u Scale-up network storage solution: controller unit
with 12 internal HDDs with up to 192 HDDs via
state-of-the-art SAS interface-connected expansion
units
DSA E2700 represents the next generation of
DSA E‑Series, the iSCSI-based digital video disk arrays
by Bosch. They are state-of-the-art platforms designed
for the security industries most demanding digital
video storage applications to manage relentlessly
growing digital video data. Since HD and recently UHD
(4K) IP cameras and encoders have entered the
surveillance market, the ever growing need for high
bandwidth and low complexity of the storage
infrastructure are the main challenges. The next
generation DSA E2700 is the answer to it.
System overview
DSA E2700 is based on one 2U controller unit with 12
internal 3.5”, 7.2 K, NL-SAS (Serial Attached SCSI),
enterprise HDDs (Nearline SAS).
The controller unit is available as a standard Simplex
Controller configuration and as a Dual Simplex
Controller configuration for high-capacity and extreme
performance requirements.
u Configurable hardware-based RAID protection
(RAID‑5 or RAID‑6) for highest system performance
u Redundant hot-swappable power supplies and
cooling fans
u Two 10 Gigabit Ethernet ports for highest speed
iSCSI connectivity
u Fully modular design for ease of service and
protected by NetApp services, including a 3 years
next business day on-site support
This storage system is a high-performance solution
designed with robust flexibility that makes it a great fit
for wide-ranging video surveillance requirements. Its
balanced performance is designed for supporting high
bandwidth and I/O intensive workloads.
The DSA E2700 disk shelf option with a standard 12bay expansion unit with 12 x 3.5”, 7.2 K, NL-SAS,
enterprise HDD (2U) and a high-density 60-bay
expansion unit with 60 x 3.5”, 7.2 K, NL-SAS,
enterprise HDD (4U) enable custom configurations
that can be optimized for any standard mid- to
enterprise-environments.
And the DSA E2700 fully redundant I/O paths,
advanced protection features, and extensive
diagnostic capabilities deliver high levels of
availability, integrity, and security.
Functions
DSA E2700 is the co-branded E2700 series from
NetApp. It is a scale-up network storage solution that
provides security, highest “in-the-box” scalability,
Page 2
2 | DSA E-Series 4TB (E2700)
peace-of-mind data protection, and simplified
management of all your video data. NetApp pioneered
the iSCSI protocol years ago and offers with the new
E2700 product line a high-end product for the video
surveillance market.
DSA E2700 in Simplex/Dual Simplex Controller
configuration allows connecting up to seven 12-bay
expansion units (12 x HDDs per expansion shelf) to
one single/dual controller base unit.
Note: This is only valid for 12-bay expansion units with
two ESM modules.
The Dual Simplex Controller configuration allows up to
three 60-bay expansion units (60 x HDDs per
expansion shelf) connected to one dual controller
base unit. Connecting the 60-bay expansion unit to a
single controller unit is not supported.
It is a fully featured RAID protected disk array which
provides RAID‑5 protection for capacity-oriented
environments and RAID‑6 protection for availabilityoriented environments. The RAID protection is based
on a hardware RAID implementation for highest
system performance. RAID‑6 is highly recommended if
the system will be used with a larger number of disk
shelf expansion units.
High reliability and availability
DSA E2700 keeps your data safe and available with
redundant hot-swappable power supplies and fans,
and protection from double-disk failure and single bit
errors during RAID rebuilds with high performance
RAID‑6.
With over 20 years of storage development experience,
DSA E2700 is based on a field-proven design
architected to provide high reliability and availability.
Its redundant components, automated path failover,
and online administration keep organizations
productive 24 x 7 x 365.
Further high-availability features include:
• Automatic drive failover and detection and rebuild if
using global hot spare drives
• Data cache with battery backup and de-stage to flash
• SANtricity proactive drive health monitoring identifies
problem drives before they create issues
Monitoring
Full SNMP support with MIB‑II and NetApp custom
MIBs supported. In case of component failures SNMP,
e-mail alert notifications will be generated.
