Intrusion Alarm Systems | MX934i Multiplex PIR Intrusion Detector
MX934i Multiplex PIR Intrusion Detector
www.boschsecurity.com
u Motion Analyzer II processing
u Unique address switch settings
u Insect and draft immunity
The wall mount MX934i PIR Intrusion Detector uses
Motion Analyzer II signal processing to reduce false
alarms. Alarm and tamper conditions are transmitted
to the control panel through the two-wire multiplex
bus. The detector’s replaceable and pointable mirrors,
three coverage patterns, and three mounting options
provide installation flexibility.
Functions
Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It
tolerates extreme levels of heat and light disturbances
caused by heaters and air conditioners, hot and cold
drafts, sunlight, lightning, and moving headlights.
Insect and Draft Immunity
The sealed optical chamber provides immunity to
drafts and insects.
Three Sensitivity Settings
• Standard Sensitivity: Recommended setting for
maximum false alarm immunity. Tolerates
environment extremes on this setting. Not
u Three sensitivity settings
recommended for long range or barrier type coverage
patterns. The detector is shipped in Standard
Sensitivity mode.
• Intermediate Sensitivity: Recommended setting for
any location where an intruder is expected to cover
only a small portion of the protected area. Tolerates
normal environments on this setting. This setting
identifies intruders more accurately.
• High Sensitivity: Fast response to intruder signals. For
use in quiet environments where heat and light
fluctuations are not anticipated.
Certifications and approvals
RegionCertification
EuropeCE2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD) [MX934i]
USAULANSR: Intrusion Detection Units
(UL639)
Page 2
16.5 ft
16.5 ft
0 ft
0 m
0 ft
50 m
50 m
33 ft
0 m10 m
0 ft
0 ft
0 m
6.5 ft
2 m
33 ft
0 m
10 m
0 ft
0 m
0 ft
0 m
36 ft
11 m
1.5 m
1.5 m
5 ft
5 ft
0 ft
0 m
0 ft
0 m
36 ft
1.5 m
11 m
5 ft
0 m
21 m
0 m
1.5 m
1.5 m
0 ft
5 ft
5 ft
0 ft69 ft
0 m
0 m
0 ft
5 ft
1.5 m
0 ft
21 m
69 ft
2 | MX934i Multiplex PIR Intrusion Detector
Installation/configuration notes
Compatibility Information
Control PanelsMultiplex Expansion Modules
• DS7400Xi Series
• G Series
Notice
The DS7400Xi Series Control Panels require ROM
version 1.07 or greater.
• DS7430
• DS7436
• D8125MUX
Mounting Considerations
Select a location that is most likely to intercept an
intruder moving across the coverage pattern. Ensure
the mounting surface is solid and vibration free. Avoid
hot and cold drafts, windows, moisture, direct or
reflected sunlight, and small animals. The MX934i is
not for outdoor mounting.
Notice
Misaligning the detector in an optional mounting
bracket can reduce range and increase dead
zones.
Top View
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)
SideView
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)
Top View
Optional Long Range Coverage: 21 m x 3 m
(70 ft x 10 ft)
Top View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)
Side View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)
Side View
Optional Long Range Coverage: 21 m x 3 m
(70 ft x 10 ft)
Technical specifications
Enclosure Design
Dimensions:10.8 cm x 7 cm x 4.6 cm
(4.25 in. x 2.75 in. x 1.8 in.)
Environmental Considerations
Temperature
(Operating):
Radio
Frequency
Interference
(RFI) Immunity:
-29°C to +49°C (-20°F to +120°F)
For UL Listed Applications, 0°C to + 49°C (+32°F to
+120°F)
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
Mounting
Height (recommended):2 m to 2.6 m (6.5 ft to 8.5 ft)
Location:Surface or corner mount.
Internal Pointability:Coverage is adjustable ±10°
Ceiling mount with the appropriate
mounting bracket.
horizontally, +1° to -18° vertically.
Page 3
3 | MX934i Multiplex PIR Intrusion Detector
Outputs
Alarm:Signals through the multiplex bus
Tamper:A tamper condition is signaled through the multiplex bus
and displays at the keypads.
Power Requirements
Current Draw
(two-wire):
Current Draw
(four-wire):
Input (Voltage):Connects directly to the multiplex (MUX) bus of
Standby Power:There is no internal standby battery. Connect to
LED off: <0.4 mA draw on MUX bus
LED on: 2 mA draw on MUX bus
LED off: <0.4 mA draw on MUX bus
0 mA draw on Aux. power
LED on: <0.4 mA draw on MUX bus
3 mA draw on Aux. power
the control panel and optionally to an auxiliary
12 VDC source
DC power sources capable of supplying standby
power if primary power fails. For each hour of
standby time needed, 0.4 mAh are required. For
UL Listed Requirements, four hours (1.4 mAh)
minimum are required.
Ordering information
MX934i Multiplex PIR Intrusion Detector
Provides PIR, 10 m x 10 m (35 ft x 35 ft) coverage with
multiplex bus interface.
Order number MX934i
Accessories
B335-3 Swiveling low-profile mount
Swiveling, low-profile, plastic mount for wall mounting.
The vertical swivel range is +10° to -20°, while the
horizontal swivel range is ±25°. Available in triple
packs.
Order number B335-3
B338 Universal Ceiling‑mount Bracket
Swiveling plastic mount for ceiling mounting. The
vertical swivel range is +7° to -16°, while the horizontal
swivel range is ±45°.
Order number B338
OMB93‑3 Barrier Mirror
Provides barrier coverage with an 11 m x 3 m
(35 ft x 10 ft) pattern. Shipped in packages of three.
Order number OMB93-3
OMLR93‑3 Long‑range Mirror
Provides long-range coverage with a 21 m x 3 m
(70 ft x 10 ft) pattern. Shipped in packages of three.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com