TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal
Do not use this fan with any solid-state speed control device.
9.
10. As an alternative, this product may be installed with the
UL-approved cord kit designated for the product, following
instructions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambéing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
ductwork.
WARNING
2. NEVER PICK UP A FLAMING PAN — You may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. Yo u can fight the fire with your back to an exit.
* Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. F o r indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impeller, keep drywall spray, construction dust, etc., off power
unit.
4. Do not use over cooking equipment greater than 70,000
BTU/hr. as the blower motor will shut down intermittantly.
5. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues
to shut off and restart, have the hood serviced.
6. The top of the hood MUST NOT BE LESS than 30” and at a
maximum of 36” above cooktop for best
impurities.
7. This hood is not intended to be used as a shelf.
8. Please read specification label on product for further
information and requirements.
Register your product online at: www.broan.com
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.
captur
e of cooking
MODELS QP430SS • QP436SS • QP442SS
Page 2
CONTENTS
INCLUDED WITH THE HOOD:
GREASE
FILTERS
(2 - FOR 30” & 36” HOODS)
(3 - FOR 42” HOODS)
(4)
HALOGEN
BULBS
(1) PARTS BAG CONTAINING:
(3)
WIRE
NUTS
(9)
#8 X 1/4”
DUCT
CONNECTOR
SCREWS
DAMPER / DUCT
CONNECTOR
(1) 7” ROUND
DUCT
CONNECTOR
(1) VERTICAL
AIR DIVERTER
CUP TOOL
#10 X 5/8”
RD. HD.
MOUNTING
SCREWS
(1) 3¼” X 14”
(1)
BULB
SUCTION
(5)
OPERATION
Always turn the hood ON before cooking in order to establish an
air flow in the kitchen. After turning off the range, let the hood run
for a few minutes to clear the air.
Operate the hood as follows:
NOTE
The
and buttons are used to adjust and toggle the menu
and timer settings.
LIGHT (3-Pushbutton Switches 4-light Settings)
Turns the light on the low setting and activates a green indicator
above the button. Pressing the
night time setting and illuminates the
Turns the light on the medium setting and activates a green
indicator above the button.
Turns the light on the high setting and activates a green
indicator above the button.
Pressing and holding the same light button again will turn the lights
off.
When the night time setting is active, pressing and holding the low
light setting button will turn the night time setting off.
button a second time activates the
indicator.
CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter,
fan and grease-laden surfaces. Use only a clean cloth and mild
detergent solution on stainless and painted surfaces.
Clean all-metal filters in the dishwasher using a non-phosphate
detergent. Discoloration of the filter may occur if using phosphate
detergents, or as a result of local water conditions - but this will
not affect filter performance. This discoloration is not covered by
the warranty.
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the motor with the exact service motor. The impeller should also
be replaced.
Use 120 V, 50 W, shielded halogen bulbs - MR16 with GU10 base.
FAN (3-Pushbutton Switches 4-fan speeds)
Turns the fan on the low speed and activates a green indicator
above the button.
Turns the fan on the medium speed and activates a green
indicator above the button.
Turns the fan on the high speed and activates a green indicator
above the button. Pressing the
the boost fan speed and illuminates the
Pressing and holding the same fan button again will turn the fan off.
When the boost speed is active, pressing and holding the high
speed button will turn the boost speed off.
NOTE
This hood utilizes an offset blower design to achieve greater
performance and lower sound levels. As a result, you may notice
that cooking impurities are more attracted to one side or appear
to be pulled-in faster than they appear on the opposite side. This
is completely normal. The hood has been designed and tested
to provide good capture of cooking impurities and odors under
all normal cooking conditions regardless of the cooking location
on the cooktop. Please note that cooking on the rear burners will
always result in the best capture of cooking impurities, regardless
of the hood design.
button a second time activates
indicator.
10-MINUTE DELAY OFF
When your hood fan is on (any speed) press the
activate the delay off feature. When activated, the hood fan will
automatically turn off after 10-minutes has elapsed. The delay
feature is active when the following appear on the LED screen: A
green indicator illuminated above the delay
countdown “10-0”, and a clockwise rotating LED. The delay
button can be pressed once again, to stop the delay countdown.
Pressing the
Pressing and holding the button will turn off the feature.
