u Scale-up network storage solution: controller unit
with 12 internal HDDs expandable via state-of-theart SAS interface-connected expansion units
u Configurable hardware-based RAID protection
(RAID‑5 or RAID‑6) for highest system performance
DSA E2800 represents the next generation of
DSA E‑Series, the iSCSI-based digital video disk arrays
by Bosch. They are state-of-the-art platforms designed
for the security industries most demanding digital
video storage applications to manage relentlessly
growing digital video data. Since HD and recently UHD
(4K) IP cameras and encoders have entered the
surveillance market, the ever growing need for high
bandwidth and low complexity of the storage
infrastructure are the main challenges. The next
generation DSA E2800 disk arrays are the answer to it.
System overview
DSA E2800 is based on one 2U controller unit with 12
internal 3.5”, 7.2 K, NL-SAS (Serial Attached SCSI),
enterprise HDDs (Nearline SAS).
The controller unit is available as a standard single
controller configuration and as a dual controller
configuration for high availability requirements.
u Redundant hot-swappable power supplies and
cooling fans
u Two 10 Gigabit Ethernet ports for highest speed
iSCSI connectivity
u Fully modular design for ease of service and
protected by NetApp services, including a 3 years
next business day on-site support
This storage system is a high-performance solution
designed with robust flexibility that makes it a great fit
for wide-ranging video surveillance requirements. Its
balanced performance is designed for supporting high
bandwidth and I/O intensive workloads.
The DSA E2800 disk shelf option with a standard 12bay expansion unit with 12 x 3.5”, 7.2 K, NL-SAS,
enterprise HDD (2U) enables custom configurations
that can be optimized for any standard mid- to
enterprise-environments.
And the DSA E2800 fully redundant I/O paths,
advanced protection features, and extensive
diagnostic capabilities deliver high levels of
availability, integrity, and security.
Functions
DSA E2800 is the co-branded E2800 series from
NetApp. It is a scale-up network storage solution that
provides security, highest “in-the-box” scalability,
peace-of-mind data protection, and simplified
management of all your video data. NetApp pioneered
Page 2
2 | DSA E-Series (E2800 12-bay)
the iSCSI protocol years ago and offers with the new
E2800 product line a high-end product for the video
surveillance market.
DSA E2800 in single or dual controller configuration
allows connecting up to seven 12-bay expansion units
(12 x HDDs per expansion shelf) to one single or dual
controller base unit.
It is a fully featured RAID protected disk array which
provides RAID‑5 protection for capacity-oriented
environments and RAID‑6 protection for availabilityoriented environments. The RAID protection is based
on a hardware RAID implementation for highest
system performance. RAID‑6 is highly recommended if
the system will be used with a larger number of disk
shelf expansion units.
High reliability and availability
DSA E2800 keeps your data safe and available with
redundant hot-swappable power supplies and fans,
and protects from double-disk failure and single bit
errors during RAID rebuilds with high performance
RAID‑6.
It is also prepared for use of Dynamic Disk Pools,
which allow for very low rebuilt times.
With over 20 years of storage development experience,
DSA E‑Series is based on a field-proven design
architected to provide high reliability and availability.
Its redundant components, automated path failover,
and online administration keep organizations
productive 24 x 7 x 365.
Further high-availability features include:
• Automatic drive failover and detection and rebuild if
using global hot spare drives
• Data cache with battery backup and de-stage to flash
• SANtricity proactive drive health monitoring
identifies problem drives before they create issues
Monitoring
Full SNMP support with MIB‑II and NetApp custom
MIBs supported. In case of component failures SNMP,
e-mail alert notifications will be generated.
Additionally, an event monitor for sending alert
notifications to a central major event log is available.
If the device is connected to the Internet/Intranet
automatically generated AutoSupport messages can
be sent. AutoSupport enhances customer service,
speeds problem resolution, and helps prevent issues.
It automatically sends alerts based on either eventbased or time-based (weekly, daily, other) criteria to
provide faster and better customer service, keeping
your systems up and running longer.
Management
NetApp SANtricity storage management software
combines robustness and ease of use. Full-time
storage administrators appreciate the extensive
configuration flexibility which allows optimal
performance tuning and complete control over data
placement. Part-time system administrators love the
intuitive interface and wizards designed to simplify
their tasks. With its dynamic capabilities, SANtricity
software supports on-the-fly expansion,
reconfiguration, and maintenance without interrupting
storage system I/O.
Certifications and approvals
RegionRegulatory compliance/quality marks
EuropeCEDoC DSA E-Series (E2800 12-bay)
Installation/configuration notes
Bosch provides the necessary software tools for an
initial setup of the storage in a video surveillance
environment. In addition, the system provides web
based configuration and a powerful Command Line
Interface (CLI) which is fully remote accessible by SSH
(Secure Shell).
