Cisco Systems CATALYST6500, WS-X6624-FXS User Manual

Contents

Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
Product Numbers: WS-X6624-FXS
This publicationdescribes how to install the Catalyst 6500 series 24-port Foreign Exchange Station (FXS) analog interface module. The FXS interfaces connect directly to standard analog telephones or
This publication consists of the following sections:
Safety Overview, page 2
Features, page 5
Front Panel Description, page 9
Specifications, page 10
Installing the 24-Port FXS Analog Interface Module, page 11
Connecting a Cable to the 24-Port FXS Analog Interface Modu le Port, page 15
What to Do After Installing the 24-Port FXS Analog Interface Module, page 16
Regulatory Standards Compliance, page 17
Obtaining Documentation, page 17
Obtaining Technical Assistance, page 19
The FXS interfaces supply ring voltage, dial tone, and other services as described in this publication. FXS ports emulate the central office (CO) or private branch exchange (PBX) in that they provide a
service to an analog telephone or fax machine. The telephone or fax machine behaves as if it is connected to a normal CO or PBX line.
Note All signaling configuration is done through Cisco CallManager. Refer to the Cisco CallManager
documentation for complete configuration details.
Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2000–2003 Cisco Systems, Inc. All rights reserved.

Safety Overview

Safety Overview
Safety warnings appear throughout this publication in procedures that may harm you if performed incorrectly. A warning symbol precedes each warning statement.
Note For a complete description of safety and compliance requirements, refer to the Regulatory Compliance
and Safety Information for the Calyst 6500 Series Switches document.
Warning
Waarschuwing
IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that a ppear in this publication, refer to the translated safety warnings that accompanied this device.
Note: SAVE THESE INSTRUCTIONS Note: This documentation is to be used in conjunction with the specific product installation guide
that shipped with the product. Please refer to the Installation Guide, Configuration Guide, or other enclosed additional documentation for further details.
BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Voor een vertaling van de waarschuwingen die in deze publicatie verschijnen, dient u de vertaalde veiligheidswaarschuwingen te raadplegen die bij dit apparaat worden geleverd.
Opmerking BEWAAR DEZE INSTRUCTIES. Opmerking Deze documentatie dient gebruikt te worden in combinatie met de
installatiehandleiding voor het specifieke product die bij het product wordt geleverd . Raadpleeg de installatiehandleiding, configuratiehandleiding of andere verdere ingesloten documentatie voor meer informatie.
Varoitus
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
2
TÄRKEITÄ TURVALLISUUTEEN LIITTYVIÄ OHJEITA Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan. Ennen
kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä asiakirjassa esitettyjen varoitusten käännökset löydät laitteen mukana toimitetuista ohjeista.
Huomautus SÄILYTÄ NÄMÄ OHJEET Huomautus Tämä asiakirja on tarkoitettu käytettäväksi yhdessä tuotteen mukana tulleen
asennusoppaan kanssa. Katso lisätietoja asennusoppaasta, kokoonpano-oppaasta ja muista mukana toimitetuista asiakirjoista.
78-10975-02
Safety Overview
Attention
Warnung
IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. V ous vous trouvez dans une situation pouvant c auser
des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions d'avertissements figurant dans cette publication, consultez les consignes de sécurité traduites qui accompagnent cet appareil.
Remarque CONSERVEZ CES INFORMATIONS Remarque Cette documentation doit être utilisée avec le guide spécifique d'installation du produit
qui accompagne ce dernier. Veuillez vous reporter au Guide d'installation, au Guide de configuration, ou à toute autre documentation jointe pour de plus amples renseignements.
WICHTIGE SICHERHEITSANWEISUNGEN Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer
Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewusst. Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise sind im Lieferumfang des Geräts enthalten.
Hinweis BEWAHREN SIE DIESE SICHERHEITSANWEISUNGEN AUF Hinweis Dieses Handbuch ist zum Gebrauch in Verbindung mit dem Installationshandbuch für Ihr
Gerät bestimmt, das dem Gerät beiliegt. Entnehmen Sie bitte alle weiteren Informationen dem Handbuch (Installations- oder Konfigurationshandbuch o. Ä.) für Ihr spezifisches Gerät.
Figyelem!
Avvertenza
FONTOS BIZTONSÁGI ELÕÍRÁSOK Ez a figyelmezetõ jel veszélyre utal. Sérülésveszélyt rejtõ helyzetben van. Mielõtt bármely
berendezésen munkát végezte, legyen figyelemmel az elektromos áramkörök okozta kockázatokra, és ismerkedjen meg a szokásos balesetvédelmi eljárásokkal. A kiadványban szereplõ figyelmeztetések fordítása a készülékhez mellékelt biztonsági figyelmeztetések között található.
Megjegyzés ÕRIZZE MEG EZEKET AZ UTASÍTÁSOKAT! Megjegyzés Ezt a dokumentációt a készülékhez mellékelt üzembe helyezési útmutatóval együtt kell
használni. További tudnivalók a mellékelt Üzembe helyezési útmutatóban (Installation Guide), Konfigurációs útmutatóban (Configuration Guide) vagy más dokumentumban találhatók.
IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Per le traduzioni delle avvertenze riportate in questo documento, vedere le avvertenze di sicurezza che accompagnano questo dispositivo.
Nota CONSERVARE QUESTE ISTRUZIONI Nota La presente documentazione va usata congiuntamente alla guida di installazione specifica
spedita con il prodotto. Per maggiori informazioni, consultare la Guida all'installazione, la Guida alla configurazione o altra documentazione acclusa.
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
3
Safety Overview
Advarsel
Aviso
VIKTIGE SIKKERHETSINSTRUKSJONER Dette varselssymbolet betyr fare. Du befinner deg i en situasjon som kan forårsake personskade.
Før du utfører arbeid med utstyret, bør du være oppmerksom på farene som er forbundet med elektriske kretssystemer, og du bør være kjent med vanlig praksis for å unngå ulykker. For å se oversettelser av advarslene i denne publikasjonen, se de oversatte sikkerhetsvarslene som følger med denne enheten.
Merk TA VARE PÅ DISSE INSTRUKSJONENE Merk Denne dokumentasjonen skal brukes i forbindelse med den spesifikke
installasjonsveiledningen som fulgte med produktet. Vennligst se installasjonsveiledningen, konfigureringsveiledningen eller annen vedlagt tilleggsdokumentasjon for detaljer.
INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. O utilizador encontra-se numa situação que poderá ser
causadora de lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha em atenção os perigos envolvidos no manuseamento de circuitos eléctricos e familiarize-se com as práticas habituais de prevenção de acidentes. Para ver traduções dos avisos incluídos nesta publicação, consulte os avisos de segurança traduzidos que acompanham este dispositivo.
Nota GUARDE ESTAS INSTRUÇÕES Nota Esta documentação destina-se a ser utilizada em conjunto com o manual de instalação
incluído com o produto específico. Consulte o manual de instalação, o manual de configuração ou outra documentação adicional inclusa, para obter mais informações.
¡Advertencia!
Varning!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Vea las traducciones de las advertencias que acompañan a este dispositivo.
Nota GUARDE ESTAS INSTRUCCIONES Nota Esta documentación está pensada para ser utilizada con la guía de instalación del producto
que lo acompaña. Si necesita más detalles, consulte la Guía de instalación, la Guía de configuración o cualquier documentación adicional adjunta.
VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Se översättningarna av de varningsmeddelanden som finns i denna publikation, och se de översatta säkerhetsvarn ingarna som medföljer denna anordning.
OBS! SPARA DESSA ANVISNINGAR OBS! Denna dokumentation ska användas i samband med den specifika
produktinstallationshandbok som medföljde produkten. Se installationshandboken, konfigurationshandboken eller annan bifogad ytterligare dokumentation för närmare detaljer.
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
4
78-10975-02

