Please read this instruction manual carefully before installing and operating the instrument.
Not following the guidelines could result in personal injury and/or damage to the equipment.
Head Office: Nijverheidsstraat 1a, NL-7261 AK Ruurlo, The Netherlands, Tel. +31 573 458800, info@bronkhorst.com
BRONKHORST®
Disclaimer
Even though care has been taken in the preparation and publication of the contents of this manual, we do not assume
legal or other liability for any inaccuracy, mistake, mis-statement or any other error of whatsoever nature contained
herein. The material in this manual is for information purposes only, and is subject to change without notice.
Bronkhorst High-Tech B.V.
May 2011
Symbols
Important information. Discarding this information could cause injuries to people or damage to the
Instrument or installation.
Helpful information. This information will facilitate the use of this instrument.
Additional info available on the internet or from your local sales representative.
Page 2 FlowDDE 9.17.067
BRONKHORST®
Table of contents
1 GENERAL PRODUCT INFORMATION ................................................................................................. 4
1.2 REFERENCES TO OTHER APPLICABLE DOCUMENTS ..................................................................................................... 4
1.2.1 Manuals and user guides ............................................................................................................................ 4
1.4 SYSTEM REQUIREMENTS..................................................................................................................................... 5
1.5 INSTALLATION AND START UP .............................................................................................................................. 5
1.5.1 Start up options ........................................................................................................................................... 5
4.1 BASIC: COMMUNICATION TO INSTRUMENTS AND SERVING CLIENT APPLICATIONS ............................................................10
4.1.1 Communication settings ........................................................................................................................... 10
4.1.2 Open communication ................................................................................................................................ 11
4.1.3 Close communication ................................................................................................................................ 11
4.3.1 Poll time .................................................................................................................................................... 12
4.3.2 System settings ......................................................................................................................................... 12
4.4 VIEW AND EDIT PARAMETERS .............................................................................................................................13
4.4.1 View parameters and values ..................................................................................................................... 13
4.5 TEST COMMUNICATION ....................................................................................................................................14
4.5.1 Test FLOW-BUS and DDE ........................................................................................................................... 14
4.5.2 Test ProPar ................................................................................................................................................ 15
4.6 SERVICE LOG ..................................................................................................................................................15
5 DDE COMMUNICATION BY CLIENTS ............................................................................................... 16
5.1 BASIC PARAMETER COMMUNICATION ..................................................................................................................16
5.2 SPECIAL OPTIONS ............................................................................................................................................16
5.2.3 Server topic ............................................................................................................................................... 17
7 SERVICE ........................................................................................................................................ 19
Page 3 FlowDDE 9.17.067
BRONKHORST®
1 GENERAL PRODUCT INFORMATION
1.1 INTRODUCTION
This manual will explain the operation of the software tool FlowDDE. It has been written based on FlowDDE V4.67, but
should be suited for former (and future) versions as well, although functionality may differ from what is described.
FlowDDE is a Dynamic Data Exchange (DDE) server, an easy connection between Windows applications and digital
Bronkhorst
By using DDE commands, sent by software to FlowDDE, data can be sent to or requested from digital instruments.
FlowDDE handles all communication to the instruments and provides the data to applications.
Examples of applications with DDE communication are Microsoft Excel and LabVIEW (National Instruments). Several
Bronkhorst applications require FlowDDE for communication to the instrument(s), e.g. FlowPlot and FlowView.
1)
Bronkhorst: This includes Bronkhorst High-Tech B.V. , Bronkhorst Cori-Tech B.V. and M+W Instruments GmbH.
1.2 REFERENCES TO OTHER APPLICABLE DOCUMENTS
Manuals and guides for digital instruments are modular. General instructions give information about the functioning
and installation of instruments. Operational instructions explain the use of the digital instruments features and
parameters. Fieldbus specific information explains the installation and use of the fieldbus installed on the instrument.
1)
instruments. DDE provides a basic level of interprocess communication between Windows applications.