DSA E‑Series offers per controller a serial console
connector and 2 dedicated Ethernet management
ports for management access, 2 x 10 Gigabit Ethernet
iSCSI host ports, and 2 additional optical iSCSI ports.
Each port must be configured with a separate IP
address; the 4 iSCSI ports are separated access paths
to the storage system and represent an individual
iSCSI target each.
In dual controller systems the iSCSI ports with the
same number are tied together for redundancy
purpose, while one of the ports is a fall-back path for
an iSCSI port on the other controller.
The net capacity available is shown in the following
tables:
Configuration Information
(RAID-5)
12-bay unit (12 x 4 TB)40964
12-bay unit (12 x 8 TB)81928
12-bay unit (12 x 10 TB)102410
Configuration Information
(RAID-6)
12-bay unit (12 x 4 TB)37240
12-bay unit (12 x 8 TB)74480
12-bay unit (12 x 10 TB)93100
Net Capacity (GB)
Net Capacity (GB)
Performance data per controller unit in a 10 Gbit/s
network (in a 1 Gbit/s network the available network
bandwidth is the limiting factor):
Network Uplink 10 GbE (RAID-5 / RAID-6)
IP camerasBandwidth Mbps
Single port4001250 / 250
Dual port800 (400 per port)1250 / 250
Page 3
3 | DSA E-Series (E2800 12-bay)
Notice
Number of IP cameras refers to default software
configuration (no direct replay mode). Bandwidth
data refers to <Recording> / <Replay>.
Notice
DSA E2800 units are only supported by Bosch
camera firmware version 6.32 and later,
VRM Video Recording Manager version 3.70 and
later, and Configuration Manager version 5.51 and
later.
Dual controller systems require Bosch camera
firmware version 6.43 and later,
VRM Video Recording Manager version 3.71 and
later, and Configuration Manager version 5.53 and
later.
Notice
The next business day on-site service level can
only be provided if the respective system has
been registered immediately after receipt and
installation. Otherwise, service will be provided
based on best effort basis.
Information about registration details is available
in every shipment (registration form) or from the
Bosch online product catalog.
Next business day services cannot be provided in
every country everywhere. For limitations and
exceptions see the registration details in the
registration form.
Technical specifications
Electrical requirements 12-bay controller units
ParameterLow rangeHigh range
Nominal voltage100 VAC240 VAC
Frequency50 to 60 Hz50 to 60 Hz
Electrical requirements 12-bay expansion units
Maximum operating
current
System rating plate
label
Power ratings 12-bay controller units (typical operating power)
KVA0.451
Watts451.3
BTU/h1543.4
Note: for detailed information please see the latest NetApp E‑Series Site
Preparation Guide
Power ratings 12-bay expansion units (typical operating power)
KVA0.25
Watts248.7
BTU/h850.55
Note: for detailed information please see the latest NetApp E‑Series Site
Preparation Guide
Mechanical
Dimensions (H x W x D)
• 12-bay unit8.68 x 44.7 x 53.6 cm
• Shipping carton49.53 x 80.01 x 71.12 cm
Weight
• Maximum weight
controller unit
• Maximum weight
expansion unit
5.3 A2.1 A
12.0 A6.3 A
(3.41 x 17.6 x 21.1 in)
(19.5 x 31.5 x 28.0 in)
29.0 kg (63.9 lb)
27.12 kg (59.78 lb)
Typical operating
current
Maximum operating
current
System rating plate
label
Electrical requirements 12-bay expansion units
ParameterLow rangeHigh range
Nominal voltage100 VAC240 VAC
Frequency50 to 60 Hz50 to 60 Hz
Typical operating
current
4.51 A1.92 A
7.2 A2.9 A
12.0 A6.3 A
2.49 A1.16 A
• Maximum shipping weight36.2 kg (80.0 lb)
Space requirements
Front clearance (cooling and
maintenance)
Rear clearance (cooling and
maintenance)
Environmental
Temperature
• Operating range (both
cabinet and subsystem)
• Storage range0 °C to +70 °C (+32 °F to
Relative humidity (non-condensing)
81.2 cm (32.0 in)
60.9 cm (24.0 in)
+10 °C to +40 °C (+50 °F to
+104 °F)
+158 °F)
Page 4
4 | DSA E-Series (E2800 12-bay)
Environmental
• Operating range (both
cabinet and subsystem)
• Storage range5 to 95%
Altitude
• Operating rangeSea level to 3048 m (10,000 ft)
• Storage range304.8 m (1000 ft) below sea
Acoustic noise
• Sound power controller
unit (standby operation)
• Sound power expansion
unit (standby operation)
• Sound pressure (normal
operation)
20 to 80%
above sea level
level to 12,192 m (40,000 ft)
above sea level
66 dB max
68 dB max
56 dBA max
Notes:
General technical information for the RAID systems are
provided in the NetApp E‑Series
Site Preparation Guide - available at:
https://library.netapp.com/ecm/ecm_download_file/
ECMLP2773643
NetApp, AutoSupport, and SANtricity are registered trademarks of NetApp, all rights
reserved. All data and dimensions are referenced from the NetApp Site Preparation Guide
and from the NetApp Website and are subject to change without notice.