Features

Features
78-10975-02
Features unique to the 24-port FXS analog interface module features are listed in Table 1. Features that the 24-port FXS analog interface module shares with other Catalyst 6500 modules are described in the following sections:
Hot Swapping, page 8
Power Management, page 8
Environmental Monitoring, page 9
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
5
Features
Table 1 24-Port Analog Interface Module Features
Digital Signal Processing per Port
G.711, G.729, G.729A voice encoding Silence suppression and voice activity detection Comfort noise generation Ringer, software programmable frequency and cadence, based on country Dual tone multifrequency (DTMF) detection Signaling, loop start Modem detection Line echo cancellation (32 ms) Impedance (600 ohms) Programmable analog gain, signaling timers SPAN or port mirroring support
FXS Interface Features
Address signaling formats: In-band DTMF Signaling formats: Loop start Ringing tone: Programmable Ringing voltage: Programmable, based on country Ringing frequency: Programmable, based on country Distance: 500 ohms maximum loop
Fax and modem transport parameters are listed in Table 2.
Table 2 Fax and Modem Transport Parameters
Parameter Name Description Default
Fax relay enable Enables/disables fax relay support in the gateway.
Checkbox checked Enabling this parameter will result in the gateway attempting fax relay negotiation as part of the call setup. If it is enabled but the far end does not support fax relay, the fax call will switch to pass-through mode.
Fax error correction mode (ECM) override
ECM is a feature present in some higher-end fax models that enables fax pages to be transmitted
Checkbox checked
error free. If ECM is enabled, the transmission has a low tolerance to jitter and packet loss. This results in a higher number of failed fax calls. For better reliability (even with higher packet loss), ECM needs to be disabled. ECM is disabled by enabling the checkbox.
Maximum fax rate Defines the maximum fax transmission rate to be
14400 used during the fax call. This can be used to restrict the bandwidth utilized for fax transmission.
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
6
78-10975-02
Table 2 Fax and Modem Transport Parameters (continued)
Features
Fax payload size Configures the size of the fax payload (fax data)
carried over real-time transport protocol (R TP). The value can range between 20 and 48.
Non standard facilities country code
Overrides the country code passed by the fax machine with the value defi ned. Setting the value to default (65535) results in the gateway passing the country code values received from the fax machine to the far end. If the value is not the default, then the gateway will pass the configured value as the country code to the far end. It will suppress the actual country code passed by the fax machine. Country code can be received by the gateway from the far end through ISDN. For details about the nonstandard facilities country code, refer to the T.35 specification.
Non standard facilities vendor code
Overrides the vendor/provider code passed by the fax machine with the value defined. Setting the value to default (65535) results in the gateway passing the vendor code values received from the fax machine to the far end. If the value is not the default, the gateway passes the configured value as the vendor code to the far end. It will suppress the actual vendor code passed by the fax machine. The vendor code can be received by the gateway from the far end through ISDN. For details about the nonstandard facilities vendor code, refer to the T.35 specification.
Fax/Modem Packet Redundancy
Enables packet redundancy support for fax and modem calls. Packet redundancy support results in retransmission of packets in case of problems. Enabling redundancy can ha ve a negati ve impact on performance.
V.21 Flag Sequence Detection Count
Specifies the number of V.21 flag sequences that need to be detected in order to det ermine that a n incoming fax tone is valid. Increase this value when there are line disturbances that require the gateway to wait for a longer period of time to confirm a fax call.
Port Used for Voice Calls
Optimizes the performance of voice calls. If this parameter is enabled and the parameters for modem and fax calls are disabled, the port is configured to accept only voice calls. Enable this parameter only if you are certain that a port will handle voice calls only.
20
65535
65535
Checkbox unchecked
4
Checkbox checked
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
7
Features
Table 2 Fa x an d Mo dem Transport Parameters (continued)
Port Used for Modem Calls
Enabled Port Used for Fax Calls
Named service event (NSE) type
Optimizes the performance of modem calls. If this parameter is enabled and the parameters for voice and fax calls are disabled, the port is configured to accept only modem calls. Enabling this parameter improves the performance of the port b y reducing or removing the switchover time required to move from voice mode to modem mode. Enable this parameter only if you are certain that a port will handle modem calls only
Optimizes the performance of fax calls. If this parameter is enabled and the parameters for voice and modem calls are disabled, the port is configured to accept only fax calls. Enabling this parameter improves the performance of the port b y reducing or removing the switchover time required to move from voice mode to fax mode. Enable this parameter only if you are certain that a port will handlefax calls only
NSE type attempts to standardize the transfer of tones over real-time transport protocol (RTP). Two NSE standards exist in Cisco products: one for Cisco IOS gateways and one for non-Cisco IOS gateways. The Catalyst 6500 Series Switch 8-port T1/E1 PSTN interface module supports both standards. Y ou need to configure the right NSE type based on the network setup. If the module needs to talk to a Cisco IOS gateway (a VG200 or AS5300 for example), set this option to IOS Gateway. If the gateways need to talk to other non-Cisco IOS gateways (such as a WS-X6608-E1/T1, VG248, or another WS-X6624-FXS), set this option to non-IOS Gateway.
Checkbox checked
Checkbox checked
Non-IOS Gateway

Hot Swapping

Hot swapping lets you remove and replace the 24- port FXS analog interf ace module while the system is operating. When the system detects that a module has been installed or removed, it automatically runs diagnostic and discovery routines, acknowledges the presence or absence of the module, and resumes system operation without any user intervention.