1.2.1 Manuals and user guides
Operation instructions digital instruments (document nr. 9.17.023)
FLOW-BUS interface (document nr. 9.17.024)
Profibus-DP interface (document nr. 9.17.025)
DeviceNet interface (document nr. 9.17.026)
Modbus slave interface (document nr. 9.17.035)
RS232 interface with FLOW-BUS protocol (document nr. 9.17.027)
1.2.2 Technical drawings
Hook-up diagram laboratory-style MBC RS232 + analog (document nr. 9.16.062)
Hook-up diagram industrial style MBC RS232 + analog (document nr. 9.16.051)
Hook-up diagram CORI-FLOW RS232 + analog (document nr. 9.16.044)
Hook-up diagram LIQUI-FLOW L30 digital RS232 + analog (document nr. 9.16.073)
1.2.3 Software tooling
FlowPlot (document nr. 9.17.030)
All these documents can be found at:
http://www.bronkhorst.com/en/downloads
1.3 SUPPORTED INSTRUMENTS
All FLOW-BUS instruments and instruments with RS232 communication, with the following limitations:
• RS232/FLOW-BUS interface: 16-bit is not supported and 32-bit firmware >= 4.09 only
• Digital mass flow meters/controllers without RS232 communication: firmware >= V5.xx only
• Digital readout control modules (E-7000): firmware >= V3.xx only
Page 4 FlowDDE 9.17.067
BRONKHORST®
Processor
x86 or x64 700 MHz or higher
Memory (RAM)
64 MB
Hard disk
20 MB available disk space
Display
800 x 600 or higher resolution, 256 colors or more
Connections
RS232 port with FIFO buffers
Operating system
Windows 2000, XP, Vista (x86 or x64) or 7 (x86 or x64)
The digit grouping symbol of currency must always differ from the number’s decimal symbol. Having
other problems as well. See Microsoft’s KB198098.
1.4 SYSTEM REQUIREMENTS
equal symbols is not valid (not just in this situation, but also in other situations) and will probably cause
To avoid communication errors, it is advised to use a serial (RS232) port with hardware buffer overrun
detection. Few USB-RS232 converters have this feature, but e.g. the Digitus part no. DA-70156 has.
1.5 INSTALLATION AND START UP
Follow on-screen instructions when installing FlowDDE.
FlowDDE will be installed in C:\Program Files\Bronkhorst\FlowDDE32.
Start FlowDDE through the Start menu: Start >> (All) Programs >> Bronkhorst >> FlowDDE V4.67.
C:\Program Files is a system folder and is followed by (x86) on 64-bit Windows versions and may differ
on non-English Windows versions.
1.5.1 Start up options
In some situations, it is convenient that FlowDDE behaves differently or performs an action after startup. The
following start up options are available:
• FlowDDE /o open communication to FLOW-BUS
• FlowDDE /s start simulation mode
• FlowDDE /d accept all FLOW-BUS configuration changes on open communication
• FlowDDE /q disable pop up message boxes
• FlowDDE C:\client.exe start the client application C:\client.exe (usually in combination with /o)
Page 5 FlowDDE 9.17.067
BRONKHORST®
Pin number
Description
1
9
not connected
Shield
2 INTERFACES
2.1 RS232/FLOW-BUS INTERFACE
The RS232/FLOW-BUS interface is an interface between the FLOW-BUS and the RS232 V24 serial (computer) port. It
will either be supplied as a separate enclosed unit with a FLOW-BUS connector and a RS232 connector or as an
integral 14TE module of your E-7000 readout and control system. The converter offers communication with a baud
rate up to 38400 baud. Communication software support is available. Communication settings are: 38400, n, 8, 1.
2.1.1 D-connector for RS232
The female RS232 (x) (sub miniature 9-pin) D-connector has the following pin configuration:
2
3
4
5
6
7
8
TXD
RXD
not connected
0 Vd
DTR
CTS
RTS
Page 6 FlowDDE 9.17.067
BRONKHORST®
FLOW
EL-FLOW
®
Select
mass flow meter/controller
Power
Supply
Instrument supplied through the D-sub DB-9 connector
FLOW
EL-FLOW
®
Select
mass flow meter/controller
DeviceNet / FLOW-BUS instrument supplied through the bus connector
FLOW
EL-FLOW
®
Select
mass flow meter/controller
Power
Supply
Profibus instrument supplied through the D-sub DB-9 connector
By default, the interface offers communication at a baud rate of 38400 baud. On instruments that offer
technical documentation of your instrument which baud rates are supported.
2.2 RS232 ON MULTIBUS INSTRUMENT
The RS232 interface on a multibus instrument can be connected to any RS232 V24 serial (computer) port. Make sure
to respect the hook-up diagram. Bronkhorst offers special cables for communication, separating the RS232 lines from
the power and analog in- and output. On the 9-pin male D-sub connector of the instrument RX and TX are available on
pin 6 and pin 1.
