CHAUVET DJ SlimPAR Q12 ILS User Manual

User Manual
Table of Contents
SlimPAR Q12 ILS
1. Before You Begin .......................................................................
What Is Included ........................................................................................... 1
Unpacking Instructions.................................................................................. 1
Text Conventions .......................................................................................... 1
Symbols ........................................................................................................ 1
Disclaimer ..................................................................................................... 1
Intellectual Property ...................................................................................... 1
Safety Notes.................................................................................................. 2
2. Introduction ................................................................................ 3
Product Overview.......................................................................................... 3
Product Dimensions ...................................................................................... 3
3. Setup ........................................................................................... 4
AC Power...................................................................................................... 4
Power Linking................................................................................................................. 4
Mounting ....................................................................................................... 5
Orientation...................................................................................................................... 5
4. Operation .................................................................................... 6
Control Panel Operation................................................................................ 6
Menu Map ..................................................................................................... 6
Configuration (DMX) ..................................................................................... 7
DMX Personality and Starting Address.......................................................................... 7
D-Fi USB Connectivity .................................................................................. 7
D-Fi USB Compatibility .................................................................................................. 7
Configuration (D-Fi USB) ............................................................................................... 7
DMX Values .................................................................................................. 8
Configuration (Standalone) ........................................................................... 9
Preset Color Mode ......................................................................................................... 9
Automatic Programs....................................................................................................... 9
Auto-Program Speed ..................................................................................................... 9
Sound-Active Programs ................................................................................................. 9
Sound Sensitivity............................................................................................................ 9
Custom Color Mixing...................................................................................................... 9
Dimmer Curve ................................................................................................................ 9
IRC-6 Infrared Remote Control ..................................................................... 10
IRC-6 Operation ............................................................................................................. 10
Master/Slave Mode ....................................................................................... 11
Master/Slave Mode (D-Fi USB)..................................................................... 11
ILS Mode....................................................................................................... 11
5. Maintenance................................................................................ 12
Product Maintenance .................................................................................... 12
6. Technical Specifications ........................................................... 13
Warranty & Returns........................................................................ 14
Limited Warranty........................................................................................... 14
Returns.......................................................................................................... 14
Contact Us ...................................................................................... 15
1
SlimPAR Q12 ILS User Manual Rev. 1
Before You Begin
!

1. Before You Begin

What Is Included

SlimPAR Q12 ILS
Power cable

Unpacking Instructions

Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.

Claims

If the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.

Text Conventions

Convention Meaning
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
<ENTER> A key to be pressed on the product’s control panel
ON A value to be entered or selected
Quick Reference Guide

Symbols

Symbol Meaning
Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.
Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.

Disclaimer

Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com
.

Intellectual Property

The works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet.
© Copyright 2023 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, and SlimPAR Q12 ILS are registered trademarks or trademarks of Chauvet
& Sons LLC. (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
SlimPAR Q12 ILS User Manual Rev. 1
Page 1 of 15

Safety Notes

!
ALWAYS:
Connect to a grounded circuit. Connect to operating voltages as specified on the product's spec sticker. Disconnect from power before replacing the fuse. Disconnect from its power source during periods of inactivity. Use a safety cable when suspending overhead. Heed all restrictions and warnings on the spec sticker. Mount in a location with at least 20 in (50 cm) of ventilation. Replace the fuse with the same type and rating.
In the event of a serious operating problem, stop using immediately.
DO NOT:
Open this product or attempt any repairs. It contains no user-serviceable parts. Look at the light source when the product is on. Use if the power cord is crimped or damaged. Disconnect by pulling on the power cord. Allow flammable materials close to the product when it is operating. Touch the housing when it is on. Block any ventilation holes/slots in the housing. Connect to a dimmer or rheostat. Carry the product by its power cord. Operate in temperatures higher than 104°F (40°C). Expose to environments that exceed the Ingress Protection (IP) rating. Expose to rain or moisture. Use outdoors. Submerge. Expose to corrosive environmental conditions such as temperature, humidity, salinity,
pressure, radiation, or shock.
Set this product on a flammable surface.
Before You Begin
Keep this User Manual for future use. If the product is sold to someone else, be sure that they also receive this document.
Page 2 of 15
SlimPAR Q12 ILS User Manual Rev. 1
Introduction
MIC
MENU
UP DOWN ENTER
POWER IN:
100-240VAC,50/60Hz
DMX OUT DMX IN
For D-FI USB only
SAFETY LOOP
POWER OUT
Menu buttons
Power in/ out
Display
screen
Safety loop
Mounting bracket
Bracket adjustment
knob (2x)
3-pin DMX in/ out
D-Fi USB Port
9.7 in
246 mm
8.8 in
224.5 mm
2.9 in
74.8 mm
3.3 in
84 mm