Ordering information
DSA-N2E8X4-12AT Base unit 12x4TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, single controller.
DSA E2800, 12 x 4 TB HDD
Order number DSA-N2E8X4-12AT
DSA-N2C8X4-12AT Dual controller unit 12x4TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, dual controller.
DSA E2800, 12 x 4 TB HDD
Order number DSA-N2C8X4-12AT
DSX-N1D8X4-12AT Expansion unit 12x4TB
High-performance and high-capacity storage expansion
unit with iSCSI disk arrays.
DSA E2800, 12 x 4 TB HDD
Order number DSX-N1D8X4-12AT
DSA-N2E8X8-12AT Base unit 12x8TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, single controller.
DSA E2800, 12 x 8 TB HDD
Order number DSA-N2E8X8-12AT
DSA-N2C8X8-12AT Dual controller unit 12x8TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, dual controller.
DSA E2800, 12 x 8 TB HDD
Order number DSA-N2C8X8-12AT
DSX-N1D8X8-12AT Expansion unit 12x8TB
High-performance and high-capacity storage expansion
unit with iSCSI disk arrays.
DSA E2800, 12 x 8 TB HDD
Order number DSX-N1D8X8-12AT
DSA-N2E8XA-12AT Base unit 12x10TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, single controller.
DSA E2800, 12 x 10 TB HDD
Order number DSA-N2E8XA-12AT
DSA-N2C8XA-12AT Dual controller unit 12x10TB
High-performance and high-capacity storage system
base unit with iSCSI disk arrays, dual controller.
DSA E2800, 12 x 10 TB HDD
Order number DSA-N2C8XA-12AT
DSX-N1D8XA-12AT Expansion unit 12x10TB
High-performance and high-capacity storage expansion
unit with iSCSI disk arrays.
DSA E2800, 12 x 10 TB HDD
Order number DSX-N1D8XA-12AT
Accessories
DSA-EDTK8-4TB HDD 4TB for 12bay
Hard disk storage expansion with a capacity of 4 TB.
For DSA E2800 12-bay expansion units.
Order number DSA-EDTK8-4TB
DSA-EDTK8-8TB HDD 8TB for 12bay
Hard disk storage expansion with a capacity of 8 TB.
For DSA E2800 12-bay expansion units.
Order number DSA-EDTK8-8TB
DSA-EDTK8-10TB HDD 10TB for 12bay
Hard disk storage expansion with a capacity of 10 TB.
For DSA E2800 12-bay expansion units.
12-month service uplift to SupportEdge Standard:
parts replacement within 4 hours for DSA E2800 4 TB,
6 TB, or 8 TB based 12-bay controller or expansion
units, available for in-warranty systems only.
12-month service uplift to SupportEdge Standard:
parts replacement within 4 hours for DSA E2800 10 TB
or 12 TB based 12-bay controller or expansion units,
available for in-warranty systems only.
DSA-S2E8X48-NRD DSA E2812 4-8TB Non Ret DO 1yr
POS
12-month non-returnable disk option for DSA E2800
4 TB, 6 TB, or 8 TB based 12-bay controller or
expansion units, available for in-warranty systems only.
Order number DSA-S2E8X48-NRD
DSA-S2E8XAC-NRD DSA E2812 10-12TB Non Ret DO 1yr
POS
12-month non-returnable disk option for DSA E2800
10 TB or 12 TB based 12-bay controller or expansion
units, available for in-warranty systems only.
Order number DSA-S2E8XAC-NRD
DSA-S2E8X48-SLP DSA E2812 4-8TB SES Ext 1yr POS
12-month extension of SupportEdge Standard next
business day for DSA E2800 4 TB, 6 TB, or 8 TB based
12-bay controller or expansion units, available for a 4
and a 4th/5th year as a standard.
Order number DSA-S2E8X48-SLP
DSA-S2E8XAC-SLP DSA E2812 10-12TB SES Ext 1yr POS
12-month extension of SupportEdge Standard next
business day for DSA E2800 10 TB or 12 TB based 12bay controller or expansion units, available for a 4
th
and a 4th/5th year as a standard.
Order number DSA-S2E8XAC-SLP
th
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.