Broan RM523604, RM523004, RM524204 Specifications

RM52000 SERIES
( )
RANGE HOOD
SPECIFICATION SHEET
A wall-mounted chimney hood with sleek, graceful, hand-rolled curves that is engineered to meet the requirements of today’s conventional appliance and kitchen styles.
FEATURES
Professional style design
430 Stainless Steel #4 Brushed construction
Wall mount installation
Seamless corners for easy cleaning
Ducted/non-ducted telescopic flue - fits 8 ft. to 9 ft. ceilings
6” round duct connector/backdraft damper
370 cfm centrifugal blower
Three-speed slide control
Dual halogen lighting (2 x 20 Watt, Type JC 12V 20W G4
Base - bulbs included)
Dishwasher-safe aluminum filter features a quick-release
latch and professional style appearance
Available sizes: 30”, 36”, 42”
Heat Sentry
speed when excess cooking heat is detected
OPTIONS
TM
- automatically turns blower to high
Replacement grease filters available
Non-ducted recirculation kit (Model RRK51)
Replacement charcoal filter (Model FILTERSQUARE)
Flue Extension for 10 ft. ceiling Model RFX5204 (ducted
applications), Model RFXN5204 (non-ducted applications) (35-1/16” long)
TYPICAL SPECIFICATION
Range hood shall be Broan Model RM52000. Unit shall be for indoor use only. Unit shall be convertible between ducted (using a washable
aluminum filter) and non-ducted (using a recirculation kit). Motor to be permanently lubricated. Unit shall have three-speed fan switch and separate light switch. Sides shall be mitered and bottom edge hemmed - with no
sharp edges. Air delivery shall be no less than 370 CFM. Unit shall be U.L. and
cUL listed.
SPECIFICATIONS
VOLTS AMPS CFM SONES DUCT
120 2.63 370 7.0 6” round
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
90M 99043164E
HVI-2100 CERTIFIED RATINGS comply with new testing technologies and procedures prescribed by the Home Ventilating Institute, for off-the-shelf products, as they are available to consumers. Product performance is rated at 0.1 in. static pressure, based on tests conducted in a state-of-the-art test laboratory. Sones are a measure of humanly-perceived loudness, based on laboratory measurements.
RM52000 SERIES WIRING
L
L
C
5 "
1
16
19” - 22”
8”
4”
CENTERLINE OF
HOOD & DUCT
120-VOLT, 60 HZ, GROUNDED WALL OUTLET
OFFSET FROM DUCT CENTER LINE
(STAY WITHIN 8” DIMENSION)
RM52000 SERIES MOUNTING
FRAMING BEHIND
WOOD CROSS
SUPPORT
WOOD CROSS SUPPORT –
SECURED TO FRAMING AND
LOCATED BEHIND DRYWALL
DRYWALL
CEILING DUCT HOOD DISTANCE ABOVE 36” HIGH COOKTOP (SEE NOTE 1)
HEIGHT METHOD 24” 25” 26” 27” 28” 29” 30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET
9 FEET DUCTED OR 41” 42” 43” 44”
10 FEET DUCTED OR NON-DUCTED 40” 41” 42” 43” 44” (SEE NOTE 2)
DUCTED 38” 39” 40” 41” 42” 43” 44”
NONDUCTED 38” 39” 40” 41”
NONDUCTED
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711 Broan-NuTone Canada, Inc. Mississauga, Ontario www.broan.ca 877-896-1119
( )
MOUNTING BRACKET LOCATION (ABOVE 36” HIGH COOKTOP)
NOTES:
1. Minimum hood distance above cooktop must not be less than 24”.
A maximum of 30” above the
cooktop is highly recommended for best capture of cooking impurities.
Distances over 30” above the
cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
2. Requires optional 10-foot flue extension model RFX5204 (ducted) or RFXN5204 (non­ducted).
Loading...