Roomside / FlexTM Series Fan/Light
READ AND SAVE THESE INSTRUCTIONS
For Warranty Statement, Service Parts, Technical Support, or to
Register your product, please visit our website or call:
In the United States - Broan.com 800-637-1453 or NuTone.com
888-336-6151. In Canada - Broan.ca or NuTone.ca 877-896-1119
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. This product can be installed in a wall if mounted 8-ft. or more
above the floor.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further information
and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance
- lower or remove grille and vacuum interior of unit with the dusting
brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace the
blower assembly (includes motor and impeller).
OPERATION
The fan and light can be operated separately. Use a 2-function wall
control.
FlexTM Series Fan/Light ONLY: Do not use a speed control to
operate the fan.
COOKING AREA
Do not install above or
inside this area.
NOT FOR USE IN
A COOKING AREA.
IMPORTANT -
o
45
Cooking
Equipment
The ducting from this fan to the outside of the building
45
o
Floor
has a strong effect on the air flow, noise and energy use of the fan. Use
the shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve their rated airflow.
ROOF CAP* (with built-in damper)
INSULATION
(Place around and
over fan housing.)
FAN
HOUSING
POWER
CABLE *
Seal gaps
around
housing.
4-IN. ROUND
DUCT*
* Purchase separately.
Seal duct joints
with tape.
OR
4-IN. ROUND
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
OPTION - To mount housing anywhere between ceiling framing:
Use optional Hanger Bar Kit (sold separately from local distributors
or website). Follow mounting instructions included with kit.
1
ALL INSTALLATIONS
Remove all packing material, unplug
1
1
and remove blower from fan housing.
Some models only:
4
1
A pair of anges
may be attached to
housing if desired
or required.
Snap both flange pieces
under rolled-over edge of
housing (all four sides).
Remove wiring panel
2
1
from fan housing. (if
already installed).
Some models only:
3
1
Select 50, 80 or 110
CFM based on your room
size and desired
air ow.
For Retrot Installation Skip to Page 3.
50 80 110
Attach damper/duct connector to
5
1
fan housing.
Push connector
through opening
from inside of
housing.
Engage tabs
and secure with
screw from
parts bag.
TABS
NEW INSTALLATION
Mount housing to ceiling structure.
6
1
Make sure bottom of housing
will be flush with finished
ceiling.
For proper location using ½”
ceiling material: Bend out
housing tabs (on outside of
housing) to fit against bottom
of joist.
Secure housing through
mounting ears with appropriate
fasteners. If mounting housing
to I-joist, use wood blocking as
shown.
I-JOIST
WOOD
BLOCKING
HOUSING TABS
2
Connect 4-in.
7 8
round duct.
Connect power cable
to wiring plate (from
parts bag) using UL
approved connector.
Connect house wiring
to fan wiring. Refer
to wiring diagram for
connection details.
Use screw (from
parts bag) to secure
wiring plate to fan housing. Re-install wiring
panel and secure with screw from parts bag.
Connect wiring.
11
RETROFIT INSTALLATION
Finish ceiling.
9
1
Then continue with Step 10.
Remove old
5
1
fan and prepare
ceiling.
Enlarge ceiling opening (if
necessary) to 9¾” parallel to
joist) by 10½” (perpendicular
to joist). (Some models have
a cut-out template on side of
carton.)
Existing fan housings are typically attached to the structure:
with screws, nails, or staples, which must be removed.
•
with hangers or rails which are fastened to joists and must be removed along with housing.
•
A pry bar may be needed to remove the old housing.
Leave ductwork and wiring in place.
Connect wiring.
7
1
Connect power cable to wiring plate
(from parts bag) using UL approved
connector. Connect house wiring to
fan wiring. Refer to wiring diagram for
connection details. Use screw (from
parts bag) to secure wiring plate to fan
housing. Re-install wiring panel and
secure with screw from parts bag.
1
9¾-in.
10½-in.
JOIST
2
Fold mounting ears
6
1
at against housing.
Mount fan to ceiling
8
1
structure.
Mount housing to ceiling
structure with appropriate
fasteners in locations shown.
3
Connect 4-in. round duct.
9
1
Pull existing ducting through housing discharge
opening and tape ducting to duct connector. Push
connector/ducting back through opening. Engage tabs
and secure with screw from parts bag.
3
2
ALL INSTALLATIONS
TABS
1
4
Continue with Step 10.
10
11
Install blower.
1
Re-install blower removed in
Step1. Secure blower with 2
screws from parts bag. Plug
blower into black receptacle.
FlexTM Series Fan/Light
ONLY: Plug 5-wire plug into
controller module.
Install grille.
1
LED Fan/Light ONLY:
Snap LED light module
into inside of grille.
Note: On some models,
LED module may
already be installed.
Plug in light module.
Squeeze grille springs
and insert into slots in
blower. Push grille up
against ceiling.
Depending upon model - your grille may look different.
LED
Fan/Light
ONLY
FlexTM Series
Fan/Light ONLY
For models 791LEDM
and 791LEDNTM ONLY:
Plug in light and
LED driver .
1
2
2-FUNCTION CONTROL
(purchase separately)
LIGHT
FAN
SWITCH BOX
BLACK
WHITE
RED
GROUND
(bare)
WIRING PLATE
WIRING DIAGRAM
RECEPTACLE
(LIGHT)
RECEPTACLE
(FAN)
4
If grille spring
becomes dislodged
from grille - snap it
back into place as
shown.
1100262F