Burnham Revolution, Revolution RV3, Revolution RV4, Revolution RV5, Revolution RV6 Brochure & Specs

...
Revolution
88% High Efficiency Gas-fired Water Boiler
88%
HIGH EFFICIENCY
High Efficiency up to 88% AFUE
6 Sizes Available
62 - 190 MBH
Natural or LP Gas
Direct Vent or Induced Draft
Cast Iron Sectional Design with Diamond Pin Heat Transfer Surface
Water Boiler with Low Temperature
Return Water Capabilities
Lifetime Limited Warranty
Limited Lifetime Warranty!
17
Revolution
Burnham Revolution® High Efficiency Gas-fired Boiler
The Revolution Boiler is one of the most efficient cast iron, gas-fired boilers available. With an Annual Fuel Utilization Efficiency (AFUE) of up to 88%, the Revolution exceeds the minimum requirements for its ENERGY STAR® rating. The Revolution boiler is an advanced cast iron design concept that was developed from the ground up by U.S. Boiler Co. engineers.
Unique Boiler Design
The heart of a heat exchanger is its ability to transfer heat as efficiently as possible. The Revolution boiler uses a unique design configuration to achieve its high efficiencies. First, the flue gases pass through the heat exchanger in the traditional way. Then, as the flue gases rise above the heat exchanger, they are pulled across a secondary surface to allow for an heat transfer process to take place.
This secondary heating surface is fitted with unique diamond shaped heat transfer pins that are specifically designed to extract the maximum amount of heat possible. This design concept is only available in Burnham Revolution boilers.
Diamond Pin
Heat Transfer Surface
Easy to Install, Maintain, and Service
U.S. Boiler Co. has designed the Revolution boiler to adapt to the needs of nearly any home heating application. Besides the flexibility of either horizontal or vertical venting capabilities, there is an option to use either indoor (induced draft) or outdoor (direct vent) air for the combustion process.
The Revolution boiler is also pre-piped with a primary/secondary loop installed in the boiler. This loop provides for easy hookup to a low temperature system, and with the addition of a few simple controls, the Revolution boiler will perform well with radiant floor heating installations or other low temperature heating applications.
Also, for further ease in installation, all piping and venting connections are conveniently located at the top of the boiler.
Ultimately, the flexibility of the Revolution boiler means less time is required for the installation, maintenance, and servicing of this advanced boiler system… all resulting in savings for the homeowner.
Lifetime Limited Warranty
Revolution boilers are made with cast iron sections that are produced at Burnham Foundry, LLC in Zanesville, Ohio and are assembled and tested at U.S. Boiler Co. facilities in Lancaster, PA. The Revolution is protected with a limited lifetime warranty on the heat exchanger. Additional coverage is available by purchasing the U.S. Boiler Extended Warranty Plan which provides blanket protection on parts and labor for 5 or 10 years from the date of installation.
18
Proven stainless steel vent system that works well with high flue gas temperatures
Revolution® Boiler
All piping and venting connections on top of boiler
Built-in primary/secondary piping loop saves time and simplifies installation
The VS300 injection control and pump helps eliminate condensate and thermal shock concerns while pro­viding temperature control with system temperatures from 55° to 210°F
High strength trapezoidal legs with nylon glides make moving boilers easy and protect against potential damage to floors
2-pass cast iron heat exchanger provides AFUE’s up to 88%
Step opening gas valve and electron­ic ignition provides for smooth, quiet start-up
Stainless steel burners help ensure long-term reliability and high efficiency operation
Superior base and jacket design helps keep surface temperatures cooler
GAS BOILERS
Burnham Alliance SL
Indirect-fired Water Heaters
For an abundant supply of domestic hot water, be sure to use an Burnham Alliance SL indirect-fired water heater with every boiler application.
The Alliance SL water heaters are designed with an effective hydrastone lining that offers superior corrosion resistance and outstanding performance in a wide variety of water conditions.
Water heaters are available in five sizes and come with a unique 10/2/1 warranty – 10 years on the tank and coil, 2 years labor and 1 year on parts. An optional lifetime warranty is also available.
Made in
America
19
Ratings and Specifications
Natural Gas or LP Gas
DOE
Heating
Boiler
Model
RV3 RV4 RV5 RV6 RV7
1. Ratings shown are for installations at sea level and elevations up to 2000 feet. Ratings reduce 4% for each 1000 ft. above sea level.
2. The Revolution is designed to vent directly through the wall or roof using Burnham’s approved vent systems, and AL29-4C single wall metal pipe or PVC pipe using Burnham’s PVC air intake kit.
Input
(MBH)
62
96 130 164 190
Capacity
(MBH)
55
84 114 143 166
I = B = R
Net Rating
(MBH) AFUE (%)
48 73
99 124 144
88.0
87.6
87.4
87.2
87.0
Maximum Vent
Length
(Equiv. Ft.)
50 50 50 50 50
Maximum
Air Inlet
Length
52 52 52 52 52
®
stainless steel pipe. Inlet air can be supplied using
Gas, Water and Vent Connections
Boiler
Model
RV3 RV4 RV5 RV6 RV7
Gas Valve
Inlet
(NPT)
1/2 1/2 1/2 3/4 3/4
Water Supply
& Return
(NPT)
1-1/4 1-1/4 1-1/4 1-1/4 1-1/4
Air Inlet
Diameter
(In.)
3 3 4 4 4
Vent
Diameter
(In.)
3 3 3 3 3
Water
Capacity
(Gal.)
3.6
4.4
5.1
5.9
6.6
Approximate
Shipping
Weight
(Lbs.)
260 354 448 542 636
Dimensions
TOP VIEW FRONT VIEW
Boiler Model A B C D
RV3 24-3/4 10 5-15/16 7-1/8 RV4 28 13-1/4 7-9/16 7-1/8 RV5 31-1/4 16-1/2 9-3/16 6-7/8 RV6 34-1/2 19-3/4 10-13/16 6-7/8 RV7 37-3/4 23 12-7/16 6-7/8
www.usboiler.burnham.com
© 2010 U.S. Boiler Company, Inc. - Lancaster, PA
Phone: 1-888-432-8887
20