Test le fonctionnement des v
signe en bas. S'il y à quelqu
un rappor
Date
Datum
Date
114-051
PRÜFEN.
Testbetrieb prüfen,
he Störung sofor
Signed
Unterschrift
below.
bestätigt
t melden.
y.
alves chaque semaine et
e chose qui ne v
Date Signed
Signe
THIS
SIDE
UP
a pas fait
Signed
Signed
Date
Date
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
Packing List
•
•
•
•
Read this installation manual completely to ensure proper installation, then file it
with the owner or maintenance department. Compliance and conformity to drain
requirements and other local codes/ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for
before discarding any packaging material. If any parts are missing, do not begin
installation until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation
is complete. Test the unit for leaks and adequate water flow. Main water supply
to the eyewash should be “ON” at all times. Provisions shall be made to prevent
unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterrupted supply of flushing fluid.
Bradley plumbed emergency fixtures require a minimum of 30 PSI (0.21 MPa)
flowing pressure. Flushing fluid should be tepid per ANSI Z358.1.
The inspection and testing results of this equipment should be recorded weekly
to verify proper operation. This equipment should be inspected annually to ensure
compliance with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be
trained regarding the placement and proper operation of emergency equipment per
ANSI Z358.1.
For questions regarding the operation or installation of this product, visit
bradleycorp.com or call 800.BRADLEY (800.272.3539).
Product warranties may also be found under ”Products” on our web site at
bradleycorp.com.
NOTICE! For classic eye/face wash units, avoid cleaners containing organic solvents, alcohols,
and hydrocarbons. Rinse with water after cleaning.
Supplies Required:
• Piping to ½" NPT water supply inlet on unit
• Pipe sealant
• Inlet strainer (recommended)
• Sign-mounting hardware
Local codes may require the installation of a backflow prevention valve to complete proper installation. Compliance with
local codes is the responsibility of the installer. Valve must be tested annually to verify that it is functioning properly.
Backflow prevention valves are not included with the fixture and may be supplied by the contractor or purchased from
Bradley Corporation.
Halo eyewash right-hand unit is shown on a sample 25" deck. Other units are similar. For classic eyewash installation,
refer to the dimensions on page 4 to determine optimal mounting position. Refer to page 8 for left-hand units.
Minimum dimensions necessary to contain splashing from Halo units are shown.
Apply pipe sealant (supplied by installer) to all male-threaded pipe joints. The top of the eyewash heads should be
positioned a minimum of 33" and a maximum of 45" from the floor and 6" from the nearest obstruction.
Proper faucet shank/handle
clearance and recommended
minimum splash containment
dimensions must be considered
when selecting the desired
location for mounting.
25"
(635mm)
A
2"
(51mm)
Ø ³⁄₁₆"
Ø 1¹⁄₈"
Deck Mounting Pattern
(drill (3) holes as shown)
8"
(203mm)
Radius
B
"OFF" Position
5¾"
(146mm)
Ref.
2⁵⁄₈" (67mm)
Ref.
Deck
7¾"
(197mm)
Ref.
5¼"
(133mm)
Min.
"ON" Position
Connect the water supply using
piping (supplied by installer) with
C
½" NPT female threaded end.
(51mm)
Slowly open the water
supply lines to relieve air
and pressurize the valve.
Halo eye/face wash right-hand unit is shown on a sample 25" deck. Other units are similar. For classic eye/face wash
installation, refer to the dimensions on page 5 to determine optimal mounting position. Refer to page 8 for left-hand units.
Minimum dimensions necessary to contain splashing from Halo units are shown.
Apply pipe sealant (supplied by installer) to all male-threaded pipe joints. The top of the eyewash heads should be positioned
a minimum of 33" (838mm) and a maximum of 45" (1143mm) from the floor and 6" (152mm) from the nearest obstruction.
Proper faucet shank/handle
clearance and recommended
minimum splash containment
dimensions must be considered
when selecting the desired
location for mounting.
25"
(635mm)
13⁷⁄₈"
(352mm)
Radius
A
2"
(51mm)
Ø ³⁄₁₆"
Ø 1¹⁄₈"
Deck Mounting Pattern
Drill (3) holes as shown.
B
Deck
"OFF" Position
13"
(330mm)
Ref.
9¼"
(235mm)
Ref.
"ON" Position
2½"
(64mm)
Min.
Connect the water supply using
piping (supplied by installer) with
C
½" NPT female threaded end.
Slowly open the water
supply lines to relieve air
and pressurize the valve.
Slowly open the water supply lines to
relieve air and pressurize the valve. Test
the unit for leaks and adequate flow.
9
S19-270C, S19-270E, S19274C, S19274E Installation
Assembly of Components and Parts List — S19-270C
Right-hand swivel version is shown in the "ON" position.
R
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN.
ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below.
Report any malfunctions immediately.
Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt
durch Unterschrift. Jegliche Störung sofort melden.
Test le fonctionnement des valves chaque semaine et
signe en bas. S'il y à quelque chose qui ne va pas fait
un rapport immédiatement.
Date
Signed
Date Signed
Datum
Unterschrift
Date
Signed
Date
Signe
Date
Signed
31
bradleycorp.com
114-051
30
23
2
19
Deck
21
1
13
14
15
16
Item Part No. Qty Description
1 S65-385CE 1 Replacement Valve Assembly, Side Swing
Right-hand swivel version is shown in the "ON" position.
R
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN.
ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below.
Report any malfunctions immediately.
Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt
durch Unterschrift. Jegliche Störung sofort melden.
Test le fonctionnement des valves chaque semaine et
signe en bas. S'il y à quelque chose qui ne va pas fait
un rapport immédiatement.
Date
Signed
Date Signed
Datum
Unterschrift
Date
Signed
Date
Signe
Date
Signed
31
bradleycorp.com
114-051
30
19
2
Eyewash Cover Prepack
S45-2675 includes items
22 and 23
22
23
22
23
1
21
20
23
27
22
Deck
26
25
13
14
29
15
16
Item Part No. Qty Description
1 S65-385 1 Replacement Valve Assembly, Side Swing