2. Introduction

Product Overview

Product Dimensions

SlimPAR Q12 ILS User Manual Rev. 1
Page 3 of 15
Setup
!
1st product
2
nd
product
3
rd
product
Additional SlimPAR Q12 ILS
products
!

3. Setup

AC Power

The SlimPAR Q12 ILS has an auto-ranging power supply, and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non­use completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement

1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Power-Linking
The product provides power linking via the Edison outlet located in the back of the product. Please see the diagram below for further explanation.
Power-Linking Diagram
It is possible to power link up to 10 SlimPAR Q12 ILS products on 120 VAC or up to 18 SlimPAR Q12 ILS products on 230 VAC.
The power-linking diagram corresponds to the North American version of the product ONLY! If using the product in other markets, consult with the local Chauvet distributor, as power-linking connectors and requirements may differ by country or region.
Page 4 of 15
SlimPAR Q12 ILS User Manual Rev. 1
Setup
Mounting bracket
Safety cable
(such as CH-05 from Chauvet)
Mounting clamp
(such as CLP-15 or CLP-15N from Chauvet)
Bracket
adjustment knob

Mounting

Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.

Orientation

The SlimPAR Q12 ILS may be mounted in any position; however, make sure adequate ventilation is provided around the product.

Rigging

Before deciding on a location for the product, always make sure there is easy
for maintenance and programming purposes.
Make sure that the structure onto which the product is being mounted can support the product’s
weight. See the Technical Specifications for weight information.
When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, whether an elevated platform or a truss.
When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
When power-linking multiple products, mount the products close enough for power-linking cables to
reach.
The bracket adjustment knobs allow for directional adjustment when aiming the product to the
desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage the knobs.
Mounting Diagram
access to the product
SlimPAR Q12 ILS User Manual Rev. 1
Page 5 of 15
Operation

4. Operation

Control Panel Operation

To access the control panel functions, use the four buttons located next to the display. Please refer to the
Product Overview
Button Function
<MENU> Exits from the current menu or function
<UP> Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN>
<ENTER>

Menu Map

Refer to the SlimPAR Q12 ILS product page on www.chauvetdj.com for the latest menu map.
Main Level
4-Ch d 1–509 4-channel DMX mode 9-Ch d 1–504 9-channel DMX mode
iLS iLS1–4 Sets ILS mode
C--
(Static color)
P--
(Automatic
program)
S-- S
Snd
(Sound-active)
SEnS u 0–100 Sound sensitivity
u--
(Custom color)
diN
(Dimmer
speed)
SEr
(Infrared)
to see the button locations on the control panel.
Navigates downwards through the menu list and decreases the numeric value when in a function
Enables the currently displayed menu or sets the currently selected value into the selected function
Programming
Levels
C 1–19
P 1 4-color snap P 2 4-color pulse P 3 19-color snap P 4 19-color fade
. 1–1
Snd1 4-color snap Snd2 19-color snap
r. 0–255
G. 0–255
0–255
b.
0–255
A.
oFF diN1 diN2 diN3
oFF
on
Description
1: Red 6: Magenta 11: Sky 15: Pink 18: Peach 2: Green 7: Yellow 12: Hot pink 3: Blue 8: Orange 4: Amber 9: Lime 5: Cyan 10: Lavender 14: Salmon
00 Automatic program speed
Combine red, green, blue, and amber for a custom static color
Sets the dimmer speed
Enables/disables infrared control
13: Sea foam green
16: Powder blue
17: Bright yellow
19: White
Page 6 of 15
SlimPAR Q12 ILS User Manual Rev. 1
Operation

Configuration (DMX)

The SlimPAR Q12 ILS works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website: www.chauvetdj.com.

