This chapter provides instructions on how to install your Cisco Catalyst Blade Switch 3130 for Dell and
the Cisco Catalyst Blade Switch 3032 for Dell, referred to as the switch. The switch modules are installed
in the Dell Modular Server Chassis, referred to as the server chassis, a system that supports up to sixteen
server modules and up to six Ethernet switches. You install the switch in one of the chassis I/O module
bays on the rear panel of the server chassis.
This chapter also describes how to interpret the power-on self-test (POST) that ensures proper operation
and how to make connections to the switch module.
Read the topics and perform the procedures in this order:
• Safety Warnings, page 2-1
• Dell Modular Server Chassis Architecture, page 2-3
• Installing the Switch in the Server Chassis, page 2-4
• Configuring the Switch, page 2-7
• Managing the Switch, page 2-15
• Planning and Creating a Switch Stack (Only 3130G-S and 3130X-S Switches), page 2-17
• Installing Devices in the 10-Gigabit Ethernet Slots, page 2-21
• Connecting to 10/100/1000 Ethernet Ports, page 2-27
• Where to Go Next, page 2-27
Safety Warnings
These warnings are translated into several languages in the Regulatory Compliance and Safety
Information for the Cisco Catalyst Blade Switch 3000 Series for Dell that ships with the product. The
EMC regulatory statements are also included in that guide.
Warning
OL-13269-01
To prevent the switch from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of 104°F (40°C). To prevent airflow restriction, allow at least
3 inches (7.6 cm) of clearance around the ventilation openings.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
Statement 17B
2-1
Page 2
Safety Warnings
Chapter 2 Switch Installation
Warning
Warning
Warning
Warning
Warning
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals.
Ethernet cables must be shielded when used in a central office environment.
Statement 43
Statement 171
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Read the installation instructions before connecting the system to the power source.
Class 1 laser product.
Statement 1008
Statement 1004
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Warning
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
10/100/1000 Ethernet
Installation of the equipment must comply with local and national electrical codes.
Statement 1044
Statement 1074
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-2
OL-13269-01
Page 3
Chapter 2 Switch Installation
Dell Modular Server Chassis Architecture
The six chassis I/O module bays are on the rear panel (see Figure 2-1).
Figure 2-1Dell Modular Server Chassis Rear Panel
2
1
!
3
4
5
!
STK
B
A
18X
17X
6
!
7
8
9
10
!
!
Dell Modular Server Chassis Architecture
20X
19X
22
21
X2-1
!
!
24
23
X2-2
W
S
-
C
B
S
313
0
X
-S
!
M
M
S
S
M
S
T
Y
B
T
C
S
R
R
K
T
M
O
D
E
C
O
N
S
O
L
E
!
!
!
!
!
!
!
!
!
11
!
!
12
!
250199
1Dell server chassis7I/O module bay C2
2Primary CMC
3Switch installed in I/O module bay A19I/O module bay A2
4I/O module bay B110 Secondary CMC module
5I/O module bay C111 Fan modules
6Optional iKVM
1. CMC: Chassis Management Controller.
2. This module is optional.
3. iKVM: integrated keyboard video mouse.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
1
module
3
module
8I/O module bay B2
2
12 Power supplies
2-3
Page 4
Installing the Switch in the Server Chassis
Installing the Switch in the Server Chassis
See the getting started guide that ships on CD-ROM with the product for information about what ships
with your switch.
Before you install the switch in the server chassis, consider these points:
• Review and become familiar with the safety and handling guidelines specified in the Product
Information Guide.
• Review the Regulatory Compliance and Safety Information for the Cisco Catalyst Blade Switch
3000 Series for Dell that ships with this product.
• If you plan to create a switch stack, review the “Planning and Creating a Switch Stack (Only
3130G-S and 3130X-S Switches)” section on page 2-17 before you install the switch and run the
initial configuration setup program.
• To help ensure proper cooling and system reliability, keep these points in mind:
–
Each chassis I/O module bay must contain either a module or an input/output module (IOM)
blank.
–
Fan modules must be operating in the fan module bays to ensure proper cooling of the switch
modules. See the Dell server chassis documentation for information about how to ensure that
the modules are properly cooled.
–
When you remove a hot-swap module, you must replace it with an identical module or an IOM
blank within 1 minute of removal.
Chapter 2 Switch Installation
–
You can install the switch into any of the module bays. If you install a switch in the B or C
module bay, the Ethernet mezzanine cards must be installed in the blade server.
–
The dust covers should always remain in place unless a module is installed in the slot.
CautionTo prevent electrostatic-discharge (ESD) damage when you install the switch, follow your normal board
and component handling procedures.
When you install a switch, you do not need to power down the server chassis.
Be sure to observe these requirements:
• For copper Ethernet ports, cable lengths from the switch module to connected devices can be up to
328 feet (100 meters).
