MODEL 361AAN UPFLOW-HORIZONTAL OIL FURNACE
The 361AAN Furnace is designed for top performance to provide years of reli­able, comfortable home heating.
The 361AAN is an upflow/horizontal oil furnace that can be installed upflow, hor­izontal right, or horizontal left for greater application coverage. The flue exits the front of the furnace. The heat exchanger is bac ked b y a Limited Lifetime W arranty.
FEA TURES
INSTALLATION FLEXIBILITY —The 361AAN installs in upflow, horizontal right,
or horizontal left positions for greater application coverage and installation flexi­bility.
HEA T EXCHANGER —The stainless steel primary and aluminized steel second-
ary heat exchangers are designed for outstanding reliability backed by a Limited Lifetime Warranty. The heat exchanger utilizes crimped seams instead of welds for corrosion resistance. All internal surfaces are accessible for any field mainte­nance without removing the heat exchanger.
CLEANOUT PORTS —Allow easy cleaning of secondary heat exchanger tubes
without disassembly of the furnace or heat exchanger.
CONTROLS —The Beckett oil burner is equipped with an electronic primary relay
for added reliability. Integrated fan timer control board with low-voltage terminal strip and 40-va transformer make air conditioning installation easy.
HEA VY DUTY BLO WER —Blower motors are PSC type and 3 speed. The direct-
drive blowers eliminate belt adjustments in the field. The constant low-speed blower switch provides air circulation during “off” cycles for indoor air filtration.
DURABLE CABINET —The casing is constructed of prepainted steel for years of
attractiveness. Filter and filter rack are provided with each furnace.
A93211
SPECIFICATIONS
UNIT SIZE 036075 036105 048125 060155
RATINGS AND PERFORMANCE
Firing Rate 0.50 0.76 0.90 1.12 Input (Btuh) 72,000 105,000 125,000 154,000 Heating Capacity (Btuh)* 55,000 85,000 100,000 125,000 AFUE %* ICS 80.0 80.7 81.5 80.3 Oil Pump Stages 1 Heating T emperature Rise Recommended Heating Blower Speed Low Medium Medium High Cooling CFM @ 0.5-in. wc Static Pressure 1255 1365 1745 1935 Heating CFM @ 0.2-in. wc Static Pressure 850 1425 1645 2170
ELECTRICAL
Unit Volts—Hertz—Phase 115—60—1 Operating V oltage Range† 104—127 Rated Load Amps 12.55 12.55 15.65 16.15 Minimum Ampacity for Wire Sizing 14 14 18 19 Minimum Wire Size AWG 14 14 12 12 Maximum Wire Length (Ft)‡ 26 26 32 30 Maximum Fuse Size (Amps)** 15 15 20 20 Control T ransf ormer (24v) 40va External Control Power Available Heating 35va
Burner Model (3450 RPM) Beckett AFG
BLOWER DATA
Motor HP 1/3 1/3 1/2 3/4 Blower Wheel Size (In.) 10 x 9 10 x 9 12 x 9 12 x 12 Blower Motor Speed and Type 1075 PSC Direct Filter Quantity and Size (1) 20-1/8 x 25 x 1 (1) 20-1/8 x 30 x 1
* Capacity and AFUE in accordance with U.S. Government DOE test procedures. † Permissible limits of the voltage range at which the unit will operate satisfactorily. ‡ Length shown is measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.
** Time-delay fuse is recommended. ICS—Isolated Combustion System
F 55—85
Cooling 35va
—2—
DIMENSIONS—MODEL 361AAN
M
SIDE RETURN AIR DUCT
SIDE RETURN AIR DUCT
L
F
A
D
J
N P
E
1
CLEANOUT PORTS
C
21 9⁄16
END RETURN
AIR DUCT
B
ALTERNATE OIL INLET THROUGH SLOTS
3 1⁄16
2
13 9⁄16
12 1⁄16
4
29⁄16
11 15⁄16
KNOCK-OUT BOTH SIDES FOR SIDE FLUE
B
E
OIL INLET 7/8-IN. DIA (2 PLACES) BOTH SIDES
H
K
ELECTRICAL CONNECTIONS
1
(TOP)
/2-IN. DIA
BOTH SIDES
7
(BOTTOM)
/8-IN.
DIA BOTH SIDES
G
1
1
A96306
DIMENSIONS (In.)
UNIT SIZE
SHIP.
WT (Lb)
UNIT DIMENSIONS
DUCT SUPPLY
OPENING
ABCDE F GHJKLMNP
FLUE
DIAMETER
SIDE RETURN
OPENING*
036075 215 22 30-1/2 48 20 17 6‡ 15 25-1/4 20-1/8 17-1/16 18-1/4 25-1/4 20-1/4 25-1/4 036105 228 22 30-1/2 48 20 17 6‡ 15 25-1/4 20-1/8 17-1/16 18-1/4 25-1/4 20-1/4 25-1/4 048125 254 22 35-1/2 48 20 22 6‡ 15 30-1/4 20-1/8 22-1/16 18-1/4 30-1/4 20-1/4 30-1/4 060155 265 22 35-1/2 48 20 22 6 15 30-1/4 20-1/8 22-1/16 18-1/4 30-1/4 20-1/4 30-1/4
* Filter rack provides transition from duct size to opening size. † Duct sizes are ID dimensions for slipping over filter rack. ‡ Outlet of heat exchanger and elbow shipped with furnace is 6 in. Flue pipe may be reduced to 5-in. diameter for vent sizing.
END (BOTTOM)
RETURN
OPENING
SIDE RETURN
DUCT SIZE†
END (BOTTOM) RETURN DUCT
SIZE†WIDTH DEPTH HEIGHT
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (In.)
UNIT APPLICATION UPFLOW HORIZONTAL
SIDES—Furnace 02
Supply Plenum and Warm-Air Duct Within 6 ft of Furnace 1 1 BACK 00 TOP—Furnace Casing or Plenum 2 2
Horizontal Warm-Air Duct Within 6 ft of Furnace 2 3 BOTTOM 0* 0* FLUE PIPE—Horizontally or Below Pipe 4 4
Vertically Above Pipe 8 8
FRONT 824
* Floor may be combustible.
AIR DELIVERY—CFM (Without Filters)
UNIT SIZE
BLOWER
MOTOR
HP SPEED
036075 1/3 PSC
036105 1/3 PSC
048125 1/2 PSC
060155 3/4 PSC
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
High 1530 1475 1410 1340 1255 1170 1075 970 855 705
Medium 1240 1200 1150 1110 1065 1000 920 830 705 555
Low 870 850 830 805 765 720 660 590 480 360
High 1635 1560 1500 1425 1365 1260 1165 1040 945 785
Medium 1470 1425 1365 1290 1220 1140 1030 935 825 695
Low 1280 1245 1205 1145 1085 1010 935 835 710 590
High 1965 1915 1865 1805 1745 1665 1590 1515 1445 1345
Medium 1695 1645 1615 1565 1530 1465 1410 1335 1255 1165
Low 1340 1330 1320 1290 1270 1215 1180 1125 1045 990
High 2240 2170 2085 1980 1935 1820 1750 1665 1590 1510
Medium 2000 1965 1890 1795 1755 1690 1625 1555 1480 1375
Low 1535 1495 1450 1420 1365 1330 1275 1205 1125 1035
EXTERNAL STATIC PRESSURE IN. WC