DMX Personality and Starting Address

When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If the starting address is too high, access to some of the product’s channels could be restricted.
The SlimPAR Q12 ILS uses up to 9 DMX channels in a 9-Ch DMX mode, which defines the highest configurable address to 504.
If unfamiliar with the DMX protocol, download the DMX Primer from: www.chauvetdj.com To select the starting address, do the following:
1. Press <MENU> repeatedly until 4-Ch or 9-Ch shows on the display.
2. Press <ENTER> and d 1–504 will show on the display.
3. Use <UP> or <DOWN> to select the starting address.
4. Press <ENTER>.
.

D-Fi USB Connectivity

The SlimPAR Q12 ILS is able to become a D-Fi wireless receiver/transmitter with the use of the D-Fi USB from Chauvet DJ. Simply set the product's DMX Personality and DMX Address, set the DIP switch D-Fi receiving/transmitting channel, then plug it into the D-Fi USB port.
WARNING! DO NOT plug anything other than a D-Fi USB into the USB port. Doing so may cause damage to the product.
Once plugged in, the D-Fi USB will take over the product. Wired DMX and manual display control / menu buttons will be unavailable until the D-Fi USB is unplugged. The priority levels are:
1. D-Fi USB
2. Wired DMX
3. Manual Digital Display/Menu Buttons

D-Fi USB Compatibility

The D-Fi USB can receive a DMX signal from the D-Fi Hub and the FlareCON Air 2 as well as other D-Fi USB products.

Configuration (D-Fi USB)

1. Set the DMX Personality and DMX address on the SlimPAR Q12 ILS .
2. Use the Chart provided to set BOTH:
the Channel, and then
The Receiving or Transmitting option
NOTE: DIP Switch 5
is for Transmitting OR Receiving, please choose carefully.
SlimPAR Q12 ILS User Manual Rev. 1
Page 7 of 15
Operation
Receiving
Receiving
Transmitting
Transmitting
D-Fi USB DIP Switch Channels
Ch. 1 2 3 4 T/R Ch. 1 2 3 4 T/R Ch. 1 2 3 4 T/R Ch. 1 2 3 4 T/R
1 9 1 9
2 10 2 10
3 11 3 11
4 12 4 12
5 13 5 13
6 14 6 14
7 15 7 15
8 16 8 16

DMX Values

4-Ch 9-Ch Function Value Percent/Setting
1 1 Red 000 255 0–100% 2 2 Green 000 255 0–100% 3 3 Blue 000 255 0–100% 4 4 Amber 000 255 0–100%
5 Color macros
Strobe (when Ch. 7 is 000031)
–6
7 Program
8 Dimmer 000 255
9 Dimmer speed
Program speed (when Ch. 7 is 032223)
Sound sensitivity (when Ch. 7 is 224255)
000 015 No function 016 255 Color macros 000 015 No function 016 255 Strobe, slow to fast
000 255 Program speed, slow to fast
000 010 Sound sensitivity off 011 255 Sound sensitivity, low to high 000 031 No function 032 063 Pulse effect, 0–100% (when Ch. 1-4 are active) 064 095 Pulse effect, 100–0% (when Ch. 1-4 are active) 096 127 Pulse effect, 100–0–100% (when Ch. 1-4 are active) 128 159 Automatic fade 160 191 Automatic 4-color snap 192 223 Automatic 19-color snap 224 255 Sound-active 19-color snap
0–100%
000 051 Dimmer speed set from display menu 052 101 Dimmer speed mode off 102 152 Dimmer speed mode 1 (fast) 153 203 Dimmer speed mode 2 (medium) 204 255 Dimmer speed mode 3 (slow)
Page 8 of 15
SlimPAR Q12 ILS User Manual Rev. 1
Operation

Configuration (Standalone)

Set the product in one of the standalone modes to control without a DMX controller.
Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.

