Cisco Catalyst Switch Module 3110G,
3110X, and 3012 for IBM BladeCenter
Hardware
April 2008
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Installation Guide
Text Part Number: OL-12192-01
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following inform ation is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency energy. If it is not
installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to
comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are designed to provide reasonable
protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital
devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television
communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its
peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
• Turn the television or radio antenna until the interference stops.
• Move the equipment to one side or the other of the television or radio.
• Move the equipment farther away from the television or radio.
• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits
controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at
www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1005R)
Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
Two Twisted-Pair Cable PinoutsB-5
Identifying a Crossover CableB-5
I
NDEX
iv
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
Audience
Purpose
Preface
This guide is for the networking or computer technician responsible for installing a Cisco Catalyst
switch module. We assume that you are familiar with the concepts and terminology of Ethernet and local
area networking.
This guide documents the hardware features of the Cisco Catalyst Switch Module 3110G, 3110X,
and 3012 for IBM BladeCenter—referred to as the switch module. It describes the physical and
performance characteristics of each switch module, explains how to install a switch module, and
provides troubleshooting information.
This guide does not describe system messages that you might receive or how to configure your switch
module. For more information, see the switch module getting started guide, the software configuration
guide, the command reference, and the system message guide on Cisco.com. For information about the
standard Cisco IOS Release
Cisco.com home page at Technical Support and Documentation > Documentation. On the Cisco
Documentation home page, select Release 12.1 or 12.2 from the Cisco IOS Software drop-down list.
Conventions
This document uses the following conventions and symbols for notes, cautions, and warnings.
Translations of the warning statements in this document appear in the Regulatory Compliance and Safety Information for the Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter that
ships with the switch.
NoteMeans reader take note. Notes contain helpful suggestions or references to materials not contained in
this manual.
12.1 or 12.2 commands, see the Cisco IOS documentation set from the
OL-12192-01
CautionMeans reader be careful. In this situation, you might do something that could result in equipment
damage or loss of data.
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
vii
Preface
Warning
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
Related Publications
For more information about the switch module, see these documents on Cisco.com:
•Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Software
Configuration Guide. This guide provides a product overview and detailed descriptions and
procedures for the switch module software features.
•Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Command Reference.
This reference provides detailed descriptions of the Cisco IOS commands specifically created or
modified for the switch module.
•Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter System Message
Guide. This guide provides descriptions of the system messages specifically created or modified for
the switch module.
•Cisco Software Activation Document for IBM BladeCenter. This document describes the supported
feature sets, software licenses, and information about using software activation in mixed software
switch stacks.
•Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Getting Started
Guide. This guide provides instructions on how to install and manage the switch module.
•Regulatory Compliance and Safety Information for the Cisco Catalyst Switch Module 3110G,
3110X, and 3012 for IBM BladeCenter. This guide contains agency approvals, compliance
information, and translated warning statements.
•Release Notes for the Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter.
The release notes include the system requirements, important notes, limitations, open and resolved
caveats, and documentation updates.
For more information about the IBM BladeCenter enclosure, see the IBM documentation at:
http://www-03.ibm.com/systems/bladecenter/
Obtaining Documentation, Obtaining Support, and Security
Guidelines
For information on obtaining documentation, obtaining support, providing documentation feedback,
security guidelines, and also recommended aliases and general Cisco documents, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical
documentation, at:
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
CHA PTER
1
Product Overview
The Cisco Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter—referred to as the
switch modules—are Ethernet switch modules that you install in an IBM BladeCenter
enclosure—referred to as the blade enclosure. You can connect devices to the switch modules for
connections to other network devices such as routers, servers, and other switches.
The Catalyst Switch Module 3110G and 3110X support stacking through Cisco StackWise Plus
technology. The Catalyst Switch Module 3012 does not support stacking. Unless otherwise noted, the
term switch module refers to a standalone switch module and to a switch stack.
