Broan BPDP130SS ADA HIGH VOLTAGE WIRING INSTRUCTIONS

ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR DOUBLE BLOWER RANGE HOODS WITH
!
ROCKER SWITCH CONTROL
WARNING
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Also, it is recommended to wear safety glasses and gloves.
ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS
Remove both filters from the hood and set them aside. Remove both side fillers by removing the 3 screws holding each
one of them. Slide each one towards the center of the hood and tilt it up to remove it completely. Set the fillers and screws aside.
d
c
Using a 11/32” nutdriver or socket, remove both lock nuts
retaining the flange of each blower cover plate (shaded parts on illustration at right) to the inner back of hood (see insets). Remove all cover plate retaining screws (10 screws), then set both blower covers along with their screws and nut aside.
Locate the small plates on both left and right inner side ot the
hood (shaded part in illustration below). Use thin sheet metal snips to split these plates.
CAUTION
Be careful not to kink the range hood side panels while splitting the plates.
NOTES: 1. The plates are for shipping purpose only, there is no need to reinstall them.
2. Blower not shown on illustration to ease understanding.
HR0213
Remove and set aside the 4 front screws retaining the inner front
plate to the hood.
Screw locations
45
10
3
6
HD1103
9
8
LOCK NUTS
HO0280
BACK OF HOOD
1
7
2
Fold back the inner front plate to access to the hood control
connections. Carefully cut-off the tie wrap retaining wires together.
TIE WRAP
1
HD1104
99045893B
WIRING PROCEDURES
TO HOOD
2-ROCKER
SWITCH
WHITE
GROUND
14/3 CABLE
RED
(motor)
BLACK (lights)
GROUND
WHITE
WHITE
120 VAC
LINE IN
TO HOOD
14/3 CABLE
BLACK
2-ROCKER
SWITCH
RED
(motor)
BLACK (lights)
CAUTION
Use standard switches that are rated 120 VAC, 15 A. Only use wires suitable for at least 90C (194F). Ensure the wires are reliably routed away from the halogen lights (if present).
To suit your needs, there are 2 ways to wire a 2-rocker switch control to these range hoods: 120 VAC power cable entering the range hood or 120 VAC power cable entering the switch box.
120 VAC POWER CABLE ENTERING THE HOOD
Install a 2-rocker switch at a convenient place for the user. Use a 14/3 cable to wire it to the range hood (see diagram at right).
NOTE: The code requires both ends of the WHITE wire insulation to be colored; use a permanent marker.
NOTE: Allow enough length of 14/3 cable to perform the RED wire
connection in the hood nose.
Insert the 14/3 cable along with the 14/2 house wiring cable in the
hood through an UL approved wire clamp, suitable for 2 cables. Add a GROUND wire and connect one of its end to the GREEN ground screw. Use an appropriate wire nut to connect the other end of the added GROUND wire with the ground wire coming from the 14/3 cable and the ground wire coming from 14/2 house wiring cable.
Connect BLACK wire from house wiring to WHITE wire from
14/3 cable using an appropriate wire nut.
Connect BLACK wire from 14/3 cable to BLACK wire from range
hood wiring using an appropriate wire nut.
Connect WHITE wire from house wiring to WHITE wire range
hood wiring using an appropriate wire nut.
Run RED wire from 14/3 cable to top of right blower scroll. See
next page for RED wire connection.
3
4
120 VAC
HOUSE WIRING
Motor switch
Light switch
2
14/3 CABLE
5
TO CONTROL PANEL
MOTOR GROUND WIRE
1
BLACK
WHITE
RED
GROUND
120 VAC POWER CABLE ENTERING THE SWITCH
Install a 2-rocker switch at a convenient place for the user. Feed the switch box with 120 VAC house wiring and use a 14/3 cable to wire it to the range hood (see diagram at right).
NOTE: Allow enough length of 14/3 cable to perform the RED wire
connection in the hood nose.
Insert the 14/3 cable in the hood through an UL approved wire
clamp. Connect ground wire to the GREEN ground screw.
Connect WHITE wire from 14/3 cable to WHITE wire from range
hood wiring using an appropriate wire nut.
Connect BLACK wire from 14/3 cable to BLACK wire from range
hood wiring using an appropriate wire nut.
Run RED wire from 14/3 cable to top of right blower scroll. See next
page for RED wire connection.
2
3
2
Motor switch
Light switch
4
TO CONTROL PANEL
1
14/3 CABLE
MOTOR GROUND WIRE
BLACK
WHITE
RED
GROUND
RED WIRE CONNECTION
A Cut the BLACK wire that is connected to blower switch and light switch.
B Cap off the BLACK wire connected to the light switch terminal. Connect the RED wire from 14/3 cable to the BLACK wire from the motor
switch, using an appropriate wire nut.
MOTOR SWITCH
TERMINALS
A
BLACK WIRE
MOTOR SWITCH
TERMINALS
B
ROCKER SWITCHES
BPDC1 SERIES
LIGHT SWITCH
LIGHT SWITCH
RED WIRE
FROM 14/3 CABLE
TERMINALS
TERMINALS
ELONGATED ROCKER SWITCHES
BPDP1 AND NPDP1 SERIES
A
B
MOTOR SWITCH
TERMINALS
BLACK WIRE
MOTOR SWITCH
TERMINALS
RED WIRE
FROM 14/3 CABLE
LIGHT SWITCH
TERMINALS
LIGHT SWITCH
TERMINALS
Once all the connections are done, finalize the installation by reversing steps
to on first page.
RANGE HOOD OPERATION
Use the hood control to set or change the blower and light intensities desired; these settings will be applied when using the wall switches. For example, if the blower is set on high speed using the hood control, when the user presses on the motor rocker switch on the wall control, the blower will then turn on high speed. If the user wants the blower to turn on low speed, the blower speed must be changed using the hood control. It is not necessary to turn off the blower to change its speed.
The same procedure applies for the light intensities (when low and high intensities are available).
THIS PROCEDURE APPLIES TO BROAN BPDC1, BPDP1, AND NUTONE NPDP1
DOUBLE BLOWER RANGE HOOD SERIES.
3