Service Bulletin
Office Imaging Products Device Quality Assurance Center
Copier Color
HARDWARE
Model:
iR 5800C
iR 5800CN
iR 5870C
iR 5870Ci
iR 6800C
iR 6800CN
iR 6870C
iR 6870Ci
Revised:
Addition of affected machines.
Location:
Reader Frame Assembly
Subject:
Countermeasure against the error occurrence, E202-0001/0002, due to the breakage of IC6
Detail:
<Symptom>
The errors, E202-0001/0002, occur due to the breakage of IC6 [1]
<Cause>
The installation or uninstallation of the Flexible Flat Cable [2], which controls the current flow into the Scanner Drive
Motor, may not have been done successfully, #34 may be broken, an overcurrent may flow into the Interface PCB,
the IC6 [1] may be broken and may lead to occur smoking.
Ref No.:
iR6800C-027 Rev. 2
(F2-T01-0M3-10064-03)
Date:
April, 2006
(1/4)
P-1 Interface PCB Assembly
[1] IC6
[2] Cable, Flexible Flat
<Factory measures>
1.Temporary countermeasure
Add Chip Resistor to C49 (unused part) [3] on the Interface PCB.
iR6800C-027 Rev. 2
P-2 Enlarged view of Interface PCB
[3] C49 Resistor added part
Revision number sealed place (last two
[4]
figures show the revision number)
(2/4)