Power Management

Because the Catalyst 6500 series modules have different power requirements, certain switch configurations require more power than a single power supply can provide. Although the powe r management feature allows you to power all installed modules with two power supplies, redundancy is not supported in this configuration.
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
8
78-10975-02
For detailed information on power management, refer to the Catalys t 6500 Se ries Sw itch Software
33431
Configuration Guide.

Environmental Monitoring

Environmental monitoring of chassis components provides early warning indications of po ssible component failure to ensure saf e and re liable system operation and avoid network interruptions.
For detailed information on en vironmental monitoring, refer to the Catalyst 6500 Series Switch Softwar e Configuration Guide.

Front Panel Description

The 24-port FXS analog interface module front panel features are shown in Figure 1 and are de scribed in the following sections.
Figure 1 24-Port FXS Analog Interface Module
Front Panel Description

Status LED

Note For detailed information on the supervisor engine LEDs, refer to the Catalyst 6500 Series Switc h Module
WS-X6624-FXS
147
22
101316
STATUS
24 PORT FXS ANALOG STATION
2581114
36912151821
172023
19
24
24-1
When the 24-port FXS analog interface module is powered up, it initializes various hardware components and communicates with the supervisor engine. The Status LED on the module is described in Table 3.
Installation Guide.
Table 3 24-Port FXS Analog Interface Module Status LED
Color Description
Off The module is waiting for the supervisor engine to grant
power The module is not receiving power. Module was powered
down due to lack of po wer (module listed as power-deny in the show module status field)
Red The line card processor powered up, but is not running
The line card processor detected a fatal error during its diagnostics
Overtemperature condition (major threshold exceeded)
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
9

Specifications

Link LEDs

Table 3 24-Port FXS Analog Interface Module Status LED
Color Description
Orange The module is initializing hardware or communicating
with the supervisor engine The supervisor engine has disabled the module The supervisor engine has sent a
SCP_SET_DIAG_FEATURES message indicating that the diagnostics have failed
Overtemperature condition (minor threshold exceeded)
Green The module is operational; the supervisor engine has
granted a module online status
The Link LEDs show port and link status for each of the 24 ports as described in Table 4.
Table 4 24-Port FXS Analog Interface Module Link LEDs
LED Color Description
Link Green Telephone or fax machine is
1. CLI = command-line interface.

RJ-21 Connector

The RJ-21 connector on the module front panel allows you to attach 24 analog phones or fax machines to the system.
Specifications
The 24-port FXS analog interface module physical specifications are listed in Table 5.
Table 5 24-Port FXS Analog Interface Module Specifications
off-hook
Yellow Module or port disabled through
Off Port not active (connected device
1
CLI
on-hook) or link is not connected
10
Specifications Description
Environmental conditions
Operating temperature 32 to 104°F (0 to 40°C) Nonoperating temperature –40 to 167°F (–40 to 75°C) Humidity 10 to 90%, noncondensing
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02