• See the documentation for the SFP module for more information about cable specifications for the
SFP module connections. Also see the “SFP Module Cable Specifications” section on page B-6.
Each port must match the wave-length specifications on the other end of the cable, and the cable
must not exceed the stipulated cable length for reliable communications.
When you use shorter lengths of single-mode fiber-optic cable, you might need to insert an inline
optical attenuator in the link to avoid overloading the receiver.
• Operating environment is within the ranges listed in Appendix A, “Technical Specifications.”
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent
lighting fixtures. Make sure the cabling is safely away from other devices that might damage
the cables.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-4
OL-13269-01
Page 5
Chapter 2 Switch Installation
Follow these steps to install the switch into the server chassis:
Step 1Obtain and make note of this information from your network administrator before you begin the switch
installation:
• Switch IP address
• Subnet mask (IP netmask)
• Default gateway (router)
• Enable secret password (encrypted)
• Enable password (not encrypted)
• Telnet password
• SNMP community strings (optional)
Step 2Select a chassis I/O module bay in which to install the switch. Follow the prerequisites listed in the “Dell
Modular Server Chassis Architecture” section on page 2-3.
Step 3Remove the IOM blank from the selected bay, and store it for future use.
Step 4If you have not already done so, touch the static-protective package that contains the switch to an
unpainted metal part of the server chassis for at least 2 seconds.
Installing the Switch in the Server Chassis
Step 5Remove the switch from its static-protective package.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-5
Page 6
Installing the Switch in the Server Chassis
Step 6Ensure that the release latch on the switch is in the open position or perpendicular to the module
(see Figure 2-2):
Figure 2-2Release Latch in Open Position
Chapter 2 Switch Installation
STK
B
A
18X
17X
20X
19X
22
21
X2-1
24
23
X2-2
WS-CBS
3130X-S
M
M
S
S
M
S
T
Y
B
T
C
S
R
R
K
T
M
O
D
E
C
O
N
S
O
LE
250200
Step 7
Slide the switch into the appropriate bay until it stops.
Step 8Push the release latch on the front of the switch to the closed position.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-6
OL-13269-01
Page 7
Chapter 2 Switch Installation
Figure 2-3 shows the switch being inserted into the server chassis.
Figure 2-3Inserting the Switch into the Server Chassis
3
Configuring the Switch
2
!
!
STK
B
A
1
18X
17X
20X
19X
22
21
X2-1
24
23
X2-2
WS-C
BS3130X-S
M
M
S
S
M
S
T
Y
B
T
C
S
R
R
K
T
M
O
D
E
C
O
N
S
O
LE
!
!
!
!
!
!
!
!
!
!
1Switch3Release latch
2Server chassis
Configuring the Switch
To run the system configuration dialog, you must first connect the switch to a PC to run a terminal
emulation program. You can connect the switch to the PC either through the switch console port or
through the CMC console port. Instructions for these procedures are included in this section.
If you connect to the switch through the CMC, the switch console port is disabled. After you have
completed the configuration procedure, you must use the disconnect command to close the active
console port and re-enable the switch console port. Enter logout to log out of the switch, then enter
Ctrl \ to disconnect the CMC from the switch.
!
!
!
!
!
250201
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-7
Page 8
Configuring the Switch
Follow one of these procedures:
• To run the terminal emulation program through the switch console port, go to “Connecting through
the Switch Console Port” section on page 2-8.
• To run the terminal emulation program through the CMC port, go to “Connecting through the CMC”
section on page 2-9.
Connecting through the Switch Console Port
Follow these steps when connecting through the switch console port:
Step 1Connect one end of the console cable to the switch console port. Connect the other end of the cable to
the serial port of the PC that is running the terminal emulation application. (See Figure 2-4.)
Figure 2-4Connecting To the Switch Console Port
Chapter 2 Switch Installation
!
WS-CBS3130X-S
!
M
M
S
S
M
S
T
Y
B
T
C
S
R
R
K
T
MODE
CONSOLE
!
!
250202
Step 2Start the terminal emulation session so that you can see the output display from the power-on self-test
(POST). The terminal-emulation software—a PC application such as Hyperterminal or
ProcommPlus—makes communication between the switch and your PC or terminal possible.
Configure the baud rate and character format of the PC or terminal to match these console port default
characteristics:
• 9600 baud
• 8 data bits
• 1 stop bit
• No parity
• None (flow control)
Step 3Go to the “Waiting for POST to Complete” section on page 2-10 to finish configuring the switch.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-8
OL-13269-01
Page 9
Chapter 2 Switch Installation
Connecting through the CMC
Follow these steps when connecting through the CMC:
Step 1Connect one end of a DB-9 null-modem or crossover cable to the RS-232 console serial port of the CMC.
Connect the other end of the cable to the RS-232 console serial port of the PC.
