Bryant 367AAN User Manual

Page 1
LOW-BOY OIL FURNACE
367AAN
Series A
FEATURES
Low-Boy Design —The compact low-boy, dedicated upflow
design is ideal for installation in basements where overhead space is limited.
The model 367AAN is available in 2 sizes. Each size is capable of 3 heat/airflow combinations by a simple nozzle change. Unit 036105 covers inputs of 70,000, 91,000 and 105,000 Btuh, and unit 060120 covers inputs of 119,000, 140,000 and 154,000 Btuh. This eliminates the need to stock 6 separate units.
Venting —The 367AAN has a rear flue outlet. The unit may be
vented using Type L vent material and a factory-approved or masonry chimney. It may also be sidewall vented with an approved power venter.
Combustion Chamber/Heat Exchanger —The unique combi-
nation combustion chamber/heat exchanger is made mainly of stainless and aluminized steel for durability and long life. Its heat transfer properties make it highly efficient. All seams are tightly welded for leak-free operation.
Warranties —Limited Lifetime Warranty on combustion
chamber/heat exchanger. Five-year Warranty on Beckett burner. Two-year Warranty on Honeywell ignition control. Contact your dealer for details.
Beckett Oil Burner and Honeywell Controls —High quality
Beckett oil burner allows safe and efficient combustion of oil. Honeywell ignition control and fan timer board provide for reliable operation and easy connection of thermostat and accessory wiring.
Casing —Made of 18 gage painted steel for years of durability.
LOW-BOY
OIL FURNACE
The model 367AAN combines high efficiency and quiet operation with the latest in oil heating technology. The 367AAN is available in 2 sizes. Each size allows for 3 possible input capacities by a simple nozzle change. The furnace design is a low-boy style for upflow applications, especially where space is limited. The components of the 367AAN are the best available. The 367AAN features a Beckett oil burner and a Honeywell ignition control and fan timer board. The 367AAN is among the most efficient and quietest oil furnaces available and will provide years of quality service. As with other Bryant furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning.
The cabinet features an insulated enclosure for the burner and controls.
Insulation and Soundproofing —A unique silencer along with
insulated walls and rubber blower mounts efficiently controls combustion noise and vibrations and makes this unit 1 of the quietest on the market.
Adjustable Blower Speed —Four-speed blower for precise
airflow selection of heating or cooling operation.
Constant Low-Speed Blower Switch —Allows continual low-
speed air circulation through the home to maximize comfort while maintaining efficiency. Air is constantly filtered and stagnant air is reduced.
Certifications —The 367AAN is UL and ULC certified. The
efficiency rating is GAMA certified.
Form No. PDS 367A.105.2
Page 2
VENT  CONN
21 1⁄4
20"20"20"
10"
3"
D
C
A
E
B
DIMENSIONS (In.)
UNIT SIZE
036105 21-1/4 53-3/4 31-1/2 26-1/2 20 20 5 060120 21-1/4 60-5/32 34-3/4 28-11/32 22 24 6
UNIT DIMENSIONS
ABCDE
FLUE
HEIGHT
RETURN
OPENING
SUPPLY
OPENING
ama
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
UNIT APPLICATION LOW-BOY
SIDES Furnace 1
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1
BACK Service Clearance 19 TOP
BOTTOM* 0 FLUE PIPE Horizontally or Below Pipe 4
FRONT 8
* Floor may be combustible.
NOTE: Adequate service clearance should be provided over and above these dimensions as required.
