WARNING: The appliance and its accessible parts become hot during use. Care should be taken to avoid
touching heating elements.
• Children under 8 Year of age must be kept away from the appliance unless they are continuously
supervised.
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved.
• Children must not play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
WARNING: Unattended cooking on a hob with fat or oil can be dangerous and may result in fire.
NEVER try to extinguish a fire with water, but switch off the appliance and then cover flame e.g. with a lid
or a fire blanket.
WARNING: Danger of fire: do not store items on the cooking surfaces.
WARNING: Accessible parts may become hot during use. Young children must be kept away.
• Do not use a steam cleaner for cleaning operations.
• Any spillage should be removed from the lid before opening.
• The hob surface must be allowed to cool down before closing the lid.
• This appliance is not intended to be operated by means of an external timer or separate remote-control
system.
• The means for disconnection must be incorporated in the fixed wiring in accordance with the wiring
rules.
• The instructions state the type of cord to be used, taking into account the temperature of the rear surface
of the appliance.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance
must not be supplied through an external switching device, such as a timer, or connected to a circuit that
is regularly switched on and off by the utility.
• This appliance must be installed in accordance with the regulations in force and only used in a well
ventilated space. Read the instructions before installing or using this appliance.
• These instructions are only valid if the country symbol appears on the appliance. If the symbol does not
appear on the appliance, it is necessary to refer to the technical instructions which will provide the
necessary instructions concerning modification of the appliance to the conditions of use of the country.
• Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and
the adjustment of the appliance are compatible;
• The adjustment conditions for this appliance are stated on the label (or data plate);
• This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
• The use of a gas cooking appliance results in the production of heat and moisture in the room in which it
is installed. Ensure that the kitchen is well ventilated: keep natural ventilation holes open or install a
mechanical ventilation device (mechanical extractor hood). Prolonged intensive use of the appliance
may call for additional ventilation, for example opening of a window, or more effective ventilation, for
example increasing the level of mechanical ventilation where present.
04 GB
1. INSTRUCTIONS FOR THE INSTALLER
INSTALLING A DOMESTIC APPLIANCE CAN BE A COMPLICATED OPERATION WHICH IF NOT CARRIED OUT CORRECTLY, CAN
SERIOUSLY AFFECT CONSUMER SAFETY. IT IS FOR THIS REASON THAT THE TASK SHOULD BE UNDERTAKEN BY A
PROFESSIONALLY QUALIFIED PERSON WHO WILL CARRY IT OUT IN ACCORDANCE WITH THE TECHNICAL REGULATIONS IN
FORCE. IN THE EVENT THAT THIS ADVICE IS IGNORED AND THE INSTALLATION IS CARRIED OUT BY AN UNQUALIFIED PERSON,
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR ANY TECHNICAL FAILURE OF THE PRODUCT WHETHER OR NOT IT
RESULTS IN DAMAGE TO GOODS OR INJURY TO INDIVIDUALS.
1.1 BUILDING IN
The hob may be installed in any worktop which is heat resistant to a
temperature of 100°C, and has a thickness of 25-45 mm. The
dimensions of the insert to be cut out of the worktop are in shown in
Figure 2.
If the Hob is fitted next to a cabinet on either side, the distance
between the Hob and the cabinet must be at least 15 cm (see Figure
4); while the distance between the hob and the rear wall must be at
least 5,5 cm.
The distance between the hob and any other unit or appliance above it
(e.g. An extractor hood) must be no less than 70 cm (Figure 4).
When there is an accessible space between the built-in hob and the
cavity below, a dividing wall made of insulating material should be
inserted (wood or a similar material) (Figure 3).
Important - The diagram in figure 1 shows how the sealant should
be applied.
The Hob unit is fitted by attaching the Fixing Clamps supplied, using
the holes at the base of the unit.
If a hob of 60 cm is fitted above an oven which is not equipped with fan
cooling system it is recommended that openings are created within
the built in furniture to ensure correct air circulation.
The size of these openings must be at least 300 cm2 and placed as
shown in Figure 5.
1.2. SUITABLE LOCATION
A gas-powered cooking appliance produces heat and humidity in the
area in which it is installed. For this reason you should ensure good
ventilation either by keeping all natural air passages open or by
installing an extractor hood with an exhaust flue. Intensive and
prolonged use of the appliance may require extra ventilation, such as
the opening of a window or an increase in speed of the electric fan, if
you have one.
