INSTALLATION INSTRUCTIONS

HB0031

MODELS RMIP33 AND RMIP45

! INTENDED FOR DOMESTIC COOKING ONLY !

READ AND SAVE THESE INSTRUCTIONS

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.

Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)

Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)

REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register

V05861 rev G

! WARNING

! WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1.Use this unit only in the manner intended by the 1. SMOTHER FLAMES with a close-fitting lid,

manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN – You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels – This could cause a violent steam explosion.

4.Use an extinguisher ONLY if:

A.You own a Class ABC extinguisher and you know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department has been called.

D.You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA.

CAUTION

1.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

5.When cutting or drilling into wall or ceiling, do not 2. To avoid motor bearing damage and noisy and/or

 

appropriate for the size of the surface element.

8.

Because of the high exhausting capacity of this

 

 

unit, you should make sure enough air is entering

 

damage electrical wiring and other hidden utilities.

 

 

 

the house to replace exhausted air by opening a

 

 

window close to or in the kitchen.

 

 

unbalanced impellers, keep drywall spray,

6.

Ducted fans must always be vented to the

 

construction dust, etc. off power unit.

 

outdoors.

 

 

3.

Your insert motor has a thermal overload which will

7.

Do not use this unit with any solid-state speed

 

automatically shut off the motor if it becomes

 

control device other than RMIPWC optional wall

 

overheated. The motor will restart when it cools

 

mounted control.

 

 

 

down. If the motor continues to shut off and restart,

8.

To reduce the risk of fire, use only metal ductwork.

 

have the insert serviced.

9.

This unit must be grounded.

 

 

4.

The minimum hood distance above cooktop must

 

 

 

 

 

not be less than 24”. A maximum of 30” above

 

 

 

 

 

cooktop is highly recommended for best capture of

TO REDUCE THE RISK OF A RANGE TOP

 

cooking impurities.

GREASE FIRE:

 

 

5.

Two installers are recommended because of the

a)

Never leave surface units

unattended

at high

 

large size and weight of this unit.

 

settings. Boilovers cause

smoking and

greasy

6.

To reduce the risk of fire and to properly exhaust

 

spillovers that may ignite. Heat oils slowly on low or

 

air, be sure to duct air outside – Do not exhaust air

 

medium settings.

 

 

 

into spaces within walls or ceiling or into attics,

b)

Always turn hood ON when cooking at high heat or

 

crawl space or garage.

 

when cooking flaming foods.

 

7.

This product is equipped with a thermostat which

 

 

 

 

 

may start blower automatically. To reduce the risk

c) Clean ventilating fans frequently. Grease

should

 

of injury and to prevent power from being switched

 

not be allowed to accumulate on fan or filter.

 

on accidentally, switch power off at service panel

d)

Use proper pan size. Always use cookware

 

and lock or tag service panel.

 

 

 

 

 

 

9.

To reduce the risk of fire and electrical shock, the

 

 

 

 

 

Broan Elite models RMIP33 and RMIP45 must be

 

 

 

 

 

installed only with Broan interior blower models P5

 

 

 

 

 

or P8; Broan exterior models 331H, 332H, 335 or

 

 

 

 

 

336; Broan in-line blowers models HLB3, HLB6,

 

 

 

 

 

HLB9, HLB11. Other blowers cannot be substituted.

 

 

 

 

 

(Blowers sold separately).

 

 

 

 

10.

Use with approved cord-connection kit only.

 

 

 

 

11.

Please read specification label on product for

 

 

 

- 2 -

further information and requirements.

 

 

 

 

- RMIP33 AND RMIP45 INSERT SYSTEM -

INTERIOR BLOWERS

Model 647

 

Model 643

(7” Rd wall cap)

 

(8” Rd wall cap)

 

Model 634 or 644

Model 415

(roof cap)

8” Rd

 

adjustable

7” Rd adjustable

 

elbow (optional)

elbow (optional)

 

 

 

 

8” Rd

Model 407

 

standard

(7” Rd x 24’’

 

duct

section)

 

 

7” Rd metal

 

8” Rd metal

 

flexible duct

flexible duct

 

(optional)

(optional)

 

 

Model 412

Model 413

Model 459

transition

transition

transition

(31/4” x 10” to 7”)

(31/4” x 10” to 8”)

(31/4” x 14” to 8”)

 

 

Adapter and damper 31/4’’ x 14’’

Adapter and damper 31/4’’ x 10’’

 

(supplied with P8 blower)

(supplied with P5 and P8 blowers)

 

 

Flow deviator (supplied with P5 and P8 blowers)

RML3336S, RML3342S,

RML4548S, RML4554S or

RML4560S

Custom Hood Liner (optional)

 

RBFIP Series

 

Baffle Filters

 

(Optional)

RMIPWC

Model P5

Wall control

(Optional)

single-blower

 

(500 cfm)

RMP Series Backsplash (Stainless Steel wall covering with warming shelves. Optional)

RMIP33 OR RMIP45

INSERT

Rough-in kit

(supplied with P5 and P8 blowers)

Model P8 dual-blower (900 cfm)

NOTE: The dual blower P8 can be installed either with 7’’ round or 8’’ round ductwork.

For optimal air and quiet sound performance, use 8’’round ductwork.

HL0067

- 3 -

 

- RMIP33 AND RMIP45 INSERT SYSTEM -

IN-LINE AND EXTERIOR BLOWERS

Model 437

 

Model 441

 

(10” Rd wall cap)

(High capacity roof cap)

Model HLB9 (800 cfm)

 

or HLB11 (1100 cfm)

Model 335 (1200 cfm)

 

or 336 (1500 cfm)

 

in-line blower

 

Model 331H (600 cfm) exterior blower

 

(includes two 8” x 12” to

 

or 332H (900 cfm)

 

10’’ round transitions)

 

exterior blower

 

 

Model 441

 

 

(10” Rd wall cap)

 

 

Model HLB6 (600 cfm) in-line blower

(includes two 4½” x 18½” to 10’’ round transitions)

Model 418 10” Rd adjustable elbow

Model HLB3 (280 cfm) (optional) in-line blower

(includes one 8” to 10” round transition)

10” Rd metal flexible duct (optional)

RMIPWC Wall control (Optional)

RBFIP Series Baffle filters (Optional)

RMP Series Backsplash (Stainless Steel wall covering with warming shelves. Optional)

 

Model 421

 

(10” Rd. vert.

 

in-line damper)

Model 410

Recommended

for use with

(10” Rd duct

exterior blowers

- 2ft. sections)

RML3336S, RML3342S,

RML4548S, RML4554S or

RML4560S

Custom Hood Liner (optional)

RMIP33 OR RMIP45

INSERT

332KR in-line and exterior blower rough-in kit - Purchase separately.

HL0068

- 4 -

 