Bronkhorst E-8000 Quick Start

Quick Installation Guide
Doc nr.: 9.17.077B Date: 10-03-2015
SCOPE OF THIS GUIDE
4. Safety precautions
5. EMC requirements
6. Inserting and removing cables
Instruction Manual E-8000, Power Supply/Readout and Control system
(doc. nr. 9.17.076)
E-8000 Readout - Supply
(doc. nr. 9.16.112)
E-8000 Readout - RS232 + Supply
(doc. nr. 9.16.113)
E-8000 Readout - FLOW-BUS + Supply
(doc. nr. 9.16.114)
E-8000 CEM Controller - Analog I/O
(doc. nr. 9.16.102)
E-8000 CEM Controller - RS232
(doc. nr. 9.16.103)
E-8000 CEM Controller - FLOW-BUS
(doc. nr. 9.16.104)
E-8000 CEM Controller - PROFIBUS DP
(doc. nr. 9.16.105)
E-8000 CEM Controller - DeviceNet™
(doc. nr. 9.16.106)
E-8000 CEM Controller - Modbus
(doc. nr. 9.16.107)
E-8000 CEM Controller - EtherCAT®
(doc. nr. 9.16.108)
E-8000 CEM W-10xA/202A
(doc. nr. 9.16.109)
E-8000 CEM W-303B 230Vac
(doc. nr. 9.16.115)
E-8000 CEM W-303B 120Vac
(doc. nr. 9.16.116)
i
www
These documents can be downloaded from the website: www.bronkhorst.com or can be sent by e-mail on request.
1. Check E-8000 properties
Before installing an E-8000 system it is important to read the attached labels on the rear side of the instrument and check:
Instrument type Power supply Power Fuse Tmax Signals
2. Installation
The E-8000 is rated IP20, implying that the electronics housing and electrical connections do not offer any protection against moist environments. Make sure to create sufficient space for proper heat dissipation.
3. Power consumption
The various available configurations have a restricted power supply. Typical for Cassette and ½ 19" systems Pmax = 30W for 19" systems Pmax =2x30W. Refer to chapter 2 of the Instruction Manual (9.17.076) to calculate the power consumption of your Bronkhorst instruments and to check if the power supply is sufficient.
4. Safety Precautions
Safety precautions should be observed before using this product and any associated instrumentation. The safety precautions can be found in the E-8000 Instruction Manual (9.17.076). This document can be downloaded from the website: www.bronkhorst.com or can be sent by e-mail on request.
5. EMC requirements
All E-8000 configurations carry the CE-mark. Therefore they have to comply with the EMC requirements which are valid for this kind of equipment. However, compliance with the EMC requirements is not possible without the use of proper cables and connector assemblies. More information about EMC can be found in the Instruction Manual (9.17.076, chapter 4)
The Bronkhorst High-Tech B.V. series E-8000 is a modular Readout and Control (R/C) system for digital mass flow / pressure meters and controllers. Every model can be fitted with or without displays.
This Quick Installation Guide covers the instructions for E-8000 regarding:
This Quick Installation Guide also contains a short explanation of the basic operation for the E-8000 which will help you to start­up your E-8000. More detailed information can be found in documents listed below:
Consists information for general and advanced operation, more detailed information and instructions for troubleshooting.
Hookup diagrams
2
9.17.077
6. Inserting and removing cables
Before switching on power, please check if all external connections with meters/controllers and bus interfaces (if applicable) are properly connected. Before removing cables from the E-8000 always switch off power first. Your E-8000 is now ready for operation.
Basic operation
Buttons
The buttons have the following functions:
Enter selected menu Enter edit mode Confirm selection/changes
Menu selection up Select information field Next character in edit mode Up in table
Menu selection down Select information field Previous character in edit mode Down in table
Return to previous screen Undo, cancel and exit edit mode Switch content in the 'Custom readout 2' field
Display
The display contains the following readout areas:
A
Top line
C
Custom readout 1
B
Measure readout
D
Custom readout 2
Select instrument
To enter the 'instrument' mode, press the button until the red line appears above 'Custom readout 2' than press to activate this field.
Instruments will be indicated with their node address. Press or to search for an instrument on the bus. While the message “search” is displayed, the E-8000 is searching for a valid node address and it will not show any specific instrument info until an active node is found. When an active node address is found, the E-8000 will show the corresponding USERTAG or Serial Number in the 'Top line'. It will also show the actual measure and, if applicable, the actual setpoint.
Press to select this instrument to be operated by the E-8000 or press
to return to the previous selected instrument.
i
www
When the instrument is connected to a FLOW-BUS system, it is possible to select another instrument on this bus to operate. Check 'Select instrument' in section 3.1.4 of the Instruction Manual (9.17.076) how to select the 'instrument' item.
The number of displays that have the same instrument selected must not exceed 3.
© 2015 Bronkhorst High-Tech B.V.
3
Edit setpoint
Setpoint can only be edited when the setpoint parameter is displayed in 'Custom readout 1' or 'Custom readout 2'. To edit the setpoint press to select the readout area in which this parameter is displayed. Press to enter the edit mode, the first digit will lighten.
Use or to change the digits, press to select the next digit.
After the last digit is confirmed by pressing , the setpoint will be sent to the instrument.
Use the button to exit the edit mode and cancel the changes.
i
www
You can change the setpoint edit mode into ‘step’. This enables you to change the setpoint using fixed steps. See chapter 'Customize display info' in section 3.2.22 of the Instruction Manual (9.17.076).
i
www
If the entered setpoint is ignored, check controller mode. See chapter 'Controller mode' in section 3.2.8 of the Instruction Manual (9.17.076).
Reset alarm
Alarm messages will be shown in the 'Top line' of the display and 'Custom readout 2' will be selected automatically.
Enter the edit mode by pressing . Use or to select ‘yes’ and press again to confirm.
An alarm message will be occurring as long as the cause has not been removed/repaired.
The button can be used to exit the edit mode and cancel the changes. If you are not intending to reset the alarm, you can press to deactivate 'Custom readout 2'. Actual alarm messages will always been shown in the 'Top line'.
Security settings
The security settings screen allows you to define the access of the crucial menu items of the E-8000. For every item, you can choose for enable, disable or password. These settings can be assigned to the following items.
Edit setpoint Reset counter Reset alarm
Select instrument Settings menu Advanced menu item
i
www
To enter the security settings from the readout screen press both and
for 5 seconds till 'enter password' display appears. The default
password is 'abc'. Please refer to 'Security settings' in section 3.4.2 of the Instruction Manual (9.17.076) for more information.