If a hood can not be installed, an electric fan should be fitted to an
outside wall or window to ensure that there is adequate ventilation.
The electric fan should be able to carry out a complete change of air in
the kitchen 3-5 times every hour. The installer should follow the
relevant national standards.
2. ELECTRICAL CONNECTION (FOR U.K. ONLY)
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the
main supply must be made by a competant electrician, ensuring that
all current regulations concerning such installations are observed.
The appliance must only be connected to a suitably rated spur point, a
3 pin 13 amp plug/socket is not suitable. A double pole switch must be
provided and the circuit must have appropriate fuse protection.
Further details of the power requirement of the individual product will
be found in the users’ instruction and on the appliance rating plate. In
the case of built-in product you are advised, should you wish to use a
longer cable than the one supplied, that a suitably rated heat resistant
type must be used.
The wiring must be connected to the mains supply as follows:
CONNECTTO SPUR TERMINAL
Green & Yellow Wire Earth Connection
Blue Wire Neutral Connection
Brown Wire Live Connection
Note: We do not advocate the use of earth leakage devices with
electric cooking appliances installed to spur points because of the
«nuisance tripping» which may occur. You are again reminded that the
appliance must be correctly earthed, the manufacturer declines any
responsibility for any event occurring as a result of incorrect electrical
installation.
2.1. ELECTRICAL CONNECTION
Check the data on the rating plate, located on the outside of the unit, to
ensure that the supply and input voltage are suitable.
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this regulation is not
complied with, the Manufacturer will not be responsible for any
damage caused to persons or property. If a plug is not already
attached, fit a plug appropriate to the load indicated on the rating plate.
The earth wire is coloured yellow/green. The plug should always be
accessible.
Where the Hob is connected direct to the electricity supply, a circuit
breaker must be fitted.
If the power supply cord is damaged this is to be replaced by a
qualified engineer so as to prevent any potential risk.
The earth wire ( green and yellow coloured ) must be at least 10 mm
longer than the live and neutral wires.
The section of the cable used must be of the correct size in relation to
the absorbed power of the hob.
Please check rating plate for the power details and ensure that the
power supply cord is of the type H05RR F, H05VV-F, F-H05V2V2.
LIVE
Mains Supply
If an appliance is not fitted with a supply cord and a plug, or with other
means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under
overvoltage category III conditions, the instructions shall state that
means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
EARTH
NEUTRAL
Brown Wire
L
Green/Yellow Wire
Blue Wire
N
Power Cable
2.2. GAS CONNECTION
These instructions are for qualified personnel, installation of
equipment must be in line with the relevant national standard. (For
U.K. only: by law the gas installation\commissioning must be
carried out by a "Gas Safe" installer)
All work must be carried out with the electricity supply disconnected.
The rating plate on the hob shows the type of gas with which it is
designed to be used. Connection to the mains gas supply or gas
cylinder should be carried out after having checked that it is regulated
for the type of gas with which it will be supplied. If it is not correctly
regulated see the instructions in the following paragraphs to change
gas setting.
For liquid gas (cylinder gas) use pressure regulators which comply
with the relevant national standards.
Use only pipes,washers and sealing washers which comply with the
relevant national standards.
For some models a conic link is furnished to outfit for the installation in
the countries where this type of link is obligatory; in picture 8 it is
pointed out how to recognize the different types of links (CY =
cylindrical, CO = conic). In every case the cylindrical part of the link
has to be connected to the hob.
When connecting the hob to the gas supply via use offlexible hoses
please ensure that the maximum distance covered by the hose does
not exceed 2 metres.
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit (e.g. a drawer) and
does not pass through any space where it may become crushed/
kinked or damaged in any way.
To prevent any potential damage to the hob please carry out the
installation following this sequence (picture 6):
05 GB
1)As illustrated, assemble parts in sequence:
A: 1/2 Male Adaptor Cylindirical
B: 1/2 Seal
C: 1/2 Female Gas Adaptor Conical-Cylindirical or
Cylindirical-Cylindirical
2)Tighten the joints with the spanner, remembering to twist the
pipes into position.