Serial RS232 communication on a multibus instrument with RS232 can be treated as a FLOW-BUS system with one
instrument and a FLOW-BUS/RS232 interface. In case a FLOW-BUS fieldbus connection is present, other instruments
connected to the FLOW-BUS can be communicated with as well.
RS232 communication is possible by:
• 9-pin Sub D-connector (non-IP65 instruments, e.g. EL-FLOW)
• 8-pin DIN connector (IP65 instruments, e.g. CORI-FLOW)
For the exact connections please advise your hook-up diagram.
2.2.1 Applications, e.g. EL-FLOW
For proper cable installation please consult the applicable hook-up diagram mentioned in paragraph
1.2.2
the possibility to change the RS232 baud rate, the baud rate may be configured differently. See the
Page 7 FlowDDE 9.17.067
BRONKHORST®
Property description in parameter properties table
Item
Description
Parameter(DDE)
Unique parameter number (also used for DDE-communication: P(x)).
Name
Name of the parameter, used for parameter identification.
Process
Process where parameter is used on FLOW-BUS module, used for communication directly through
RS232
information (for parameters located in more than one process, e.g. setpoint, measure).
FBnr(parameter)
Parameter number in process on FLOW-BUS module, used for communication directly through
RS232.
Type
Variable type of the parameter
data types > 1 byte are MSB first.
StrLen
Length of string in bytes (characters) used in combination with Type c for strings
0 means no info required (not a string type parameter)
Min
Minimum value of parameter allowed when parameter is read/written. The value will be checked
on this limit (error when out of limit).
Max
Maximum value of parameter allowed when parameter is read/written. The value will be checked
on this limit (error when out of limit).
Read
Indication if parameter is allowed to be read via FLOW-BUS.
Write
Indication if parameter is allowed to be written via FLOW-BUS.
Poll
Indication if parameter should be polled continuously by FlowDDE in order to keep the (changing)
parameter value up to date.
Advanced
Indication if parameter is for advanced users only. These are mainly parameters for
maintenance/service.
Secured
Indication if parameter is secured for use through FLOW-BUS. Reading this parameter is possible,
but changing it needs special handling.
High security
Indication if parameter is highly secured (only few parameters). Reading this parameter is possible,
but changing it needs special handling.
Description
Short description about the meaning of parameter or where it is used for.
DDE str
Parameter DDE string (max. 10 characters). This becomes the DDE value when parameter is not
available on instrument. Also: until FlowDDE V4.58 used for parameter identification.
Changing parameter values is possible when a parameter is not read-only and not secured. The range
error'.
3 PARAMETER INFORMATION
FLOW-BUS is used for parameter value exchange between instruments and operation modules (keyboard or PCinterface). Parameter information consists of several properties for behaviour within the FLOW-BUS system. In the
‘parameter properties’ table you will find a list of parameters and their properties. In the ‘parameter values’ table, the
values are described more detailed. This list consists mostly of parameters for mode settings.
. When empty in the table, the process has to be determined from the FLOW-BUS system
• c (unsigned) char 1 byte value 0..255 when StrLen is 0
• c string Multiple bytes when StrLen is other than 0
• i (unsigned) integer 2 bytes value 0..65535
• f float 4 bytes value +-1.18E-38..+-3.39E+38 (IEEE-floating point notation)
• l (unsigned) long 4 bytes value 0..4294967295
• -2 indicates that a string is zero-terminated, not defined in length, but until the first 0-char.
• X indicates a string with a length of X bytes
•
and type of parameters are described in the tables. When parameter values are out of range they will
be either 'clipped' on the nearest value allowed or you will get an error message: 'parameter value
(FlowDDE) Parameter numbers:
All parameter information is referenced to the parameter number. This is a unique number for a parameter to avoid
redundancy. These numbers are needed for DDE communication only.
For communication with FLOW-BUS through other ways than DDE, directly via RS232 ASCII-strings or via C-libraries,
use the parameter numbers for the FLOW-BUS modules (in column FBnr of Parameter properties table). Also you will
Page 8 FlowDDE 9.17.067
BRONKHORST®
It is important to know that not all parameters are available on all (FLOW-BUS) instruments.
are available on which devices.
need to know the node address of the instrument on the FLOW-BUS, the process number and the parameter number
on the instrument.
