Cisco Systems 400 User Manual

Quick Start Guide
FASTHUB 400 10/100 SERIES
CABLING AND START UP
IE S
1
TAKE OUT WHAT YOU NEED
2
CONNECT THE HUB TO OTHER NETWORK DEVICES
3
ASSIGN IP INFORMATION TO THE HUB
4
DISPLAY THE WEB-BASED HUB MANAGER
Take Out What You Need
FastHub 400 10/100 series hub
1 0 B
a s e
T / 1 0
0 B a
s e T
(12- or 24-port model)
FastHub 400 10/100 Series Installation and Configuration Guide
RJ-45-to-RJ-45 rollover console cable (FastHub 412M and FastHub 424M models only)
RJ-45-to-DB-9 console-to-PC adapter
1
(FastHub 412M and FastHub 424M models only)
x
R P S
1 x
2 x
3 x
4 x
5 x
1 0 1 00
6 x
7
x
8 x
9 x
1 0 x
1 1 x
1 2 x
1
M O
D E
2
Quick Start Guide
R P S
10 10
M O
D E
Installation
Configuration
Guide
1 0 B a s
e T / 1
0 0 B
a s e
T x
1 x
2 x
3 x
4 x
5 x
0
6 x
7 x
8 x
9 x
1 0 x
1 1 x
1 2 x
1 3 x
1 4 x
1 5 x
1 6 x
1 7 x
1 8 x
1 9 x
2 0 x
2 1 x
2 2 x
2 3 x
2 4 x
2 4
Black AC power cable
Rack-mount kit
Rubber feet
If any item is missing or damaged, contact your Cisco representative or reseller for support.
Note: You need to supply Category 3, 4, or 5 straight-through or crossover cables to connect to Ethernet devices.
Connect the Hub to Other Network Devices
R
P
S
1x
2x
3x
4x
1
0
1
0 0
M
O
D
E
5x
6x
7x
8x
9x
10BaseT/100BaseTX network port (RJ-45)
Maximum cable length:
328 ft (100 m)
10BaseT or
100BaseTX port
(RJ-45)
Ethernet cable
(not supplied)
Note: Use a straight-through cable to connect two ports when one of the ports is designated with an X. Use a crossover cable to connect two ports when both ports are designated with an X.
Connect the Hub to Servers, Routers, and Workstations
Connect a Category 3, 4, or 5 straight-through cable to any 10/100 port on the hub and to a 10BaseT port on the workstation, server, or router.
10BaseT/100BaseTx
10x
11x
12x
13x
14x
15x
16x
17x
18x
19x
20x
21x
22x
23x
24x
24
2
Connect the Hub to Switches and Other Hubs
Connect a Category 3, 4, or 5 crossover cable to any 10/100 port on the hub and to a 10BaseT port on the target switch or hub.
Connect a Category 5 crossover cable to any 10/100 port on the hub and to a 100BaseTX port on the target switch or hub.
Connect a Category 5 straight-through cable to any 10/100 port on the hub and to a 100BaseTX port on the workstation, server, or router.
Connect the Hub to Other Network Devices (continued)
D
C
IN
P
U
T
S F
O
R
R
E
M
O
T
E
P
O
W
E
R
S
U P
P
L
Y
UP
R
A
T
IN
G 1 0
0-12
7 / 2
0
0
-2 4 0
V
2
A
/1A
50
/ 6
0 H
R
A
T
IN
G 1 0
0
-12 7 / 2
00
-2 4 0
V
2
A
/1
A 5
0
/ 6
0 H
R
A
T
IN
G 1 0
0
-12 7 / 2
0
0
-2 4 0
V
2
A
/1
A 5
0
/ 6
0 H
CONSOLE
~
z
CONSOLE
~ z
CONSOLE
~ z
S
P E
C
I F
IE
D
IN
M
A
N
U
A
L
+
5
V
@
6
A
, +
1
2
V
@
1
A
DC INPUT
1
0 /1
0
0
B
A
S
E
­T
X
DOWN
S
T
A
T D
U
P
10
0
MEDIA MODULE
D
C
IN
P
U
T
S F
O
R
R
E
M
O
T
E
P
O
W
E
R
1
S
0
U
/ 1
P
0
P
0
L
B
Y
A
S
E
­T
UP
DOWN
UP
DOWN
X
S
P E
C
IF
IE
D
IN
M
A
N
U
A
L
+
5
V
@
6
A
, +
1
2
V
@
1
A
DC INPUT
ST
A
T
D U
P
10
0
MEDIA MODULE
D
C
IN
P
U
T
S
F
O
R
R
E
M
O
T
E
P
O
W
E
R
S
U
1
P
0
P
0
B
L
Y
A S
E
­F
X
S
P E
C
IF
IE
D
IN
M
A
N
U
A
L
+
5
V
@
6
A
, +
1
2
V
@
1
A
DC INPUT
LIN
K
DU
P
TX
R X
MEDIA MODULE
3
(Optional) Install the Switched Uplink Module in the Hub
Power off the hub.