NoteThis product is not intended to be connected directly or indirectly by any means whatsoever to interfaces
of public telecommunications networks.
This chapter provides a functional overview of the switch modules and covers these topics:
•Switch Modules, page 1-1
•Hardware Features, page 1-2
•Management Options, page 1-9
Switch Modules
Table 1-1 describes the switch modules.
Ta b l e 1-1Catalyst Switch Module 3110G, 3110X, and 3012
Switch Model Cisco Part NumberIBM Part NumberDescription
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
1-1
Hardware Features
201895
C
O
N
S
O
L
E
M
O
D
E
M
B
R
M
S
T
LNK
!
ACT
15
LNK
ACT
16
LNK
ACT
17
LNK
1 ST
A
CK 2
ACT
18
X
2
C
O
N
S
O
L
E
M
O
D
E
M
B
R
M
S
T
!
1 STACK 2
1
4
9
6
5
8
2
7
3
Table 1-1Catalyst Switch Module 3110G, 3110X, and 3012 (continued)
Switch Model Cisco Part NumberIBM Part NumberDescription
Catalyst Switch
Module 3110X
Catalyst Switch
Module 3012
Hardware Features
The Catalyst Switch Module 3110G and 3110X include the 10/100/1000 Ethernet ports or the 10-Gigabit
Ethernet module slot, console port, StackWise Plus ports, release latch, and the switch module LEDs
shown in
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
Chapter 1 Product Overview
270430
C
O
N
S
O
L
E
M
O
D
E
LNK
!
ACT
15
LNK
A
CT
16
LN
K
AC
T
17
LNK
ACT
18
1
2
5
6
3
4
The Catalyst Switch Module 3012 includes the 10/100/1000 Ethernet ports, console port, release latch,
and the switch module LEDs shown in
Figure 1-2Catalyst Switch Module 3012
Hardware Features
Figure 1-2 and described on the following pages.
1Catalyst Switch Module 30124Switch module LEDs
2Console port510/100/1000 Ethernet ports
3Mode button6Release latch
10/100/1000 Ethernet Ports
The Catalyst Switch Module 3110G and 3012 10/100/1000 Ethernet ports use standard RJ-45 connectors
with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 100BASE-TX and
1000BASE-T traffic requires Category
cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable.
For information about the 10/100/1000 Ethernet port connections and specifications, see the
“Connecting Devices to the Ethernet Ports” section on page 2-13 and Appendix B, “Connector and
Cable Specifications.”
5, Category 5e, or Category 6 unshielded twisted pair (UTP)
OL-12192-01
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
1-3
Hardware Features
10-Gigabit Ethernet Module Slot
The Catalyst Switch Module 3110X 10-Gigabit Ethernet module slot is used for an uplink connection to
other switches and routers. The module slot operates in full-duplex mode and uses the hot-swappable
Cisco X2 transceiver modules.
The X2 transceiver modules have a dual SC/PC connector (-SR, -LX4) or an Infiniband 4x connector
(-CX4) for connections to multimode fiber (MMF), single-mode fiber (SMF), or 4x
These are the supported Cisco X2 transceiver modules:
•X2-10GB-SR
•X2-10GB-CX4
•X2-10GB-LX4
For information about installing a transceiver module, see the “Installing Devices in the 10-Gigabit
Ethernet Slot” section on page 2-11. For cable specifications, see Appendix B, “Connector and Cable
Specifications.”
Port Numbering
Chapter 1 Product Overview
Infiniband cable.
Table 1-2 describes the switch module port numbering.
Ta b l e 1-2Switch Module Port Numbering
PortDescription
Ports 1 to 14
Ports 15 to 18 (Catalyst Switch
Module 3110G and 3012)
Port 1 (X2) (Catalyst Switch
Module 3110X)
1. The number of internal ports is determined by the blade enclosure model. See the blade enclosure documentation for more
information about internal port numbering.
1
Internal Gigabit Ethernet 1000BASE-X downlink ports that connect to
the blade enclosure.
