Bosch FPC-500 Quick Start Guide

Quick Selection Guide
Fire Systems: Conventional Fire Panel 500 Series
Quick Panel Guide FPC-500-2 FPC-500-4 FPC-500-8
▶ Zones ▶ Programmable inputs ▶ AUX output ▶ Outputs sounder/strobe ▶ Relays ▶ Alarm counter ▶ Event history ▶ Test history ▶ Max. quantity extension boards (Open Collector/Relay)
Example Applications
Small School Small hotel
2 4 8 1 1 2 1 1 1 2 2 2 2 2 2
999 alarms 999 alarms 999 alarms 1000 entries 1000 entries 1000 entries 1000 entries 1000 entries 1000 entries
0 1 x 4 2 x 4
Legend
Conventional Fire Panel 500 series
Conventional Smoke Detector 320 series
Beacon
Conventional Smoke Detector 500 series
Manual call point
Sounder
210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 1210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 1 04.02.21 11:4004.02.21 11:40
Quick Selection Guide
Fire Systems: Conventional Fire Panel 500 Series
Connection Overview
Automatic Detectors
Sounders
Strobes
Manual Call Points
Special Detectors
210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 2210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 2 04.02.21 11:4004.02.21 11:40
Optional External Power Supply
Quick Selection Guide
Fire Systems: Conventional Fire Panel 500 Series
Automatic Fire Detectors
CTN Short Description Order number
FCP-OC 320 Multisensor Detector Optical/Chemical F.01U.026.292 FCP-O 320 Optical Smoke Detector F.01U.026.293 FCP-OT 320 Multisensor Detector Optical/Thermal F.01U.026.295 FCH-T 320 Heat Detector F.01U.026.291 FCH-T 320-FSA Heat Detector, for Fire Barrier in conformity with the the German DIBt F.01U.026.294 FCP-O 500 Optical Smoke Detector, White F.01U.510.649 FCP-O 500-P Optical Smoke Detector, Transparent with Color Inserts F.01U.510.654 FCP-OC 500 Multisensor Detector Optical/Chemical, White F.01U.510.653 FCP-OC 500-P Multisensor Detector Optical/Chemical, Transparent with Color Inserts F.01U.510.656 FAA-420-RI-DIN Remote indicator for DIN application F.01U.289.620 18 FAA-420-RI-ROW Remote Indicator F.01U.289.120 24
Max. Quantity (observe local regulations)
32 per zone 32 per zone 32 per zone 32 per zone 32 per zone 12 12 12 12
Manual Call Points
CTN Short Description Order number
FMC-120-DKM-G-R FormG, Red F.01U.011.951 FMC-120-DKM-H-R FormH, Red F.01U.011.952 FMC-120-DKM-G-B FormG, Blue F.01U.011.953 FMC-120-DKM-H-B FormH, Blue F.01U.011.954 FMC-120-DKM-G-Y FormG, Yellow F.01U.011.955 FMC-300RW-GSGBU Manual Call Point with Glass Pane,Blue F.01U.012.724 FMC-300RW-GSRBU Manual Call Point Resettable,Blue F.01U.012.770 FMC-300RW-GSGRD Manual Call Point with Glass Pane,Red F.01U.012.771 FMC-300RW-GSRRD Manual Call Point Resettable,Red F.01U.012.777 FMC-300RW-GSGYE Manual Call Point with Glass Pane,Yellow F.01U.012.778 FMC-300RW-GSRYE Manual Call Point Resettable,Yellow F.01U.012.779
210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 3210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 3 04.02.21 11:4004.02.21 11:40
Max. Quantity
observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations observe local regulations
Quick Selection Guide
Fire Systems: Conventional Fire Panel 500 Series
Signalling devices
CTN Short Description Order number
FNM-320-SRD Sounder Red, Surface Mounting F.01U.143.878 FNM-320-FRD Sounder Red, Flush Mounting F.01U.143.879 FNM-320-SWH Sounder White, Surface Mounting F.01U.143.880 FNM-320-FWH Sounder White, Flush Mounting F.01U.143.881 MSS300-WH-EC FNS-320-SRD Beacon Red, Surface Mounting F.01U.143.883 FNS-320-SYE Beacon Amber, Surface Mounting F.01U.143.884 FNS-320-SWH Beacon Clear, Surface Mounting F.01U.143.885 FNS-320-SGR Beacon Green, Surface Mounting F.01U.143.886 FNM-320-LEDSRD Sounder Red with LED, Surface Mounting F.01U.143.882
Detector Base Sounder White
4.998.120.501 18
Max. Quantity
11 11 11 11
2 2 2 2 11
Special detectors
CTN Short Description Order number
Fireray 50 RV Linear Smoke Detector, Max range 50 m 4.998.142.205 Fireray 100 RV Linear Smoke Detector, Max range 100 m 4.998.142.206 Fireray 3000 Fireray 5000-EN Linear Smoke Detectors with self-alignment F.01U.143.245 FCS-LWM-1 Linear Heat Detector F.01U.026.138 FCS-LHD-2 FCS-320-TM Conventional Aspirating Smoke Detector TM Series F.01U.041.195 FCS-320-TM-R Conventional Aspirating Smoke Detector TM Series F.01U.141.196 FCS-320-TP1 Conventional Aspirating Smoke Detector TP Series F.01U.041.197 FCS-320-TP2 Conventional Aspirating Smoke Detector TP Series (with two detector modules) F.01U.141.198 FCA-320-RELAY Relay Module F.01U.141.200 FCA-320-RESET Reset Module F.01U.141.199
210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 4210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 4 04.02.21 11:4004.02.21 11:40
Linear Smoke Detector
Linear Heat Detector
F.01U.290.195 12
F.01U.332.846 2
Max. Quantity
12 12
4 12
2 1
only with external power supply
18 24
Quick Selection Guide
Fire Systems: Conventional Fire Panel 500 Series
Optional EOL-modules (for EN 54-13 conformity)
CTN
FLM-320-EOL2W FLM-320-EOL4W-S
Short Description
Conventional EOL Module 2-Wire Conventional EOL Module 4-Wire
Optional accessories
CTN
FPC-500-OCEXT FPC-500-RLYEXT FPC-500-KEY
Short Description
OC extension board Relay extension board Access key for panel
Optional external power supply
CTN
FPP-5000
Short Description
External power supply
Order number
F.01U.083.619 F.01U.083.620
Order number
F.01U.164.794 F.01U.164.795 F.01U.164.844
Order number
F.01U.511.307
Remark
one module per zone one module per zone
Remark
Remark
to be connected directly next to the panel <1m
Remark: 4-wire detectors can only be connected to the last zone of the FPC-500 Series
210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 5210204_FPC_500_Quick_Selection_Guide_Multi-language_final.indd 5 04.02.21 11:4004.02.21 11:40