4HR-60 FM-CH512-60 FM-CH616-60 FM-CH724-60 FM-24INT-IN
5 x 9, 4 hour response time 5 x 12, 4 hour response time 6 x 16, 4 hour response time 7 x 24, 4 hour response time Years 1-5, next day, Onsite Years 1-5, 5x9, 4 hour response time Years 1-5, 5x12, 4 hour response time Years 1-5, 6x16, 4 hour response time Years 1-5, 7x24, 4 hour response time Hardware Installation
Software—Americas and Asia Pacific only
DIGITAL UNIX and OpenVMS systems include 90-day Conformance to SPD and Telephone Advisory Support. Sel e ct optional Software Supplement al Support Servi ce s, i f re quire d.
FM-80BUS-12 FM-80BUS-36 FM-80BUS-60 FM-80BUN-12 FM-80BUN-36 FM-80BUN-60 FM-80BVS-12 FM-80BVS-36 FM-80BVS-60 FM-80BVN-12 FM-80BVN-36 FM-80BVN-60
12-month Full Software Supplementa l Support for DIGITAL UNIX AlphaServer 800 systems 36-month Full Software Supplementa l Support for DIGITAL UNIX AlphaServer 800 systems 60-month Full Software Supplementa l Support for DIGITAL UNIX AlphaServer 800 systems 12-month Node Software Supplemental Support for DIGITAL UNIX AlphaServer 800 systems 36-month Node Software Supplemental Support for DIGITAL UNIX AlphaServer 800 systems 60-month Node Software Supplemental Support for DIGITAL UNIX AlphaServer 800 systems 12-month Software Supplemental Support for OpenVMS AlphaServer 800 systems 36-month Software Supplemental Support for OpenVMS AlphaServer 800 systems 60-month Software Supplemental Support for OpenVMS AlphaServer 800 systems 12-month Node Software Supplemental Support for OpenVMS AlphaServer 800 systems 36-month Node Software Supplemental Support for OpenVMS AlphaServer 800 systems 60-month Node Software Supplemental Support for OpenVMS AlphaServer 800 systems

Step 10a—Hardware and Software Supplemental Support Services (Europe only)

Europe does not have specific pa rt num be rs for Hardware and Software Supple me nt al Support Servi ce s. Pric e s can be quoted using the Excele ra tor t ool ; c ont ac t MCS Sales in your count ry for inform a ti on on Hardware and Software Supplemental Support Service s.
2.40 Alpha Servers
Page 17
AlphaServer 800 Pedestal–Rackmount

