design is ideal for installation in basements where overhead
space is limited.
The model 367AAN is available in 2 sizes. Each size is
capable of 3 heat/airflow combinations by a simple nozzle
change. Unit 036105 covers inputs of 70,000, 91,000 and
105,000 Btuh, and unit 060120 covers inputs of 119,000,
140,000 and 154,000 Btuh. This eliminates the need to stock 6
separate units.
Venting —The 367AAN has a rear flue outlet. The unit may be
vented using Type L vent material and a factory-approved or
masonry chimney. It may also be sidewall vented with an
approved power venter.
nation combustion chamber/heat exchanger is made mainly of
stainless and aluminized steel for durability and long life. Its
heat transfer properties make it highly efficient. All seams are
tightly welded for leak-free operation.
Warranties —Limited Lifetime Warranty on combustion
chamber/heat exchanger. Five-year Warranty on Beckett
burner. Two-year Warranty on Honeywell ignition control.
Contact your dealer for details.
Beckett Oil Burner and Honeywell Controls —High quality
Beckett oil burner allows safe and efficient combustion of oil.
Honeywell ignition control and fan timer board provide for
reliable operation and easy connection of thermostat and
accessory wiring.
Casing —Made of 18 gage painted steel for years of durability.
LOW-BOY
OIL FURNACE
The model 367AAN combines high efficiency and quiet
operation with the latest in oil heating technology. The
367AAN is available in 2 sizes. Each size allows for 3 possible
input capacities by a simple nozzle change. The furnace
design is a low-boy style for upflow applications, especially
where space is limited. The components of the 367AAN are
the best available. The 367AAN features a Beckett oil burner
and a Honeywell ignition control and fan timer board. The
367AAN is among the most efficient and quietest oil furnaces
available and will provide years of quality service. As with
other Bryant furnaces, this model is designed to work as part
of a total home comfort system which includes elements for
cooling, air cleaning, humidification, ventilation, and zoning.
The cabinet features an insulated enclosure for the burner and
controls.
Insulation and Soundproofing —A unique silencer along with
insulated walls and rubber blower mounts efficiently controls
combustion noise and vibrations and makes this unit 1 of the
quietest on the market.
Adjustable Blower Speed —Four-speed blower for precise
airflow selection of heating or cooling operation.
Unit Volts—Hertz—Phase115—60—1
Operating Voltage Range Min—Max†104—132
Maximum Unit Amps12.2
Minimum Wire Size (AWG)14
Maximum Wire Length (Ft)‡26
Maximum Fuse or Ckt Bkr Amps**15
Transformer (24v)40va
External ControlHeating40va
Power AvailableCooling30va
Air Conditioning Blower RelayStandard
BURNER AND CONTROLS
Burner Model (3450 RPM)***Beckett AFG-F3
Oil Pump Stages1
Ignition ControlContinuous
Heating Blower Control (Off Delay)Selectable 60, 90, 120, or 150 Sec
BLOWER DATA
Direct-Drive Motor HP (PSC)1/3
Motor Full Load Amps6.2
RPM (Nominal)—Speeds1075—4
Blower Wheel Diameter X Width (In.)10 X 8
Filter Size (In.)—Disposable(2) 12 X 20 X 1
FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS
Electronic Air CleanerAIRA
Mechanical Air Cleaner902B
Air Cleaner CabinetKEACA
HumidifierModel 912D, 912E, 913B, 913C, or 914A
Heat Recovery VentilatorModel VA3B, VB5B, or VC5B
Energy Recovery VentilatorModel VL3A
Thermostat—Non-ProgrammableFor Use with 1-Speed Air Conditioner—TSTATBBNAC01-A
Thermostat—ProgrammableFor Use with 1-Speed Air Conditioner—TSTATBBPAC01-A
* Capacity and AFUE in accordance with U.S. Government DOE test procedures.
† Permissible voltage limits for proper furnace operation.
‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse recommended.
*** Beckett AFG-F6 requires field supplied and replacement burner firing head.
†† For unit 036105
‡‡ For unit 060120
ICS—Isolated Combustion System
PSC—Permanent Split Capacitor
As Factory Shipped.
F55—8555—8555—8555—8555—8555—85
For Use with 2-Speed Heat Pump—TSTATBBP2S01-A or TSTATBBPDF01-A
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
• Unit Familiarization• Maintenance
• Installation Overview• Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training[ ] Classroom Service Training