Step 2On the PC terminal emulation program:
a. Set the data format to 8 data bits, 1 stop bit, and no parity.
b. Set the terminal emulation speed to 115200 baud.
c. Set Flow Control to none.
d. Under Properties, select VT100 for Emulation mode.
e. Select Terminal keys for Function, Arrow, and Ctrl keys. Ensure that the setting is for Terminal keys
(not Windows keys).
When using HyperTerminal with Microsoft Windows 2000, ensure that you have Windows 2000 Service
Pack 2 or later installed. With Windows 2000 Service Pack 2, the arrow keys function properly in the
HyperTerminal VT100 emulation. Go to www.microsoft.com for information on Windows 2000 service
packs.
Step 3On the console monitor, the CMC application displays a login screen. Log in by using these defaults:
username root
password calvin
The CMC command-line interface (CLI) command prompt CMC: appears.
Configuring the Switch
NoteIf the server chassis is off, use this command to power it on:
racadm chassisaction -m chassis powerup
The switch inserted into the chassis I/O bay automatically powers on when the server chassis
powers on. For more information on configuring the server chassis by using the CLI, see the Dell Remote Access Controller/Modular Chassis User's Guide.
Power-cycle the switch by using this command:
racadm chassisaction -m switch-N powercycle
where N is the chassis I/O module bay number in which the switch is inserted.
Module BaySubstitute for N
A11
A22
B13
B24
C15
C26
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-9
Page 10
Configuring the Switch
Step 4Redirect the CMC console to the switch internal serial console interface. Enter this command at the CMC
command prompt:
connect switch-N
where N is the chassis I/O module bay number in which the switch is inserted.
To return to the command prompt, press this key sequence:
Enter Ctrl \ (Press Enter, and press the Control key and the backslash key together.)
Step 5Go to the “Waiting for POST to Complete” section on page 2-10 to finish configuring the switch.
Waiting for POST to Complete
Follow these steps to verify that POST completes successfully:
Step 1Wait for the switch to complete the POST. During POST, the LEDs blink while tests verify that the
switch functions properly. Wait for the switch to complete POST, which can take several minutes.
Step 2Verify that POST has completed by confirming that the SYST LED remains green. If the switch fails
POST, the SYST LED turns amber. See Figure 1-1 on page 1-2 for the location of the SYST LED.
POST errors are usually fatal. Call Cisco Customer Support immediately if your switch fails POST.
Chapter 2 Switch Installation
Step 3Wait for the switch to complete flash initialization. When you see the prompt Press Return to Get
Started!
If you do not see the prompt
, press Return or Enter.
Press Return to Get Started!, be sure that you have set the baud rate
on the terminal to 9600 baud.
Step 4Make sure that the System Status/ID LED on the switch is off. This means that the switch is operating
properly.
Step 5See the “Completing the Initial Configuration” section on page 2-10 for instructions on setting up and
initially configuring the switch.
Step 6If the switch obtains an IP address through the Fa0 port, you can use the device manager to configure
the switch. See the “Using the Device Manager to Configure the Switch” section on page 2-13.
Completing the Initial Configuration
Follow these steps to complete the setup program and to create an initial configuration for the switch.
For information about automatically configuring the switch, see the “Assigning the Switch IP Address
and Default Gateway” chapter in the switch configuration guide on Cisco.com.
Step 1After you have pressed Enter or Return after the prompt to start the initial configuration setup program,
enter yes at these prompts:
Would you like to terminate autoinstall? [yes]: yes
--- System Configuration Dialog --Continue with configuration dialog? [yes/no]: yes
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-10
OL-13269-01
Page 11
Chapter 2 Switch Installation
At any point you may enter a question mark '?' for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'.
Basic management setup configures only enough connectivity
for management of the system, extended setup will ask you
to configure each interface on the system
Would you like to enter basic management setup? [yes/no]: yes
Configuring global parameters:
Step 2Enter a hostname for the switch after the prompt, and press Return.
The hostname is limited to 20 characters. Do not use -n, where n is a number, as the last character in a
host name for any switch.
Step 3Enter an enable secret password, and press Return.
The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive,
allows spaces, but ignores leading spaces. The secret password is encrypted, and the enable password is
in plain text.
Step 4Enter an enable password, and press Return.
Configuring the Switch
Step 5Enter a virtual terminal (Telnet) password, and press Return.
The password can be from 1 to 25 alphanumeric characters, is case sensitive, allows spaces, but ignores
leading spaces.
Step 6(Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts.
1. To configure SNMP later, press Return (which applies the default of no). If you accept the default,
you can configure SNMP later through the CLI.
Configure SNMP Network Management? [no]:
2. To configure SNMP now, enter yes.
Configure SNMP Network Management? [no]: yes
Community string [public]: public
Step 7Enter the interface name (physical interface or VLAN name) of the interface that connects to the
management network, and press Return.
