Braun 7899cc w&d, 7898cc w&d, 7897cc w&d User Manual

6
Series 7
Stapled booklet, 120 x 170 mm, 36 pages, 2/2c = black + cyan
90796256/III-16
Type 5696
pe 569
7899cc w&d 7898cc w&d 7897cc w&d
2345678
Series 7
Series 7
trimmer
Series 7S
eries 7
Series 7
Series 7
trimmer
trimmer
trimmer
trimmer
trimmer
trimmer
on
offonoff
wet & dry
ry
& d
wet
1
2
n
a
f
e
l
a
c
s
t
n
a
f
e
l
a
c
s
t
n
a
f
e
l
a
c
s
t
9
101112
h
y
y
g
r
i
e
e
t
t
n
a
e
b
h
y
y
g
r
i
e
e
t
t
n
a
e
b
h
y
y
g
r
i
e
e
t
t
n
a
e
b
h
y
y
g
r
i
e
e
t
t
n
a
e
b
h
y
y
g
r
i
e
e
t
t
n
a
e
b
re
r
lea se
90°
t
+
2
lock
1
mmer tri
lock
lock
lock
13
er
r
e
le
a
s
e
tr immer
t
tr immer
rimmer
Series
re le a
s e
Series
re le a
s e
Series
Series 7
Series 7
14
Series 7
Series
re le a s
e
Series 7
Series 7
Series 7
mer
old
Series 7
re le a s
e
r
e
le
a
s
e
new
15
re le a s e
70S
y
y
g
g
y
y
n
e
b
b
Series 7
/70B
y
r
e
t
t
a
b
70S/70B
h
y
g
i
e
n
e
16
1718192021
trim
mer
Series 7Se
r ies
7
Series
7
34
Series 7
Series 7
Series 7
8
9
10
5
11
12 13
trimmer
trimmer
trimmer
trimmer
trimmer
trimmer
on
on
off
off
wet & dry
2 1
6
14
7
15
16
16a 16b 16c 16d
20
h
y
y
g
r
i
e
e
t
t
n
a
e
b
17
h
y
y
g
r
e
i
e
t
t
n
a
e
b
19
y
dr
18
wet &
1
trimmer
2
n
a
f
e
l
a
c
s
t
n
a
e
f
l
a
c
t
s
n
a
f
e
l
a
c
s
t
trimmer
Series 7
22
n
a
e
f
l
a
c
t
s
n
a
e
f
l
a
c
t
s
trimmer
re
le
a
s
e
rim
tr
Series 7
2
1
+
trimmer
lock
lock
lock
release
lock
90°
trimmer
Series
re
le
a
s
e
mer
Series
re
le
a
s
e
mer
Series
Series 7
Series 7
Series
re
le
a
s
e
mer
Series 7
Series 7
Series 7
Series 7
re
le
a
s
re
le
a
s
e
e
23
English
Our products are designed to meet the highest standards of quality, functionality and design. We hope you enjoy your new Braun Shaver.
Read these instructions completely, they contain safety information. Keep them for future reference.
Warning
Your shaving system is provided with a special cord set, which has an integrated Safety Extra Low Voltage power supply. Do not exchange or tamper with any part of it, otherwise there is risk of an electric shock. Only use the special cord set provided with your appliance.
If the appliance is marked 492, you can use it with any Braun power supply coded 492-XXXX.
Do not shave with a damaged foil or cord. This appliance is suitable for cleaning under running water
and use in a bath or shower. For safety reasons it can only
be operated cordless.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given super­vision or instruction concerning the safe use of the appliance and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children unless they are older than 8 years and supervised.
To prevent the cleaning fluid from leaking, ensure that the Clean&Renew station is placed on a flat surface. When a cleaning cartridge is installed, do not tip, move suddenly or transport the station in any way as cleaning fluid might spill out of the cartridge. Do not place the station inside a mirror cabinet, nor over a radiator, nor place it on a polished or lacquered surface.
The cleaning cartridge contains a highly flammable liquid so keep it away from sources of ignition. Do not smoke near the station. Do not expose to direct sunlight for long periods of time.
Do not refill the cartridge and use only original Braun refill cartridges.
24
Description
Clean&Renew station 1 Cleaning fluid display
2 Lift button for cartridge exchange 3 Station-to-shaver contacts 4 Start button 5 Cleaning program indicators 6 Station power socket 7 Cleaning cartridge
Shaver 8 Foil & Cutter cassette
9 Cassette release button 10 Shaver head lock switch 11 Pop-out long hair trimmer
12 On/off switch 13 – setting button (sensitive) 14 + setting button (intensive) 15 Reset button 16 Shaver display 16a Battery segments 16b Hygiene segments 16c Low charge indicator 16d Replacement symbol 17 Shaver-to-station contacts 18 Shaver power socket 19 Travel case 20 Special cord set (design can differ)
Before shaving
Prior to first use you must connect the shaver to an electrical outlet using the special cord set (20) or alternatively proceed as below.