Additionally, an event monitor for sending alert
notifications to a central major event log is available.
If DSA E2700 is connected to the Internet/Intranet
automatically generated AutoSupport messages can be
sent. AutoSupport enhances customer service, speeds
problem resolution, and helps prevent issues. It
automatically sends alerts based on either event-based
or time-based (weekly, daily, other) criteria to provide
faster and better customer service, keeping your
systems up and running longer.
Management
NetApp SANtricity storage management software
combines robustness and ease of use. Full-time
storage administrators appreciate the extensive
configuration flexibility which allows optimal
performance tuning and complete control over data
placement. Part-time system administrators love the
intuitive interface and wizards designed to simplify
their tasks. With its dynamic capabilities, SANtricity
software supports on-the-fly expansion,
reconfiguration, and maintenance without interrupting
storage system I/O. The software is available as 32‑bit
and 64‑bit Microsoft OS installation package (available
on the Bosch product catalogue).
Certifications and approvals
RegionCertification
EuropeCEDSA E-Series (E2700)
CEDSA E-Series 4TB (E2600)
CEDSA E-Series (E2600)
USAULDSA E-Series (E2700)
Installation/configuration notes
Installable on 32-bit and 64-bit Windows Clients,
SANtricity storage management software provides
easy central management of all DSA E‑Series arrays
available within one network. There is no additional
software necessary to be installed on peripheral
devices. In addition, the system provides a powerful
Command Line Interface (CLI) which is fully remote
accessible by SSH (Secure Shell).
DSA E‑Series offers per controller a serial console
connector and two dedicated Ethernet management
ports for management access and 2 x 10 Gigabit
Ethernet iSCSI host ports. Each port must be
configured with a separate IP address; the two iSCSI
host ports are separated access paths to the storage
system and represent an individual iSCSI target each.
The net capacity available is shown in the following
table:
Configuration Information
(RAID-5)
Simplex Controller unit
(12 x 4 TB)
Dual Simplex Controller unit
(12 x 4 TB)
12-bay expansion unit
(12 x 4 TB)
60-bay expansion unit
(60 x 4 TB)
Net Capacity (GB)
40964
40964
40964
204820
Page 3
3 | DSA E-Series 4TB (E2700)
Configuration Information
(RAID-6)
Simplex Controller unit
(12 x 4 TB)
Dual Simplex Controller unit
(12 x 4 TB)
12-bay expansion unit
(12 x 4 TB)
60-bay expansion unit
(60 x 4 TB)
Net Capacity (GB)
37240
37240
37240
186200
Performance data per controller unit in a 10 Gbit/s
network (in a 1 Gbit/s network the available network
bandwidth is the limiting factor):
Network Uplink 10 GbE (RAID-5 / RAID-6)
iSCSI
Single
port
Sessions
400650 / 1501050 / 200
Bandwidth
Mbps
(Base Unit
12 x HDD)
Bandwidth Mbps
(min. 1 x Base Unit + 1 x
Expansion Unit:
24 x HDD)
Notice
The next business day on-site service level can
only be provided if the respective system has
been registered immediately after receipt and
installation. Otherwise, service will be provided
based on best effort basis.
Information about registration details is available
in every shipment (registration form) or from the
Bosch online product catalogue.
Next business day services cannot be provided in
every country everywhere. For limitations and
exceptions see the registration details in the
registration form.
Dimensions controller unit and 12-bay expansion unit
Dual
port
800 (400
per port)
650 / 1501050 / 200
Note: The overall bandwidth is per controller and does
not depend on the number of used ports. The number
of cameras will double by using two ports instead of
one port.
Notice
iSCSI session specifications refer to the total
number of recording and replay sessions.
Bandwidth data refer to <Recording> / <Replay>.
The maximum overall bandwidth of a Dual Simplex
Controller system is 2500 Mbps read/write
throughput in a 10 GbE uplink network.