The node address is the node address of the instrument on the FLOW-BUS. RS232 interfaces accept node address 128.
When sending messages to node address 128, the message will always be accepted, regardless the true node address
of the instrument on the bus.
The process can be found in the parameter table or has to be determined when nothing is filled in. In that case, the
process number most often is 1, but on devices with e.g. multiple sensor channels, the process will be 1 for the first
channel, 2 for the second, and so on up to 32. On these modules also process 33, 65 and 65 are multiplied in this way.
For more details about parameters and their use see also the technical documentation of your
instrument. The Bronkhorst software application FlowDDE also gives an overview of which parameters
Page 9 FlowDDE 9.17.067
BRONKHORST®
4 OPERATION
4.1 BASIC: COMMUNICATION TO INSTRUMENTS AND SERVING CLIENT APPLICATIONS
Once FlowDDE has been started, the main window will appear. It consists of a menu bar, an information line and a
messages section.
In the messages section the general procedure to start serving client applications with the FlowDDE server is described
in four steps:
1. Connect an instrument to a COM port of the PC
2. Set the communication settings
3. Start the communication
4. Wait until FlowDDE is ready
Using the information of chapter 2 and/or the hook-up diagram, physically connect the instrument to the COM port of
the PC.
4.1.1 Communication settings
Before communication to the instrument(s) can be made, the
communication settings have to be correctly configured.
Open the communication settings from the menu Communication >> Communication settings… or by pressing F2. The window shown at
the right hand side pops up.
At Interface, the COM port and the baud rate can be selected. For
most interfaces, the default baud rate is 38400.
At FLOW-BUS some settings for the FLOW-BUS interface can be set.
The default values (Auto busmaster + optimize and both process and
parameter chaining enabled) should only be changed in case these
options are not supported, i.e. only for legacy interfaces.
On OK the settings are accepted, whereas on Cancel FlowDDE retains
its settings.
In the main window, the actual communication settings are shown
below the menu bar, next to the interface status.
Page 10 FlowDDE 9.17.067
BRONKHORST®
4.1.2 Open communication
Once the communication settings are correctly configured, the communication to the instruments can be started and
instrument values can be used by client applications.
From the menu, click Communication >> Open communication or press F3. Now FlowDDE will try to make a
connection to the FLOW-BUS interface. Once a connection is established, FlowDDE will initialize the interface when
needed and scan the connected FLOW-BUS when present. When the FLOW-BUS configuration is different than the
previous configuration, FlowDDE shows a warning. To all connected instruments a channel number is assigned and for
each channel the applicable parameter DDE items are created. These parameter DDE items are to be used by client
applications.
After all DDE items are created, FlowDDE starts polling several parameters from all instruments periodically. The DDE
values of these parameters are updated after each poll, so clients don’t need to actively refresh these before using.
From now on, FlowDDE is ready for any client. FlowDDE can be minimized and acts as silently as a server until the
communication is closed.
4.1.3 Close communication
Communication to the instrument can be stopped by, from the menu, Communication >> Close communication or F4.
Polling is stopped, all DDE items are terminated and clients can no longer set or get parameter values.
Communication closes automatically when FlowDDE is closed.
4.2 CONFIGURATION
When communication is opened and FlowDDE has scanned the FLOW-BUS system, the FLOW-BUS configuration can
be viewed: FLOW-BUS >> Configuration or F5.
The following window is shown.
On the left hand side, all instruments connected to the FLOW-BUS are shown, ordered by their assigned channel. In
this example, two digital controllers (channel 1 and 2) and one RS232/FLOW-BUS interface with 4 real-time channels
(channel 3 to 6) are connected.
On the right hand side, the top frame is meant to add legacy modules to the FLOW-BUS. To add such a module,
connect the module to the FLOW-BUS, press Search and follow on-screen instructions.
Page 11 FlowDDE 9.17.067
BRONKHORST®
At Device information information about the selected channel in the list on the left hand side is shown. Node shows
the current node address of the instrument. The node address of an instrument can be changed by pressing Change
and entering the new node address. For multi-channel devices, e.g. an RS232/FLOW-BUS interface, the process of the
channel is shown at Process.
The checkbox Poll indicates that selected parameters – those marked Poll in the parameter list – from this channel are
polled by FlowDDE when the communication is open.
Any comments about the instrument can be entered in the Info field. These comments are stored between FlowDDE
sessions as long as the FLOW-BUS configuration is not changed.