1
Remove and set aside the screws
2
attaching the faceplate to expansion slot on the hub. The screws will be used later in Step 6.
Remove the faceplate from the hub and
3
store it for future use.
Slide the module into the slot
4
card-guides until you feel it touch the back of the hub.
Push the module firmly until it snaps
5
into place and is firmly seated.
Insert and tighten the screws on the
6
module faceplate.
Power on the hub.
7
(Optional) Connect to the Switched Uplink Module Port
Insert a connector according to the type of module (10/100 or 100BaseFX), as follows:
10BaseT/100BaseTX connector—Insert
the connector until it snaps into place in the module port.
Note: Use a straight-through cable to connect two ports when one of the ports is designated with an X. Use a crossover cable to connect two ports when both ports are designated with an X.
100BaseFX SC connector—Remove the rubber plugs from the fiber-optic port on the module and store them for future use. Insert the connector in the fiber-optic module port.
Connect the Hub to Other Network Devices (continued)
D C
I
N
P
U
T S
F
O
R R
E
M
O
T
E
P
O
W
E
R
1
S
0
U
/1
P
0
P
0
B
L Y
A
S
E
-T X
S
P
E
C
IF
IE
D
IN
M
A
N U
A
L + 5
V
@
6 A
,
+ 1
2
V
@
1
A
DC INPUT
STATDUP 100
MEDIA MODULE
Power outlet
100-127 / 200-240 V~
2A /1A 50 / 60 Hz
RJ-45-to-RJ-45
rollover console cable
(supplied)
RATING
CONSOLE
UP
DOWN
Console port
(RJ-45)
RJ-45-to-DB-9
adapter (supplied)
4
(Optional) Connect the Console Cable
Make sure console port settings of the
1
FastHub 400M model match the settings of the terminal, PC, or laptop. The default settings of the hub console port are 9600 baud, 8 data bits, 1 stop bit, no parity, and no flow control.
Connect the rollover console cable to
2
the CONSOLE port on the hub.
Connect the other end of the rollover
3
cable to your terminal, PC, or laptop (if necessary, use an appropriate adapter, such as the supplied RJ-45-to-DB-9 adapter).
From your terminal, PC, or laptop, start
4
the terminal emulation program.
Power Up the Hub
Connect one end of the power cord to
1
the hub and the other end to a power source.
Note: You can use the internal power supply and the Cisco 600W AC Redundant Power System (RPS). Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS receptacle.
Wait approximately 2 minutes for the
2
hub to complete its power-on self-test (POST).
After POST completes, the Continue with configuration dialog? prompt appears on the management station. You can then follow the prompts to assign IP information to the hub.
(Optional) Assign IP Information to the Hub
The hub is designed to operate with little or no user intervention. In most cases, you can use it with its default settings.
Assign IP information to the FastHub 400M model so that you can use the FastHub 400 series Hub Manager web-based interface and so that the hub can communicate with local routers and the intranet.
Contact your system administrator for the hub IP information, and record it here.
Hub IP address:
Enter the IP address of the default
4
gateway (for example: 10.1.105.254):
Enter IP default gateway: 10.1.105.254
The following information is displayed:
The following configuration command script was created: ip address 10.1.105.20 255.255.255.0 ip default-gateway 10.1.105.254 ! end
Enter Y:
5
Use this configuration? Y
Subnet mask:
The following information is displayed:
Default gateway:
Building configuration...
