Camden Door Controls CI-3502 Installation Instructions

0 (0)
Camden Door Controls CI-3502 Installation Instructions

I n d u s t r i a l D o o r a n d G a t e C o n t r o l s

CI-3502

Key Switches

INSTALLATION INSTRUCTIONS

1. DESCRIPTION

Camden's mortise cylinder key switch is designed to control grilles or gates where high security key access is required. Includes double gang SS faceplate, (2) SPST N/O contacts for key switch. (1) SPST N/C contact for red

emergency stop button. Surface ABS box and weather resistant gasket. Mortise cylinder (1-1/8"), keyed different & (2) keys included.

2. SPECIFICATIONS

 

3. DIMENSIONS

Contact Type

STOP Button:

 

1 x N/C SPST

 

(Emergency STOP Pushbutton)

 

Key Switch:

 

2 x N/O SPST

 

 

Contact Rating

6A@125V AC

 

 

Enclosure

NEMA 1 Surface Mount

 

 

Endurance

100,000 cycles

 

 

Mortise Cylinder

1 1/8", keyed different, (2) keys

 

 

Dimensions

5 1/8" x 5 1/8" x 2"

(130mm x 130mm x 51mm)

 

 

 

5

1

'' [130mm]

8

 

 

 

 

 

 

3

5

'' [83.5mm]

 

 

 

16

 

51 '' [130mm]

8

41516 '' [125.9mm]

2'' [51mm]