Broan Dh50rdf Installation Guide

CEILING VENTILATORS/VENTILADORES DE CIELO RASO
MODELS/MODELOS HD50 • HD80
READ AND SAVE THESE
INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac­turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the ser­vice disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust­ing of gases through the flue (chimney) of fuel burning equip­ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFP A), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au­thorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust haz­ardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbal­anced impellers, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further infor­mation and requirements.
Installer: Leave this manual with the homeowner. Homeowner: Use and Care information on page 4.
!
TYPICAL INSTALLATIONS
POWER CABLE
MOUNTING TABS
CEILING
JOIST
HOUSING
CEILING
HOUSING MOUNTED DIRECTLY TO JOIST
MATERIAL
2x6 (or larger) Discharge parallel to joists.
POWER CABLE
2 x 4 CEILING JOIST or
TRUSS
CEILING
MATERIAL
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge parallel to joists.
POWER CABLE
"I"
CEILING
JOIST
MATERIAL
HOUSING MOUNTED TO “I” JOIST
Requires additional framing for mounting tabs.
Discharge parallel to joists.
POWER CABLE
MOUNTING TABS
HOUSING
CEILING
MATERIAL
GRILLE
HOUSING MOUNTED TO ADDITIONAL FRAMING
Discharge 900 to joists.
POWER CABLE
MOUNTING TABS
HOUSING
2 x 4
CEILING
CEILING
MATERIAL
JOIST or
TRUSS
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing for mounting tabs.
Discharge 900 to joists.
POWER CABLE
MOUNTING TABS
MOUNTING
TABS
HOUSING
GRILLE
MOUNTING
4" ROUND
DUCT
4" ROUND
DUCT
GRILLE
4" ROUND
DUCT
GRILLE
TABS
HOUSING
GRILLE
ADDITIONAL
FRAMING
ADDITIONAL
FRAMING
ADDITIONAL
FRAMING
ADDITIONAL
FRAMING
"I"
JOIST
CEILING
*
CEILING
*
JOIST or
TRUSS
*
2 x 4 CEILING JOIST or
TRUSS
*
JOIST
2 x 4
LEA Y CONSERVE ESTAS
INSTRUCCIONES
ADVERTENCIA
PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO SIGUIENTE:
1. Utilice esta unidad solamente de acuerdo con las instrucciones del fabricante. Si tiene preguntas comuníquese con el fabricante a la dirección o al número telefónico que se indica en la garantía.
2. Antes de dar servicio o limpiar la unidad, interrumpa el suministro de energía en el panel de servicio y bloquee los dispositivos de desconexión para evitar la reinstalación ac­cidental de la energía. Cuando no se puedan bloquear los dispositivos de desconexión, fije seguramente en el panel de servicio un medio de advertencia que sea visible, como por ejemplo una etiqueta.
3. Una persona o personas calificadas deben realizar el trabajo de instalación y el cableado eléctrico, de acuerdo con todos los códigos y normas aplicables, inclusive los códigos y normas de construcción para evitar incendios.
4. Se necesita suficiente aire para que se realice la combustión y la descarga de gases adecuadas a través de la chimenea del equipo para quemar combustible a fin de evitar las corrientes de inversión. Observe los lineamientos del fabricante del equipo de calefacción y las normas de seguridad, como por ejemplo las publicadas por la Asociación Nacional de Protección contra Incendios (National Fire Pro­tection Association: NFPA), y la Sociedad Americana de Ingenieros en Calefacción, Refrigeración y Sistemas de Acondicionamiento de Aire (American Society for Heating, Refrigeration and Air Conditioning Engineers: ASHRAE), y los códigos locales.ditioning Engineers (ASHRAE), and the local code authorities.
5. Cuando corte o perfore la pared o el cielo raso, tenga cuidado de no dañar el cableado eléctrico ni otras conexiones de servicios que se encuentren ocultas.
6. Los ventiladores con conductos siempre deben tener salida hacia el exterior.
7. Si se va a instalar esta unidad sobre una tina o ducha, debe marcarse que es apropiada para esta aplicación y conectarse a un GFCI (interruptor accionado por pérdida de conexión a tierra) en un circuito de derivación protegido.