3)Attach fitting C to mains gas supply using rigid copper pipe or
flexible steel pipe.
IMPORTANT: carry out a final check for leaks on the pipe
connections using a soapy solution. NEVER USE A FLAME. Also,
make sure that the flexible pipe cannot come into contact with a
moving part of the cabinet (eg.adrawer) and that it is not situated
where it could be damaged.
Warning: If gas can be smelt in the vicinity of this appliance turn off the
gas supply to the appliance and call the engineer directly. Do not
search for a leak with a naked flame.
2.3. ADAPTING THE HOB TO DIFFERENT
TYPES OF GAS
To adapt the Hob for use with different types of gas, carry out the
following instructions:
•remove the grids and burners
•insert on hexagonal spanner (7 mm) into the burner support (Figure
7)
•Unscrew the injector and replace it with one suitable for the gas to be
used (see gas type table)
2.4. REGULATING THE MINIMUM FLAME
After lighting the burners, turn the control knob to the minimum setting
and then remove the knob (this can easily be removed by applying
gentle pressure).
Using a small «Terminal» type screwdriver the regulating screw can
be adjusted as in Figure 9. Turning the screw clockwise reduces the
gas flow, whilst turning it anticlockwise increases the flow – Use this
adjustment to obtain a flame of approximately 3 to 4 mm in length and
then replace the control knob.
When the gas supply available is LPG - the screw to set the idle flame
must be turned (clockwise) to the end stop.
When you have carried out the new gas regulation, replace the old gas
rating plate on your appliance with one (supplied with hob) suitable for
the type of gas for which it has been regulated.
3. USE OF HOB - USER INSTRUCTIONS
This appliance must only be used for the purpose for which it is
intended, domestic cooking, and any other use will be considered
improper and could therefore be dangerous. The Manufacturer will
not be responsible for any damage or loss resulting from improper
use.
3.1. USING THE GAS BURNER
To ignite the burners, place a lighted taper close to the burner, press in
and turn the control knob anti-clockwise.
If the burners have not been used for a couple of days, wait for a few
seconds before lighting the burner, this will allow any air present in the
pipes to escape.
For appliances fitted with electronic ignition carry out the following:
• push in and turn the knob anticlockwise to the ignition symbol.
• ignite the burner by pressing the sparker button.
For hobs fitted with automatic ignition simply push in and turn the knob
to the ignition symbol.
The ignition system will continue to generate sparks as long as the
control knob is being pressed.
If the burner has not ignited within 5 seconds, turn the knob to the 0
position and repeat the operation.
For models fitted with a safety tap (which cuts-off the flow of gas if the
flame is accidentally extinguished) the burners are ignited and
described above, but care must be taken.
Prior to switching on the gas hob ensure that the burners and burner
caps are correctly placed within their position.
Burner Type
Auxiliary
AUX
Semi Rapid
SR
Rapid
R
For smaller containers the gas burner should be regulated so that the
flame does not overlap the base of the pan. Vessels with a concave or
convex base should not be used.
WARNING: If a flame is accidentally extinguished, turn the knob
to the off position and do not attempt to re-ignite if for at least 1
minute.
If over the years the gas taps become stiff to turn it is necessary to
lubricate them.
Such operation must be carried out only by qualified Service
Engineers.
Suitability of Cooking Pans (Figure 10)
Keep in mind that larger pans have larger heating surfaces.
This will help them to cook the food faster than pans with smaller
heating surfaces.
Always use pan sizes proportionate to the amount of the food to be
cooked. In order to prevent splashing, do not use very small pans,
especially for foods with excess liquid. If you use excessively large
pans for quick cooked foods, sausages and liquids will stick and
residues will remain attached to the pan after being emptied.
Closed pans and baking trays or moulds are suggested for cooking
sweets. Splashed sugar and juices from an open pan may stick to the
cooker surface and will be difficult to remove.
This is especially important for pans used for roasting or pressurized
cooking at high temperature.
Do not leave burners unattended without a pan or with an empty pan
on top.
Check the suitability of cooking pans with respect to the following
criteria;
They should be heavy.