Preset Color Mode

To run the SlimPAR Q12 ILS on a static color, follow the instructions below:
1. Press <MENU> repeatedly until C-- shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select a static color, from C 1–19.
4. Press <ENTER>.

Automatic Programs

To run the SlimPAR Q12 ILS in automatic mode, follow the instructions below:
1. Press <MENU> repeatedly until P-- shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to select an automatic program, from P 1–4.
4. Press <ENTER>.

Auto-Program Speed

To change the auto-program speed on the SlimPAR Q12 ILS , do the following:
1. Press <MENU> repeatedly until S-- shows on the display.
2. Use <UP> or <DOWN> to increase or decrease the program speed, from S. 1–100.
3. Press <ENTER>. The product will return to the last selected mode.

Sound-Active Programs

To run the SlimPAR Q12 ILS with a sound-active program, follow the instructions below.
1. Press <MENU> repeatedly until Snd shows on the display.
2. Use <UP> or <DOWN> to set the Sound-Active program, from Snd1 (4-color snap) to Snd2 (19-
color snap).
3. Press <ENTER>.

Sound Sensitivity

To set the sound sensitivity on the SlimPAR Q12 ILS , do the following:
1. Press <MENU> repeatedly until SenS shows on the display.
2. Use <UP> or <DOWN> to increase or decrease the sound sensitivity, from u 0–100.
3. Press <ENTER>.

Custom Color Mixing

To custom mix a static color, do the following:
1. Press <MENU> repeatedly until u-- shows on the display.
2. Press <ENTER> and one of the following will show on display.
r._ _ _ (red)
G._ _ _ (green)
b._ _ _ (blue)
A._ _ _ (amber)
3. Press <ENTER> to cycle through the color settings.
4. When the desired color shows on the display, use <UP> or <DOWN> to increase or decrease the color value, from 000–255.
5. Repeat steps 3 and 4 until the product outputs as desired.

Dimmer Curve

To set the dimmer curve, follow the instructions below:
1. Press <MENU> repeatedly until diN shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to set the dimmer curve, from oFF to diN1–3, with diN1 as the fastest and diN3 as the slowest.
4. Press <ENTER>.
SlimPAR Q12 ILS User Manual Rev. 1
Page 9 of 15
Operation
BLACK
OUT
AUTO
SOUND
SENSI­TIVITY
SPEEDSTROBE
%
MANUAL
FADE
RGB
WUVA
+
0
-
123
654
789

IRC-6 Infrared Remote Control

The SlimPAR Q12 ILS can be operated with the CHAUVET IRC-6. To enable IR wireless control, follow the instructions below.
1. Press <MENU> repeatedly until SEt shows on the display.
2. Press <ENTER>.
3. Press <UP> repeatedly until On shows on the display.
4. Press <ENTER>.

IRC-6 Operation

Automatic Mode
To turn on Automatic mode with the IRC-6:
1. Press <AUTO> on the IRC-6.
2. Press <+> or <-> to choose between the different auto programs.
To adjust the speed of the automatic program
1. Press <Speed> on the IRC-6.
2. Press <+> or <-> to increase or decrease the speed of the program.
Sound-Active Mode
To turn on Sound-Active mode with the IRC-6:
1. Press <SOUND> on the IRC-6.
2. Press <+> or <-> to select Snd1 or Snd2.
To adjust the sound sensitivity:
1. Press <SENSITIVITY> on the IRC-6.
2. Press <+> or <–> to increase or decrease the sound sensitivity.
Page 10 of 15
Manual Control
To manually select the color with the IRC-6:
1. Press the desired color, from <R> (red), <G> (green), <B> (blue), or <A>
(amber).
2. Press <+> or <-> to increase or decrease the percentage of each color.
Miscellaneous Operation
To adjust the total output level:
1. Press <%> on the IRC-6.
2. Press <+> or <-> to increase or decrease the output level.
To adjust the strobe rate of the program:
1. Press <STROBE> on the IRC-6.
2. Press <+> or <-> to increase or decrease the strobe rate.
3. Press <STROBE> again to turn off the strobe.
To select only fading programs:
1. Press <Fade> on the IRC-6.
2. Press <+> or <-> to select P 2 or P 4.
Black Out
To enable the black out function with the IRC-6:
1. Press <BLACK OUT> on the IRC-6.
This will turn off all the lights until the button is pressed again. NOTE: The IRC-6 will not respond to any inputs when Black Out is activated. If the product does not respond when a button is pressed, try pressing <BLACK OUT>. Black Out may have been activated.
Any setting on the IRC-6 will be saved until the system is rebooted. The system will
revert to Auto Mode after reboot.
The buttons on the IRC-6 not listed above are reserved for future use.
SlimPAR Q12 ILS User Manual Rev. 1
Operation