8. Nunca coloque el interruptor en un lugar en donde se pueda alcanzar desde la tina o ducha.
9. Esta unidad debe conectarse a tierra.
PRECAUCIÓN
1. Esta unidad debe usarse solamente para ventilación gen­eral. No la utilice para la descarga de materiales ni vapores peligrosos o explosivos.
2. Para evitar causar daño a los cojinetes del motor y pistones impulsores ruidosos y/o no balanceados, mantenga los aerosoles para pirca, el polvo de construcción, etc. lejos del motor.
3. Por favor consulte la información y los requerimientos adicionales contenidos en la etiqueta de especificaciones que se encuentra en el producto.
!
HOUSING
"I"
JOIST
CEILING
MATERIAL
HOUSING MOUNTED TO “I” JOIST
GRILLE
ADDITIONAL
FRAMING
"I"
JOIST
*
Requires additional framing for mounting tabs.
Discharge 900 to joists.
Additional framing must be a 2x6 (minimum height), at
* least 9-inches long.
A la persona que realiza la instalación: Deje este manual con el dueño de la casa. Al dueño de la casa: Las instrucciones de operación y limpieza se encuentran en la página 4.
INSTALACIONES TÍPICAS
CABLE DE ALIMENTACIÓN
VEGUETA
DEL
TECHO
MATERIAL
DEL TECHO
CUBIERTA MONTADA
DIRECTAMENTE EN LA VIGUETA
2x6 (o más grande). Descarga paralela a las viguetas.
CABLE DE ALIMENTACIÓN
VIGUETA O
VIGA DE
2x4 DE
CIELO RASO
MATERIAL
DE CIELO RASO
CUBIERTA MONTADA EN UNA VIGA DE 2x4
Se requiere una estructura adicional para las aletas de
montaje. Descarga paralela a las viguetas.
CABLE DE ALIMENTACIÓN
VIGUETA
MATERIAL
"
I
"
DE CIELO RASO
CUBIERTA MONTADA EN UNA VIGUETA “I”
Se requiere una estructura adicional para las aletas de
montaje. Descarga paralela a las viguetas.
CABLE
DE ALIMENTACIÓN
ALETAS DE MONTAJE
CUBIERTA
MATERIAL
DEL TECHO
REJILLA
CUBIERTA MONTADA
EN UNA ESTRUCTURA ADICIONAL
Descarga a 90º de las viguetas.
CABLE DE
ALIMENTACIÓN
DE 4" (10,2 CM)
ALETAS DE MONTAJE
CUBIERTA
CUBIERTA
REJILLA
ALETAS DE
MONTAJE
CUBIERTA
REJILLA
ALETAS DE
MONTAJE
CUBIERTA
REJILLA
CONDUCTO
REDONDO DE
4" (10.2 CM)
ESTRUCTURA
ADICIONAL
CONDUCTO
REDONDO
ALETAS DE
MONTAJE
ESTRUCTURA
ADICIONAL
ESTRUCTURA
ADICIONAL
VIGUETA
*
DEL TECHO
*
VIGUETA O
VIGA DE
2x4 DE
CIELO RASO
*
"
I
"
VIGUETA
TYPICAL INSTALLATIONS INSTALACIONES TÍPICAS
CONDUCTO
4" ROUND
DUCT
SUSPENDED
CEILING MATERIAL
HOUSING
GRILLE
POWER
CABLE
MOUNTING
TAB
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER. (Ad­ditional framing must be a 2x6 (minimum height), at least 9-inches long.)
1. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.
Additional positioning feature for 5/8”, 1”, & 1­1/4” thick ceiling material:
Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for that ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material:
Bend two tabs, on side of housing, until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
- PLEASE NOTE -
New Construction
HOLES
OROFICIOS
TAB
ALETA
1-1/4
1
5/8
BORDE INFERIOR DE LA VIGUETA
900 outward. Lift housing
BOTTOM EDGE OF JOIST
REDONDO DE
4" (10.2 CM)
MATERIAL DEL
TECHO SUSPENDIDO
TECHOS SUSPENDIDOS
CUBIERTA
REJILLA
CABLE
DE ALIMENTACIÓN
ALETA DE MONTAJE
Cubierta montada con cables. Montaje de tres puntos.
