Cobra C6, C9, C6D, C6C, C6B Installation And Operation Manual

...
230635-6
For use in GB & IE
Gas Cooktops
Models:
C6 (600mm) C9 (900mm)
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. August 2011.
MANUFACTURED BY
Moffat Limited
Christchurch New Zealand
INTERNATIONAL BRANCHES
AUSTRALIA
Moffat Pty Limited E.Mail: vsales@moffat.com.au Main Office: (tel) (03) 9518 3888
(fax) (03 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): 0121 327 5575
(fax): 0121 327 9711 Spares: (tel): 0121 322 6640 (fax): 0121 327 9201 Service: (tel): 0121 322 6644 (fax): 0121 327 6257
UNITED STATES
Moffat Inc Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): 336 661 1556 (fax): 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): 366 661 1556 (fax): 336 661 1660
INTERNATIONAL
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
1
Contents
C6 Gas Cooktops 600 mm Wide.
C9 Gas Cooktops 900 mm Wide.
Part 1 Introduction ..................................................................................... 2
Part 2 Specifications .................................................................................. 3
Part 3 Installation ........................................................................................ 5
Part 4 Operation ......................................................................................... 8
Part 5 Cleaning and Maintenance......................................................... 10
Part 6 Gas Conversion .............................................................................13
Part 7 Replacement Parts List .................................................................. 17
We are confident that you will be delighted with your Cobra Series Cooktop, and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Cobra Series Appliance, there are two important things you can do.
Firstly:
Please read this instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation instructions or performance of your appliance, contact your Cobra Series dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
WARNING:
I
MPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS
APPLIANCE.
WARNING:
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION CAN BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
WARNING:
G
REAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE.
 THE APPLIANCE MUST NOT BE LEFT 'ON' UNATTENDED.  IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICEMAN TO ENSURE THAT CORRECT AND
SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
 DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
C
AUTION
:
This appliance is;

For professional use and is to be used by qualified persons only.

Only Qualified service persons are to carry out installation, servicing and gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
2
Part 1 Introduction
3
NOTE: (*)
* - The burner operating pressure is to be measured
at the manifold test point with two burners operating at full setting. The operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to the ‘Gas Conversion Instruction Sheet’ for this appliance for further details).
Gas Connection
Gas supply connection point is located at the rear of the appliance, approximately 130 mm from the right hand side and 630 mm from the floor. It is reached from beneath the appliance. (Refer to the ‘Dimensions’ section).
Connection is ¾" BSP male thread (for all models).
Part 2 Specifications
Model Covered in this Specification -
C6D [1] Cooktop 4 Open Burners. C6C [1] Cooktop 2 Burners + 300 mm Griddle. C6B Cooktop 600 mm Griddle.
C9D [1] Cooktop 6 Open Burners. C9C [1] Cooktop 4 Burners + 300 mm Griddle. C9B [1] Cooktop 2 Burners + 600 mm Griddle. C9A Cooktop 900 mm Griddle.
[1] - Open Burner Options:-
F - With Flame Failure Protection.
- Standard Burners.
General
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle arrangement and is available on adjustable front feet and robust rear rollers. Five griddle options with 2 models of base unit are available. Fitted with 'Individual Flame Failure' Option (F) for each open burner. (Standard for UK - Optional for Non UK) Griddles are fitted with pilot, flame failure and piezo ignition as standard. These cooktops have an easy clean stainless steel external finish.
Gas Supply Requirements
- Non - UK Only:
- UK Only:
Natural Gas
(G20)
Propane
(G31)
Open Burner
(each)
Griddle
(each 300 mm
section)
Open Burner
(each)
Griddle
(each 300 mm
section)
Heat Input (net)
Nominal
5.0 kW 5.0 kW 4.6 kW 5.0 kW
Reduced
1.7 kW 1.5 kW 1.5 kW 2.2 kW
Gas Rate (net)
Nominal
0.53 m3/hr 0.53 m3/hr 0.36 kg/hr 0.39 kg/hr
Reduced
0.18 m3/hr 0.16 m3/hr 0.12 kg/hr 0.17 kg/hr
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure
10 mbar (*)
Gas Connection
¾” BSP Male
28 mbar (*)
Natural Gas LP Gas (Propane)
Open Burner
(each)
Griddle
(each 300 mm
section)
Open Burner
(each)
Griddle
(each 300 mm
section)
Input Rate (N.H.G.C.)
22 MJ/hr
(20,000 Btu/hr)
20 MJ/hr
(18,956 Btu/hr)
22 MJ/hr
(20,000 Btu/hr)
20 MJ/hr
(18,956 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18.0”w.c.)
Burner Operating Pressure
1.0 kPa (*) (4.0” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection
¾” BSP Male
4
Part 2 Specifications
Dimensions
C6 - Gas Cooktop - 600 mm Wide.
C6D Model C6C Model C6B Model
C9 - Gas Cooktop - 900 mm Wide.
C9D Model C9C Model
C9B Model C9A Model
5
Part 3 Installation
Installation Requirements
NOTE: It is most important that this appliance is installed correctly and that the operation is correct before use. Installation shall comply with local, gas and health and safety requirements.
This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of health harmful substances in the room, that the appliance is installed in.
Cobra Series Cooktops are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National / Local codes covering gas and fire safety.
Australia:
AS 5601 - Gas Installations.
New Zealand:
NZS 5261 - Gas Installation.
United Kingdom:
Gas Safety (Installation and Use) Regulations
1998.
BS6173 - Installation of Catering Appliances.
BS5440 1 & 2 - Installation Flueing & Ventilation.
Ireland:
IS 820 - Non Domestic Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install equipment to the relevant codes and manufacturer’s specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only allowed to be adjusted by an Qualified service agent. They are not to be adjusted by the installation person.
Unpacking
 Remove all packaging and transit protection
from the appliance including all protective plastic coating from the exterior stainless steel panels.
 Check equipment and parts for damage.
Report any damage immediately to the carrier and distributor.
 Report any deficiencies to the distributor who
supplied the appliance.
 Check that the available gas supply is correct to
that shown on the rating plate located on the front upper right hand corner of the cooktop cabinet.
Combustible
Surface
Non Combustible
Surface
LH / RH
Side
250 mm (*) 0 mm
Rear 100 mm 0 mm
Loading...
+ 14 hidden pages