Master/Slave Mode

The Master/Slave mode allows a single SlimPAR Q12 ILS product (the “master”) to control the actions of one or more SlimPAR Q12 ILS products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in Standalone, whereas the slave products will be set to operate in Slave mode. Once set and connected, the slave products will operate in unison with the master product. Configure the products as indicated below.
Slave products:
1. Press <MENU> repeatedly until 4-Ch shows on the display.
2. Press <ENTER>.
3. Set the DMX address to d 1.
4. Connect the DMX input of the first slave product to the DMX output of the master product.
5. Connect the DMX input of the subsequent slave products to the DMX output of the previous slave product.
6. Finish setting and connecting all the slave products.
Master product:
1. Press <MENU> repeatedly to go to the desired function or program.
2. Press <ENTER>.
3. Set the master product to operate in standalone.
4. Make the master product the first product in the DMX daisy chain.
Configure all the slave products before connecting the master to the daisy chain.
Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master.
Do not connect more than 18 slaves to the master.

Master/Slave Mode (D-Fi USB)

The D-Fi USB allows a single SlimPAR Q12 ILS product (the “master”) to control the actions of one or more SlimPAR Q12 ILS products (the “slaves”) without the need of a DMX controller or DMX cables. The master (transmitter) product will be set to operate in standalone mode, while the slave (receiver) products will be set to operate in DMX mode. Once set and connected, the slave products will operate in unison with the master product. Configure the products as indicated below.
Slave products:
1. Press <MENU> repeatedly until 4-Ch shows on the display.
2. Press <ENTER>.
3. Use <UP> or <DOWN> to set the starting address to d 1.
4. Press <ENTER>.
5. Set the D-Fi USB to receive on a specific channel, 1–16.
6. Plug in the D-Fi USB.
7. Finish setting and connecting all the slave products.
Master product:
1. Set the master product to operate in standalone mode.
2. Set the D-Fi USB to transmit on the D-Fi channel the slaves are receiving on.
3. Plug in the D-Fi USB.
All products must be set to the same DMX personality, DMX address, and D-Fi channel.
Configure all the slave products before configuring the master to transmit.
Never connect a DMX controller to a D-Fi channel configured for Master/Slave operation because the controller may interfere with the signals from the master.

ILS Mode

ILS (Integrated Lighting System) provides 4 modes that synchronize with the GigBAR MOVE+ILS: Modes 1 and 3 synchronize with side 1 of the GigBAR MOVE+ILS, whereas modes 2 and 4 synchronize with side 2 of the GigBAR MOVE+ILS. When linked, effects will sync with the most similar effect on the selected side of the GigBAR MOVE+ILS: Kinta effects will sync with one of the kintas, moving heads will sync with one of the moving heads, and wash effects will sync with one of the pars. Laser effects will sync with the laser, and strobe effects will sync with the strobe effects regardless of ILS mode.
This product will synchronize with the par effect on the selected side of the GigBAR MOVE+ILS. To set the SlimPAR Q12 ILS to respond to an ILS signal:
1. Press <MENU> repeatedly until iLS shows on the display.
2. Use <UP> or <DOWN> to select from iLS1 (side 1), iLS2 (side 2), iLS3 (side 1), or iLS4 (side 2).
3. Press <ENTER>.
SlimPAR Q12 ILS User Manual Rev. 1
Page 11 of 15
Maintenance

5. Maintenance

Product Maintenance

Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1. Unplug the product from power.
2. Wait until the product is at room temperature.
3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
5. Apply the solution directly to a soft, lint-free cotton cloth or a lens-cleaning tissue.
6. Softly drag any dirt or grime to the outside of the transparent surface.
7. Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Page 12 of 15
SlimPAR Q12 ILS User Manual Rev. 1
Technical

6. Technical Specifications

Dimensions and Weight

Length Width Height Weight
9.7 in (247 mm) 3.6 in (92 mm) 11.5 in (293 mm) 3.6 lb (1.6 kg)
Note: Dimensions in inches rounded to the nearest hundredth.