Notice
DSA E2700 units are only supported by Bosch
Firmware 5.60 and later, VRM 3.0 and later, and
Configuration Manager 5.32 and later.
Dimensions 60-bay expansion unit
Front view controller unit
1 End Caps (the Left End Cap
has the Controller-Drive Tray
Summary LEDs)
2 Drive Canisters
Page 4
1
2
1
2
4 | DSA E-Series 4TB (E2700)
Rear view Dual Simplex Controller unit
1 Controller Canister2 Power-Fan Canister
Front view 12-bay expansion unit
1 End Caps (the Left End Cap
3 Right End Cap
has the Drive Tray LEDs)
2 Drives
Rear view 12-bay expansion unit
Rear view 60-bay expansion unit
1 Fan Canisters3 ESM Canisters
2 Power Canisters
Technical specifications
Simplex Controller 12 x 4 TB (DSA‑N2E7X4‑12AT) /
Dual Simplex Controller 12 x 4 TB
(DSA‑N2C7X4‑12AT)
All parameters are per controller unit:
Electrical requirements
ParameterLow rangeHigh range
1 ESM A Canister3 Power-Fan A Canister
2 ESM B Canister
Front view 60-bay expansion unit
1 Drive Drawer 14 Drive Drawer 4
2 Drive Drawer 25 Drive Drawer 5
3 Drive Drawer 3
Nominal voltage100 VAC240 VAC
Frequency50 to 60 Hz50 to 60 Hz
Typical operating
3.61 A1.50 A
current
Maximum operating
5.16 A2.15 A
current
Sequential drive
4.27 A1.76 A
group spin up
Simultaneous drive
6.81 A2.71 A
spin up
System rating plate
9.0 A3.6 A
label
Power ratings (typical operating power)
KVA0.361
AC Watts358
BTU/h1220
Note: for detailed information please see the latest NetApp E‑Series
Storage Systems Site Preparation Guide available on the Bosch product
catalogue.
Battery data
Number of batteries2
Battery typeLi-ion
Weight of battery0.157 kg (0.346 lb)
Page 5
5 | DSA E-Series 4TB (E2700)
Battery casingPack
Battery groupAccumulator
System hardware specifications
ChassisDSA E2700 controller-drive tray
conforms to the 483 mm
(19.0 in) rack standard
Power suppliesDual redundant, hot pluggable
Maximum disk drives12 x 4 TB, 3.5”, Nearline SAS
Maximum net capacity40964 GB (RAID‑5 configured)
DDR2 memory (system RAM)4 GB
Integrated I/O2 x 100 Mbps management port;
2 x 1/10 Gigabit Ethernet, copper
Remote management (via LAN)Yes (plus serial console on
dedicated port)
Mechanical
Dimensions (H x W x D)
• Controller-drive tray86.4 x 482.6 x 552.5 mm
(3.4 x 19 x 21.75 in)
• Shipping carton241.3 x 584.2 x 685.8 mm
(9.5 x 23 x 27 in)
Weight
• Maximum weight24.9 kg (54.9 lb) Simplex
Controller
27 kg (59.52 lb) Dual Simplex
Controller
• Maximum shipping weight29.65 kg (65.37 lb) Simplex
Controller
31.75 kg (70.0 lb) Dual Simplex
Controller
Relative humidity (non-condensing)
• Operating range (both
cabinet and subsystem)
• Storage range10 to 90%
Acoustic noise
• Sound power (standby
operation)
• Sound pressure (normal
operation)
20 to 80%
65 dB max
65 dBA max
12-bay expansion unit 12 x 4 TB (DSX‑N1D6X4‑12AT)
Electrical requirements—expansion unit
ParameterLow rangeHigh range
Nominal voltage100 VAC240 VAC
Frequency50 to 60 Hz50 to 60 Hz
Idle current2.96 A1.23 A
Maximum operating
current
Sequential drive
group spin up
Simultaneous drive
spin up
System rating plate
label
Power ratings—expansion unit
KVA0.276
AC Watts276
BTU/h954
3.03 A1.26 A
4.23 A1.76 A
4.43 A1.83 A
7.0 A2.9 A
Space requirements
