Service Bulletin
Issued by Canon Europa N.V.
Copier Color
HARDWARE
Model:
iR5800C
iR5800CN
iR5870C
iR5870Ci
iR6800C
iR6800CN
iR6870C
iR6870Ci
Revised:
Addition of affected machines
Location:
Intermed. Transfer Belt Ass’y
Subject:
Measures against the displaced reflecting surface of the transfer belt
Detail:
<Symptom>
In printing or copying, the following kinds of faulty images are printed: image with the upper and lower parts
put in the other way around (P-1), image with changed color tone (P-2), and image with no margin at the leading
and trailing edges.
Ref No.:
iR6800C-034 Rev. 1
(F2-T01-0M3-10090-02)
Date:
May 2006
<Cause>
The reflecting surface [A] on the inner surface of the transfer belt is displaced, preventing the ITB home position
signal from being detected at the correct time. The degree of displacement of the reflecting surface [A] and the
type of job (i.e., the type of paper used, the number of copies specified, etc) at that time cause the symptom.
(1/3)
P-3 INTERMED. TRANSFER BELT ASS'Y BELT
iR6800C-034 Rev. 1
[A] REFLECTING SURFACE
<Factory Measures>
Change the size of the reflecting surface from 15 mm X 27 mm to 15 mm X 40 mm, and widen the area of the
adhesive bonding to prevent the surface from becoming displaced.
Service Work:
When the foregoing symptom occurs, replace the transfer belt by a new type.
Service Parts:
No. Part number Description Q'ty Stock
Old FC5-1658-000
1
New FC5-1658-020 0->1 D Y In stock
BELT,
TRANSFER
1->0 C N
Interchange
ability
Stock Date P.C.
537
(2/3)