The configuration window allows basic testing of a selected instrument. The Measure is polled and a Setpoint can be
written at Operation test.
4.3 SETTINGS
To optimize FlowDDE for your application or to control resources, the behaviour of FlowDDE can be configured. The
settings are divided into two categories: poll time and system settings.
4.3.1 Poll time
Parameters of which the value may change frequently are read by FlowDDE periodically.
Those parameters are marked Poll in the parameter list. How often these parameters
are polled, is determined by the poll time. The lower the poll time, the more often the
parameters are read, but the higher the CPU load becomes.
The poll time can be changed at Server >> Poll time. The window at the right hand side
pops up. It contains three settings:
• Poll time: the time between two poll requests.
• Batch of channels: the number of channels that are polled at once. The next poll time the next batch is
polled. This prevents high CPU loads due to many channels being polled, but reduces the actual poll time per
channel as the total number of channels is divided by the batch of channels.
•Real-time poll time: the poll time for the real time channels in case an RS232/FLOW-BUS interface box is
used with real-time polling enabled. This requires special configuration, used by e.g. FlowPlot.
4.3.2 System settings
Other settings than related to the poll time are available by Server >> Settings.
The basic settings are:
•Retry network access: number of times a read or write
request is retried after a failure.
•Poll parameters on initialization: after opening
communication all parameters of all devices are read,
so the initial DDE value is filled.
in parameters lists and FlowDDE windows. For normal
instrument operations, the hidden parameters are not
needed. For maintenance or service, these parameters
may be needed visible and this option can be disabled.
Although these parameters are hidden, they can still be
reached via DDE.
•Trim CRLF from received DDE value: some Windows
applications send a carriage return and line feed with
each DDE command. FlowDDE can remove them. For
binary parameters, this will not happen.
Page 12 FlowDDE 9.17.067
BRONKHORST®
•Show date, time, msec. in main window of FlowDDE for each line.
Several advanced settings are available for troubleshooting purposes. Some applications do not support enabling
these settings. If you experience problems, disable these options:
•Enable indirect polling: each FLOW-BUS instrument keeps track of which parameters are changed by itself or
any other instrument. Parameter 81 shows the process in which a parameter is changed. When this option is
enabled, FlowDDE reads parameter 81 and polls the processes that are changed, so applications don’t need
to poll the parameters themselves. Note: this option slows down communication, as much more data is read
from the FLOW-BUS.
•Enable communication to unavailable parameters: DDE items are created for parameters above number 237
when the instrument does not contain the parameter. Close and open the communication after changing this
setting.
•Ignore database restrictions: FlowDDE doesn’t generate errors based on the parameter information in its
database (see chapter 3 and 6), but reads and writes all command to the instrument. When the instrument
returns an error, that error is shown.
4.4 VIEW AND EDIT PARAMETERS
All parameters any Bronkhorst instrument can have are stored in the database of FlowDDE, which is used for correct
communication to the instruments. The contents of this database can be viewed and edited.
4.4.1 View parameters and values
The list of parameters and its properties as described in chapter 3 can be viewed by Info >> Parameter list. The
meaning of the values of several parameters, can be viewed by Info >> Parameter value list.
To view the parameters that a module (instrument) can have, open the View modules/parameters window from the
FLOW-BUS menu. Select the correct module and click the View parameters button.
4.4.2 Edit parameters
At the Parameters section, all properties of parameter can be viewed and changed. It is not advised to change
anything, but for performance improvement it can be useful to remove a parameter from the poll list or from DDE at
all. These two options are described here.
To change a property of a certain parameter,
find the correct parameter number, either by
the Select buttons or by entering its number in
the field below it and pressing Search. The
properties are shown now.
To stop FlowDDE polling the parameter in its
poll sequence, uncheck the Poll checkbox. (To
start polling a parameter, check it.) To store
the new value, change the parameter number
or close the window and answer the question
by Yes.
Removing a parameter from DDE means that
client applications cannot reach it and FlowDDE
does not read the parameter value from the
instrument. To remove a parameter from DDE,
uncheck the Available at DDE checkbox. By
default all parameters are available (checked).
Changing parameter information cannot be undone other than by reinstalling FlowDDE!
Unless you are fully aware of the effect, please do NOT make any changes!
Page 13 FlowDDE 9.17.067
BRONKHORST®
4.5 TEST COMMUNICATION
For maintenance and service operations, it is often required to read from or write to a certain parameter. FlowDDE
contains two test facilities: one to test FLOW-BUS and DDE communication and one to test lower level ProPar
communication.
