BOSE BUILT-INVISIBLE Service Manual

CLASS
FM
DWG NO.
REVISIONS REV DESCRIPTION ENG DATE 00 INITIAL RELEASE PETE CORTESE/
BOB SMITH
SIGNATURES REQUIRED
PRINT NAME SIGNATURE
TSG REPRESENTATIVE BOB SMITH CELL LEAD DAVID MIKEL REPAIR SUPERVISOR
KEVIN KING
OTHER(________________)
TSG TECHNICIAN
Pete
DATE
FRAMINGHAM, MA 01701-9168
Cortese
APPLICABLE DOCUMENTS: DESCRIPTION
SERVICE MANUAL: 172780-SM
Bose
®
BUILT-INvisible® Amplifier
Troubleshooting Tips
SIZE
A
FSCM
32108
CLASS
FM
DWG NO.
172780-TT
PAGE 1 OF 2
REV
01
Troubleshooting Tips
Bose
Refer to the Bose® BUILT-INvisible® Amplifier service manual, reference number 172780 for schematics, PCB layouts and parts lists located on service web site.
Preventative Repair Measures Note: Perform the following on all units returned for repair.
Product Check Action
Replace all 100uF, 50V caps as
Built Invisible Amplifier
* Heat sink
a precaution. The caps may have leaked, causing damage to the surrounding pcb etches and components.
®
BUILT-INvisible® Amplifier
Replace the following 100uF, 50V caps with new components, part number 149948-101H.
PCB Number Ref Des 175466, 170015 C819, C822 174562 C26, C165, C166 170010 C16, C17, 170021 C107, C207, C307, C407
If a unit returned for service has a gold colored heat sink, Polyimide tape should be added to the heat sink to prevent the personality PCB from shorting to the heat sink. This should be done even if the unit does not exhibit the symptoms mentioned above. Refer to service bulletin 172780-B1.
Troubleshooting Tips
Product Symptom Check Action
Check for open fuses on the power supply Built Invisible Amplifier
*
Dead F800, F801 and F802
Dead, blows fuse when powered on
Power amplifier PCB
board. If one or more are open check for
shorted transistors on the amplifier pcb (See
tip below).
Check the transistors that mount to the
heatsink assembly for shorts. Also check for
cold solder joints on the driver transistors.
Framingham, MA 01701-9168
SIZE
A
FSCM 32108
CLASS
FM
DWG NO.
172780-TT
SHEET
2 of 2
REV.
01
Loading...