Braun 7785, 5492, 7765, 7790 User Manual

Page 1
7790 7785
7765
Type 5492 Type 5493
k
c
t
u
321
a
0
9
7
7
o
r
P
o
r
h
c
n
o
l
c
i
t
a
m
Syncro Pro
y
S
www.braun.com/register
Page 2
SyncroPro 7790
k
c
o
l
c
i
t
a
m
o
t
u
a
321
7000
SyncroPro 7785 SyncroPro 7765
k
c
o
l
c
i
t
a
m
o
t
u
a
321
5
8
7
7
o
r
P
o
r
h
c
n
y
S
0
9
7
7
o
r
P
o
r
h
c
n
y
S
Page 3
7790
210
+35°C
+15°C
3
Page 4
21
21
1
2
3
0..20 40 60 80 100
0..20 40 60 80
k
c
o
l
c
i
t
a
m
o
t
u
a
+
4
Page 5
10
10
oil
Syncro
7000
7000
5
Page 6
7XXX
1
2
3
5 6
4
6
Page 7
English
210
7
+35°C
+15°C
Our products are designed to meet the highest standards of quality, functionality and design. We hope you enjoy your new Braun shaver. Braun Syncro 7790 and 7785 are supplied with a Braun Clean&Renew™ (please see separate use instructions).
SmartLogic
The « SmartLogic » electronics inside your shaver analyzes your personal shaving patterns, and then adapts the battery care to ensure optimal performance.
Warning
Keep the appliance dry. Your shaver is provided with a special cord set with an integrated Safety Extra Low Voltage power supply. Do not exchange or manipulate any part of it. Otherwise there is risk of electric shock.
Description
1 Foil protection cap 7 Charging lights (green) 2 Shaver foil 8 Low-charge light (red) 3 Cutter block 9 Pilot light 4 Foil release button 10 Shaver socket 5 Long hair trimmer 11 Special cord set 6 Switch
Charging the shaver
7790
First charging: Using the special cord set, connect the shaver to an electrical outlet with the switch on position «0» and charge it for at least 4 hours (plug might get warm). The SmartLogic inside your shaver automatically monitors the condition of the batteries as well as the charging/dis­charging processes and adapts them to your personal shaving patterns.
From now on, the SmartLogic inside your shaver will ensure optimal care of the battery. If, for instance, it is your habit to never let the batteries get low, the SmartLogic will recognize this, look for a pause when you are likely to not use the shaver and completely discharge and then recharge your shaver to recondition the batteries (every six months at the most, and only when necessary).
A full charge will give up to 50 minutes of cordless shaving time depending on your beard growth. However, the maximum battery capacity will only be reached after several charging/discharging cycles.
Best environmental temperature range for charging is 15 °C to 35 °C.
Page 8
Do not expose the shaver to temperatures of more than 50 °C for longer periods of time.
Indicator lights
The pilot light shows that the shaver is connected to the mains.
7790:
When the rechargeable battery is fully charged, all five charging lights illuminate (20% per light), provided the shaver is connected to the mains or switched on.
21
21
1
2
3
0..20 40 60 80 100
0..20 40 60 80
k
c
o
l
c
i
t
a
m
o
t
u
a
7785/7765:
+
is being charged. When the rechargeable battery is fully charged, the charging light flashes or goes off.
The green charging light shows that the shaver
If later on, the charging light comes on again, this indicates that the shaver is being recharged to maintain its full capacity.
7790/7785/7765:
The red low-charge light flashes when the battery capacity has dropped below 20%, provided the shaver is switched on. The remaining capacity will then be sufficient for 2 to 3 shaves.
Shaving
Switch positions
0 = Off (switch is locked)
Press and push up the switch to operate the shaver:
1 = Shaving with the pivoting head
The pivoting cutting system automatically adjusts to every contour of your face
2 = Shaving with the pivoting head locked at an angle
(to permit shaving in difficult areas, e.g. under the nose)
3 = The long hair trimmer is activated
(for trimming sideburns, moustache and beard).
Shaving with the cord
If the rechargeable batteries are discharged, you may also shave with the shaver connected to an electrical outlets via the special cord set. (If the shaver does not run immediately, charge it with the switch on position «0» for approx. 1 minute.)
8
Page 9
Tips for the perfect shave
We recommend that you shave before washing, as the skin tends to be slightly swollen after washing.
Hold the shaver at right angles (90°) to the skin.
Stretch your skin and shave against the direction of beard growth.
• To maintain 100% shaving performance, replace your foil and cutter block at least every 18 months or when worn.
Keeping your shaver in top shape
Automated cleaning
The Braun Clean&Renew™ (with 7790 and 7785 models only) automatically takes care of all cleaning and lubrication needs of your shaver. Please refer to separate use instructions.
Manual cleaning
For easy cleaning after each shave, switch the shaver off. Press the release buttons to lift the shaver foil (do not remove the foil completely).
10
for approx. 5-10 seconds so that the shaved stubbles can fall out.
For a thorough cleaning (weekly), remove the shaver foil and tap it out on a flat surface. Using the brush, clean the cutter block and the inner area of the pivoting head. About every four weeks, clean the cutter block
10
oil
with Braun cleaning agents.
If your skin is very dry and you notice a reduced operation time of the shaver, apply a drop of light machine oil onto the shaver foil.