Installing the Clean&Renew station
Press the lift button (2) to open the housing.
Hold the cleaning cartridge (7) down on a flat, stable surface (e.g. table).
Carefully remove the lid from the cartridge.
Slide the cartridge into the base of the station as far as it will go.
Slowly close the housing by pushing it down until it locks.
Using the special cord set (20), connect the station power socket (6) to an electrical
outlet.
The cleaning fluid display (1) will show how much fluid is in the cartridge:
up to 30 cleaning cycles available up to 7 cleaning cycles remaining new cartridge required
Charging and cleaning the shaver
Insert the shaver head with the front showing and released head lock (10) into the Clean&Renew. The contacts (17) on the back of the shaver will align with the contacts (3) in the cleaning station. Important: The shaver needs to be dry and free from any
foam or soap residue!
If required, the Clean&Renew station will automatically charge the shaver. The hygiene status of the shaver will also be analyzed and one of the following cleaning program indicators (5) will light up:
25
shaver is clean short economical cleaning required
normal level of cleaning required
high intensive cleaning required
If the station selects one of the required cleaning programs, it will not start unless you press the start button (4). For best shaving results, we recommend cleaning after
each shave.
Each cleaning program consists of several cycles, where cleaning fluid is flushed through the shaver head. Depending on your Clean&Renew Station model and/or program selected, the cleaning time takes up to 16 minutes. Leave the shaver in the station for drying. It takes several hours until remaining moisture evaporates depending on the climatic conditions.
When the program is finished, the blue
Stand-by mode
10 minutes after completing the charging or cleaning session, the Clean&Renew station switches to the stand-by mode: The indicators of the Clean&Renew station turn off.
indicator will light up.
Shaver display
The shaver display (16) shows the charge status of the battery on the left, and the hygiene status on the right. 6 dark segments are shown on each side when the battery is fully charged and the shaver is hygienically clean.
Battery segments:
During charging or when using the shaver, the respective battery segment (16a) will blink. When fully charged all 6 segments are shown. With decreasing charge the segments gradually disappear.
Low charge indicator The low charge indicator (16c) provided with a red frame blinks to indicate that the battery is running low. The remaining battery capacity is sufficient for 2 to 3 shaves.
Hygiene segments:
All 6 hygiene segments (16b) will appear after the shaver has been cleaned in the Clean&Renew station. When the shaver is being used, the hygiene segments will gradually disappear. Once the shaver is returned to the station, the system will automatically select the appropriate cleaning program and restore the segments to maximum hygiene. Given that rinsing the shaver under tap water is not as hygienic as the cleaning station, the hygiene segments will only restore themselves when the shaver has been cleaned in the Clean&Renew station.
Charging information
A full charge will take about 1 hour and provides up to 50 minutes of cordless shaving time. This may vary according to your beard growth and environmental temperature. 5-minute quick charge is sufficient for a shave.
26
Recommended ambient temperature for charging is 5 °C to 35 °C. The battery may not charge properly or at all under extreme low or high temperatures. Recommended ambient temperature for shaving is 15 °C to 35 °C. Do not expose the shaver to temperatures higher than 50 °C for extended periods of time.
Using the shaver
How to use
Press the on/off switch (12) to operate the shaver:
The pivoting shaver head and floating foils automatically adjust to every contour of your face.
To shave hard to reach areas (e.g. under the nose), first slide the shaver head to the back position, afterwards move the head lock switch to the back. The pivoting head is locked at this angle.
To trim sideburns, moustache or beard, slide the pop-out long hair trimmer (11) upwards.
Tips for the perfect dry shave
For best shaving results, Braun recommends you follow 3 simple steps:
1. Always shave before washing your face.
2. At all times, hold the shaver at right angles (90°) to your skin.
3. Stretch your skin and shave against the direction of your beard growth.
Personalizing your shaver
By holding down the accelerator button –/+ (13) or (14) power to your individual needs in the different areas of your face from sensitive to intensive. The pilot light in the on/off switch ( 12 ) changes within the following range:
(–) sensitive shave
- light blue
- dark blue
- green
(+) intensive shave
For a thorough and fast shave we recommend the green (intensive) setting. When switching on next time, the last used setting will be activated.
you can adjust the shaving
Cleaning
Automatic cleaning
After each shave, return the shaver to the Clean&Renew station and proceed as described above in the section «Before shaving». All charging and cleaning needs are then automatically taken care of. With daily use, a cleaning cartridge should be sufficient for about 30 cleaning cycles.
The hygienic cleaning cartridge contains ethanol or isopropanol (specification see cartridge), which once opened will naturally evaporate slowly. Each cartridge, if not used daily, should be replaced after approximately 8 weeks to ensure optimal disinfection.
27
The cleaning cartridge also contains lubricants, which may leave residual marks on the outer foil frame after cleaning. However, these marks can be removed easily by wiping gently with a cloth or soft tissue paper.
