BTL VAC
USER'S MANUAL
Before You Start
This manual has been written for the owners and operators of
the vacuum unit BTL vac. It contains general instructions on
operation, precautionary practices and maintenance. While we
would like you to start using your equipment right away, we
encourage a thorough reading of this manual in order to fully
understand the operational features of your product.
All of us at BTL wish you every success with this product. We
pride ourselves on being as responsive as possible to our
customer’s needs. Your suggestions and comments are always
welcome since we believe an ongoing relationship with our
customers is critically important to our future product line.
Please call us or email us your suggestions.
Please remember to complete the warranty registration form
printed in this manual. The warranty form should be returned to
us no later than 30 days following installation of your equipment
to initiate warranty protection.
Again, thanks for being a BTL customer. In the event of a
problem, or if you require service, please make an initial call to
your local distributor, who will decide whether to refer the
problem to our office.
page 2 of 17
BTL VAC
USER'S MANUAL
CONTENTS
GENERAL CHARACTERISTICS........................................................................................................................4
1
2 INSTRUCTIONS FOR USE.................................................................................................................................5
2.1 Front View......................................................................................................................................................5
2.2 Rear View ......................................................................................................................................................6
2.3 Assembly and Putting into Operation.............................................................................................................7
2.4 Interconnection with Electrotherapy Devices .................................................................................................8
2.4.1 Connecting BTL vac to BTL-5000 ............................................................................................................8
2.4.2 Connecting BTL vac to BTL-06 ................................................................................................................8
2.4.3 Connecting BTL vac to Other Electrotherapy Devices..............................................................................8
2.5 Operation .......................................................................................................................................................8
2.5.1 Suction Cup Electrodes ............................................................................................................................ 9
2.5.2 Water Container .......................................................................................................................................9
2.5.3 Changing Vacuum Pressure.....................................................................................................................9
2.5.3.1 Continuous Mode................................................................................................................................9
2.5.3.2 Pulse Modes 15, 30, 45, 60 ................................................................................................................9
2.5.3.3 Massage Programs 1, 2, 3, 4.............................................................................................................. 9
2.5.3.4 Controlling Vacuum Pressure by BTL-5000........................................................................................ 9
2.5.4 Washable Plate ........................................................................................................................................9
2.6 Accessories..................................................................................................................................................10
2.6.1 Basic Accessories .................................................................................................................................. 10
2.6.2 Optional Accessories.............................................................................................................................. 10
3 MAINTENANCE AND SAFETY ........................................................................................................................11
3.1 Safety........................................................................................................................................................... 11
3.2 Useful addresses .........................................................................................................................................13
3.3 Warranty ......................................................................................................................................................13
4 TECHNICAL PARAMETERS............................................................................................................................14
page 3 of 17
BTL VAC
USER'S MANUAL
1 GENERAL CHARACTERISTICS
The BTL vac is a vacuum unit for application of electrotherapy currents by suction cup electrodes. Adjustable vacuum
pressure ensures simple and convenient attachment of patient electrodes, especially on the parts of body hard to
reach with flat rubber electrodes. Moreover, the pulse mode provides mechanical massage of the tissue, improves
body metabolism and increases blood supply.
The BTL vac has two independent outputs and operates in both continuous and pulse mode. The unit has four predefined programs to combine various pulse frequencies, and a special program to control vacuum unit directly by the
electrotherapy unit.
page 4 of 17
BTL VAC
USER'S MANUAL
2 INSTRUCTIONS FOR USE
2.1 FRONT VIEW
12 3 4 5 6
on / off
789 101112
1 cont button to select continuous mode (indicated by the pilot light)
2 buttons 15, 30, 45, 60 to select pulse mode (15, 30, 45 or 60 pulses per minute - indicated by the pilot light)
3 vacuum knob to set vacuum pressure
4 horizontal bar graph to display changes in vacuum pressure
5 buttons 1,2,3,4 to select massage program (selection indicated by the pilot light)
6 program 5 button to control vacuum pressure by the electrotherapy unit
7 removable water container
8 channel 1 outputs for suction cups (red = anode +, white = cathode - )
9 vacuum 1 button to switch electrotherapy channel 1 from classic to vacuum electrodes (indicated by the pilot
light)
10 on / off switch (blue backlighting signals the ON status)
11 vacuum 2 button to switch electrotherapy channel 2 from classic to vacuum electrodes (indicated by the pilot
light)
12 channel 2 outputs for suction cups (red = anode +, white = cathode - )
page 5 of 17
BTL VAC
USER'S MANUAL
2.2 REAR VIEW
13 14 15 16 17
V A C * - * - * - * - 0 3 0 2
08/01
v100
13 connector for electrotherapy unit (channel 1)
14 connector for electrotherapy unit (channel 2)
15 connector for classic electrodes (channel 1)
16 connector for classic electrodes (channel 2)
17 mains switch – positions 0 / I
18 manufacture label with production number
19 type label
20 fuse box
21 mains plug
22 mains voltage switch 115 V / 230 V (on the bottom)
201918
21
22