They should completely cover the burner surface; they may be a little
bigger but no smaller. (See Table)
Ø pan/pot
(cm)
12 - 18
18 - 24
24 - 26
Power
(kW)
1,00
1,75
2,50
G20/20 mbar
(methane)
95 l/h
167 l/h
238 l/h
G30/28-30 mbar
(LPG)
73 g/h
127 g/h
182 g/h
Table A
4. MAINTENANCE AND CLEANING
Before cleaning the hob, ensure the appliance has cooled down.
Remove the plug from the socket or (if connected directly) switch off
the electricity supply.
Never use abrasives, corrosive detergents, bleaching agents or
acids. Avoid any acid or alkaline substances (lemon, juice, vinegar
etc.) on the enamelled, varnished or stainless steel sections.
When cleaning the enamelled, varnished or chrome sections, use
warm soapy water or a non caustic detergent. For stainless steel use
an appropriate cleaning solution.
The burners can be cleaned with soapy water. To restore their original
shine, use a household stainless steel cleaner. After cleaning, dry the
burners and replace.
It is important the Burners are replaced correctly.
5. AFTERCARE
Before calling out a Service Engineer please check the following:
• that the plug is correctly inserted and fused;
• that the gas supply is not faulty.
If the fault cannot be detected:
Switch off the appliance and call the After Service Centre. DO NOT
TAMPER WITH THE APPLIANCE.
GENERAL ADVISE
For best results, use cooking vessels with a flat surface. The size of
the surface should match the gas burner side as follows. Table A.
06 GB
6. PROTECTION OF THE ENVIRONMENT
This appliance is marked according to the European
directive 2012/19/EU on Waste Electrical and
Electronic Equipment (WEEE). WEEE contains both
polluting substances (which can cause negative
consequences for the environment) and basic
components (which can be re-used). It is important to
have WEEE subjected to specific treatments, in order
recover and recycle all materials.
Individuals can play an important role in ensuring that WEEE does not
become an environmental issue; it is essential to follow some basic
rules:
• WEEE shall not be treated as household waste.
• WEEE shall be handed over to the relevant collection points
managed by the municipality or by registered companies. In many
countries, for large WEEE, home collection could be present.
• When you buy a new appliance, the old one may be returned to the
retailer who has to collect it free of charge on a one-to-one basis, as
long as the equipment is of equivalent type and has the same functions
as the supplied equipment.
Declaration of compliance: This equipment, in the parts intended to
come into contact with food, complies with the regulations laid down in
EEC directives 89/109.
Appliance complies with European Directives 2006/95/EC,
2004/108/EC and 2009/142/EC and subsequent
amendments.
The Manufacturer will not be responsible for any inaccuracy resulting
from printing or transcript errors contained in this brochure. We
reserve the right to carry out modifications to products as required,
including the interests of consumption, without prejiudice to the
characteristics relating to safety or function.
to remove and dispose properly all pollutants, and
BUILT IN HOBS
Burner
R /2SR / AUX
Type / reference
Flame failure device
Auxiliary burner ( AUX Ø 50 mm)
Semirapid burner ( SR Ø 75 mm)
Rapid burner ( R Ø 100 mm)
Installed Gas Type / Power:
Gas Power
G 20/20 mbar (methane)
G 30/28-30 mbar (LPG)
Installation Class
Voltage / Frequency V / Hz
Electrical input power
Electric ignition
Product dimension
This appliance has been designed for non-professional,
i.e. domestic, use.
PVL6SL
220-240 V / 50-60 Hz
Table 1
1
4 gas
YES
1
2
1
7.0 kW
666 l/h
509 g/h
3
25 W
YES
585 x 510
07 GB
INSTRUKCJE BEZPIECZEŃSTWA
UWAGA: Podczas pracy urządzenie oraz jego elementy są gorące. Należy zachowac ostrożność i nie
dotykać gorących części.
• Dzieci w wieku do 8 lat nie mogą zbliżać się do urządzenia chyba że pozostaja one pod ciągłym
nadzorem.
• Dzieci w wieku powyżej 8 lat oraz ososby z ograniczeniami ruchowymi, umysłowymi, czuciowymi lub
nie posiadające odpowiedniej wiedzy lub doświadczenia mogą obsługiwać urządzenie jedynie pod
nadzorem lub po przeszkoleniu odnośnie bezpiecznego użytkowania urządzenia i związanych z tym
zagrożeń.