Front—cooling760 mm (30 in) clearance in front
Rear—cooling610 mm (24 in) clearance behind
Front of chassis—maintenance760 mm (30 in) clearance in front
Rear of chassis—maintenance610 mm (24 in) clearance behind
Environmental
Temperature
• Operating range (both
cabinet and subsystem)
• Maximum rate of change10 °C (50 °F) per hour
• Storage range-10 °C to +50 °C (+14 °F to
of the cabinet
the cabinet
of the cabinet
the cabinet
+10 °C to +40 °C (+50 °F to
+104 °F)
+122 °F)
Note: for detailed information please see the NetApp E‑Series Storage
Systems Site Preparation Guide
System hardware specifications—expansion unit
ChassisDE1600 controller-drive tray
conforms to the 483 mm
(19.0 in) rack standard
Power suppliesDual redundant, hot pluggable
Maximum disk drives12 x 4 TB, 3.5”, Nearline SAS
Maximum net capacity40964 GB (RAID‑5 configured)
Integrated I/O6 Gb SAS
Mechanical—expansion unit
Dimensions (H x W x D)
• Drive tray86.4 x 482.6 x 552.5 mm
(3.4 x 19 x 21.75 in)
Page 6
6 | DSA E-Series 4TB (E2700)
• Shipping carton241.3 x 584.2 x 685.8 mm
Weight
• Maximum weight27 kg (59.52 lb)
• Maximum shipping weight31.75 kg (70.0 lb)
Space requirements
Front—cooling760 mm (30 in) clearance in front
Rear—cooling610 mm (24 in) clearance behind
Front of chassis—maintenance760 mm (30 in) clearance in front
Rear of chassis—maintenance610 mm (24 in) clearance behind
Environmental—expansion unit
Temperature
• Operating range (both
cabinet and subsystem)
• Maximum rate of change10 °C (50 °F) per hour
• Storage range-10 °C to +50 °C (+14 °F to
(9.5 x 23 x 27 in)
of the cabinet
the cabinet
of the cabinet
the cabinet
+10 °C to +40 °C (+50 °F to
+104 °F)
+122 °F)
BTU/h4180
Note: for detailed information please see the NetApp E‑Series Storage
Systems Site Preparation Guide
System hardware specifications—expansion unit
ChassisDE6600 controller-drive tray
conforms to the 483 mm
(19.0 in) rack standard
Power suppliesDual redundant, hot pluggable
Maximum disk drives60 x 4 TB, 3.5”, Nearline SAS
Maximum net capacity204820 GB (RAID‑5 configured)
Integrated I/O6 Gb SAS
Mechanical—expansion unit
Dimensions (H x W x D)
• Drive tray177.8 x 482.6 x 825.5 mm
(7.0 x 19 x 32.5 in)
• Shipping carton482.6 x 609.6 x 1009.7 mm
(19 x 24 x 39.75 in)
Weight
• Maximum weight105.2 kg (232 lb)
• Maximum shipping weight193.2 kg (426 lb)
Relative humidity (non-condensing)
• Operating range (both
cabinet and subsystem)
• Storage range10 to 90%
Acoustic noise
• Sound power (standby
operation)
• Sound pressure (normal
operation)
20 to 80%
65 dB max
68 dB max
60-bay expansion unit 60 x 4 TB (DSX‑N6D6X4‑60AT)
Electrical requirements—expansion unit
ParameterLow rangeHigh range
Nominal voltage220 VAC240 VAC
Frequency50 to 60 Hz50 to 60 Hz
Idle current6.0 A6.0 A
Maximum operating
current
Power ratings—expansion unit
KVA1.268
7.56 A7.56 A
Space requirements
Front—cooling760 mm (30 in) clearance in front
of the cabinet
Rear—cooling610 mm (24 in) clearance behind
the cabinet
Front of chassis—maintenance760 mm (30 in) clearance in front
of the cabinet
Rear of chassis—maintenance610 mm (24 in) clearance behind
the cabinet
Environmental—expansion unit
