Broan RMDD3604EX User Manual

SPECIFICATION SHEET
MODELS RMDD3004EX, RMDD3604EX, RMDD4804EX DOWNDRAFT
For use with external blowers.
Exhaust your cooktop without the use of an over­head hood. Control a powerful external blower from the cooktop location. Compact design is installed directly behind cooktop.
FEATURES
HOUSING:
Rugged steel construction
Finished with silver paint
Space-saving - can be used with most cooktops on the
market
30", 36", or 48" widths - Fits standard-size cabinets
CHIMNEY ASSEMBLY:
Brushed stainless steel cover - just press button to turn
unit "ON"
Chimney rises 9½" when activated - ideal for large pots
and pans
Stylish, stainless steel filters with aluminum mesh - easy
to remove and dishwasher-safe
Stainless steel chimney front and back - makes cleanup
quick and easy
Flush-mounted, infinite rotary speed blower control
Heat Sentry adjusts speed of blower to HIGH in case of
excess heat
Conveniently located button - press to lower air vent and
turn unit "OFF"
OPTIONAL Remote Control (Model RMDDRBK) activates
downdraft from alternate location
DUCT CONNECTOR HOUSING:
Rugged steel construction with galvanized finish
3¼" x 14" rectangular duct connector (8" round duct using
Model 459 transition)
3-position discharge - movable to adjust to floor joists
TYPICAL SPECIFICATION
Downdraft blower system shall be Broan Elite Model RMD­D3004EX (RMDD3604EX) (RMDD4804EX).
Unit shall be for indoor use only.
Unit to have steel housing with silver paint finish. Air vent to rise at least 9½" and have a stainless steel front and for ease of cleaning.
Filters to be stainless steel with aluminum mesh, easy to remove and dishwasher-safe.
3¼" x 14" duct connector shall be adjustable to accomodate ductwork from left, right, or below and have 7½" side to side adjustment.
Unit must accept an optional remote control activation button.
Unit to include Heat Sentry, to adjust blower speed to HIGH in case of excess heat.
Downdraft system shall operate on 120 VAC and be able to be plugged into a standard grounded outlet. It will have an infinite speed blower control.
SPECIFICATIONS
VOLTS HZ AMPS DUCT
120 60 6 3¼" x 14"
back
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
Broan-NuTone Canada, Inc. Mississauga, Ontario www.broan.ca 877-896-1119
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
90M 99043190C
INSTALLATION PLANNING • MODELS RMDD3004EX, RMDD3604EX, RMDD4804EX
DIMENSIONS
NOTE: Dimensions shown are for reference only. Before cutting out countertop, refer to instructions packed with downdraft and cooktop.
*
*
Dimensioned from top
*
of countertop
TYPICAL INSTALLATION
COUNTER
TOP
COOK TOP
CHIMNEY TOP
DOWNDRAFT
A
COUNTER TOP
COOKTOP
FRONT TO BACK
INSIDE CABINET DEPTH
Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The RMDD3004EX can be installed in most standard 30" wide cabi­nets, (RMDD3604EX can be installed in most standard 36" wide cabinets), (RMDD4804EX can be installed in most standard 48" wide cabinets).
Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.
Pay special attention to the 4 areas of potential interference highlighted above. A countertop with (A) a raised lip and/or (B) a backsplash, may not allow enough flat countertop for a proper installation. The back of the downdraft cut-out will be 1¾" from the cooktop and 2" of FLAT countertop is needed behind cooktop.
1 3/4 "
2"
B
DOWNDRAFT
DUCTWORK
This downdraft blower system is designed for use with 3¼" x 14" rectangular ductwork (can be transitioned to 8" or 10" round). The blower discharge can be positioned in one of 3 directions with 7½" movement side to side.
AIR VENT
120 VAC GOUNDED OUTLET
CABINET FRONT
GEAR MOTOR COVER
BLOWER
BOX
3-1/4" X 14" DUCT CONNECTOR
ELECTRICAL
The unit has an 18-in. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord.
RIGHT DISCHARGE
LEFT DISCHARGE
3¼" x 14" TO 8" RD. TRANSITION
5 F T.
3¼" X 14"
o
ELBOW
90
DOWN DISCHARGE (as shipped)
8" RD. ELBOW
19 F T.
11 FT.
The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The chart above, shows equivalent feet of elbows and transitions. The number of feet of straight 3¼" x 14" or 8" duct plus the equivalent feet of elbows or transitions to be used should equal 40 feet or less.
The equivalent feet of various roof and wall caps has been taken into consideration. Do not include them in this calculation.