• Dzieci nie mogą bawić się urządzeniem.
• Dzieci bez nadzoru nie mogą obsługiwac ani czyścić urządzenia.
UWAGA: gotowanie na płycie z użyciem oleju lub tłuszczu bez nadzoru może być niebezpieczne i
spowodować pożar.
• NIGDY nie gasić ognia wodą, należy wyłączyc urządzenie i przykryć płomień np. pokrywką lub kocem
ognioodpornym.
UWAGA: niebezpieczeństwo pożaru. Nie wolno przchowywać przedmiotów na powierzchniach
grzejnych.
UWAGA: dostępne części mogą być gorące podczas użytkowania. Dzieci nie mogą zbliżać się do
urządzenia.
• Nie stosować do czyszczenia urządzeń parowych.
• Usunąć wylany płyn z pokrywy przed otwarciem.
• Poczekać aż powierzchnia płyty ostygnie przed zamknięciem pokrywy.
• Urządzenie nie jest przeznaczone do sterowania zewnętrznym minutnikiem lub oddzielnym układem
zdalnego sterowania.
• Wyłącznik musi być podłączony do okablowania zgodnie z obowiązujacymi przepisami.
instrukcja musi określać jaki rodzaj przewodu może być zastosowany, z uwzglednieniem temperatury
tylnej ścianki urządzenia.
• Jeżeli przewód zasilający jest uszkodzony musi być wymieniony przez producenta lub autoryzowany
serwis tak aby uniknąc wszelkiego ryzyka.
UWAGA: w celu uniknięcia zagrożeń związanych z przypadkowym zadziałaniem zabezpieczeń
termicznych urządzenie nie może być zasilane z sieci sterowanej niezależnie lub z obwodów które są
regularnie włączane i wyłączane.
• Urządzenie musi być zainstalowane zgodnie z obowiązującymi przepisami i w miejscu dobrze
wentylowanym. Proszę zapoznać się z instrukcją przed przystapieniem do instalacji.
Te instrukcje są ważne jedynie dla krajów których symbol pojawia się na urządzeniu. Jeżeli symbol kraju
jest nieobecny należy odnieść się do insterukcji technicznej określającej zmiany urządzenia
wprowadzone dla danego kraju.
• Przed instalacją należy upewnić się czy lokalne warunki (rodzaj i ciśnienie gazu) są zgodne z
ustawieniami urządzenia;
• Ustawienia urządzenia są podane na tabliczce znamionowej;
• Urządzenie nie jest podłączone do układu odprowadzania gazów spalinowych. Musi być podłączone
do takiego układu zgodnie z przepisami ze szczególnym uwzględnieniem wymagań odnośnie wentylacji
.
08 PL
1. INSTRUKCJE DLA INSTALATORA
INSTALACJA URZĄDZENIA DOMOWEGO MOŻE BYĆ SKOMPLIKOWANĄ OPERACJĄ, KTÓRA JEŻELI NIE BĘDZIE WYKONANA
PRAWIDŁOWO, MOŻE POWAŻNIE ZAGROZIĆ BEZPIECZEŃSTWU UŻYTKOWNIKA. DLATEGO TEŻ, ZADANIE TO POWINNO BYĆ
WYKONANE PRZEZ OSOBĘ O ODPOWIEDNICH KWALIFIKACJACH ORAZ ZGODNIE Z OBOWIĄZUJĄCYMI PRZEPISAMI. W
PRZYPADKU ZIGNOROWANIA NINIEJSZEGO ZALECENIA I WYKONANIA INSTALACJI PRZEZ OSOBĘ BEZ ODPOWIEDNICH
KWALIFIKACJI, PRODUCENT NIE PONOSI ŻADNEJ ODPOWIEDZIALNOŚCI ZA JAKIEKOLWIEK USTERKI TECHNICZNE, BEZ
WZGLĘDU NA TO, CZY SPOWODUJĄ ONE SZKODY W MIENIU, CZY TEŻ USZKODZENIA CIAŁA U LUDZI.
1.1. ZABUDOWA
Płytę można zamontować w dowolnym blacie kuchennym, który jest
odporny na działanie temperatury do 100C oraz posiada grubość 25-45
mm. Wymiary otworu, który należy wyciąć w blacie kuchennym, podane
są na Rysunku 2.