INST ALACIÓN DE LA CUBIERT A
LAS SIGUIENTES ILUSTRACIONES DE LA INSTALACIÓN MUESTRAN VIGUETAS DE 2 X 6. SI LA INSTALACIÓN ES EN UNA VIGA O EN UNA VIGUETA EN “I”, MONTE EL VENTILADOR EN LA ESTRUCTURA ADICIONAL DE LA MISMA MANERA. (La estructura adicional debe ser un tramo de 2x6 (altura mínima), de al menos 9 pulgadas (23 cm) de largo.)
1. Seleccione la ubicación del ventilador con lámpara en el cielo raso. Para obtener el mejor rendimiento posible, utilice un tramo de conductos lo más corto posible y un
están marcados con varios espesores del material del cielo raso. Coloque la cubierta de manera que el borde inferior de la vigueta sea visible a través del conjunto de orificios que coinciden. Ahora la cubierta se encuentra en la posición adecuada para ese espesor del material del cielo raso.
Característica adicional para la colocación en material de cielo raso de ½” (1.3 cm):
Doble a 90º y hacia afuera las dos aletas que se encuentran a los costados de la cubierta. Levante la cubierta hasta que las aletas entren en contacto con la cara inferior de la vigueta.
Marque el orificio con forma de cerradura de ambas abrazaderas de montaje.
- POR FAVOR NOTE -
Construcción nueva
número mínimo de codos.
2. Coloque las abrazaderas de montaje contra la vigueta, de manera que el borde inferior de la cubierta quede al ras del cielo raso terminado.
Característica adicional para la colocación en material de cielo raso de 5/8” (1.6 cm), 1” (2.5 cm) y 1 ¼” (3.2 cm):
Los orificios que se encuentran en las esquinas de la cubierta
VIGUETA
O VIGA DE
2x4 DE CIELO RASO
MATERIAL
DE CIELO RASO
ESTRUCTURA
ADICIONAL
REJILLA
VIGUETA
*
O VIGA DE
2x4 DE
CIELO RASO
CUBIERTA MONTADA EN UNA VIGA DE 2x4
Se requiere una estructura adicional para las aletas de
montaje. Descarga a 90º de las viguetas.
CABLE DE
ALIMENTACIÓN
VIGUETA
"
I
"
DE CIELO RASO
CONDUCTO
REDONDO DE
4" (10,2 CM)
ALETAS DE MONTAJE
CUBIERTA
MATERIAL
ESTRUCTURA
REJILLA
ADICIONAL
*
VIGUETA
"
I
"
CUBIERTA MONTADA EN UNA VIGUETA “I”
Se requiere una estructura adicional para las aletas de
montaje. Descarga a 90º de las viguetas.
La estructura adicional debe ser un tramo de 2x6 (altura
* mínima), de al menos 9 pulgadas (23 cm) de largo.
3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
4. Hang housing from nails and pound nails tight. T o ensure a noise-free mount, pound another nail through the top hole of each mounting tab.
2
3. Coloque la cubierta a un lado e introduzca parcialmente los clavos en la vigueta, en la parte superior de ambas marcas de los orificios en forma de cerradura.
4. Suspenda la cubierta con los clavos e introduzca los clavos completamente. Para asegurar un montaje sin ruido, coloque otro clavo en el orificio superior de cada aleta de montaje.
INSTALL THE HOUSING (continued)
NEG
NEG
BLC
BLC TRA
UNIDAD
CAJA DE
INTERRUPTOR
INTER-
RUPTOR
ENCENDIDO/
APAGADO
LÍNEA
DE
ENTRADA
NEG
BLC TRA
M
Existing Construction
1. Choose the location for your fan in the ceiling. For best possible perfor­mance, use the shortest possible duct run and a minimum number of elbows.
2. In attic, position mounting brackets against joist. Trace outline of hous­ing on ceiling material.
3. Set housing aside and cut ceiling opening slightly larger than marked.
4. Place housing in opening so that its bottom edge is flush with fin­ished ceiling. Nail to joist through keyhole on both sides. T o ensure a noise-free installation, drive another nail through the top hole of each mounting bracket.
5. Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing di­rectly to joists or framing.
INSTALL THE DUCTWORK
1. Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. T op of damper/duct connector should be flush with top of housing.