Installing the 24-Port FXS Analog Interface Module

R
Power supply 2
Table 5 24-Port FXS Analog Interface Module Specifications (continued)
Specifications Description
Dimensions (H x W x D)
1.2 x 14.4 x 16 in. (30 x 356 x 406 mm) Weight Approximately 3 lb (1.36 kg) Software requirements Catalyst 6500 Series Switch supervisor engine software
version 5.5 or later Cisco CallManager software release 3.0 or later
Installing the 24-Port FXS Analog Interface Module
Slot 1 on the Catalyst 6500 Series Switch is reserv ed for the superv isor engi ne (see Figure 2). If you are using a redundant supervisor engine, it would go in slot 2; otherwise, slot 2 can be used for other modules. The 24-port FXS analog interface module can be installed in any of the othe r slots .
Figure 2 Catalyst 6006/6506 Switch Chassis
Supervisor engine
edundant supervisor
engine
Switching
modules
Fan
assembly
WS-X6K-SUP2-2GE
1
SUPERVISOR2
WS-X6K-SUP2-2GE
2
SUPERVISOR2
3
8 PORT GIGABIT ETHERNET
4
8 PORT GIGABIT ETHERNET
FAN
STATUS
5
6
STATUS
SYSTEM
CONSOLE
PWR MGMT
CONSOLE
RESET
PORT MODE
CONSOLE
STATUS
SYSTEM
CONSOLE
PWR MGMT
CONSOLE
RESET
PORT MODE
CONSOLE
WS-X6408
1
2
STATUS
LINK
WS-X6408
1
2
STATUS
LINK
WS-X6224
1
2
3
4
5
STATUS
24 PORT 100FX
LINK
LINK
LINK
WS-X6224
24 PORT 100FX
LINK
1
2
3
4
5
STATUS
LINK
LINK
LINK
LINK
o
Power supply 1
PCMCIA
PCMCIA
3
LINK
LINK
3
LINK
LINK
6
7
8
9
10
LINK
LINK
LINK
LINK
LINK
6
7
8
9
10
LINK
LINK
LINK
LINK
LINK
INPUT
FAN
OUTPUT
OK
OK
FAIL
Switch Load
100%
PORT 1
EJECT
1%
Switch Load
100%
EJECT
1%
4
5
LINK
LINK
4
5
LINK
LINK
11
12
13
14
15
LINK
LINK
16
LINK
LINK
LINK
LINK
LINK
11
LINK
12
13
14
15
16
LINK
LINK
LINK
LINK
LINK
LINK
PORT 2
LINK
LINK
PORT 1
PORT 2
LINK
LINK
6
7
LINK
6
LINK
17
18
LINK
LINK
17
18
LINK
LINK
8
LINK
LINK
7
8
LINK
LINK
19
20
21
22
23
24
LINK
LINK
LINK
LINK
LINK
19
LINK
20
21
22
23
24
LINK
LINK
LINK
LINK
LINK
LINK
o
INPUT
FAN
OUTPUT
OK
OK
FAIL
18224
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
The section is divided into the following topics:
Required Tools, page 12
Removing Modules, page 12
Installing Modules, page 13
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
11
Installing the 24-Port FXS Analog Interface Module
38859
screws

Required Tools

These tools are required to install the 24-port FXS analog module in th e Catalyst 6500 series switches:
Number 1 and number 2 Phillips screwdrivers for the captive installation screws
Antistatic mat or antistatic foam
Wrist strap or other grounding device

Removing Modules

Caution During this pro cedure, wear grounding wrist straps to a v oi d ESD damage to the mod ule. Do not d irectly
touch the backplane with your hand or any metal tool, or you could shock yourself.
Caution To prevent ESD damage, handle modules by the carrier edges only.
To remove a module from a Catalyst 6500 Series Switch, perform these steps:
Step 1 Disconnect any network interface cables attached to the ports on the module you intend to remove. Step 2 Loosen the captive installation screws, as shown in Figure 3.
Figure 3 Ejector Levers and Captive Installation Screws
WS-X6624-FXS
14710131619
STATUS
24 PORT FXS ANALOG STATION
25811141720
36912151821
22
23
24
24-1
Ejector lever
Captive installation
12
Step 3
Grasp the left and right ejector lev ers an d simultaneou sly pivot the levers outward to release th e module from the backplane connector. Figure 3 shows a close-up of the right ejector lever.
Step 4 Grasp the module front panel with one hand and place your other hand under the carrier to support and
guide it out of the slot. Do not touch the printed circuit boards or connector pins.
Step 5 Carefully pull the module straight out of the slot , keeping your other hand under the carrier to guide it. Step 6 Place the module on an antistatic mat or antistatic foam, or immediately install it in another slot.
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02
Installing the 24-Port FXS Analog Interface Module
Step 7 If the slot is to remain empty, install a module filler plate (part number 800-00292-01) to keep dust out
of the chassis, to maintain proper airflow through the module compartment, and to prevent exposure to hazardous voltages and current.
Warning
Caution Before connecting system power or turning on the switch, ensure that the system is connected to a
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.
supplementary ground. For comple te instructions on connecting the supplementary ground, refer to the Catalyst 6500 Series Switch Installation Guide publicatio n.