Power

Power Supply Type Range Voltage Selection
Switching (internal) 100 to 240 VAC, 50/60 Hz Auto-ranging
Parameter 120 V, 60 HZ 230 V, 50 HZ
Consumption 55 W 54 W
Operating current 0.8 A 0.5 A
Power-linking current (products) 8 A (10 products) 8 A (18 products)
Fuse T 1.6 AL, 250 V T 1.6 AL, 250 V
Power I/O U.S./Canada Worldwide
Power input connector IEC IEC
Power output connector Edison IEC
Power cord plug Edison (U.S.) Local plug

Light Source

Type Quantity Color Power Current Lifespan
LED 12 Quad-color RGBA 6 W 2.3 A 50,000 hours

Photometrics

Parameter Value
Strobe rate 0 to 17 Hz
Beam angle 17°
Field angle 29°
Illuminance @ 2 m 2,684 lux

Thermal

Maximum External Temperature Cooling System
104 °F (40 °C) Convection
DMX
I/O Connector Channel Range
3-pin XLR 4 or 9

Ordering

Product Name Item Code UPC Number
SlimPAR Q12 ILS 10031894
781462222420
SlimPAR Q12 ILS User Manual Rev. 1
Page 13 of 15

Warranty & Returns

Warranty & Returns

Limited Warranty

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty-registration
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
.

Returns

In case support or return of a product is needed:
If located in the U.S., contact Chauvet World Headquarters.
If located in the U.K. or Ireland, contact Chauvet U.K.
If located in Benelux, contact Chauvet Benelux.
If located in France, contact Chauvet France.
If located in Germany, contact Chauvet Germany.
If located in Mexico, contact Chauvet Mexico.
If located in any other country, DO NOT contact Chauvet. Instead, contact a local distributor. See
www.chauvetdj.com
Mexico.
If located outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico contact the distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetdj.com
for distributors outside the U.S., U.K., Ireland, Benelux, France, Germany, or
for contact details.
.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return.
Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags.
Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.
Before sending the product, clearly write the following information on a piece of paper and place it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.
Chauvet reserves the right to use its own discretion to repair or replace returned product(s).
Page 14 of 15
SlimPAR Q12 ILS User Manual Rev. 1

Contact Us

Contact Us
Chauvet World Headquarters
Chauvet U.K.
Chauvet Benelux
Chauvet France
Chauvet Germany
Chauvet Mexico
Address: Av. de las Partidas 34 - 3B
General Information Technical Support
Address: 3360 Davie Rd. Voice: (844) 393-7575
Davie, FL 33314 Fax: (954) 756-8015
Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com
Fax: (954) 929-5560
Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetprofessional.eu
NG16 6NT
Voice: + 4 4 (0) 17 7 3 511115
Fax : + 44 (0) 1 7 7 3 511110
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetprofessional.eu
Voice: +32 9 388 93 97
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France Website: www.chauvetprofessional.eu
Voice: +33 1 78 85 33 59
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany Website: www.chauvetprofessional.eu
Voice: +49 421 62 60 20
(Entrance by Calle 2)
Zona Industrial Lerma Website: www.chauvetprofessional.mx
Lerma, Edo. de México, CP 52000
Voice: +52 (728) 690-2010
Email: FRtech@chauvetlighting.fr
Email: DEtech@chauvetlighting.de
Email: servicio@chauvet.com.mx
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record. Fol­low the instructions to request support or to return a product. Visit our website for contact details.
SlimPAR Q12 ILS User Manual Rev. 1
Page 15 of 15
Loading...