Jeżeli kuchenka jest montowana obok szafki kuchennej, odległość
pomiędzy płytą i szafką musi być co najmniej 15 cm (patrz Rysunek 4);
natomiast odległość pomiędzy płytą i ścianą kuchni musi być co najmniej
5,5 cm.
Odległość pomiędzy płytą i szafką lub jakimkolwiek urządzeniem
zamontowanym nad kuchenką (np. okapem) musi być nie mniejsza niż
70 cm (Rysunek 4).
Jeżeli pod zabudowaną płytą znajduje się dostępna przestrzeń,
konieczne jest zamontowanie przegrody z materiału izolacyjnego (np.
drewna) (Rysunek 3).
Uwaga - Na Rysunku 1 pokazano sposób przyklejenia uszczelki.
Płytę należy zamocować przy użyciu uchwytów znajdujących się w jej
wyposażeniu, korzystając z otworów wykonanych w podstawie płyty.
W przypadku montowania płyty o szerokości 60 cm nad piekarnikiem,
który nie jest wyposażony w obieg chłodzący, zaleca się utworzenie
otworów w zabudowie w celu zapewnienia prawidłowego przepływu
powietrza.
Wielkość tych otworów powinna wynosić co najmniej 300 cm i należy je
rozmieścić w sposób pokazany na Rysunku 5.
2
1.2. ODPOWIEDNIE POMIESZCZENIE
W przestrzeni, w której zainstalowana jest kuchenka gazowa powstają
duże ilości ciepła i pary. Dlatego też, konieczne jest zapewnienie dobrej
wentylacji poprzez utrzymywanie naturalnego obiegu powietrza lub
poprzez zamontowanie okapu kuchennego z wyciągiem. W przypadku
długiego i intensywnego użytkowania kuchenki, konieczne może być
zastosowanie dodatkowej wentylacji, na przykład poprzez otwarcie okna
lub zwiększenie obrotów wentylatora.
•Przed instalacją należy upewnić się czy lokalne warunki (rodzaj i
ciśnienie gazu) są zgodne z ustawieniami urządzenia;
•Ustawienia urządzenia są podane na tabliczce znamionowej;
•Urządzenie nie jest podłączone do układu odprowadzania gazów
spalinowych. Musi być podłączone do takiego układu zgodnie z
przepisami ze szczególnym uwzględnieniem wymagań odnośnie
wentylacji .
Przy braku możliwości zamontowania okapu, w ścianie zewnętrznej lub
w oknie należy zainstalować wentylator elektryczny pod warunkiem, że
pomieszczenie posiada otwory odpowietrzające.
Wentylator elektryczny powinien zapewniać pełną wymianę powietrza w
kuchni w tempie 3-5 razy na godzinę. Instalator powinien przestrzegać
obowiązujących w danym kraju przepisów.
2.1. PODŁĄCZENIE DO SIECI ELEKTRYCZNEJ
Upewnić się, że napięcie w sieci odpowiada napięciu podanemu na
tabliczce znamionowej znajdującej się na obudowie urządzenia.
Przed podłączeniem, sprawdzić obwód uziemienia.
Zgodnie z przepisami prawa, niniejsze urządzenie musi być uziemione.
W razie nie przestrzegania tego wymagania, producent nie poniesie
żadnej odpowiedzialności za jakiekolwiek szkody w stosunku do osób
lub mienia. Jeżeli kabel zasilający nie posiada wtyczki, należy
zamontować wtyczkę dopasowaną do obciążenia wskazanego na
tabliczce znamionowej urządzenia. Przewód uziemienia jest w kolorze
żółtozielonym. Wtyczka powinna być zawsze dostępna.
W przypadku gdy płyta podłączona jest bezpośrednio do sieci
elektrycznej, konieczne jest zainstalowanie wyłącznika automatycznego.
W razie uszkodzenia kabla zasilającego, musi on być wymieniony przez
wykwalifikowanego elektryka w celu wyeliminowania potencjalnych
zagrożeń.
Przewód uziemienia (w kolorze żółtozielonym) musi być co najmniej 10
mm dłuższy niż przewód fazowy i neutralny.
Przekrój poprzeczny kabla zasilającego musi być o wielkości
dostosowanej do mocy pobieranej przez płytę.