Step 11—CPU Upgrades

Order Number From To Includes PB82U-AZ
PB82U-FZ
AlphaServer 800 5/333 AlphaServer 800 5/500 500 MHz CPU
Note: Mandatory ret urn of 333 MHz CPU
AlphaServer 800 5/400 AlphaServer 800 5/500 500 MHz CPU
Note: Mandatory ret urn of 400 MHz CPU
Alpha Servers 2.41
Page 18
AlphaServer 800 Pedestal–Rackmount
AlphaServer 800 System Diagram–Side View
9
8
1. Removable side cover of system e nc losure
2. Floppy diskette drive
3. Removable media dri ves
4. Lower and upper doors
5. Control panel
7
2
3
4
5
1
6
6. Hard disk drives
7. System board
8. CPU daughter card
9. Power supply
AlphaServer 800 System Diagram – Rear of Enclosure
11
5 6 7
1
2
3
10
9 8 4
12
1. Three 32-bit PCI slots
2. One 64-bit PCI/EISA slot
3. Two EISA slots
4. Parallel port
5. Serial port
6. Mouse port
2.42 Alpha Servers
7. VGA port
8. Keyboard port
9. Remote console mode m port
10.Power inlet
11.Serial port/terminal port (MMJ with data leads only)
12.SCSI breakouts
Page 19
AlphaServer 800 Pedestal Specifications
AlphaServer 800 Pedestal–Rackmount
Shipping Dimensi on
Height Width Depth Weight
Installed Dim e nsi o ns
Height Width Depth Weight
Clearances Operating Service
Front Rear Left sid e Right side
Environmental
Temperature Operating
Relative humidity Operating
Maximum wet bulb temperature Minimum dew point temperature Maximum heat dissi pati on 380 Wat t
Air flow and quality Intake location
Altitude Operating Mechanical shock Operating Vibration Operating 10-500 Hz .1 G peak
Acoustics Operating LNPEc (BELs)
Electrical—Power Suppl i es are uni ve rs al 120/ 240 Vac
Nominal ac voltage Operating Voltage range Power source phase Nominal frequency Frequency range RMS current at nominal voltage (steady state) Maximum Power Consumption (Watts) Power cord Type
47 cm (18.5 in.) 60 cm (23.6 in)
77.5 cm (30.5 in) 33 kg (73 LB) typical 37 kg (82 LB) maximum
45 cm (17.1 in.)
22.6 cm (8.9 in.)
65.8 cm (25.9 in.)
24.5 kg (54 LB) typical 28 kg (62 LB) maximum
75 cm (29.5 in.) 15 cm (5.9 in.) None None
1
Nonoperating Storage (60 days) Rate of change
Nonoperating Storage (60 days) Rate of change Operating Storage (60 days) Operating Storage (60 days)
1297 Btu/hr Exhaust location
Particle size Concentration
2
Nonoperating Nonoperating
100-120 V ac 90-128 V ac Single 50/60 Hz 49/51/59-61 Hz
7.0 Amps 380 Watts
Length US plug
75 cm (29.5 in.) 75 cm (29.5 in.) 75 cm (29.5 in.) 5 cm (2 in.)
1040° C (50104° F) Not tested
-4066° C (-40151° F) 11° C/hr (20° F/hr)
20–80% 20–80% 10–95% 20%/hr 28° C (82° F) 46° C (115°F) 2° C (36° F) Not tested
Front Rear N/A N/A 3097 m (10,000 ft) 12190 m (40,000 ft)
7.5 G 10 ms 20 G peak 30 ms
6.0 MAX per ISO 7779
220-240 Vac 180-256 Vac Single 50/60 Hz 49-51/59-61 Hz
3.0 Amps IEC 320 C13
190 cm (75 in.) NEMA 5-15
Alpha Servers 2.43
Page 20
AlphaServer 800 Pedestal–Rackmount
AlphaServer 800 Pedestal Specifications (continued)
Regulatory
Agency approvals UL Listed to UL1950 (3rd edition)
Reviewed to AS 3260:1993 Australia n/New Zealand Standar d
1. Maximum operating tem per atur e at Sea Level. Reduce by 1 C (1.8 F) f or each 600 m (2000 ft) above Sea Level.
2. Higher altitudes are possible if maximum operating temperature is reduced (see Temperature, above); other re st ri ct i ons m ay appl y, such as m axi m um per m is si bl e altitude for hard drives.
AlphaServer 800 Rackmount Specifications
CSA Certified to CAN/CSA-C22.2 No. 950-M95 TUV EN 60950 GS marked CB Certification pending FCC (Class B) Part 15, Subpart B (CFR 54,1995) EMC Directive 89/336/EEC EN 55022:1994 Class B EN 50082-1 1992 Light Industrial CE Class B VCCI Class II ITE AS/NZS 3548:1992 (Class B)
EN 60 950: 1995 European Norm IEC 950
Shipping Dimensi on Installed Dim e nsi o ns
Height Width Depth Weight
Clearances Service
Front Rear Sides
Environmental
Temperature Operating Nonoperating Storage (60 days) Relative humidity Operating Nonoperating Storage (60 days) Rate of change Air flow and quality Intake location Exhaust location
Electrical—Power Suppl i es ar e uni ve rsal 120/ 240 V ac
Same as Pedesta l
Regulatory
Same as Pedesta l
Same as Pedesta l
22 cm (8.6 in.) fi t s 8. 75 i n. [5U] st andar d EIA 310D standard EIA 310D (RETMA)
63.8 cm (25.1 in.)
24.5 kg (54 LB) typical 28 kg (62LB) maximum
See requirements of specific cabi net Slides forward 68.6 cm (27 i n. ) then accessible from the top
1035° C (5095° F) Not tested
-4066° C (-40151° F) 11 c/hr (20 F/HR) 20–80%
20–80% 10–95% 20%/hr
Front Rear
2.44 Alpha Servers
Page 21
AlphaServer 800 Pedestal–Rackmount

