Clear-Com Encore
TM
PS-702 Two-Channel Intercom Power Supply
PS-702 Front view
The PS-702 can supply up to 2 amps at 30 volts DC to two channels in a
1-RU. This is sufficient to power up to 40 beltpacks,10 speaker stations, or
12 headset stations even under the most demanding conditions. Either
channel is capable of supplying up to 1.2 amps. The full current capacity
may be divided between the two channels.
Clear-Com’s advanced fail-safe design can sense the difference between
a short and an overload. Should a problem occur, each channel’s DC
overload/fault LED identifies the power supply’s response to the problem:
solid means an overload is sensed, but still powered; blinking means
power has been temporarily cut off to protect the power supply. If both
channels are operating and one channel has a fault, the other channel
will continue to operate normally. Power is restored to the shorted or
overloaded channel in a little as .5 seconds. With our exclusive Intelligent
Fault/Overload Sensing (IFOS), the PS-702 will dynamically increase this
time period before attempting another reset until the fault or overload
is corrected. This function significantly extends component life. And
there is no need to disconnect stations for the power supply to reset.
The unit also offers a convenient front panel intercom line jack, switchable
to either channel. This can be quite handy for trouble-shooting or simply a
time saver when quick access to either intercom line is needed. A 440Hz
tone is available on either or both channels and is indispensable for
system diagnostics and set-up. Simply flip a switch, set a level, and go.
Like all current Clear-Com Party-Line power supplies, two or more units
can be connected in parallel for increased system capacity or backup
redundancy. Multiple units will automatically synchronize their response
to power faults and overloads. The PS-702 can also operate as a singlechannel unit by using the front-panel A+B link switch.
Features:
• Provides up to 2 amps in only 1RU
• Supports up to 40 beltpacks, 10
speaker stations or 12 headset
stations
• Exclusive IFOS Intelligent Fault/
Overload Sensing for system reset
• Front panel intercom line jack
selectable for either channel
• A+B Link switch for single channel
operation
• Balanced program input with global
and individual channel controls
• Universal power supply accepts
100-240 VAC
• Overload/fault indicator for each
channel
• Built-in test tone generator for set
up and diagnostics
• Switchable terminations for each
channel
• Works in parallel with other power
supplies and main stations
• UL Listed and CE certified
www.clearcom.com
Clear-Com Encore
TM
PS-702 Two-Channel Intercom Power Supply
PS-702
PS-702 Back Panel
Technical Specifications:
dBu is an absolute measurement. 0 dBu is
referenced to 0.775 volts RMS
Program Line Input
Maximum Level before Clipping: >= 20dBu
Input Impedance: >= 5KΩ
Frequency Response
Program Input - Party-line: 200 - 20KHz ± 3dB
Max Distortion
Program Input - Party-line: <= 0.2%
Noise
Program Mic Input - Party-line: < -70dBu
Max Gain
Program Input - Party-line: >= -16dB
TERM
A
OFF
CHANNEL A
ON
Short Circuit Recovery Time
(1st short): <= 0.5 sec
Short Circuit Recovery Time: >= 20 shorts in
20sec) <= 20 sec
Station Capacity
Up to 40 RS-601 beltpacks or 10 speaker stations or
12 headset stations distributed over both channels
Rear Panel Connectors
Intercom: (6) XLR-3M (3 per
channel)
Program: (1) XLR-3F
AC Power: IEC 320 connector
Rear Panel Controls
(2) Termination On-Off switches
(1) Volume control
TERM
B
OFF
ON
CHANNEL B
PROGRAM INPUT
Environmental
32˚ - 122˚F (0˚ - 50˚C)
Dimensions
19 in. W x 1.75 in. H x 7.5 in. D
(483 mm x 44 mm x 190 mm)
Weight
6.16 lbs. (2.80 kg)
LEVEL
ADJUST
Min Gain
Program Input - Party-line: <= -20dB
Mains Power
Input Voltage Range: 100 - 240 VAC
Input Frequency Range: 50 - 60 Hz
Input Power: <= 60 VAC
Output Voltage: 30 VDC ± 0.5V
Output Current per Channel
(Continuous): 1.2 A
Output Current per Channel
(Peak): 2 A (Do not exceed
the 1.2A rating for
more than 2 seconds
per 1 minute period)
Front Panel Connectors
Intercom (1) XLR-3M
Front Panel Controls & Indicators
(1) Intercom channel switch
(1) A+B link switch
(2) Program switch
(2) Send level controls
(1) Test tone switch
(2) Overload LEDs
(1) Link indicator LED
(1) Power indicator LED
(1) Power switch
Notice About Specifications
While Clear-Com makes every attempt to maintain the
accuracy of the information contained in its product
manuals, that information is subject to change without
notice. Performance specifications included in this manual
are design-center specifications and are included for
customer guidance and to facilitate system installation.
Actual operating performance may vary.
www.clearcom.com
Americas & Asia 850 Marina Village Parkway, Alameda, CA 94501 USA Tel: +1.510.337.6600
Europe, Middle East & Africa 7400 Beach Drive, IQ Cambridge, Cambridge, CB25 9TP UK Tel: +44 1223 815000
China Rm 706, Tower B, Derun Building, YongAn Dongli A No. 3, Jianwai Ave, Chaoyang District, Beijing 1000223 China Tel: 008610-8528-8748
Canada Clear-Com Research, 1440 Hocquart Street, Suite 221, St.-Bruno, Quebec J3V 6E Canada Tel: +1.450.653.9669
© 2009, Vitec Group Communications. All rights reserved. ® Clear-Com is a registered trade mark of The Vitec Group plc.