Installation Instructions
for the MX934i
Multiplex PIR Intrusion Detector
2.0 Control Panel Programming
Refer to the multiplex programming section of your Control Panel
Reference Guide for information on programming multiplex zones
for this device.
1.0 Specifications
• Input Power: Connects directly to the Multiplex Bus
of the Control Panel and optionally to
an auxillary 12 VDC source.
• Current Draw:
2-Wire:
LED Off: <350 μA draw on Mux Bus.
In Alarm; LED On: 2 mA draw on Mux Bus.
4-Wire:
LED Off: <350 μA draw on Mux Bus.
0 mA draw on Aux. power.
In Alarm; LED On: <350 μA draw on Mux Bus.
3 mA draw on Aux. power.
• Standby Power: There is no internal standby battery.
Connect to DC power sources capable
of supplying standby power if primary
power fails. For each hour of standby
time needed, 350 μAh are required.
For UL Listed Requirements, four
hours (1400 μAh) minimum are
required.
• Coverage:
Broad (standard): 35 ft. by 35 ft. (10.7 m by 10.7 m)
Barrier (optional): 35 ft. by 10 ft. (10.7 m by 3.1 m)
Long Range (optional): 70 ft. by 10 ft. (21.4 m by 3.1 m)
• Sensitivity: Selectable for Standard, Intermediate,
or High.
• Tamper: A tamper condition is signaled through
the Multiplex Bus and displays at the
keypads.
• Temperature: The storage and operating
temperature range is -20°F to +120°F
(-29°C to +49°C). For UL Listed
Requirements, the temperature range
is +32°F to +120°F (0°C to +49°C).
• Control Panel:
Requirements: DS7400, DS7400X, or DS7400Xi
control panel with a DS7430 or
DS7436 multiplex expansion module.
The DS7400 and DS7400X require
ROM version 1.07 or greater. 9000
Series Control/Communicators with
D8125MUX Module installed.
• Options: B335 Low Profile Swivel Mount
Bracket, B338 Ceiling Mount Bracket,
OMB93-3* Barrier Mirror, OMLR93-3*
Long Range Mirror.
*Shipped in packages of three.
NOTE: Misalignment of the detector when using an optional
mounting bracket may reduce range and increase dead
zones.
•
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at:
datecodes/
http://www.boschsecurity.com/
3.0 Mounting
Avoid
Moving objects
Mounting Outdoors
Hot or cold air
directed onto
sensor
Pets or animals
Address Switches
12345678
O
N
Tampe r S w i t c h
Program
Plugs
H
ON
I
OFF
S
Location of major items - Circuit Board
The mounting surface should be solid and vibration free.
IMPORTANT
• Select a location that is most likely to intercept an intruder moving
across the coverage pattern. The recommended mounting height
range is 6.5 ft. to 8.5 ft. (2 m to 2.6 m).
• Remove the cover. Insert a thin flathead screwdriver into the
notch at the bottom of the cover and pry up.
• Remove the circuit board/mirror unit from the enclosure. Push
the board/mirror unit toward the top of the enclosure until it clears
its four retainer tabs, then lift it out.
• Open the knock-out wire entrance and route the wiring through.
-
+B-B+
LED
T-Strip
Thinwall
Knockout
for
Wiring
1
Circuit Board RetainerTabs
22
Mirror Tracks
2
= Corner 2 = Surface 3 = Bracket
1
Rear enclosure and mounting holes
3.1 Surface or Corner Mounting
• Open two holes for surface or corner mounting.
• Mark the location for the mounting screws. Use the enclosure
as a template. Pre-start the mounting screws.
• Securely attach the detector.
• Replace the circuit board/mirror unit.
• Select the Vertical Angle.
Mirror Information: The mirror is adjustable from +1° to -18° vertically
by sliding the mirror forward or back and ±10° horizontally by
rocking the mirror side to side. To change the mirror, just pull it out
from its resting grooves.
NOTE: Excessive handling of the mirror surfaces may lead to
performance degradation.
Moisture
Direct or
reflected
sunlight
2
3
1
- The following chart will help you set the correct Vertical
Angle based on the mounting height, mirror type, and
desired range.
Mounting
Height
6.5 (2.0)
7.5 (2.3)
8.5 (2.6)
Height and desired Range listed in feet (meters)
Broad Barrier Long Range
20 (6)
35 (10) 20 (6) 35 (10) 40 (12) 70 (20)
-6°
-5°
-7°
-9°
-10°
-12°
-14°
-6°
-8°
-10°
-6° -4°
-8°
-12° -8°
-3°
-5°
-5°
- The angle adjust markings are on the mirror. Slide the mirror
forward or back until the angle hash marks are in-line with
the markers on each side of the frame.
+2
0
-8
-16
Mirror
4.0 Wiring
Only apply power after all connections have been made
and inspected.
• Connect wiring as shown.
POWER
12345678
O
N
AUX
-IN+INB-INB+
-
1
IN
+B-B+
34
2
MUX
BUS
NOTE: Do not coil excess wiring inside unit.
• Seal the Wire Entrance using the foam plug provided.
Terminal Descriptions
• 1 (-) and 2 (+): Connect to the AUX Power of the control panel.
This connection is only required if LED operation (other than
during the walk test) is required. Use no smaller than #22 AWG
(0.8 mm) wire between the detector and the control panel.
• 3 (B-) and 4 (B+): Connect to the Multiplex Bus of the control
panel. Use no smaller than #22 AWG (0.8 mm) wire between
the detector and the control panel.
5.0 Configuring Detector
5.1 LED Operation Jumper
5.2 Sensitivity Mode
HIGH
INTERMEDIATE
H
ON
I
OFF
S
STANDARD
• Standard Sensitivity: Recommended setting for maximum false
alarm immunity. Tolerates environment extremes on this setting.
Not recommended for Long Range or Barrier type patterns. The
detector is shipped in Standard Sensitivity mode.
• Intermediate Sensitivity: Recommended setting for any location
where an intruder is expected to cover only a small portion of the
protected area. Tolerates normal environments on this setting.
This setting will improve your intruder catch performance.
• High Sensitivity: Fast response to intruder signals. For use in
quiet environments where thermal and illumination transients
are not anticipated.
6.0 Address Switch Settings
• Set the address switch settings (see page 3) before connecting
the MX934i to the multiplex bus.
No two devices may be set to the same address. Having
IMPORTANT
two or more units set to the same address may prevent
fault detection or cause multiplex bus failure.
12345 67
O
N
8
-
+B-B+
12345 67
O
N
8
• You can find the Address Switch Settings using the chart on
page 3, or by calculating the decimal number of the address.
LED ON
H
ON
I
OFF
S
LED OFF
O
1234 5 6 78
N
128 64 32 16 8 4 2 1
Binary Switch Values (Point 17 shown)
Zone (Point) Addresses 001 through 008 are reserved for
"on board" points on the DS7400(Xi) Series control panels.
• ON: Allows the LED to operate when activated by alarm.
• OFF: The LED will not operate on alarm.
If the detector is powered by the MUX Bus only, the LED
IMPORTANT
Do not set any multiplex devices for Addresses 001-008 when
using a DS7400(Xi) Series control panel.
is for Walk Test purposes only. Disable the LED when
Walk Testing is complete. To disable the LED, place the
jumper in the OFF position. If the detector has AUX
Power supplied, the LED operation may be left ON during
normal use.
Page 2 © 2011 Bosch Security Systems, Inc. MX934i Installation Instructions