Temperature
• Operating range0 °C to +35 °C (+32 °F to +95 °F)
• Maximum rate of change10 °C (50 °F) per hour
• Storage range-10 °C to +50 °C (+14 °F to
+122 °F)
Relative humidity (non-condensing)
• Operating range20 to 80%
• Storage range10 to 90%
Acoustic noise
AC Watts1222
Page 7
7 | DSA E-Series 4TB (E2700)
• Sound power (standby
operation)
• Sound pressure (normal
operation)
65 dB max
68 dB max
Notes:
General technical information for the RAID systems are
provided in the NetApp E‑Series Storage Systems Site
Preparation Guide (Information Web: http://
www.netapp.com; Part number: 215-09029_A,
December 2014)
NetApp, AutoSupport, and SANtricity are registered trademarks of NetApp, all rights
reserved. All data and dimensions are referenced from the NetApp Site Preparation Guide
and from the NetApp Website and are subject to change without notice.
Ordering information
DSA E-Series Simplex Controller, 12 x 4 TB
High-performance, high-capacity storage system base
unit, iSCSI disk array, 12 x 4 TB HDD
Order number DSA-N2E7X4-12AT
DSA E-Series Dual Simplex Controller, 12 x 4 TB
High-performance, high-capacity storage system base
unit, iSCSI disk array, 12 x 4 TB HDD, dual controller
Order number DSA-N2C7X4-12AT
Non-returnable disk, 12-bay 4/6 TB
12-month non-returnable disk option for DSA E2700
4 TB or 6 TB based 12-bay controller or expansion
units, available for in-warranty systems only
Order number DSA-S2E7X46-NRD
SupportEdge Standard extension, 60-bay 4/6 TB
12-month extension of SupportEdge Standard next
business day for DSA E2700 4 TB or 6 TB based 60-bay
expansion units, available for a 4th and a 4th/5th year as
a standard
Order number DSA-S6D6X46-SLE
Parts replacement, 60-bay 4/6 TB
12-month service uplift to SupportEdge Standard:
parts replacement within 4 hours for DSA E2700 4 TB
or 6 TB based 60-bay expansion units, available for inwarranty systems only
Order number DSA-S6D6X46-4PR
Non-returnable disk, 60-bay 4/6 TB
12-month non-returnable disk option for DSA E2700
4 TB or 6 TB based 60-bay expansion units, available
for in-warranty systems only
Order number DSA-S6D6X46-NRD
DSA E-Series 12-bay expansion unit, 12 x 4 TB
High-performance, high-capacity storage system
expansion unit, iSCSI disk array, 12 x 4 TB HDD
Order number DSX-N1D6X4-12AT
DSA E-Series 60-bay expansion unit, 60 x 4 TB
High-performance, high-capacity storage system
expansion unit, iSCSI disk array, 60 x 4 TB HDD
Order number DSX-N6D6X4-60AT
Accessories
DSA E-Series storage expansion 4 TB
4 TB HDD
Order number DSA-EDTK-400A
DSA E-Series rack
Empty rack, 40U
Order number DSX-NRCK40-INT
Services
SupportEdge Standard extension, 12-bay 4/6 TB
12-month extension of SupportEdge Standard next
business day for DSA E2700 4 TB or 6 TB based 12-bay
controller or expansion units, available for a 4th and a
4th/5th year as a standard
Order number DSA-S2E7X46-SLE
Parts replacement, 12-bay 4/6 TB
12-month service uplift to SupportEdge Standard:
parts replacement within 4 hours for DSA E2700 4 TB
or 6 TB based 12-bay controller or expansion units,
available for in-warranty systems only
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com