Enter vlan1 for the interface name at this prompt.
Step 8To configure the interface, enter Ye s after the prompt, and then enter the switch IP address and subnet
mask. Press Return.
The IP address and subnet mask shown here are examples:
Configuring interface Vlan1:
Configure IP on this interface? [yes]:
IP address for this interface [10.0.0.1]:
Subnet mask for this interface [255.255.255.0] : 255.255.255.0
Class A network is 10.0.0.1, 21 subnet bits; mask is /21
Step 9Enter no when the prompt asks you if you would like to enable the switch as a cluster command switch.
This switch will be a standalone switch.
Would you like to enable as a cluster command switch? [yes/no]: no
NoteClustering is not supported.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-11
Page 12
Configuring the Switch
Chapter 2 Switch Installation
You have now completed the initial configuration of the switch, and the switch displays its initial
configuration. An example of the output is shown here:
The following configuration command script was created:
hostname switch1
enable secret 5 $1$cagJ$e4LP91PNazfdADoNAZm6y0
enable password enable_password
line vty 0 15
password terminal-password
snmp-server community public
!
!
interface Vlan1
no shutdown
ip address 10.0.0.1 255.255.255.0
!
interface FastEthernet0
shutdown
no ip address
!
interface GigabitEthernet1/0/1
!
interface GigabitEthernet1/0/2
!
. . . (output truncated)
!
interface TenGigabitEthernet1/0/1
!
interface TenGigabitEthernet1/0/2
!
end
Step 10These choices appear:
[0] Go to the IOS command prompt without saving this config.
[1] Return back to the setup without saving this config.
[2] Save this configuration to nvram and exit.
If you want to save the configuration and use it the next time the switch reboots, save it
in NVRAM by selecting option 2.
Enter your selection [2]:2
Make your selection, and press Return.
Step 11Disconnect the server chassis serial port or the switch console port from the PC. See the “Managing the
Switch” section on page 2-15 for information about configuring and managing the switch.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-12
OL-13269-01
Page 13
Chapter 2 Switch Installation
Using the Device Manager to Configure the Switch
Follow these steps to set up the switch through the device manager. In a browser window, enter the
IP address that the Fa0 port assigned to the switch. Before you complete the setup program, obtain the
default gateway IP address and the switch password from your system administrator. You can configure
these optional parameters through the Express Setup program:
• Telnet access password
• Names of the SNMP read and write community strings if you are going to use a
network-management program like CiscoWorks
• Host name, system contact, and system location
• System time, time zone, Daylight Savings Time enable
Step 1On the left side of the device manager GUI, choose Configuration > Express Setup.
The Express Setup page appears (see Figure 2-5 and Figure 2-6). (Close or minimize the device manager
Help window.)
Figure 2-5Express Setup Page
Configuring the Switch
Step 2
OL-13269-01
Enter this information in the Network Settings fields.
–
In the Default Gateway field, enter the IP address for the default gateway (router).
–
In the Switch Password field, enter your password. The password can be from 1 to 25
alphanumeric characters, can start with a number, is case sensitive, allows embedded spaces,
but does not allow spaces at the beginning or end.
In the Confirm Switch Password field, enter your password again.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-13
Page 14
Configuring the Switch
Chapter 2 Switch Installation
You can enter the Optional Settings information now or enter it later by using the device manager
interface.
Figure 2-6Advanced Settings Tab
Step 3In the Host Name field, enter a name for the switch module. The host name is limited to 31 characters;
embedded spaces are not allowed.
Step 4In the System Date and System Time fields, enter the current date and time, or use the down arrows to
select them.
Step 5In the Time Zone field, use the down arrow to choose your time zone.
Step 6Click Enable in the Daylight Savings Time field to enable this feature.
Step 7In the Telnet Access field, click Enable if you are going to use Telnet to manage the switch module by
using the CLI. If you enable Telnet access, you must enter a Telnet password.
NoteIf you plan to create a switch stack, enable Telnet access so that you can use the CLI to set this
switch to the highest priority (usually 15). See the “Planning and Creating a Switch Stack (Only
3130G-S and 3130X-S Switches)” section on page 2-17 for more information about creating a
switch stack.
Step 8In the Telnet Password field, enter a password. The Telnet password can be from 1 to 25 alphanumeric
characters, is case sensitive, allows embedded spaces, but does not allow spaces at the beginning or end.
In the Confirm Telnet Password field, re-enter the Telnet password.
Step 9In the SNMP field, click Enable to enable Simple Network Management Protocol (SNMP). Enable
SNMP only if you plan to manage switches by using CiscoWorks 2000 or another SNMP-based
network-management system.
Step 10If you enable SNMP, you must enter a community string in the SNMP Read Community field, the
SNMP Write Community field, or both. SNMP community strings authenticate access to MIB objects.