2. Connect 4” round duct to damper/duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
CONNECT THE WIRING
1. Wire unit following diagram. Run electrical cable as direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
ATTACH THE GRILLE
1. Squeeze grille springs together and insert springs into slots in motor plate.
2. Push grille up against ceiling.
ON / OFF
SWITCH
BLK
BLK
M
WHT
ADDITIONAL MOUNTING HOLES
ORIFICIOS DE MONTAJE ADICIONALES
FLUSH AL RAS
INST ALACIÓN DE LA CUBIERTA (continuación)
Construcción existente
1. Seleccione la ubicación del ventilador en el cielo raso. Para obtener el mejor rendimiento posible, utilice un tramo de conductos lo más corto posible y un número mínimo de codos.
2. En el entretecho, coloque las abrazaderas de montaje contra la vigueta. Trace el perímetro de la cubierta en el material del techo.
3. Coloque la cubierta a un lado y haga una abertura en el techo ligeramente más grande que el perímetro marcado.
4. Coloque la cubierta en la abertura de manera que su borde inferior quede al ras del cielo raso terminado. Clave la cubierta en la vigueta a través del orificio en forma de cerradura, en ambos lados. Para asegurar un montaje sin ruido, coloque otro clavo en el orificio supe­rior de cada aleta de montaje.
5. En la cubierta se pueden encontrar orificios de montaje adicionales para aquellas instalaciones en las que es inconveniente o imposible el acceso desde arriba. Clave o atornille la cubierta directamente en las viguetas o el armazón.
INST ALACIÓN DEL SISTEMA DE CONDUCTOS
1. Conecte a presión el conector del regulador de tiro/conducto en la cubierta. Asegúrese de que las aletas del conector queden fijas en las ranuras de la cubierta. La parte superior del conector del regulador de tiro/conducto debe quedar al ras de la parte superior de la cubierta.
2. Conecte el conducto redondo de 4” (10.2 cm) en el conector del regulador de tiro/conducto y extienda el conducto hasta el exterior a través de una tapa de techo o de pared. Revise el regulador de tiro para asegurarse de que abre libremente. Coloque cinta en todas las conexiones de los conductos para asegurarlas y hacerlas herméticas
CONEXIÓN ELÉCTRICA
1. Conecte la unidad con este diagrama. Extienda el cable eléctrico a la unidad tan directamente como sea posible. No permita que el cable toque los costados ni la parte superior de la unidad después de que la instalación esté terminada.
CONEXIÓN DE LA REJILLA
1. Apriete los resortes de la rejilla y métalos en la place del motor.
2. Presione la rejilla contra el cielo raso.
BLK
LINE
WHT
IN
GRD
SWITCH BOX
ON / OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHT GRD
BLACK WHITE GROUND
(bare)
WIRING
PLATE
UNIT
RECEPTACLE
INTERRUPTOR
ENCENDIDO /
APAGADO
(se vende por
separado)
CAJA DE INTERRUPTOR
LÍNEA DE ENTRADA
DE 120 VCA
NEGRO BLANCO TIERRA
(desnudo)
PLACA
DE CONEXIONES
RECEPTÁCULO
3
USE AND CARE
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SER­VICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
CLEANING
TO CLEAN GRILLE: CAUTION: Grille can be cleaned with mild, soapy water (use a mild detergent, such
as dishwashing liquid) and dried with a soft cloth. Do not use abrasive cloth, steel wool pads, or scouring powders.
TO CLEAN FAN ASSEMBLY:
Unplug fan assembly. To remove motor plate: Find the single tab on the motor plate (located next to the receptacle). Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
SERVICE P ARTS/PIEZAS DE SERVICIO
KEY PART NO.
o
. CLAVE No.PIEZA DESCRIPTION/DESCRIPCIÓN
N
INSTRUCCIONES DE OPERACIÓN Y LIMPIEZA
ADVERTENCIA: ANTES DE LIMPIAR O DAR SERVICIO ESTA UNIDAD, DESCO­NECTE EL SUMINISTRO DE ENERGÍA Y BLOQUEE EL PANEL DE SERVICIO .
LUBRICACIÓN DEL MOTOR
El motor está permanentemente lubricado. No lubrique ni desmonte el motor.
LIMPIEZA PARA LIMPIAR LA REJILLA:
PRECAUCIÓN: La rejilla se pueden limpiar con una solución suave de agua y jabón (use un detergente suave, como por ejemplo líquido para lavar vajilla) y séquelas con un paño suave. No use tela abrasiva, almohadillas de estropajo de acero ni polvos desengrasadores.