Installing Modules

Follow these steps to install th e 24-port FXS analog interface module:
Step 1 Connect an ASCII termin al or a PC running terminal emulation software to the console port on the
supervisor engine.
Step 2 Choose a slot for the new FXS analog interface module. Ensure that you have enough clearance to
accommodate any interface equipment that you will connect directly to the module ports. If possible, place modules between empty sl ots that contain only module filler plates.
Step 3 Remove the module from its antistatic packaging. Step 4 Guide the module into the slot, aligning the sides of the module with the guides in the slot (see Figure 4).
Avoid touchi ng the comp onents on the board.
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
13
Installing the 24-Port FXS Analog Interface Module
38860
Figure 4 Installing the FXS Module in the Chassis
WS-X6K-SUP1
1
2
3
4
5
SUPERVISOR I
WS-X6K-SUP1
SUPERVISOR I
WS-X6624-FXS
24 PORT FXS ANALOG STATION
WS-X6624-FXS
24 PORT FXS ANALOG S
WS-X6624-FXS
24 PORT FXS ANALOG STATION
STATUS
STATUS
1
4
7
10
13
16
19
2
STATUS
5
8
11
14
17
20
3
6
9
12
15
18
21
1
4
7
10
13
16
19
2
STATUS
5
8
11
14
17
20
3
6
9
12
15
18
21
TATION
1
4
7
10
13
16
19
2
STATUS
5
8
11
14
17
20
3
6
9
12
15
18
21
Switch Load
100%
DTE/
SYSTEM
ACTIVE
PWR MGMT
DCE
RESET
CONSOLE
1%
100%
DTE/
SYSTEM
ACTIVE
PWR MGMT
DCE
RESET
CONSOLE
1%
22
24-1
23
24
22
24-1
23
24
22
24-1
23
24
Switch Load
PCMCIA
PCMCIA
PORT 1
EJECT
EJECT
PORT 2
LINK
LINK
PORT 1
PORT 2
LINK
LINK
6
WS-X6624-FXS
1
4
7
10
13
16
19
22
2
STATUS
5
24-1
8
11
14
17
20
23
3
6
9
12
15
18
21
24
24 PORT FXS ANALOG STATION
Step 5
o
INPUT
FAN
OUTPUT
OK
OK
FAIL
While keeping the module oriented horizontally, carefully slide it into the slot until its front panel
o
INPUT
FAN
OUTPUT
OK
OK
FAIL
contacts the ejector levers (see Figure 3).
Step 6 Using the thumb and forefinger of each hand, simultaneously push the left lever and the right lever in to
seat the module all the wa y into the backplane connector.
Caution Alw ays use the ejector levers when installing or removing modules. A module that is partially seated in
the backplane causes the system to halt.
Step 7 Use a screwdriver to tight en the captive installation screws on the left and right sides of the module (see
Figure 3).
Step 8 Check the status of the module as follows:
a. After the module has booted and run diagnostics, ensure that the module Status LED is green
(module operational).
b. Enter the show module command at the Cat6000> prompt to verify that the system acknowledges
the new module and reports it as ok in the screen display.
14
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02

Connecting a Cable to the 24-Port FXS Analog Interface Mo dule Port

11485
11486
Connecting a Cable to the 24-Port FXS Analog Interface Module Port
Caution If the symbol of suitability with an overlaid cross (cross-hockey sticks symbol) appears above a port,
you must not connect the port to a public network that follows the European Union standards. Connecting the port to this type of public network can cause severe injury or damage your switch.
Use a standard RJ-21 Category 5 telco connector and cable to connect to the RJ-21 connector. Two types of RJ-21 connectors are shown in Figure 5 and Figure 6. A pinout for the module’s RJ-21 connector is provided in Table 6.
Figure 5 RJ-21 Telco Interface 90-Degree Cable Connector
Figure 6 RJ-21 Telco Interface 180-Degree Cable Connector
Table 6 RJ-21 Connector Pinout
Port Number
11
22
33
44
Connector Pin Number Signal
Ring
26
27
28
29
Tip
Ring Tip
Ring Tip
Ring Tip
Port Number
13 13
14 14
15 15
16 16
Connector Pin Number Signal
38
39
40
41
Ring Tip
Ring Tip
Ring Tip
Ring Tip
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
15

