Burkert 0331 User Manual

Operating Instructions Type 0330/0331
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only
Design:
2-way solenoid valve, direct acting, normally closed (Circuit func­tion A), normally open (Circuit function B).
3-way solenoid valve, direct acting, normally closed (Circuit func­tion C), normally open (Circuit function D), mixer function (Circuit function E) or diverter function (Circuit function F).
Seal Materials and Fluids handled:
See Table1.
Max. Ambient Temperature 104 °F (40 °C) Max. Fluid Temperature 194 °F (90 °C)
For Hazardous Locations Div. 2 and Ordinary Locations:
See Table1.
Pressure Range:
Maximum inlet pressure see label on valve.
Type 0330: PTFE tape is recommended for sealing ports. Mounting is accomplished by means of four M4 x 8 mm tapped holes located on the valve underside.
Type 0331: Ports A (B) are coded on side of body. For common pressure, align "A(B)" markings on valve and manifold. Valve ope­ration C an D valves can be mounted on the same manifold but the manual override buttons will point in opposite directions. To remove valve from manifold loosen only the two unsealed screws. Manifolds can be connected together with nipples. Blanking plugs, Order No. 0315-1016, should be screwed into the unused ports. Manifolds can be fixed in position using M5 screws.
Marking (example):
Body Material
BR = Brass SS = Stainless Steel
Seal Material
EPDM = EPDM NBR = NBR FKM = FKM
Circuit Function
A = 2-way - Normally Closed B = 2-way - Normally Open C = 3-way - Normally Closed D = 3-way - Normally Open E = Mixer Function F = Diverter Function
Recorder No.
Voltage / Frequency / Power Consumption
Manual override:
The manual override can be retained in position if, after depressing the button, it is turned in a clockwise direction.
Assembly instructions:
The conduit connector on the coil (4) must be supported against torque during the assembly using appropriate tools (1) (i.e. pliers, gripper...) (for example a gripper). While tightening for example a fitting (3) into the conduit connec­tor attention must be paid to the fact that a max. torque of 20Nm (177lbf in) is not exceeded.
Seal materials
Fluid Temperatures [°F] NBR EPDM FKM
Air
Water
Neutral gas
Light oil
LP-gas
Operating Instructions 1103/13_EU-EN_00893144
Fluid Ambient
Fluid Ambient
Fluid Ambient
Fluid Ambient
Fluid Ambient
+ 32 to + 176 + 32 to + 131
+ 41 to + 176 + 32 to + 131
+ 32 to + 176 + 32 to + 131
+ 32 to + 140 + 32 to + 131
+ 32 to + 140 + 32 to + 131
Maximum Pressure
Approvals
The valve is FM/CSA approved as Explosion Proof valve for Hazardous Locations Class I, Division 1, Group A, B, C, D Class II, Division 1, Group E, F, G Class III, Division 1 and 2 Operating Temperature T 4
or FM approved as Nonincendive for Hazardous Locations Class I, Division 2, Group A, B, C, D Class II, Division 2, Group F, G Class III, Division 1 and 2 Operating Temperature T 4A CSA approved for Ordinary Locations UL Recognized and UL Listed for General Purpose and Fire Protection Services.
See label on the valve.
- 22 to + 194 + 14 to + 131
+ 41 to + 194 + 14 to + 131
- 22 to + 194 + 14 to + 131
+ 32 to + 194 + 32 to + 131
+ 41 to + 194 + 32 to + 131
+ 32 to + 194 + 32 to + 131
+ 32 to + 140 + 32 to + 131
+ 32 to + 140 + 32 to + 131
Operating Instructions
Bürkert Company Locations
Wiring Diagram
Electrical Connection Type 2509
Power*
Ground (green dot)
Power*
* Orientation is not important
Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label. Voltage tolerance is ± 10 %. Available Electrical Connections see “Marking”. Wiring diagram see above.
For this product to be considered UL-listed and CSA approved for General Purpose and FM approved for Hazardous Locations Division 2, it must be in conjunction with the type 2509 cable plug connector (Electrically Operated Valves Parts, YSYI2). The connector and gasket must be assembled to the valve with the screw provided after the connection of the wire leads. This valve and connector assembly is delivered together and is to be used as one unit.
For valves to be used in Intrinsically Safe Applications the positive pole is identified by a “+” on the pin or wire No. 1 has to be con­nected to the “+”. See Control Drawing for the Rules of Interconnection.
Warning:
All valves to be used in Intrinsically Safe Applications must be clearly marked as Intrinsically Safe Apparatus.
Trouble-Shooting:
Check port connections, minimum operating pressure differential if required and supply voltage. Ensure pilot hole in piston is clear and pilot bore in the valve outlet is not abstracted. If core does not pull in, check for short circuit, coil burn-out or foreign matter im­peding core movement. A jammed or missing core causes the coil to overheat in the case of AC supply.
Warning:
These products are designed to operate in a wide variety of ap­plications, it is the user’s responsibility to select a model that is appropriate for the application. This product is designed to be installed only by suitably qualified and trained personnel. Specifications should not be exceeded under any circumstances.
The torque for the terminal screw on type 2509 is 0,5 Nm (4,4 lbf-in.).
Germany
Contact address:
Bürkert Fluid Control Systems Sales Center Chr.-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940 - 10 91 111 Fax + 49 (0) 7940 - 10 91 448 E-mail: info@de.buerkert.com
International
Contact addresses can be found on the Internet at:
Changes made to this product will render any applicable warranty null and avoid.
Specifications subject to change without notice.
Any questions? Please call Bürkert Contromatic Technical Service at (949) 223 31 00.
www.burkert.com