TIMER
Press the
and buttons to reduce or advance the timer setting to
the
the desired duration. When the desired timer setting is reached,
allow 3 seconds without pressing any additional button or press
the
the countdown will be displayed on the LED screen along with
an green indicator above the
reached “0:00”, an audible beep will be heard. The beep will
continue until the timer button
timer countdown can be stopped at any time by pressing the
the timer countdown. Pressing and holding the
turn off the feature. Note that when both the timer and delay off
features are active together, the timer function will be illuminated
on the LED display, and the delay off countdown will be active,
but not displayed.
button once again. The timer will then activate, and
once again. Pressing the button again will resume
button again will resume the delay countdown.
button to activate the timer setting feature. Use
button. After the timer has
is pressed once again. The
button, a numeric
button to
button will
MODELS QP430SS • QP436SS • QP442SS
Page 3
CLOCK SETTING
Press the
LED screen. Use the
hours for the clock. A small indicator will illuminate in the left
corner of the LED screen to designate “pm”. After the hours are
set, press the
selection. The minutes will begin blinking in the LED screen. Use
and buttons to set the minutes. Press the button
the
again to advance the menu to select “display” settings.
DISPLAY (default from factory - display ON)
The LED screen will display the display feature -d-. Use the
button to toggle the LED screen on (d on) or off (doFF). When
the display off (doFF) feature is selected, the LED display clock
illumination is disabled. Press the
the menu to select the “Sleep” setting.
SLEEP MODE (default from factory - OFF)
The LED screen will display the “Sleep” feature -S-. Use the
or button to toggle the Sleep feature on (S on) or off (S off).
When the Sleep on (S on) feature is selected, the LED screen
and fan/light LED indicators are disabled. The ambient light
sensor, delay-off and timer features will also be disabled. All
controls for the fan and light operation, including Heat Sentry,
are still active. Press the
menu to select the “Ambient Light Sensor” setting. Note: To
access the feature menu when the Sleep Mode is active, press
and hold the
button once, the “hours” will begin blinking in the
and buttons to set the appropriate
button to advance the menu to the minute
or
button again to advance
button again to advance the feature
button for 2 seconds.
FEATURE MENU
Your hood offers many settings that can be accessed and
adjusted by scrolling through the feature menu. Your hood fan
must be off to be able to activate and access the feature menu.
Pressing the
feature menu. Pressing the
menu is active will scroll through the various features that can
be adjusted/set. When the feature menu is active, if a button is
not pressed within 10 seconds or after scrolling through all menu
settings, the feature menu will automatically be exited, and all
selected settings will be saved. A green indicator above the
icon will illuminate when the feature menu is active. The following
features can be adjusted sequentially:
button when the hood fan is off will activate the
button again when the feature
AMBIENT LIGHT SENSOR (default from factory - Level 1 ON)
There are two level settings for the ambient light sensor. When
either of the two settings is active, the light sensor will detect a low
level of light in your kitchen, and will automatically turn the task
lights on the hood to the night time setting. The other light settings
are still functional. If selected when the ambient light sensor is
active, they will temporarily overide the ambient light sensor until
they are turned off. The level 1(Aon1) ambient light sensor setting
will require your kitchen to be more dark than the level 2 (Aon2)
setting before activating the night time setting. The LED screen
will display the ambient light sensor function -A-. Use the
button to select the light sensor setting Aon1, Aon2, or AoFF. The
Off (AoFF) setting deactivates the automatic ambient light sensor
feature so the night time light operation is manual.
Note that the feature menu can be exited any time by not
pressing any button(s) for 10 seconds or by scrolling through the
entire feature menu.
or
HEAT SENTRY SYSTEM
This range hood is equipped with an advanced Heat Sentry
system that monitors excessive temperature and automatically
adjusts the fan to the appropriate setting.
1) If the fan is on, the Heat Sentry system will increase the
fan setting when the temperature is elevated. If the temperature
continues to rise, the Heat Sentry system will continue to increase
the fan setting until the temperature is stabilized or reduced. The
flashing light above the fan button shows the Heat Sentry system
fan setting. Once the temperature has reduced, the Heat Sentry
system will change the fan to the original setting.
2) If the fan is off, the Heat Sentry system will automatically turn
the fan on to its highest speed when the temperature is above
normal. When the Heat Sentry system is on, the light above the
high speed fan button will flash on and off. After the temperature
has lowered to normal, the fan speed will be reduced until the
temperature has stabilized, then the fan will turn off.
Note: Canadian version does not have this function.
MODELS QP430SS • QP436SS • QP442SS
Page 4
MAKE-UP AIR DAMPER
The hood is compatible with Broan Make-Up Air Damper Model
MD6T or Model MD8T (optional). Purchase separately.