What to Do After Installing the 24-Port FXS Analog Interface Module

Table 6 RJ-21 Connector Pinout (continued)
Port Number
55
66
77
88
99
10 10
11 11
12 12
25, 50, 51, 52 GND
Connector Pin Number Signal
Ring
30
31
32
33
34
35
36
37
Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Port Number
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
Connector Pin Number Signal
42
43
44
45
46
47
48
49
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
Ring Tip
What to Do After Installing the 24-Port FXS Analog Interface Module
After you have installed the 24-port FXS analog interface module, refer to the Catalyst 6500 Series Switch Software Configuration Guide for complete configuration de tails. Note that all signaling
configuration is done through Cisco CallManager ; refer to the most recent version of Cisco CallManager documentation for configuration instructions.
16
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02

Regulatory Standards Compliance

Catalyst 6500 Series Switch modules, when in stalled in a system, comply with the standards listed in
Table 7.
Table 7 Catalyst 6500 Series Switch Regulatory Compliance Specifications
Agency Approvals Specification
Compliance CE Safety UL
8
EMC
1. CE = European Compliance.
2. UL = Underwriters Laboratory.
3. CSA = Canadian Standards Association.
4. EN = European Norm.
5. IEC = International Electrotechnical Commission.
6. TS = Technical Specification.
7. AS/NZS = Standards Australia/Standards New Zealand.
8. EMC = electromagnetic compatibility.
9. FCC = Federal Communications Commission.
10. CFR = Code of Federal Regulations.
11. ICES = Interference-Causing Equipment Standard.
12. UTP = unshielded twisted-pair.
13. VCCI = Voluntary Control Council for Information Technology Equipment.
14. FTP = foil twisted-pair.
1
Marking
2
1950, CSA3-C22.2 No. 950, EN4 60950, IEC5 950, TS6001, AS/NZS7
3260 FCC9 Part 15 (CFR10 47) Class A, ICES11-003 Class A, EN55022 Class A,
CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A with UTP cables
EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP
14
cables
Regulatory Standards Compliance
12
13

Obtaining Documentation

Cisco provides several ways to obtain documentation, technical assistance, and other technical resources. These sections explain how to obtain technical information from Cisco Systems.

Cisco.com

You can access the most current Cisco documentation on the World Wide Web at this URL:
http://www.cisco.com/univercd/home/home.htm
You can access the Cisco website at this URL:
http://www.cisco.com
International Cisco websites can be accessed from this URL:
http://www.cisco.com/public/countries_languages.shtml
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
17
Obtaining Documentation

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which may have shipped with your product. The Documentation CD-R OM is updated regul arly and may be more current than printed documentation. The CD -R OM package is av ailable as a single unit or through an annual or quarterly subscription.
Registered Cisco.com users can order a single Documentation CD-ROM (product number DOC-CONDOCCD=) through the Cisco Ordering tool:
http://www.cisco.com/en/US/partner/ordering/ordering_place_order_ordering_tool_launch.html
All users can order monthly or quarterly subscriptions through the online Subscription Store:
http://www.cisco.com/go/subscription

Ordering Documentation

You can find instructions for ordering documentation at this URL:
http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm
You can order Cisco documen tation in th ese ways:
Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from
the Networking Products MarketPlace:
http://www.cisco.com/en/US/partner/ordering/index.shtml
Nonregistered Cisco.com users can order documentation through a local account re presentative by
calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

You can submit comments electronically on Cisco.com. On the Cisco Documentation home page, click Feedback at the top of the page.
You can e-mail your comments to bug-doc@cisco.com. You can submit comments by using the response card (if present) behind the front cover of your
document or by writing to the following address: Cisco Systems
Attn: Customer Document Ordering 170 West Tasman Drive San Jose, CA 95134-9883
We appreciate your comments.
18
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02

Obtaining Technical Assistance

Cisco provides Cisco.com, which includes the Cisco Technical Assistance Center (TAC) website, as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample confi gurations from the Cisco TAC website. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC website, including TAC tools and utilities.