Manual cleaning
Cleaning under running water:
Switch the shaver on (cordless) and rinse the shaver head under hot running water until all residues have been removed. You may use liquid soap without
abrasive substances. Rinse off all foam and let the shaver run for a few more seconds.
Next, switch off the shaver, press the release button (9) to remove the Foil & Cutter cassette (8) and let it dry.
If you regularly clean the shaver under water, then once a week apply a drop of light machine oil (not included) on top of the Foil & Cutter cassette and the long hair trimmer.
The shaver should be cleaned after each foam usage.
Cleaning with a brush:
Switch off the shaver. Remove the Foil & Cutter cassette (8) and tap it out on a flat surface. Using a brush, clean the inner area of the pivoting head. However, do not clean the cassette with the brush as this may damage it.
Cleaning the housing
From time to time clean the housing of the shaver and the Clean&Renew station with a damp cloth, especially inside the cleaning chamber where the shaver rests.
Replacing the cleaning cartridge
After having pressed the lift button (2) to open the housing, wait for a few seconds before removing the used cartridge to avoid any dripping. Before discarding the used cartridge, make sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning solution.
Keeping your shaver in top shape
Replacing the Foil & Cutter cassette / reset
To maintain 100% shaving performance, replace the Foil & Cutter cassette (8), when the replace ment symbol (16d) lights up on the shaver display (after about 18 months) or when cassette is worn. The replacement symbol will remind you during the next 7 shaves to replace the Foil & Cutter cassette. Then the shaver will automatically reset the display.
After you have replaced the Foil & Cutter cassette, use a ball-pen to push the reset button (15) for at least 3 seconds to reset the counter. While doing so, the replacement light blinks and goes off when the reset is complete. The manual reset can be done at any time.
28
Accessories
Available at your dealer or Braun Service Centres:
Foil & Cutter cassette 70S/70B
Cleaning cartridge Clean&Renew CCR
Environmental notice
Product contains batteries and/or recyclable electric waste. For environment protection do not dispose of in household waste, but for recycling take to electric waste collection points provided in your country.
The cleaning cartridge can be disposed with regular household waste.
Subject to change without notice.
For electric specifications, see printing on the special cord set.
Trouble-Shooting
Problem: Possible reason: Remedy:
SHAVER
Unpleasant smell from the shaver head.
Battery performance dropped significantly.
Shaving performance dropped significantly.
1. Shaver head is cleaned with water.
2. Cleaning cartridge is in use for more than 8 weeks.
1. Foil and cutter are worn which requires more power for each shave.
2.
Shaver head is regularly
cleaned with lubricated.
1. Foil and cutter are worn.
2. Personal setting of shaving performance has been changed.
3. Shaving system is clogged.
water but not
1. When cleaning the shaver head with water only use hot water and from time to time some liquid soap (without abrasive substances). Remove Foil & Cutter cassette to let it dry.
2. Change cleaning cartridge at least every 8 weeks.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned with water, apply a drop of light machine oil on top of the foil once a week for lubrication.
1. Renew Foil & Cutter cassette.
2. For a thorough and fast shave we recommend the green (intensive) setting.
3. Soak the Foil & Cutter cassette into hot water with a drop of dish liquid. Afterwards rinse it properly and tap it out. Once dry apply a drop of light machine oil on the foil.
29
Shaver turns off with fully charged battery.
Battery segments in the display are skipped with decreasing battery capacity.
Shaving parts have been changed recently but replacement symbol lights up.
Shaver head is damp.
CLEAN&RENEW STATION
Cleaning does not start when pressing the start button.
Increased consumption of cleaning fluid.
Foil and cutter are worn which requires more power than the motor can deliver. The appliance turns off.
Foil and cutter are worn which requires more power for each shave.
Reset button has not been pushed.
1. Drying time after automatic cleaning was too short.
2. Drain of the Clean&Renew station is clogged.
3. Cleaning cartridge has been used for quite a while.
1. Shaver is not placed properly in the Clean&Renew station.
2. Cleaning cartridge contains not enough cleaning fluid (display lights red).
3. Appliance is in stand-by mode.
Drain of the Clean&Renew station is clogged.
– Renew Foil & Cutter cassette. – Regularly oil the shaving system,
especially when cleaning with water only.
– Renew Foil & Cutter cassette. – Regularly oil the shaving system,
especially when cleaning with water only.
– Push the reset button for at least 3
seconds to reset the counter.
1. Clean directly after shaving to allow enough time for drying.
2. Clean the drain with a wooden toothpick. Regularly wipe the tub clean.
3. The ethanol/isopropanol proportion has decreased while the oil proportion has increased. Remove residue with a cloth.
1. Insert shaver into the Clean&Renew station (contacts of the shaver need to align with contacts in the station).
2. Insert new cleaning cartridge.
3. Press start button again.
– Clean the drain with a wooden
toothpick.
– Regularly wipe the tub clean.
30
Series 7
Loading...