Make the connection to the Make-Up Air Damper with low voltage
wiring, as shown. See Make-Up Air Damper instructions for
additional information.
BACK OF HOOD
LOW-VOLTAGE CONNECTOR
FOR MAKE-UP AIR DAMPER
RANGE
HOOD
LOW-VOLTAGE
WIRES
MAKE-UP AIR
DAMPER
FUSES
RANGE HOOD CONTROL BOARD
MAIN
FUSE
LIGHT
FUSE
The Range Hood Control Board contains a Main Fuse and a
Light Fuse to protect the controls from power surges. If a fuse has
opened (blown), the green fan setting or light setting indicators will
not operate properly when the fan or light buttons are pressed, and
the fan and lights will not turn on.
New fuses can be purchased at your local electronic supply store.
Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridgetype fuses.
To replace a fuse (by qualified person(s):
1. Disconnect power at service entrance.
2. Remove filters and bottom pan.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics are needed.
120
VAC
24
VAC
DAMPER
MOTOR
REMOTE CONTROL
The hood is compatible with Broan RF Remote Control Model
BCR1 (optional). Purchase separately.
PREPARE HOOD LOCATION
cabinets only)
MODELS QP430SS • QP436SS • QP442SS
Page 5
ROOF CAP
SOFFIT
CABINET
HOODHOOD
30" - 36" ABOVE
COOKING SURFACE
3¼" X 14" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
WALL CAP
3¼" X 14" DUCT
(For horizontal discharge)
1 Determine whether hood will discharge vertically (3¼”
x 14” or 7” Round), or horizontally (3¼” x 14” only). For
vertical or horizontal discharge, run ductwork between
the hood location and a roof cap or wall cap. For best
results, use a minimum number of transitions and elbows.
2 Use the proper diagram, as follows, for placement of
ductwork and electrical cutout in cabinet or wall.
8" DIA.
HOLE
7-IN. ROUND
7-IN. ROUND
45/8"
13
/
12
"
16
CABINET FRONT
CABINET
BOTTOM
7-INCH ROUND DISCHARGE
DUCT & ELECTRICAL CUTOUTS
9"
DUCT
DUCT
ACCESS
ACCESS
HOLE
HOLE
21/8"
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
30” HOOD
MOUNTING SCREW LOCATIONS
5
/
11
"
8
3
/
"
4
5
/
2
"
8
10
7
/
"
8
CABINET FRONT
CABINET
BOTTOM
4½"
CABINET
BOTTOM
¾"
CABINET FRONT
HORIZONTAL DUCT
4"
ACCESS HOLE
1
/
7
4
CENTER
VERTICAL DISCHARGE
DUCT & ELECTRICAL CUTOUTS
9"
1
/
7
4
VERTICAL DUCT
ACCESS HOLE
1
"
/
7
"
4
1
/
2
"
8
ELECTRICAL
CENTER
LINE
ACCESS HOLE
(in cabinet bottom)
HORIZONTAL DISCHARGE
DUCT & ELECTRICAL CUTOUTS
35/8"
13/8"
3
/8"
ELECTRICAL
"
LINE
1
/
7
"
4
9"
MAKE-UP AIR
DAMPER ELECTRICAL
CONNECTION HOLE
(in wall)
ACCESS
HOLE
(in wall)
WOOD SHIMS
(recessed-bottom
14
17
CABINET FRONT
WOOD SHIMS
(recessed-bottom
cabinets only)
5
/
11
8
5
/
" (36” hood)
8
5
/
" (42” hood)
8
CABINET
BOTTOM
"
HOOD MOUNTING
CENTER LINE
SCREWS (5)
36” & 42” HOODS
MOUNTING SCREW LOCATIONS
5
/
14
" (36” hood)
8
5
/
17
" (42” hood)
8
3
/
"
4
5
/
2
"
8
CENTER
LINE
HOOD MOUNTING
SCREWS (5)
10
7
/
"
8
PREPARE THE HOOD
MODELS QP430SS • QP436SS • QP442SS
Page 6
3 Remove parts bag and 3¼” x 14” damper/duct connector
from inside the hardware box included with the hood.
4 Remove all protective polyfilm from the hood.
5 Remove 6 Screws holding Bottom Pan to hood. Set bot-
tom pan and screws aside.
SCROLL
CAP
BUSHING
SCREWS
LEFT-HAND
LIGHT PANEL
TOP/BACK
EDGE OF
HOOD
7” ROUND
8 VERTICAL 7” ROUND & 3¼” X 14” INSTALLATION
ONLY:
Attach 3¼” x 14” Damper/Duct Connector (if using 3¼”
x 14” duct) or 7” Round Duct Plate (if using 7-inch round
duct) over the knockout opening.