Embedded spaces are not allowed in SNMP community strings. When you set the SNMP read
community, you can access SNMP information, but you cannot change it. When you set the SNMP write
community, you can both access and change SNMP information.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-14
OL-13269-01
Page 15
Chapter 2 Switch Installation
Step 11In the System Contact field, enter the name of the person who is responsible for the switch module. In
the System Location field, enter the wiring closet, floor, or building where the switch module is located.
Step 12Depending on which software license you choose, you can enable IPv6 in the IPv6 Settings area.
• Click Enable IPv6 to enable it.
• In the Interface column, choose the interface for which you want to set an IPv6 address, and
complete the other fields in this table.
Step 13Click Submit to save your settings, or click Cancel to clear your settings.
You can close this window.
Configuring the Switch Stack Master
If you plan to create a switch stack, we recommend that you set the first configured switch as the stack
master. To do this, you must assign the highest priority value to that switch. To assign a priority value
after you have installed and initially configured the first switch, follow these steps:
Managing the Switch
Step 1Launch a Telnet session.
Step 2Enter enable.
Step 3Enter configure terminal.
Step 4Enter switch 1 priority 15.
Step 5At the prompt, press Return.
Step 6Enter end to exit this mode.
Step 7Enter copy running-configuration startup-configuration to save this setting.
Step 8At the prompt, press Return.
Step 9To verify that this switch is set as the master, enter the show switch user EXEC command.
For more information about creating switch stacks, see the “Planning and Creating a Switch Stack (Only
3130G-S and 3130X-S Switches)” section on page 2-17.
Managing the Switch
After completing the initial setup and configuration steps, use the CLI, the device manager, or other
management options described in this section for further configuration.
Using the CLI
After setting up and installing the switch in your network, you can enter Cisco IOS commands and
parameters through the CLI. Access the CLI either by connecting your PC directly to the switch console
port or through a Telnet session from a remote PC or workstation. You can also access the CLI through
the server chassis serial console port of the active Dell CMC. For more information, see the hardware
installation guide on Cisco.com.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-15
Page 16
Managing the Switch
Using the Device Manager
The simplest way to manage the switch is by using the device manager that is in the switch memory. This
is an easy-to-use web interface that offers quick configuration and monitoring. You can access the device
manager from anywhere in your network through a web browser. The device manager dashboard is
shown in Figure 2-7.
Figure 2-7Device Manager Dashboard
Chapter 2 Switch Installation
Follow these steps to access the device manager:
Step 1Launch a web browser on your PC or workstation.
Step 2Enter the switch IP address in the web browser, and press Enter. The device manager page appears.
Step 3Use the device manager to perform basic switch configuration and monitoring. See the device manager
online help for more information.
Other Management Options
You can use SNMP management applications such as CiscoWorks. You also can manage it from an
SNMP-compatible workstation that is running platforms such as SunNet Manager.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-16
OL-13269-01
Page 17
Chapter 2 Switch Installation
Planning and Creating a Switch Stack (Only 3130G-S and 3130X-S Switches)
Planning and Creating a Switch Stack (Only 3130G-S and
3130X-S Switches)
A switch stack is a set of up to nine stacking-capable switches that are connected through their StackWise
Plus ports. One switch controls the operation of the stack and is called the stack master. The stack master
and the other switches in the stack are stack members. Layer 2 and Layer 3 protocols present the entire
switch stack as a single entity to the network. Stacking is optional.
When switches are not stacked, each acts as a standalone switch. For general concepts and procedures
to manage switch stacks, see the switch software configuration guide and command reference on
Cisco.com.
CautionThe Cisco Catalyst Blade Switch 3130 for Dell does not support switch stacks with other types of blade
switches as members. Combining the Cisco Catalyst Blade Switch 3130 for Dell with other types of
blade switches in a switch stack might cause the switch to work improperly or to fail.
Before you connect the switches in a stack, keep in mind these stacking guidelines:
• You should install the stack master switch and run the initial setup program on that switch before
you connect the StackWise Plus cables to other stack members. We recommend that you assign the
highest priority value to the switch that you prefer to be the stack master. This ensures that the switch
is re-elected as stack master if a re-election occurs. As you add new switches to the stack, they
automatically become stack members.
To assign a priority value after you have installed and initially configured the first switch, see the
“Configuring the Switch Stack Master” section on page 2-15.
• When you connect the StackWise Plus cables and create a stack, you can communicate with the
master switch internal Ethernet management port (Fa0) port, but not the Fa0 ports of the member
switches. Only one Fa0 interface can be active, and that interface is the one on the active stack
master.
• For conditions that might cause a stack master re-election or to manually elect the stack master, see
the “Managing Switch Stacks” chapter in the switch software configuration guide on Cisco.com.
