Canon iR5870C, iR5870Ci, iR6870C, iR6870Ci ir6800c-027

Service Bulletin
Office Imaging Products Device Quality Assurance Center
Copier Color
HARDWARE
Model: iR 5800C
iR 5800CN iR 5870C iR 5870Ci iR 6800C iR 6800CN iR 6870C iR 6870Ci
Revised:
Addition of affected machines.
Location:
Subject:
Countermeasure against the error occurrence, E202-0001/0002, due to the breakage of IC6
Detail:
<Symptom> The errors, E202-0001/0002, occur due to the breakage of IC6 [1] <Cause> The installation or uninstallation of the Flexible Flat Cable [2], which controls the current flow into the Scanner Drive Motor, may not have been done successfully, #34 may be broken, an overcurrent may flow into the Interface PCB, the IC6 [1] may be broken and may lead to occur smoking.
Ref No.:
iR6800C-027 Rev. 2 (F2-T01-0M3-10064-03)
Date:
April, 2006
(1/4)
P-1 Interface PCB Assembly
[1] IC6 [2] Cable, Flexible Flat
<Factory measures>
1.Temporary countermeasure Add Chip Resistor to C49 (unused part) [3] on the Interface PCB.
iR6800C-027 Rev. 2
P-2 Enlarged view of Interface PCB
[3] C49 Resistor added part
Revision number sealed place (last two
[4]
figures show the revision number)