4.5.1 Test FLOW-BUS and DDE
Open the FlowDDE test form from the menu FLOW-BUS >> Test FLOW-BUS and DDE or F6. The following window
appears.
The window consists of two sections. At the Test FLOW-BUS section parameters can be read and written directly to
the instrument, regardless of the DDE behaviour that a separate poll command is required to read a parameter value
and only changes are written to the instrument. The DDE value is updated on read, but not on write.
On the contrary, at the Test DDE section parameters can be read and written like any DDE client would do. Pressing
Read shows the current value at the DDE level, but the actual instrument value is not read and may be different. At
Write the value is written to the DDE level and, because of the nature of DDE, only if it is different than the previous
value, the value is written to the instrument.
At the Test DDE section links
to client applications, e.g.
Microsoft Excel, can be easily
made. Select the channel
and parameter to which a
link is to be made.
Press Copy link to copy the
link to the clipboard. In the
client application, use the
Paste Special option and
select Paste link to paste the
link (e.g. Paste Special in
Microsoft Excel, see image).
Any parameter value change
will be sent to the client
application.
The other way around is
possible as well. Copy a link
from any application (e.g.
copy a cell from Excel). In the test form, press Paste. Any change in the application’s field result in the parameter
value in FlowDDE to be updated. Note that when the communication is closed, all links will be terminated and will not
be restored when the communication is opened again.
Page 14 FlowDDE 9.17.067
BRONKHORST®
Disable standard polling temporarily stops FlowDDE from polling the selected parameters and only the read actions in
this test form (or any client) are performed on the instrument.
4.5.2 Test ProPar
For low level testing purposes, FlowDDE contains the Test Propar form, in
which individual FLOW-BUS messages may be read and written to an
instrument. This form replaces the former DLL test application.
This form can only be opened when the communication is closed by
Communication >> Test PropPar or Shift+F6. Using this form, messages can
be sent at the node/process/parameter level, so even parameters that are
not in the FlowDDE database can be read and/or written.
As soon as the Read or Write button is pressed for the first time, the
communication is opened. When the window is closed, the communication
is closed as well.
4.6 SERVICE LOG
In case of problems with your instrument(s) and you need to contact an expert (e.g. Bronkhorst Support), all
parameter values of your instrument can be logged to a file. To create such a service log, click File >> Service log or Ctrl+L and enter the file name.
Page 15 FlowDDE 9.17.067
BRONKHORST®
5 DDE COMMUNICATION BY CLIENTS
5.1 BASIC PARAMETER COMMUNICATION
Client applications communicate to the FlowDDE server by using DDE messages. Before messages can be exchanged, a
DDE link had to be made. A DDE link consists of three parts: the server, the topic and an item. For separation the
characters '|' and '!' may be used, so a DDE link in e.g. Microsoft Excel becomes Server|Topic!Item.
For standard instrument parameters and the FlowDDE server, these are:
• Server: FlowDDE or FlowDDE2
• Topic: C(X) for channel X
• Item: P(Y) for parameter Y
An example of a DDE link in a Microsoft Excel cell is =FlowDDE|’C(1)’!’P(8)’ to read parameter 8 of channel 1.
5.2 SPECIAL OPTIONS
5.2.1 Channel 0
Special commands can be sent to FlowDDE by means of the command channel 0, C(0). This channel is not related to
any FLOW-BUS instrument, but is for FlowDDE control only. Channel 0 contains P(0) , P(1) and P(2) items only.
P(0) is the command parameter. Write a number to P(0) will trigger FlowDDE to read all parameter values from one or
more channels and update the parameter values at the DDE level. To read a smaller amount of parameters, parameter
groups can be read. Which parameters are in which group can be found in the parameter list.
• C(0)!P(0) = X read values of all parameters of channel X
• C(0)!P(0) = X.Y read values of all parameters in group Y of channel X
• C(0)!P(0) = -1 read values of all parameters of all channels
Other special actions can be triggered by P(0):
• C(0)!P(0) = -2 open a log file, read all parameter values on all channels, and close the file.