• You can stack any combination of up to nine Catalyst 3130G-S and 3130X-S switches. You can stack
only the Catalyst 3130 switches; other switches cannot be stacked.
• Before installation, verify the StackWise Plus cable length. Depending on your configuration, you
might need different sized cables. If you do not specify the length of the StackWise Plus cable when
you order your product, the 1-meter cable is supplied. If you need the 0.5-meter cable or the 3-meter
cable, you can order these StackWise Plus cables from your sales representative:
–
CAB-STK-E-0.5M= (0.5-meter cable)
–
CAB-STK-E-1M= (1-meter cable)
–
CAB-STK-E-3M= (3-meter cable)
For switch dimensions and additional stacking guidelines, see the switch hardware installation guide on
Cisco.com. For concepts and procedures to manage switch stacks, see the switch software configuration
guide on Cisco.com.
To create a switch stack:
Step 1Install the member switches if you have not already done so.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-17
Page 18
Planning and Creating a Switch Stack (Only 3130G-S and 3130X-S Switches)
Step 2Connect the StackWise Plus cables as described in the “Planning and Creating a Switch Stack (Only
3130G-S and 3130X-S Switches)” section on page 2-17.
Step 3Configure the member switches through the master switch by using the CLI.
Stack Cabling Configurations
This section describes the recommended configurations for stacking the switches by using the supplied
1-meter StackWise cable.
In this example, the stack uses the 1-meter StackWise Plus cable to make redundant connections between
two Catalyst 3130 switches in a single chassis (see Figure 2-8).
Figure 2-8Stacking Two Switch Modules in a Single Blade Server to Create One Stack
Chapter 2 Switch Installation
24
WS-CBS3130X-S
STK
B
A
23
X2-2
24
WS-CBS3130X-S
STK
B
A
23
X2-2
250291
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-18
OL-13269-01
Page 19
Chapter 2 Switch Installation
Figure 2-9 is an example of a recommended configuration in which eight switch modules create a switch
stack in four blade servers.
Figure 2-9Stacking Eight Switch Modules in Four Blade Servers to Create One Stack
Planning and Creating a Switch Stack (Only 3130G-S and 3130X-S Switches)
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
24
23
X2-2
WS-CBS3130X-S
250292
2-19
Page 20
Planning and Creating a Switch Stack (Only 3130G-S and 3130X-S Switches)
Figure 2-10 is an example of a recommended configuration in which eight switch modules create two
separate switch stacks in four blade servers. This configuration provides redundant connections.
Figure 2-10Stacking up to Eight Switch Modules in Four Server Chassis to Create Two Stacks
Chapter 2 Switch Installation
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
24
23
X2-2
WS-CBS3130X-S
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-20
24
23
X2-2
WS-CBS3130X-S
250293
OL-13269-01
Page 21
Chapter 2 Switch Installation
Connecting the StackWise Plus Cables
Follow these steps to connect the StackWise Plus cables:
Step 1Remove the dust covers from the StackWise Plus cables, and store them for future use.
Step 2Verify that cables are aligned as shown in Figure 2-11.
Figure 2-11Inserting the StackWise Plus Cable
18X
20X
22
Installing Devices in the 10-Gigabit Ethernet Slots
STK
B
A
17X
19X
21
250315
Step 3
Insert one end of the cable into the StackWise Plus port on the front panel of the switch. Insert the other
end of the cable into the connector on the other switch (see Figure 2-11).
Always use a Cisco-approved StackWise Plus cable to connect the switches.
When you remove the StackWise Plus cables from the connectors, replace the dust covers to protect them
from dust.
CautionRemoving and installing the StackWise Plus cable can shorten its useful life. Do not remove and insert
the cable more often than is absolutely necessary.
Installing Devices in the 10-Gigabit Ethernet Slots
These sections describe how to install and remove X2 transceiver modules, Cisco TwinGig Converter
Modules (also known as converter modules), and SFP modules:
CautionDo not remove the dust plugs from the fiber-optic X2 transceiver modules or SFP modules or the rubber
caps from the fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the
module ports and cables from contamination and ambient light.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-21
Page 22
Chapter 2 Switch Installation
Installing Devices in the 10-Gigabit Ethernet Slots
CautionDo not install or remove an X2 or SFP module with the cables attached because of the potential damage
to the cables, the cable connectors, or the optical interfaces in the modules. Disconnect all cables before
removing or installing the module.
CautionRemoving and installing an X2 or SFP module can shorten its useful life. Do not remove and insert any
X2 or SFP module more often than is absolutely necessary.
CautionTo prevent ESD damage, follow your normal board and component handling procedures when
connecting cables to the switch and other devices.
Installing X2 Transceiver Modules and Cisco Converter Modules
These sections describe how to install and remove X2 transceiver modules and the converter modules in
the switch module 10-Gigabit Ethernet module slots.