Cisco.com

Cisco.com offers a suite of interactive, networked services that let you access Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.
Cisco.com provides a broad range of features and services to help you with these tasks:
Streamline business processes and improve productivity
Resolve technical issues with online support
Download and test software packages
Order Cisco learning materials and merchandise
Obtaining Technical Assistance
Register for online skill assessment, training, and certification programs
To obtain customized information and service, you can self-register on Cisco.com at this URL:
http://tools.cisco.com/RPF/register/reg ister.do

Technical Assistance Center

The Cisco TAC is available to all customers who ne ed technical assistance with a Cisco product, technology, or solution. Two types of support are available: the Cisco TAC website and the Cisco TAC Escalation Center. The type of support that you choose depends on the priority of the problem and the conditions stated in service contracts, when applicable.
We categorize Cisco TAC inquiries according to urgency:
Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities,
product installation, or basic product configuration. There is little or no impact to your business operations.
Priority level 3 (P3)—Ope rational performance of the network is impaired, but most business
operations remain functional. You and Cisco are willing to commit resources during normal b usiness hours to restore service to satisfactory levels.
Priority level 2 (P2)—Operation of an existing network is severely degraded, or significant aspects
of your business operations are negatively impacted by inadequate performance of Cisc o produc ts. You and Cisco will commit full-time resources during normal business hou rs to resolve the situation.
Priority level 1 (P1)—An existing network is “down,” or there is a critical impact to your business
operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
19

Obtaining Additional Publications and Information

Cisco TAC Website

The Cisco TAC website provides online documen ts and tools to help troubleshoot and resolve technical issues with Cisco products and technologies. To access the Cisco TAC website, go to this URL:
http://www.cisco.com/tac
All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC website. Some services on the Cisco TAC website require a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register:
http://tools.cisco.com/RPF/register/reg ister.do
If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco TAC website, you can open a case online at this URL:
http://www.cisco.com/tac/caseopen
If you have Internet access, we recommend that you open P3 and P4 cases online so that you can fully describe the situation and attach any necessary files.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradati on signi f icantly impact s b usi ness operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.
To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL:
http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml
Before calling, please check with your network operations center to determine the Cisco support services to which your company is entitled: for e xample, SMARTnet, SMARTnet Onsite, or Network Sup ported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solu tio ns is available from various online and printed sources.
The Cisco Product Catalog describes the networking products offered b y Ci sco Systems, as well as
ordering and customer support services. Access the Cisco Product Catalog at this URL:
http://www.cisco.com/en/US/products/products_catalog_links_launch.html
Cisco Press publishes a wide range of networking publications. Cisco suggests these titles for new
and experienced users: Internetworking Terms and Acronyms Dictionary, Internetworking Technology Handbook, Internetworking Troubleshooting Guide, and the Internetworking Design Guide. For current Cisco Press titles and other information, go to Cisco Press online at this URL:
20
http://www.ciscopress.com
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02
Obtaining Additional Publications and Information
Packet magazine is the Cisco quarterly publication that provides the latest networking trends,
technology breakthroughs, and Cisco products and s olutions to help industry professionals get the most from their networking investment. Included are networking deployment and troubleshooting tips, configuration examples, customer case studies, tutorials and training, certif ication information, and links to numerous in-depth online resources. You can access Packet magazine at this URL:
http://www.cisco.com/go/packet
iQ Magazine is the Cisco bimonthly publication that delivers the latest information about Internet
business strategies for executives. You can access iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering
professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journ al at this UR L:
http://www.cisco.com/en/US/about/ac123/ac147/about_cisco_the_internet_protocol_journal.html
Training—Cisco offers world-class networking training. Current offerings in network training are
listed at this URL:
http://www.cisco.com/en/US/learning/le31/learning_recommended_training_list.html
78-10975-02
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
21
Obtaining Additional Publications and Information
22
This document is to be used in conjunction with the Catalyst 6500 Series Switch Module Installation Guide. CCIP, CCSP, the Cisco Arrow logo, the Cisco Powered Network mark, Cisco Unity, Fo llow Me Browsing, FormShare, and StackWise are trademarks
of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, the Cisco IOS logo, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Em powering the Int ernet Generation, Enterpris e/Solve r, EtherChan nel, EtherSwitch, Fast Step, GigaStack, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, MGX, MICA, the Networkers logo, Networking Academy, Network Registrar, Pa cket, PIX, Post-Routing, Pre-Routing, RateMUX, Registrar, ScriptShare, SlideCast, SMARTnet, StrataView Plus, Stratm, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries.
All other trademarks mentioned in this document or Web site are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0304R)
Copyright © 200-2003 Cisc o Sy stems , Inc. All r ights reserved.
Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note
78-10975-02
Loading...