Switch on the shaver
9
Page 10
1
7XXX
3
5 6
Replacing the shaving parts
Syncro
To maintain 100% shaving performance, replace your foil and cutter block at least every 18 months or when worn. Change both parts at the same time for a closer
7000
7000
shave with less skin irritation. (Shaver foil and cutter block: 7000 series)
Environmental notice
2
4
This appliance is provided with nickel-hydride recharge­able batteries. To protect the environment, do not dis­pose of the appliance in the household waste at the end of its useful life. Open the housing as shown, remove and dispose of the batteries at your retail store or at appropriate collection sites according to national or local regulations.
Subject to change without notice.
This product conforms to the European Directives EMC 89/336/EEC and Low Voltage 73/23/EEC.
For electric specifications, see printing on the special cord set.
Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at a Braun Service Centre or at appropriate collection points provided in your country.
10
Page 11
TM
Clean&Renew
Type 5301
Page 12
A
3
2
4
select
clean
charge
1
cartridge
6
7
8
5
Page 13
B
7790
C
7790
3
2
1 0
7790
2
1
new
3
a
u
t
o
m
a
t
i
c
l
o
c
k
on/off
clean
charge
2
cartridge
1 0
7790
3
select
new
old
7790
select
select
clean
charge
cartridge
Page 14
141516
Page 15
Page 16
Braun Clean&Renew™ has been developed for cleaning, charging and storing your shaver. Clean your shaver daily in the Clean&Renew™. During the automated cleaning process, the shaver is switched on and off at intervals to obtain best cleaning results. Since the specially formulated cleaning fluid contains a small amount of oil, the cleaning procedure also fulfills the lubrication needs of the shaver.
Important
Only use the low voltage adaptation system
supplied with the shaver.
In order to avoid any leakage of the cleaning fluid, place the appliance on a flat, stable surface or use the wall holder (not included in all versions). Do not tip, move suddenly or transport in any way if a cleaning cartridge is installed.
Do not place the appliance in a mirror cabi­net, nor store it over radiators, nor place it on polished or laquered surfaces. Do not expose to direct sunlight.
The appliance contains highly flammable liquid. Keep it away from sources of ignition. No smoking. Keep out of reach of children. Do not refill cartridge. Use only original Braun refill cartridge.
When cleaning the shaver, its protection cap should be removed.
A Description
1 Lift button for cartridge exchange 2 Contact bow 3 Release button 4 Operation mode selector 5 «clean» light:
cleaning process indicator
6 «charge» light:
charging process indicator
7 «cartridge» light:
cartridge replacement indicator
8 Cleaning cartridge
Wall holder (not included in all versions)
Mount the wall holder with plugs and screws to a smooth wall so that the standing surface for the Clean&Renew™ is horizontal.
Technical specifications
Power consumption:
3 W when cleaning 7 W when charging
Power supply: 100-240 V 2/ 50 or 60 Hz (automatic adaptation)
Input voltage: 12 V
B Before using Clean&Renew™
Only applies for cordless shavers:
For the first charge of the shaver, connect the low voltage supply cord directly to the shaver, charge it for 4 hours and shave at least once. Only then can the shaver be cleaned or recharged in the Clean&Renew™.
If the rechargeable battery is discharged, select the combined «clean» + «charge» programme rather than the «clean» programme alone.
Installing the cartridge
Press the lift button (1) to open the housing.
Hold the cartridge down on a flat, stable surface (e.g. table). Carefully remove the lid from the cartridge. Slide the cartridge into the base as far as it will go.
Slowly close the housing by pushing it down until it locks.
Replacing the cartridge
After having pressed the lift button to open the housing, wait for a few seconds before removing the used cartridge.
Page 17
Before discarding the used sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning solution.
cartridge, make
C Operating your Clean&Renew™
Connect your Clean&Renew™ with the low
voltage supply cord to the mains electricity supply. Open the contact bow (2) by pressing the release button (3). After shaving, switch the shaver off and place it upside down into the Clean&Renew™ (without having released the shaver foil).
Select the operation mode by toggling with the mode selector (4): «clean» (about 15 min) «clean» + «charge» (about 75 min) «charge» (about 60 min) The corresponding lights will come on. (With cord shavers, only the «clean» function can be selected.)
Slide down the contact bow to connect the shaver and to start the selected programme. If no programme is selected, the default function «clean» will be started.
Do not interrupt a running programme, as it leaves the shaver wet and not fit for use. If interruption is needed nonetheless, press the release button.
After a programme has finished, the corre­sponding light will go out. Prior to the next shave, press the release button to release the shaver.
When the «cartridge» light starts flashing, the remaining fluid in the cartridge is sufficient for about 5 more cleaning cycles. After these 5 cycles, the cleaning performance will be reduced and the cartridge has to be replaced.
When the «cartridge» light illuminates constantly, the cleaning function is locked and a new cartridge has to be installed. Only then, the next cleaning cycle can be started.
A cleaning cartridge should be sufficient for about 30 cleaning cycles. With daily use, the cleaning cartridge should be replaced approx. every 4 weeks.
The hygienic cleaning solution cartridge contains alcohol which, once opened, will naturally evaporate slowly into the surround­ing air. Each cartridge, if not used daily, should be replaced after approx. 8 weeks.
Clean the housing from time to time with a damp cloth, especially the opening where the shaver rests.
Subject to change without notice.
This product conforms to the European Directives EMC 89/336/EEC and Low Voltage 73/23/EEC.
For electric specifications, see printing on the special cord set.
Please do not dispose of the product in the household waste at the end of its useful life. Disposal can take place at a Braun Service Centre or at appropriate collection points provided in your country.
17
Page 18
5-492-447/01/VI-07 Korea/GB
Loading...