Sprawdzić na tabliczce znamionowej dane dotyczące podłączenia do
sieci elektrycznej oraz upewnić się, że kabel zasilający jest typu 3x0.75
mm² H05RR-F.
Zacisk sieci
zasilającej
Jeśli urządzenie nie posiada kabla i wtyczki lub innego rozwiązania
umożlwiającego odłączenie od odpowiednio zabezpieczonej sieci
elektrycznej pozwalającej na pełne odłączenie przy wystąpieniu
nadnapięcia spełniającego warunki kategorii III,instrukcja stwierdza, że
sposoby odłączenia muszą być wbudowane w instalację elektryczną,
zgodnie z zasadami okablowania.
FAZOWY
UZIEMIENIE
NEUTRALNY
Przewód brązowy
L
Przewód żółtozielony
Przewód niebieski
N
2.2. PODŁĄCZENIE DO GAZU
Poniższe instrukcje przeznaczone są dla wykwalifikowanego personelu,
instalacja urządzenia musi być zgodna z obowiązującymi normami
krajowymi. (Wyłącznie dla Wielkiej Brytanii: zgodnie z przepisami
prawa, instalacja gazowa i jej odbiór muszą być przeprowadzone
przez instalatora zarejestrowanego w CORGI)
Wszystkie prace muszą być wykonane przy odłączonym zasilaniu
elektrycznym.
Na tabliczce znamionowej urządzenia wskazany jest rodzaj gazu do
którego zostało ono przystosowane. Podłączenie do sieci gazowej lub
do butli z gazem płynnym należy przeprowadzić po uprzednim
upewnieniu się, że urządzenie jest wyregulowane dla danego rodzaju
gazu, który ma być podłączony. Jeżeli urządzenie nie jest prawidłowo
wyregulowane, patrz instrukcje w kolejnym punkcie na temat zmiany
ustawień gazowych.
W przypadku butli z gazem płynnym (butli gazowej) należy zastosować
regulator ciśnienia zgodny z obowiązującymi normami krajowymi.
Należy stosować wyłącznie rury, podkładki i uszczelki, które są zgodne z
obowiązującymi normami krajowymi.
W niektórych modelach, na wyposażeniu urządzenia znajduje się
łącznik stożkowy, przeznaczony do zamontowania na terenie krajów, w
których ten typ łącznika jest obligatoryjny; na rysunku 8 pokazano w jaki
sposób rozróżnić poszczególne typy łącznika (CY = cylindryczny, CO =
stożkowy). W każdym przypadku, cylindryczna część łącznika musi być
podłączona do płyty gazowej.
W przypadku podłączania płyty do gazu przy użyciu przewodów
elastycznych, należy zapewnić, aby maksymalna odległość łączenia tym
przewodem nie przekroczyła 2 metrów.
Elastyczny przewód przyłączeniowy powinien być umieszczony w taki
sposób, żeby nie dotykał ruchomych części mebli lub innych
przedmiotów (np. szuflady) i nie przechodził przez żadne miejsca gdzie
może zostać zgnieciony/złamany lub uszkodzony w inny sposób.
Aby zapobiec ewentualnemu uszkodzeniu płyty, należy zachować
następującą kolejność podczas instalacji (rysunek 6):
2) Zacisnąć połączenie przy użyciu kluczy, pamiętając o ułożeniu
przewodów rurowych w odpowiednim położeniu.
3) Podłączyć łącznik C do domowej instalacji gazowej przy użyciu
sztywnego przewodu miedzianego lub stalowego przewodu
elastycznego.
UWAGA: sprawdzić szczelność połączeń przewodów rurowych
przy użyciu roztworu wody z mydłem. Nigdy nie należy do tego celu
używać płomienia. Należy również upewnić się, że przewód
elastyczny nie wejdzie w kontakt z ruchomą częścią szafki (np.
szufladą), oraz że jest on ułożony w sposób wykluczający jego
uszkodzenie.
Ostrzeżenie: Jeżeli w pobliżu urządzenie wyczuwalny jest gaz, należy
natychmiast odciąć dopływ gazu do urządzenia i wezwać instalatora. Nie
próbować wykrywania nieszczelności przy pomocy otwartego płomienia.
09 PL
Kabel
zasilający
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.