Braeburn 1220NC User Manual

0 (0)

®

Non-Programmable

Thermostats

Detailed

Installer Guide

1020NC

1220NC

Single Stage Heat / Cool Conventional and Heat Pump

Up to 2 Heat / 1 Cool Conventional and Heat Pump

Model number is located on back of thermostat

1

Specifications

5

Setting User Options

2

About Your Thermostat

6

Operating Your Thermostat

3

Installation

7

Additional Operation Features

4

System Testing

8

Thermostat Maintenance

Warning Turn off power to the heating or cooling equipment before installation.

Attention For installation by experienced service technicians only.

Read all instructions before proceeding.

This thermostat requires 24 Volt AC Power or two (2) properly installed “AA” Alkaline batteries for proper operation. When connecting 24 Volt AC Power the batteries may be installed as a backup.

For use only as described in this manual. Any other use will void warranty.

1 Specifications

This thermostat is compatible with:

Single stage heat / cool conventional and heat pump systems

Conventional systems up to 2 heat / 1 cool (1220NC only)

Single compressor heat pump systems with an auxiliary heat stage (1220NC only)

250 – 750 millivolt heat only systems

Electrical and control specifications:

Electrical Rating: 24 Volt AC

1 amp maximum load per terminal

AC Power: 18 – 30 Volts AC

DC Power: 3.0 Volt DC (2 “AA” Alkaline Batteries Included)

Control Range: 45° – 90° F (7° – 32° C)

Temperature Accuracy: +/- 1° F (+/- .5° C)

Terminations

• 1020NC

– Rc, Rh, O, B, Y1, W1, G, C

 

• 1220NC

– Rc, Rh, O, B, Y1, E/W1, G, W2, C

1020NCW-100-03

Braeburn 1220NC User Manual

2 About Your Thermostat

 

5

1

6

 

 

7

2

8

3

9

4

10

1

Room Temperature...........

Displays. the current room temperature

2

Reset Button.......................

Resets thermostat back to factory defaults

3

Low Battery Indicator.......

Indicates.

when the batteries need to

 

 

be replaced

4

System Switch...................

Selects System Preference

5

Quick Reference

 

 

 

 

Instructions........................

Stored in slot at top of thermostat

6

Fan Indicator.....................

Indicates.

when the system fan is running

7

System Status Indicator....

Displays information about the status of

 

 

the system

8

Arrow Buttons...................

Used. to increase or decrease settings

9

Set Temperature.................

Displays the current set point temperature

10

Fan Switch.........................

Selects the system fan mode

 

Battery Compartment.......

Located.

in the back of the thermostat

3 Installation

Warning Disconnect power before beginning installation.

Thermostat Location

Install the thermostat approximately 5 feet (1.5m) above the floor in an area that has a good amount of air circulation and maintains an average room temperature.

Avoid installation in locations where the thermostat can be affected by drafts, dead air spots, hot or cold air ducts, sunlight, appliances, concealed pipes, chimneys and outside walls.

1

Install your new Braeburn thermostat in 5 basic steps:

1Install the Sub-Base

2Provide Power

3Connect Your Wires 4 Set Installer Switches

5Attach Thermostat to Sub-Base

1Install the Sub-Base:

Remove the sub-base from the body of the thermostat.

Mount the sub-base as shown below:

Drill 3/16” pilot holes in your desired location. Use supplied anchors for drywall or plaster.

UP

UP

NOTE: After sub-base installation, you may insert the quick reference card into the slot on the top of the base.

2 Provide Power

24VAC Power Terminal (C)

C

For 24 Volt AC power, you must connect the common side of the transformer to the C terminal on the thermostat sub-base.

For primary or back-up power, insert the 2 supplied “AA” type alkaline batteries into the battery compartment located in the rear housing of the thermostat. Make sure to position the Positive (+) and Negative (-) sides of the batteries correctly with the +/- symbols in the battery compartment.

2

Loading...
+ 7 hidden pages