Furnace Casing or Plenum 2 Horizontal Warm-Air Duct Within 6 ft of Furnace 2
Vertically Above Pipe 9
A98009
VENT
CONNWidth Depth Height
—2—
Page 3
°
SPECIFICATIONS
UNIT SIZE
SHIPPING WEIGHT (Lb) 235 260
RATINGS AND PERFORMANCE
Input Btuh 70,000 91,000 105,000 119,000 140,000 154,000 Output Capacity* Nonweatherized ICS 57,000 74,000 Nozzle—100 psig Pump Pressure 0.50—70W 0.65—70W Firing Rate (GPH) 0.50 0.65 AFUE%* Nonweatherized ICS 81.4 81.4 Certified Temperature Rise Range Recommended Heating Blower Speed Med-Low Med-High Heating CFM @ 0.2-in. wc Static Pressure 840 1130 Cooling CFM @ 0.5-in. wc Static Pressure 1250 1250
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1 Operating Voltage Range Min—Max† 104—132 Maximum Unit Amps 12.2 Minimum Wire Size (AWG) 14 Maximum Wire Length (Ft)‡ 26 Maximum Fuse or Ckt Bkr Amps** 15 Transformer (24v) 40va External Control Heating 40va Power Available Cooling 30va Air Conditioning Blower Relay Standard
BURNER AND CONTROLS
Burner Model (3450 RPM)*** Beckett AFG-F3 Oil Pump Stages 1
Ignition Control Continuous Heating Blower Control (Off Delay) Selectable 60, 90, 120, or 150 Sec
BLOWER DATA
Direct-Drive Motor HP (PSC) 1/3 Motor Full Load Amps 6.2 RPM (Nominal)—Speeds 1075—4 Blower Wheel Diameter X Width (In.) 10 X 8 Filter Size (In.)—Disposable (2) 12 X 20 X 1
FACTORY-AUTHORIZED AND LISTED, DEALER-INSTALLED OPTIONS
Electronic Air Cleaner AIRA Mechanical Air Cleaner 902B Air Cleaner Cabinet KEACA Humidifier Model 912D, 912E, 913B, 913C, or 914A Heat Recovery Ventilator Model VA3B, VB5B, or VC5B Energy Recovery Ventilator Model VL3A Thermostat—Non-Programmable For Use with 1-Speed Air Conditioner—TSTATBBNAC01-A
Thermostat—Programmable For Use with 1-Speed Air Conditioner—TSTATBBPAC01-A
Zoning—2-Zone ZONEKIT2ZBDP, ZONEBB2KIT01 Zoning—4-Zone ZONEBB4KIT01 Zoning—8-Zone ZONEBB8KIT01 OIL NOZZLE KIT†† (QTY-50) 0.50 GPH For 70,000 Btuh — KLANZ0150050 OIL NOZZLE KIT†† (QTY-50) 0.65 GPH For 91,000 Btuh — KLANZ0250065 OIL NOZZLE KIT†† (QTY-50) 0.75 GPH For 105,000 Btuh — KLANZ0350075 OIL NOZZLE KIT‡‡ (QTY-50) 0.85 GPH For 120,000 Btuh — KLANZ0450085 OIL NOZZLE KIT‡‡ (QTY-50) 1.00 GPH For 140,000 Btuh — KLANZ0550100 OIL NOZZLE KIT‡‡(QTY-50) 1.10 GPH For 154,000 Btuh — KLANZ0650110
* Capacity and AFUE in accordance with U.S. Government DOE test procedures. † Permissible voltage limits for proper furnace operation. ‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse recommended. *** Beckett AFG-F6 requires field supplied and replacement burner firing head. †† For unit 036105 ‡‡ For unit 060120
ICS—Isolated Combustion System PSC—Permanent Split Capacitor
As Factory Shipped.
F 55—85 55—85 55—85 55—85 55—85 55—85
For Use with 2-Speed Heat Pump—TSTATBBP2S01-A or TSTATBBPDF01-A
—3—
036105 060120
85,000 98,000 115,000 125,000
0.75—70B 0.85—70B 1.00—70W 1.10—70W
0.75 0.85 1.00 1.10
81.4 80.6 80.6 80.6
High Med-Low Med-High High 1425 1220 1555 1890 1250 1865 1865 1865
15.7
20
Beckett AFG-F3
3/4
9.5
12 X 10
(2) 16 X 20 X 1
For Use with 2-Speed Air Conditioner—TSTATBBN2S01-A
For Use with 2-Speed Heat Pump—TSTATBBN2S01-A
For Use with 2-Speed Air Conditioner—TSTATBBP2S01-A
For Use with 1-Speed Heat Pump—TSTATBBPDF01-A
Beckett
AFG-F6
Page 4
UNIT
SIZE
036105
060120
AIR DELIVERY—CFM (With Filter)
BLOWER
SPEED
High 1425 1350 1305 1250 1170 1030 925 805
Med-High 1130 1045 1000 950 885 820 745 670
Med-Low 840 810 770 740 685 635 580 500
Low 725 730 740 745 730 715 690 665 High 2080 2040 1965 1865 1700 1575 1475 1335
Med-High 1890 1860 1770 1675 1550 1450 1330 1215
Med-Low 1555 1475 1395 1320 1210 1135 1050 940
Low 1220 1165 1080 1000 925 855 780 655
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
EXTERNAL STATIC PRESSURE IN. WC
SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book.  Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. 
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training [ ] Classroom Service Training
A94328
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 367A.105.1B
© 1998 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46206 PRINTED IN U.S.A. Catalog No. 5236-700 1-98
—4—