NoteDo not remove the dust cover from the converter module until you are ready to install an X2 transceiver
or SFP modules. A module or dust cover must be installed in the slot at all times.
The Cisco Catalyst Blade Switch 3032G and 3130G support only the Cisco TwinGig Converter Modules,
not the X2 transceiver modules.
Use only Cisco X2 transceiver modules and Cisco TwinGig Converter Modules with the switch module.
Each Cisco transceiver and converter module has an internal serial EEPROM that is encoded with
security information. This encoding provides a way for Cisco to identify and validate that the module
meets the requirements for the switch.
For more information about installing, removing, cabling, and troubleshooting X2 transceiver modules,
see the module documentation that shipped with your device. For module cable specifications, see
Appendix B, “Connector and Cable Specifications.”
Installing a Transceiver or Converter Module
When you install or remove the converter module, the mode on the switch changes from 10-Gigabit
Ethernet to Gigabit Ethernet or the reverse. During this mode change, data traffic on the other switch
module uplink ports (X2 transceiver or SFP module ports) might temporarily stop. When you install or
remove an X2 transceiver or SFP module, traffic delay does not occur.
To insert an X2 transceiver module or a converter module, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2Remove the transceiver or converter module from its protective packaging.
Step 3Align the transceiver module in the module slot (Figure 2-12 and Figure 2-13).
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-22
OL-13269-01
Page 23
Chapter 2 Switch Installation
CautionVerify the correct orientation of your module before inserting it into the slot. Incorrect insertion can
damage the module.
Step 4Slide the transceiver or converter module into the opening until the back of its faceplate is flush with the
switch module faceplate.
Figure 2-12Installing X2 Transceiver Modules
Installing Devices in the 10-Gigabit Ethernet Slots
STK
B
A
18X
20X
22
24
21
X2-1
23
X2-2
17X
19X
250309
CautionDo not install the converter module with SFP modules or cables installed. Always remove any cables and
modules before installing the converter module in the slot.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-23
Page 24
Installing Devices in the 10-Gigabit Ethernet Slots
Figure 2-13Installing Converter Modules
Chapter 2 Switch Installation
STK
B
A
Removing a Module
To remove an X2 transceiver module or a converter module, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2For X2 transceiver modules, disconnect the cables from the module. For fiber-optic modules, install the
optical bore dust plugs.
18X
20X
17X
21
X2-1
23
X2-2
19X
250288
22
24
2-24
Step 3For converter modules, disconnect the cables from the SFP module. Remove the SFP modules from the
converter module.
CautionDo not remove the converter module with SFP modules or cables installed. Always remove any cables
and modules before removing the converter module from the slot.
Step 4Carefully pull on the X2 module sleeve, or pinch the tabs on the converter module to disengage it from
the slot. Grasp the edges of the module, and carefully slide it out of the slot.
Step 5Reinstall the dust cover in the 10-Gigabit Ethernet slot.
CautionThe dust covers should always remain in place unless a module is installed in the slot.
Step 6Place the module in an antistatic bag or other protective environment.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
Page 25
Chapter 2 Switch Installation
Installing SFP Modules
This section describes how to install and remove SFP modules in the 10-Gigabit Ethernet slots. To use
SFP modules in the switch, you must have a converter module installed in a 10-Gigabit Ethernet slot.
CautionTo avoid damage to the converter module, first install the converter module in the switch 10-Gigabit
Ethernet slot before installing the SFP modules.
See the switch module release notes on Cisco.com for the list of SFP modules that the switch module
supports. Use only Cisco SFP modules on the switch. Each Cisco module has an internal serial EEPROM
that is encoded with security information. This encoding provides a way for Cisco to identify and
validate that the SFP module meets the requirements for the switch.
For more information about installing, removing, cabling, and troubleshooting SFP modules, see the
module documentation that shipped with your device. For module cable specifications, see Appendix B,
“Connector and Cable Specifications.”
Installing an SFP Module
Installing Devices in the 10-Gigabit Ethernet Slots
To insert an SFP module into a converter module slot, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2Remove the Cisco TwinGig Converter Module dust cover and save.
NoteThe dust cover is an integral part of the airflow function. If you remove the SFP module, you must
replace it with the saved dust cover.
Step 3Install the converter module in the 10-Gigabit Ethernet module slot as described in “Installing a
Transceiver or Converter Module” section on page 2-22.
Step 4Find the send (TX) and receive (RX) markings that identify the top side of the SFP module.
On some SFP modules, the send and receive (TX and RX) markings might be replaced by arrows that
show the direction of the connection, either send or receive (TX or RX).
Step 5If the SFP module has a bale-clasp latch, move it to the open, unlocked position.
Step 6Align the SFP module in the converter module opening. When installing a module in the upper module
slot (slot 1), position the SFP module face up. When using the lower module slot (slot 2), position the
SFP module face down.
