Burnham C4 Brochure & Specs

C3™ & C4™ SERIES
with state-of-the-art components
and controls, the C3 & C4 provide
effi cient and economical oil-fi red
hot water heating.
Cast iron absorbs and transfers
heat quickly and effi ciently while
providing unmatched durability.
Rugged
cast iron sections are
designed to extract the maxi-
mum amount of heat
which
reduces fuel consumption
and
saves you money.
Metal Push Nipples join all
cast iron sections and expand
and contract with the sections
ensuring durability. They are
impervious to petroleum-based
chemicals, which can deteriorate
gaskets used in some competi-
tors’ boilers.
The C3 & C4 Series Boilers are
designed for quick, inexpensive
servicing.
Jacket design allows entry from
both the top and side to allow
complete access for cleaning.
Burner swing door provides
easy access to the combustion
chamber for fast servicing.
Packaged and ready to
install with optional tankless
coil for domestic hot water.
Circulator is prepiped and wired
for on the spot installation.
OIL-FIRED HOT WATER
ECONOMICAL HOME HEATING
Cast Iron Dependability
Ease of Maintenance and Installation
C3 & C4 RATINGS
BOILER MODEL
(1)
C3 0.75 89 77 6 8 x 8 15 83.5
C4 1.20 140 121 6 8 x 8 15 81.7
Notes:
1. Available as a packaged water boiler only.
2. The Burner Capacity is based on oil having a heating value of 140,000 BTU/GAL.
3. DOE Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) are based on U.S. Government tests at 13.0% CO2 with No. 1 maximum smoke and -0.02 inches water column over fire draft on standard equipment package.
4. Net I=B selecting boiler. Maximum Working Pressure: 30 PSI water.
BURNER
CAPACITY
GPH (2)
DOE HEATING
CAPACITY MBH
(3)
I=B=R NET
RATINGS
MBH (4)
MINIMUMCHIMNEY REQUIREMENTS
ROUND IN
DIAMETER
RECTANGLE
IN. x IN.
HEIGHT
(FT.)
AFUE %
C3 & C4 DIMENSIONS AND STANDARD EQUIPMENT
Boiler Model A B C
C3
C4
16" 8-3/4" 6"
20" 10-3/4" 6"
Standard Equipment:
• Cast Iron Section Assembly
• Deluxe Insulated Jacket
• Burner Swing Door & Mounting Plate Beckett
• Flame Retention Burner
• Boiler Drain Valve
• Barometric Draft Regulator 14000 Volt Electric Ignitor
• Solenoid Oil Valve
• 1-1/2” Supply Connection
• Relief Valve
• Combination High Limit Circulator Relay Control
• Pressure/Temperature Gauge
• Protectorelay Control Circulator
OPTIONAL TANKLESS HEATERS
OPTIONAL TANKLESS HEATERS
BOILER MODEL
C3 V1-2
C4 V1-1
Notes:
1. Tankless heater rating G.P.M. based on 100°F rise with 40°F inlet water (intermittent draw) with boiler water temperature of 200° F.
Other Optional Equipment:
Two stage fuel unit
HEATER
MODEL
HEATER GPM
OUTPUT (1)
3.25
3.5
LIFETIME LIMITED WARRANTY
Every C3 & C4 cast iron heat exchanger is covered by Burnham's Lifetime True Blue Limited Warranty.
Form No. PL81401271001-6/05-.3Mw
Printed in the U.S.A.
©2005 U.S. Boiler Company, Inc. - Lancaster,PA
Phone: 717-397-4701
www.burnham.com