From the terminal or PC, enter Y:
5
1
Continue with configuration dialog? Y
Enter the IP address (for example:
2
10.1.105.20):
Enter IP address: 10.1.105.20
Enter the subnet mask (IP netmask)
3
(for example: 255.255.255.0):
Enter IP netmask: 255.255.255.0
Use the enabled mode ‘configuration’ command to modify this configuration.
Press RETURN to get started.
Press Return.
6
Exit from the terminal session.
7
You can now display the FastHub 400 series Hub Manager.
(Optional) Display the FastHub 400 Series Hub Manager
If you have the IP address to the hub, you can display the FastHub 400 series Hub Manager from your intranet. You can use the FastHub 400 series Hub Manager to configure and monitor the hub.
Start Netscape Communicator (4.03 or higher) or Microsoft Internet Explorer
1
(4.01 or higher). Make sure that Java and JavaScript are enabled.
Enter the IP address of the hub in the URL field if you are using Communicator
2
(the Address field if you are using Internet Explorer).
The FastHub 400 series Hub Manager Home page appears.
Click Apply after making changes on a page.
Click Revert to discard unapplied changes on a page.
Click Help for procedures and detailed field descriptions.
Click the Mode button to change the mode that the LEDs display for the fixed 10/100 ports.
HOME PORT GROUP IP SNMP CDP SYSTEM
Click to display the settings, status, and statistics of an installed 10BaseT/100BaseTX or 100BaseFX switched uplink module.
Click these topics to move from page to page. On Netscape Communicator only, when the cursor is above a topic, a pop-up briefly describes the options on that particular page.
Click a port to display its settings, status, and statistics.
Shows when another hub is connected to a stacking connector on the hub rear panel.
Note: The FastHub 400 10/100 Series Installation and Configuration Guide and the FastHub 400 10/100 series Hub Manager online help provide complete information about the web console and describe how to configure and monitor the hub.
6
Corporate Headquarters
Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
European Headquarters
Cisco Systems Europe s.a.r.l. Parc Evolic, Batiment L1/L2 16 Avenue du Quebec Villebon, BP 706 91961 Courtaboeuf Cedex France http://www-europe.cisco.com Tel: 33 1 6918 61 00 Fax: 33 1 6928 83 26
Americas Headquarters
Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-7660 Fax: 408 527-0883
Asia Headquarters
Nihon Cisco Systems K.K. Fuji Building, 9th Floor 3-2-3 Marunouchi Chiyoda-ku, Tokyo 100 Japan http://www.cisco.com Tel: 81 3 5219 6250 Fax: 81 3 5219 6001
Cisco Systems has more than 200 offices in the following countries. Addresses, phone numbers, and fax numbers are listed on the
Cisco Connection Online Web site at http://www.cisco.com.
Argentina Australia Austria Belgium Brazil Canada Chile China (PRC) Colombia Costa Rica Czech Republic Denmark
England
France Germany Greece Hungary India Indonesia Ireland Israel Italy Japan Korea Luxembourg Malaysia
The Netherlands New Zealand Norway Peru Philippines Poland Portugal Russia Saudi Arabia Scotland Singapore
Mexico
South Africa
AccessPath, Any to Any, AtmDirector, the CCIE logo, CD-PAC, Centri, the Cisco Capital logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, the Cisco Press logo, the Cisco Technologies logo, ClickStart, ControlStream, DAGAZ, Fast Step, FireRunner, IGX, IOS, JumpStart, Kernel Proxy, LoopRunner, MGX, Natural Network Viewer, NetRanger, NetRanger Director, NetRanger Sensor, NetSonar, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RouteStream, Secure Script, SMARTnet, SpeedRunner, Stratm, StreamView, The Cell, TrafficDirector, TransPath, ViewRunner, VirtualStream, VlanDirector, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, Enterprise/Solver, EtherChannel, FastHub, ForeSight, FragmentFree, IP/TV, IPX, LightStream, LightSwitch, MICA, Phase/IP, StrataSphere, StrataView Plus, and SwitchProbe are registered trademarks of Cisco Systems, Inc. in t he U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. (9811R)
Spain Sweden Switzerland Taiwan, ROC Thailand Tur key United Arab Emirates United States Venezuela
78-5566-01
Loading...