6 720 874 421 (2017/04) ZA Mini VRF Heat Pump Outdoor Unit
2 | PRECAUTIONS
1. PRECAUTIONS
■ Before installing this equipment, ensure all local and national
regulations are complied with.
■ Read these ”PRECAUTIONS” carefully prior to Installation.
■ Before performing maintenance ensure the electrical power
circuit has been turned off. Failure to do so will result in serious
injury.
■ Ensure both the installation manual and the owners manual are
kept together and handed to the customer upon completion.
CAUTION
New Refrigerant Air Conditioner Installation
CAUTION
An all-pole disconnection device which has at least 3 mm separation
distance in all poles and a residual current device (RCD) shall be
incorporated into the fixed wiring in accordance with national wiring
regulations.
WARNING
The appliance shall be installed in accordance with national wiring
regulations.
When installing, ensure communication and electrical power supply
cables do not touch the copper pipework.
The temperature of the refrigeration circuit will be high and may damage
cables.
An all-pole disconnection device which has at least 3 mm separation
distance between all poles and a residual current device(RCD)with the
rating of above 10 mA shall be incorporated in the fixed wiring according
to the national regulations.
Ensure only qualified persons carry out works on this equipment.
Incorrect installation may result in can damage or serious injury.
Do not modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
Exposing the unit to water or other moisture before installation may
cause a short-circuit on the electrical components.
Do not store the unit where it can be exposed to water or moisture.
After unpacking, ensure you inspect the unit for damage.
When installing this equipment, anti vibration pads must be installed to
stop vibration.
To avoid personal injury (with sharp edges), care must be taken when
handling components.
Installation of the unit must be done as per the instructions set in this
installation manual.
Incorrect installation may result in component failure, damage to property
or injury.
When the air conditioning unit is installed in a small room, provide
appropriate measures to ensure that the concentration of refrigerant
leakage in the room does not exceed the thickness level should a leak
occur.
Install the air conditioning unit securely in a location where the base can
sustain the weight adequately.
If refrigerant gas has leaked during the installation work, ventilate the
room immediately.
If the leaked refrigerant gas comes in contact with a naked flame, noxious gas
may be generated..
After installation is complete, ensure a satisfactory strength/tightness
test has been performed to ensure there is no refrigerant gas leakage.
Electrical work must be performed by a qualified electrician in
accordance with the Installation Manual.
Ensure equipment is grounded.
Do not connect ground wires to gas pipes, water pipes, lightning rods or
ground wires for telephone cables.
Conform with national wiring standards.
Inappropriate grounding may cause electric shock.
Do not install the air conditioner in a location where it is at a risk of
exposure to a combustible gas.
CONTENTS PAGE
1. PRECAUTIONS .................................................................... 2
2. ATTACHED FITTINGS ........................................................... 3
3. OUTDOOR UNIT INSTALLATION ............................................ 3
4. INSTALLING THE CONNECTIVE PIPEWORK ............................5
5. ELECTRICAL WIRING ........................................................... 9
6. TEST RUNNING ................................................................. 12
7. PRECAUTIONS ON REFRIGERANT LEAKAGE ........................ 12