PARA LIMPIAR EL CONJUNTO DEL VENTILADOR:
Desenchufe el conjunto del ventilador. Para quitar la placa del motor: Localice la aleta de la placa del motor (se encuentra junto a el receptáculo). Empuje hacia arriba la aleta de la placa del motor mientras empuja hacia afuera el costado de la cubierta. O bien, introduzca un destornillador de punta recta en la ranura de la cubierta (junto a la aleta) y haga girar el destornillador. Con una aspiradora limpie suavemente el ventilador , e motor y el interior de la cubierta. NUNCA DEBE SUMERGIR EN AGUA LAS PIEZAS METÁLICAS NI LAS ELÉC­TRICAS.
1 97011308 Grille/Rejilla 2 97014926 Motor Plate/Placa del motor 3 99080519 Motor (HD50)
99080520 Motor (HD80) 4 99020276 Impeller/Pistón impulsor 5 99260425 Motor Nut (2 req.)/Tuerca del motor (se req. 2)
97015161 Blower Assembly (HD50) (includes Key Nos. 2 thru 5)
*
97015162 Blower Assembly (HD80) (includes Key Nos. 2 thru 5)
*
Conjunto del ventilador (HD50) (incluye Clave Nos. 2 de a 5)
Conjunto del ventilador (HD80) (incluye Clave Nos. 2 de a 5) 6 99270982 Receptacle/Receptáculo 7 98009611 Wire Panel/Panel del cableado
97015170 Wire Panel Assembly (includes Key Nos. 6 & 7)/
*
Conjunto del panel de cableado (incluye Clave No. 6 & 7) 8 97014922 Housing/Cubierta 9 97003932 Damper/Duct Connector/Conector del regulador
10 98008868 Wiring Plate/Placa de conexiones
de tiro/conducto
1
11 99150575 Screw, #8-18 x .375/Tornillo, #8-18 x .375
12 99150471 Ground Screw/Tornillo de la tierra
Not shown assembled.
* Order replacement parts by “PART NO.” - not by “KEY NO.”
No ilustrado ensamblado.
* Pida piezas de servicio dando como referencia el
o
N
. DE PIEZA, no el No. DE CLAVE.
Broan-NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecerán de defectos en materiales o en mano de obra por un período de un año a partir de la fecha original de compra. NO EXISTEN OTRAS GARANTIAS, EXPLICITAS O IMPLICITAS, INCLUYENDO, PERO NO LIMITADAS A, GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR.
Durante el período de un año, y a su propio criterio, Broan-NuTone reparará o reemplazará, sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.
ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES. Esta garantía no cubre (a) mantenimiento y servicio normales o (b) cualquier producto o piezas que
hayan sido utilizadas de forma errónea, negligente, que hayan causado un accidente, o que hayan sido reparadas o mantenidas inapropiadamente (por otras compañías que no sean Broan-NuTone), instalación defectuosa, o instalación contraria a las instrucciones de instalación recomendadas.
La duración de cualquier garantía implícita se limita a un período de un año como se especifica en la garantía expresa. Algunos estados no permiten limitaciones en cuanto al tiempo de expiración de una garantía implícita, por lo que la limitación antes mencionada puede no aplicarse a usted.
LA OBLIGACION DE BROAN-NUTONE DE REPARAR O REEMPLAZAR, SIGUIENDO EL CRITERIO DE BROAN-NUTONE, DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA. BROAN-NUTONE NO SERA RESPONSABLE POR DAÑOS INCIDENTALES, CONSIGUIENTES, O POR DAÑOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPEÑO DEL PRODUCTO. Algunos estados no permiten la exclusión o limitación de daños incidentales o consiguientes, por lo que la limitación antes mencionada puede no aplicarse a usted.
Esta garantía le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores.
Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio que se menciona abajo o al teléfono:1-800-637-1453, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza. En el momento de solicitar servicio cubierto por la garantía, usted debe de presentar evidencia de la fecha original de compra.
Broan-NuTone LLC, 926 West State Street Hartford, WI 53027 (1-800-637-1453)
GARANTIA BROAN-NUTONE LIMITADA POR UN AÑO
9
12
10
11
7
6
2
8
4
3
5
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP START­ERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN­NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLU­SIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAM­AGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1800­637-1453)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
99042899D