Notes:
To accomodate off-center ductwork, the 3¼” x 14” damper/
duct connector can be installed up to ½” on either side
of the hood center and the 7” round duct plate can be
installed up to ½” on either side of the hood center.
Install the 3¼” x 14” Damper/Duct Connector with the
Damper Flap Pivot nearest the Top/Back Edge of Hood.
DAMPER / DUCT CONNECTOR
DUCT
PLATE
3¼” X 14”
DAMPER
FLAP
PIVOT
6 FOR 30” MODEL ONLY:
Remove Left-Hand Light Panel by removing (2) Screws
and disconnecting electrical connector.
Remove Rubber Bushing in Scroll Cap. Set parts aside.
7” ROUND
KNOCKOUT
PLATE (also
remove 3¼” x 14”
vertical plate)
3¼” X 14”
VERTICAL
3¼” X 14”
HORIZONTAL
KNOCKOUT
PLATE
7 Remove 3¼” x 14” vertical, 3¼” x 14” horizontal, or 7-inch
round Knockout Plate(s) as appropriate for your ducting
method.
KNOCKOUT
PLATE
9 HORIZONTAL 3¼” X 14” INSTALLATION ONLY:
Remove and discard Vertical Diverter Plate.
MODELS QP430SS • QP436SS • QP442SS
Page 7
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
ELECTRICAL
WIRING BOX
COVER
ELECTRICAL
POWER
CABLE
KNOCKOUT
10 Remove Electrical Wiring Box Cover from inside
of hood and appropriate Electrical Power Cable
Knockout from top or back of hood.
CONNECT THE WIRING
GROUND
SCREW
HOUSE POWER CABLE
14 Connect House Power Cable to range hood wiring -
BLACK to BLACK, WHITE to WHITE, and GREEN or
BARE WIRE to Ground Screw. Replace electrical wiring
box cover.
15 FOR 30” MODEL ONLY:
Replace rubber bushing, re-connect left-hand light panel
electrical connector, and re-attach light panel with (2)
screws removed in Step 6.
16 Re-attach Bottom Pan with 6 Screws removed in Step 5.
17 Install aluminum filters.
HOW TO CHANGE LIGHT BULBS
HOUSE
POWER CABLE
11 Run House Power Cable between service panel and hood
location. Attach power cable to hood using appropriate clamp.
Hang hood from (4) mounting screws driven part-way into
12
cabinet locations (shown in illustrations under “PREPARE
HOOD LOCATION”). Mounting screws are included in
parts bag. Slide hood back towards wall until mounting
screw heads are engaged in narrow end of keyhole slots
in top of hood. Tighten screws securely. Add 5th mounting
screw in center hole in hood and tighten securely.
13
Connect ductwork to hood and use duct tape to make
joints secure and air-tight. Make sure the damper / duct
connector enters the ductwork and that the damper opens
and closes freely.
SUCTION
CUP TOOL
HALOGEN
BULB
(2)
ROTATE
CLOCKWISE
LIGHT PANEL
SCREWS
CAUTION: Bulbs may be hot. Refer to bulb
packaging for further information.
Install (4) Halogen Bulbs (included with hood). Use 120 V, 50
W, shielded halogen bulbs - MR16 with GU10 base.
NOTE: Suction Cup Tool (included with hood) can be used to
install and remove light bulbs.
Align pins on bulb with large diameter opening on socket, then
push bulb in towards hood and rotate clockwise until firmly
seated.
The position of the bulb socket (depth) is adjustable and may
require adjustment when:
a) certain brands of bulbs are difficult to install.
b) the bulb protrudes too far below the light panel.
(1)
PUSH IN
LIGHT PANEL
LAMP SOCKET
BRACKET
MODELS QP430SS • QP436SS • QP442SS
Page 8
SERVICE PARTS
LIGHT
PANEL
SCREWS
To change the depth of bulb sockets:
1. Remove bottom pan (See Step 5).
2. Remove 2 Light Panel Screws and Light Panel. Set
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of one (1) year from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
During this one year period, Broan-NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under normal
use and service. THIS WARRANT Y DOES NOT EXTEND TO FLUORESCENT
LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR
DUCTING. This warranty does not cover (a) normal maintenance and service
or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S
NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states
do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights, which vary from
state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part.
At the time of requesting warranty service, you must present evidence of the
original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711