The internal Ethernet management port (Fa0) is used only for switch module management traffic, not for
data traffic. It is connected to the IBM advanced Management Module (aMM) through the blade
enclosure backplane connector. Traffic to and from this port is isolated from the switch module ports.
This port only supports autonegotiation with 100 Mb/s and full-duplex mode.
1-4
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
Chapter 1 Product Overview
LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
201896
C
O
N
S
O
L
E
M
O
D
E
C
O
N
S
O
L
E
M
O
D
E
M
B
R
M
S
T
M
S
T
15
16
17
18
STACK
21
STACK
21
M
B
R
10
6
7
11
9 12
13
8
3 4
2 5
1
X2
Switch Module LEDs
You can use the switch module LEDs to monitor switch module activity. Figure 1-3 shows the switch
module LEDs and the Mode button that you use to activate the different modes.
Figure 1-3Switch Module LEDs and Mode Button
Hardware Features
OL-12192-01
8Stack member LED
10 Fault/stack mode LED
1Stack member LED
(Catalyst Switch Module 3110G)
2Mode button9Mode button
3Fault/stack mode LED
(Catalyst Switch Module 3110G)
Fault LED
(Catalyst Switch Module 3012)
4System power LED11 System power LED
5Stack master LED
12 Stack master LED
(Catalyst Switch Module 3110G)
6Port link LED13 X2 port status LEDs
7Port activity LED
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
1-5
Hardware Features
Mode Button
System Power LED
Chapter 1 Product Overview
The fault/stack or stack member LEDs are selected by using the Mode button. If the mode LED for a
particular mode is solid green, that mode is currently selected, and the other mode LEDs are off (only
Catalyst Switch Module 3110G and 3110X).
To select or change a mode, use a small pointed object to press the Mode button until the desired mode
is selected.
The system power LED shows whether the system is receiving power and is functioning properly.
Table 1-3 lists the LED colors and their meanings.
Ta b l e 1-3System LED
ColorSystem Status
OffSwitch module is not powered on.
GreenSwitch module is operating normally.
AmberSwitch module is receiving power but is not functioning properly.
Blinking greenSwitch module is running the power-on self-test (POST).
Stack Master LED
The stack master LED shows the stack master status. Tab le 1-4 lists the LED colors and their meanings
(only Catalyst Switch Module 3110G and 3110X).
Ta b l e 1-4Stack Master LED
ColorDescription
OffSwitch module is not the stack master.
GreenSwitch module is the stack master or a standalone switch.
AmberAn error occurred during stack master election, or another type of
stack error occurred.
1-6
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
Chapter 1 Product Overview
Fault/Stack Mode LED
The fault/stack mode LED shows either a fault condition or the switch stack status, depending on the
Mode button selection. When the switch module is not stacked and there is no fault, the LED is off. If
the switch module is stacked and the stack mode LED is selected, the stack member LED is active.
Table 1-5 lists the LED colors and their meanings (only Catalyst Switch Module 3110G and 3110X).
Ta b l e 1-5Fault/Stack Mode LED
ColorFault Mode DescriptionStack Mode Description
OffNo switch module faults. Stack mode is not selected.
Green—Switch stack mode is selected. When this LED is
AmberSwitch module fault
Hardware Features
green, the stack member LED displays the stack
membership number, and the port LEDs display link
status.
—
detected.
Fault LED
The fault LED shows the switch module fault condition. Tab le 1-6 lists the LED colors and their
meanings (only Catalyst Switch Module 3012).
Ta b l e 1-6Fault LED
Stack Member LED
The stack member LED is active when the switch module is stacked and you select by using the Mode
button. The stack member LED blinks the number of times equal to the switch stack membership
number.
3110X).
Ta b l e 1-7Fault/Stack Mode LED
ColorFault Mode Description
OffNo switch module faults.
AmberSwitch module fault detected.
