FEATURES
Low-Boy Design —The compact low-boy, dedicated upflow
design is ideal for installation in basements where overhead space is limited.
The model 367AAN is available in 2 sizes. Each size is capable of 3 heat/airflow combinations by a simple nozzle change. Unit 036105 covers inputs of 70,000, 91,000 and 105,000 Btuh, and unit 060120 covers inputs of 119,000, 140,000 and 154,000 Btuh. This eliminates the need to stock 6 separate units.
Venting —The 367AAN has a rear flue outlet. The unit may be
vented using Type L vent material and a factory-approved or masonry chimney. It may also be sidewall vented with an approved power venter.
Combustion Chamber/Heat Exchanger —The unique combi-
nation combustion chamber/heat exchanger is made mainly of stainless and aluminized steel for durability and long life. Its heat transfer properties make it highly efficient. All seams are tightly welded for leak-free operation.
Warranties —Limited Lifetime Warranty on combustion
chamber/heat exchanger. Five-year Warranty on Beckett burner. Two-year Warranty on Honeywell ignition control. Contact your dealer for details.
Beckett Oil Burner and Honeywell Controls —High quality
Beckett oil burner allows safe and efficient combustion of oil. Honeywell ignition control and fan timer board provide for reliable operation and easy connection of thermostat and accessory wiring.
Casing —Made of 18 gage painted steel for years of durability.
LOW-BOY
OIL FURNACE
The model 367AAN combines high efficiency and quiet operation with the latest in oil heating technology. The 367AAN is available in 2 sizes. Each size allows for 3 possible input capacities by a simple nozzle change. The furnace design is a low-boy style for upflow applications, especially where space is limited. The components of the 367AAN are the best available. The 367AAN features a Beckett oil burner and a Honeywell ignition control and fan timer board. The 367AAN is among the most efficient and quietest oil furnaces available and will provide years of quality service. As with other Bryant furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning.
The cabinet features an insulated enclosure for the burner and controls.
Insulation and Soundproofing —A unique silencer along with
insulated walls and rubber blower mounts efficiently controls combustion noise and vibrations and makes this unit 1 of the quietest on the market.
Adjustable Blower Speed —Four-speed blower for precise
airflow selection of heating or cooling operation.
Constant Low-Speed Blower Switch —Allows continual low-
speed air circulation through the home to maximize comfort while maintaining efficiency. Air is constantly filtered and stagnant air is reduced.
Certifications —The 367AAN is UL and ULC certified. The
efficiency rating is GAMA certified.
Form No. PDS 367A.105.2
VENT  CONN
21 1⁄4
20"20"20"
10"
3"
D
C
A
E
B
DIMENSIONS (In.)
UNIT SIZE
036105 21-1/4 53-3/4 31-1/2 26-1/2 20 20 5 060120 21-1/4 60-5/32 34-3/4 28-11/32 22 24 6
UNIT DIMENSIONS
ABCDE
FLUE
HEIGHT
RETURN
OPENING
SUPPLY
OPENING
ama
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
UNIT APPLICATION LOW-BOY
SIDES Furnace 1
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1
BACK Service Clearance 19 TOP
BOTTOM* 0 FLUE PIPE Horizontally or Below Pipe 4
FRONT 8
* Floor may be combustible.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
Furnace Casing or Plenum 2 Horizontal Warm-Air Duct Within 6 ft of Furnace 2
Vertically Above Pipe 9