• C(0)!P(0) = -3 bring the main window to the front
• C(0)!P(0) = -4 bring the FLOW-BUS configuration window to the front
• C(0)!P(0) = -6 bring the Poll time window to the front
• C(0)!P(0) = -7 bring the System settings window to the front
• C(0)!P(0) = -8 restart the communication
• C(0)!P(0) = -9 terminate FlowDDE
• C(0)!P(0) = -10 minimize FlowDDE
P(1) is the read status information channel. When FlowDDE is reading data from the FLOW-BUS, all status/error
messages will be send to this parameter. When the value of this parameter is 0, everything is OK, otherwise will
contain the status/error message.
P(2) is the write status information channel. When a client application sends data to FlowDDE and FlowDDE sends the
values to the FLOW-BUS, any status/error messages will be send to this parameter. When the value of this parameter
is 0, everything is OK, otherwise will contain the status/error message.
5.2.2 Parameter 0
Similar to the way parameter 0 of channel 0 can be used to read parameters from any channel, parameter 0 of any
channel can be used to read parameters from that channel:
• C(X)!P(0) = Y read value of parameter Y of channel X
• C(X)!P(0) = Y-Z read values of parameters Y to Z of channel X
• C(X)!P(0) = GROUPY read values of all parameters in group Y of channel X
• C(X)!P(0) = ALL read values of all parameters of channel X
Page 16 FlowDDE 9.17.067
BRONKHORST®
Any combination of the above is valid by separating the parts by a comma, e.g. C(X)!P(0) = 1-10,20,GROUP3 will read
parameters 1 to 10, 20 and all parameters in group 3 of channel X.
5.2.3 Server topic
Information about the FlowDDE server, several settings and FLOW-BUS configuration information can be obtained by
clients through the server topic.
The server topic has several items:
• Server!ProductName FlowDDE or FlowDDE2
• Server!FlowDDEVersion Version of FlowDDE
• Server!DatabaseVersion Version of FlowDDE database (FlowDDE.mdb)
• Server!FLOWBUSDLLVersion Version of Flowb32.dll
• Server!Status Status of FlowDDE
• Server!ComStatus Status of FlowDDE – Idle, Normal polling, Simulation, Scanning FLOW-BUS
• Server!OpenCom Communication status/command – 0 = close, 1 = open
• Server!MaxChan Maximum channel number in FLOW-BUS configuration
• Server!MaxNode Maximum node address in FLOW-BUS system
• Server!MaxPar Maximum parameter number in FlowDDE database
• Server!SelChan Select channel for changing polling mode – 0 = all channels
• Server!Polling Polling status/command for channel set by SelChan – 0 = dis-, -1 = enabled
• Server!PollTime Poll time interval for polled parameters (not real-time)
• Server!PollBatch Number of channels to poll
• Server!RTPInterval Poll time interval for real-time channels
• Server!InterfaceChan Channel number of instrument which communicates with FlowDDE
• Server!Interface Communication interface, e.g. COM1
• Server!Baudrate RS232 communication baud rate
Page 17 FlowDDE 9.17.067
BRONKHORST®
Included in the
FlowDDE application
DDE client
Flowb32.dll
RS232/FLOW-BUS interface
FlowDDE
DDE messages
ProPar (binary)
calls to DLL
6 FLOWDDE TECHNICAL DETAILS
In the following diagram, the communication from a DDE client to the instrument is schematically drawn. The
FlowDDE application makes use of the Flowb32.dll and the parameter database.
FlowDDE installation
parameter database
or multibus instrument
A DDE client communicates to FlowDDE using DDE messages. FlowDDE uses the parameter database for parameter
information and the Flowb32.dll to perform the low level communication to the FLOW-BUS. The Flowb32.dll has
methods to easily send or request a parameter value to a certain node, process and parameter and to get the
answers. From the calls to these methods, it constructs the required FLOW-BUS messages in the binary ProPar
protocol, sends these messages and receives and interprets the answers from the instruments.
Page 18 FlowDDE 9.17.067
BRONKHORST®
7 SERVICE
For current information on Bronkhorst and service addresses please visit our website:
Do you have any questions about our products? Our Sales Department will gladly assist you selecting the right product
for your application. Contact sales by e-mail:
For after-sales questions, our Customer Service Department is available with help and guidance. To contact CSD by email:
No matter the time zone, our experts within the Support Group are available to answer your request immediately or
ensure appropriate further action. Our experts can be reached at:
http://www.bronkhorst.com
sales@bronkhorst.com
support@bronkhorst.com
+31 573 45 88 39
Page 19 FlowDDE 9.17.067
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.