Uninterruptable Power Supplies

Prestige 1250EXT
UPS offerings include EIA232 port for local or net work monit ori ng and pl ug-i n bat t ery e xt ension provi sions to inc re a se run time up to two hours. For complete protection, UPS products should be used with data line surge protectors and UPS monitoring software.
Solutions fo r Pedestal Sy st e m s
4N-AEABF-AA
Prestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 120V 6-foot cord with 5-15P plug, (4) 5-15R receptacle, 9 minutes battery at full UPS load.
4N-AEABF-BF
Prestige 1250EXT, 1250 VA/900W, 1 phase, 50/60 Hz, 200-240V in/ out sele c t abl e . Uses system power cord for detachable IE C320 i nput c onne ct i on at UPS. Include s (3) IEC320 10A output receptacles, (2) output jumpers with IEC320 connectors to system.
4N-AEABF-BB 4N-AEABF-BD 4N-AEAEO-PA 4N-AEAEO-PB 4N-AEWAR-G1
Extension pack for 120V 60 Hz models, up t o four pac ks at 30 mi nut es per pa c k supported Extension pack for 240V 50 Hz models, up t o four pac ks at 30 mi nut es per pa c k supported Hot-swap Power-Pass Module for 60 Hz UPS with (7) 5-15R Surge Protected outlets. Hot-swap Power-Pass Module for 50 Hz UPS with (6) IEC320, 10A surge protected outlets. Prestige 5 year on-site excha nge warrant y upgra de (US only).
Rackmount UPS
UPS Model Application Type Receptacle module 4N-AEAAH-FA 60Hz 4N-AEAAH-FB 50Hz 4N-AEAAJ-CL360Hz 4N-AEAAJ-CU 50Hz
Rackmount UPS, supports up to 5 systems 3kVA Custom RM Rackmount UPS, supports up to 5 systems 3kVA Custom RM Out of Cabinet UPS 6kVA Prestige Out of Cabinet UPS 6kVA Prestige
1
1
4
4
Included Included Included Hardwired
2
1. Factory installation must be specified at time of order. Up to two UPS systems, one UPS for up to 5 fully configured systems. Recommended UPS distribution option combines multiple UPS input plugs into a single L6-30P plug-in connec t ion to sim plify futu re UPS add-on. Or der 4NAEAAH-FF 60 Hz ; 4 N- AE AAH- FG 50 Hz ) .
2. Includes six IEC receptacle strips for connection to IEC plugs in cabinet.
3. 208-120/208V shown; order 4N-AEAAJ-CT for 240-120/240V models
4. Optional mobile stac ke r with sei smic m ounti ng provi sion for 6kVA Prestige (4N-AEACH-HD)
4N-AEAAJ-CL
Prestige 6 kVA (4 kW), single phase, 60Hz, 208-120/208V, 6 ft. c ord wit h L6-30P and (2) L 6-30R, (8) 5-15R receptacle. Modular hot-swap design with 7 minute battery at full UPS load, extendible plug and play batteries and receptacle provisions. Substitute -CT for 240V 240/120V operation.
4N-AEAAJ-CU
Prestige 6 kVA (4 kW) 50Hz package, single phase, 50Hz, 200-240V in/ out sele c ta bl e, ha rdwire d input/output.
4N-AEWAR-G3/G4
Prestige 5 year on-si t e e xc h ange wa rra nt y upgra de for 4N-AE AAH-CM/C T. G4 provides on-site remedial and start -up servi ce .
UPS Monitoring and Unattended Shutdown Software (for above UPS systems only) is included i n ServerW ORKS Kits shipping with all AlphaServers. Order Ca ble Kit sepa rat e ly.
4N-ONLIN-NT 4N-ONLIS-FE
Cable Kit for DIGIT AL UNIX Cable Kit for Open VMS
Network Management or multi system shutdown (via SNMP or ServerWORKS Manager) for DIGITAL UNIX and OpenVMS requires Network Adapter option.
60 Hz Applications 50 Hz Application Network Adapter Option 4N-AEAEO-DB/DD 4N-AEAEO-DB/DD 4N-AEAEO-DA/DC 4N-AEAEO-DB/DD
Prestige 3 kVA RM, DB=T wisted pai r ; DD=ThinWi r e Prestige 6 kVA and PUPS Plus UPS, DA/DB=Twisted pair; DC=ThinWire
Note: Multiple system shutdown via OpenVMS requires multi-port hardware option (RN-JMIU4-AB). Ports can be daisy
chained.
Alpha Servers 2.45