Table 1-7 lists the LED colors and their meanings (only Catalyst Switch Module 3110G and
ColorDescription
OffStack mode is not selected, or the switch module is not stacked.
Blinking greenStack member number.
OL-12192-01
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
1-7
Hardware Features
Port LEDs
Chapter 1 Product Overview
The Catalyst Switch Module 3110G and 3012 port LEDs show interface activity and link status.
Table 1-8 lists the LED colors and their meanings.
Ta b l e 1-8Catalyst Switch Module 3110G and 3012 Port LEDs
ColorActivity LED DescriptionLink Status LED Description
OffNo activity.No link, or port was administratively
shut down.
Green—Link present, or the port might be
blocked by Spanning Tree Protocol
(STP) and is not forwarding data.
Blinking greenActivity. Port is sending or receiving
data.
When stack mode is selected on a Catalyst Switch Module 3110G, port 4 activity and link LEDs show
the status for StackWise Plus ports 1 and 2, respectively. The other port LEDs are off.
LED colors and their meanings.
—
Table 1-9 lists the
Ta b l e 1-9Catalyst Switch Module 3110G Port LEDs with Stack Mode Selected
ColorActivity LED DescriptionLink Status LED Description
OffNo link.No link.
GreenSwitch stack link is active.Switch stack link is active.
The Catalyst Switch Module 3110X port status LEDs show interface activity and link status. (The LEDs
combine to display status when an X2 transceiver is inserted.)
Table 1-10 lists the LED colors and their
meanings.
Ta b l e 1-10Catalyst Switch Module 3110X Port LEDs
ColorLED Description
OffNo link, or port was administratively shut down.
GreenLink present.
Blinking greenActivity. Port is sending or receiving data.
AmberPort is blocked by STP and is not forwarding data, or port was
administratively shut down.
Alternating
Link fault.
green-amber
1-8
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
OL-12192-01
Chapter 1 Product Overview
When stack mode is selected on a Catalyst Switch Module 3110X, the two port status LEDs show the
status for StackWise Plus ports 1 and 2, respectively.
Ta b l e 1-11Catalyst Switch Module 3110X Port Status LEDs with Stack Mode Selected
ColorPort Status LED Description
OffNo link.
GreenSwitch stack link is active.
StackWise Plus Ports
The switch module ships with a 1-meter StackWise Plus cable that you can use to connect the StackWise
Plus ports (only Catalyst Switch Module 3110G and 3110X).
CautionUse only approved cables and connect only to Catalyst Switch Module 3110G and 3110X. Equipment
might be damaged if connected to nonapproved Cisco cables or equipment.
Management Options
Table 1-11 lists the LED colors and their meanings.
You can order these StackWise Plus cables from your supplier:
•CAB-STK-E-0.5M= (0.5-meter cable)
•CAB-STK-E-1M= (1-meter cable)
•CAB-STK-E-3M= (3-meter cable)
Console Port
You can connect the switch module to a host such as a PC, workstation, or a terminal server through the
console port (shown in
to a host.
For more information about the console port, see the switch module getting started guide, the software
configuration guide, and the command reference on Cisco.com.
Management Options
The switch module offers several management options:
•Cisco IOS CLI
The switch module command-line interface (CLI) is based on Cisco IOS software and is enhanced
to support desktop-switching features. You can fully configure and monitor the switch module and
switch stack members from the CLI. You can access the CLI by connecting your management station
directly to the switch module console port or by using Telnet from a remote management station.
See the switch module getting started guide, the software configuration guide, and the command
reference on Cisco.com for more information.
Figure 1-1). Use the supplied USB-to-DB-9 cable to connect the switch module
OL-12192-01
•BladeCenter Advanced Management Module
For standalone switch modules, you can use the aMM to configure the switch module. See the IBM
BladeCenter Advanced Management Module User’s Guide for more information. For stacked
switches, use the CLI to configure and manage the switch stack.
Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide
1-9
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.