Camden Door Controls CI-3BX, CI-3BXL Installation Instructions

! ! ! ! ! ! ! ! !
!
CI-3BX, CI-3BXL
Installation Instructions
They provide 3 buttons, Open / Close / Stop. Switch contacts are rated 3 Amps @ 240 VAC.
The CI-3BXL has a key lockout.
INSTALLATION
The electrician installing the unit should provide a UL listed watertight hub or fitting for UL type “4” rating.
CAUTION should be taken when connecting wires in conduit housing to be sure there is ample clearance inside the box so as not to interfere with the insertion of the switches when the front cover plate is installed.
KEY LOCKOUT DECRIPTION
With the key at the 12 o’clock position, the key switch is open. Turning the key clockwise to the 3 o’clock position, changes the key switch to closed. The key is removable in either position.
1. On/Off switch – Brown Wire
2. Stop switch – Black Wire
3. Open Switch – Black Wire
4. Close Switch – Black Wire
Figure 1 - Schematic Diagram
CLOSE!
OPEN!
STOP!
ON/OFF!
1!2!3!4!4!3!2!
1!
CI-3BX and CI-3BXL Installation Instructions
!
!
! ! ! ! ! ! ! ! ! !
www.camdencontrols.com Toll Free: 1.877.226.3369
File:CI-3BXL_NF_Man_Rev2.doc Revised: October 5, 2010 Part No.: 40-82B087
5502 Timberlea Blvd., Mississauga, ON Canada L4W 2T7
Figure'2')'CI)3BX' Figure'3')'CI)3BXL'