Step 7Slide the SFP module into the opening until you feel the connector on the module snap into place
(Figure 2-14).
Step 8If the module has a bale-clasp latch, close it to lock the SFP module in place.
Step 9Remove the SFP dust plugs and save. Install the SFP cables.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-25
Page 26
Installing Devices in the 10-Gigabit Ethernet Slots
Figure 2-14Converter Module with SFP Modules Installed
22
21
X2-1
3
Chapter 2 Switch Installation
1
4
3
4
3
4
3
4
1Converter modules3Send (TX) optical bore
2SFP modules 4Receive (RX) optical bore
Removing an SFP Module
24
23
X2-2
WS-CBS3130X-S
2
1
2
250407
To remove an SFP module from a module slot, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2Disconnect the cable from the SFP module. For reattachment, note which cable connector plug is send
(TX) and which is receive (RX).
Step 3Insert a dust plug into the optical ports of the SFP module to keep the optical interfaces clean.
Step 4If the module has a bale-clasp latch, pull the bale out and down to eject the module. If the bale-clasp
latch is obstructed and you cannot use your index finger to open it, use a small, flat-blade screwdriver
or other long, narrow instrument to open the bale-clasp latch.
Step 5Grasp the SFP module, and carefully remove it from the module slot.
Step 6Place the removed SFP module in an antistatic bag or other protective environment.
CautionCategory 5e and Category 6 cables can store high levels of static electricity. Always ground the cables
to a suitable and safe earth ground before connecting them to the switch or other devices.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-26
OL-13269-01
Page 27
Chapter 2 Switch Installation
Connecting to 10/100/1000 Ethernet Ports
The 10/100/1000 Ethernet ports use standard RJ-45 connectors with Ethernet pinouts. The maximum
cable length is 328 feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires Category 5,
Category 5e, or Category 6 UTP cable. The 10BASE-T traffic can use Category 3 or Category 4 cable.
The autonegotiation feature is enabled by default on the switch. At this setting, the switch ports
configure themselves to operate at the speed of attached device. If the attached device does not support
autonegotiation, you can explicitly set the switch port speed and duplex parameters. To maximize
performance, either let the ports autonegotiate both speed and duplex, or set the port speed and duplex
parameters on both ends of the connection.
For simplified cabling, the automatic medium-dependent interface crossover (auto-MDIX) feature is
enabled by default on the switch. With auto-MDIX enabled, the switch detects the required cable type
for copper Ethernet connections and configures the interface accordingly. Therefore, you can use either
a crossover or a straight-through cable for connections to a switch 10/100/1000 Ethernet port regardless
of the type of device on the other end of the connection.
See the switch software configuration guide or the switch command reference on Cisco.com for more
information about enabling or disabling autonegotiation and auto-MDIX.
If auto-MDIX is disabled, use the guidelines in Tab l e 2-1 to select the correct cable for connecting the
switch 10/100/1000 Ethernet ports to other devices. See the “Cable and Adapter Specifications” section
on page B-4 for cable-pinout descriptions.
Connecting to 10/100/1000 Ethernet Ports
Table 2-1Recommended Ethernet Cables (When Auto-MDIX is Disabled)
DeviceCrossover Cable
Switch to switchYesNo
Switch to hubYesNo
Switch to computer or serverNoYes
Switch to routerNoYes
Switch to IP phoneNoYes
1. 100BASE-TX and 1000BASE-T traffic requires twisted four-pair, Category 5, Category 5e, or
Category 6 cable. 10BASE-T traffic can use Category 3 or Category 4 cable.
Where to Go Next
If the default configuration is satisfactory, the switch module does not need further configuration. You
can use any of these management options to change the default configuration:
• Using the Device Manager
Access the device manager through a web browser from anywhere in your network. See “Using the
Device Manager” section on page 2-16 for instructions.
• Using the Command-Line Interface
The switch module CLI is based on Cisco IOS software and enhanced to support desktop-switching
features. You can fully configure and monitor the switch module from the CLI. You can access the
CLI either by connecting your management station directly to the switch module console port or by
using Telnet from a remote management station. Refer to the switch module command reference on
Cisco.com for more information.
1
Straight-Through Cable
1
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
OL-13269-01
2-27
Page 28
Where to Go Next
Chapter 2 Switch Installation
• Using SNMP
You can use SNMP management applications such as CiscoWorks Small Network Management
Solution (SNMS) to configure and manage the switch module. You also can manage it from an
SNMP-compatible workstation that is running platforms such as HP OpenView or SunNet Manager.
• Using the Dell CMC
See the Dell documentation for more information.
Cisco Catalyst Blade Switch 3130 for Dell and Cisco Catalyst Blade Switch 3032 for Dell Hardware Installation Guide
2-28
OL-13269-01
Page 29
Chapter 2 Switch Installation
Where to Go Next