Bosch DS940Q Installation Instructions Manual

DS940Q
Passive Infrared Detector
Installation Instructions
1.0 Description
The DS940Q is a high performance Passive Infrared (PIR) Motion Detector which uses advanced signal processing to provide outstanding catch performance and unsurpassed false alarm immunity. It is designed to detect movement in the interior of a structure by sensing the Infrared energy emitted from the human body as it moves across the detector’s field of view. When motion is detected, the detector sends an alarm signal to the Control Panel.
Input Power: 9-15 volts DC
Current Draw: 12 mA @ 12 VDC standby and alarm
Standby Power: No internal standby power. For UL Listed Product
Installations, 4 hours (48 mA-h) standby power must be provided.
Relay Form “A” Normally Closed (NC) contact set rated for 125 mA @ 28 volts maximum DC or 18 volts maximum AC for resistive loads.
Tamper: Normally Closed (with cover on). Contacts rated at 28 VDC, 125 mA max. Connect tamper circuit to a 24-hour protection circuit.
3.0 Installation
3.1 Remove the cover using a
small flat-blade screwdriver.
Bottom of Detector
3.2 Press the vertical adjust tab
toward the side of the case and lift out the board.
7.5-9ft
Temperature: -20°F to +120°F (-29°C to +49°C). For UL Listed Product Installations, the temperature range is +32°F to +120°F (0°C to +49°C).
Humidity: 0 - 95% non-condensing.
Dimensions: 3.75 in. x 2.25 in. x 1.5 in. (HxWxD) (9.5 cm x 5.7 cm x 3.8 cm)
Options: B335 Swivel Mount Bracket. Use of this bracket may decrease the PIR range and increase dead zones.
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security Systems, Inc. Web site at: http://www.boschsecurity.com/
datecodes/
3.3 Select a mounting location.
Mount the sensor where an intruder will most likely cross through the coverage pattern.
LED ON
OFF
Insert screwdriver he re o r he re
3.3 Avoid:
Direct Hot or Cold Drafts
Air Conditioning
Outlets
Windows
and
Uninsulated
Direct Sunlight
Walls
Moving Objects
Heat Sources
3.4 Position detector at correct height.
Mounting Outdoors
7.5 -9 ft .
(2.3- 2.7 m)
Pets
Mount the detector 7. 5 - 9 feet
(2.3 - 2.7 meters) above the floor
3.6 Mount the unit, using the appropriate mounting holes.
Thinwall knockouts
for wiring
Corner Mount
Note: To avoid
possible circuit board damage, use only the mounting hardware provided in the appropriate punch-out mounting holes.
3.7 Install the board into the case. Be sure the vertical adjust tab aligns with the correct mounting height.
LED ON
OFF
3.8 Wire the Detector.
9-15 VDC
-
+
Surface
Mount
Remove
Areas
if using th e
B335 Bracket
Don't overtighten the mounting screws
Cover may not attach correctly
3.9 Select LED Operation
LED
7.5-9ft
ON
OFF
ON
ON
OFF
7.5-9ft
7.5-9 ft = 2.3-2.7 m
3.10 If look-down is desired, peel away the look-down mask. Do
not remove the clear plastic lens.
LED ON OFF
7.5-9ft
Peel away
the mask
7.5-9ft
LED
ON
4.0 Walk test at the time of installation and annually thereafter.
This detector contains an environmental stabilization circuit which requires approximately 2 minutes after initial power-up to warm up. During this time the detector will not respond to any movement.
5.0 Coverage Patterns
012
Meters
20
10
0
10
20
© 2011 Bosch Security Systems, Inc. 130 Perinton Parkway, Fairport, New York 14450 www.boschsecurity.com
1-1112-2223-3334-4445-5556-6667-
Feet
040
10
20 30
77
Please wait 2 minutes after initial power-up to
6
012
10
Meters
perform any walk tests.
3
7.5
0
Feet
040
0
Look
Down
6
1-1112-2223-
Although generally not required, if masking is desired, the lens diagram shows the appropriate areas to be masked (see shaded area on the DS940Q lens diagram). Use an opaque material (such as, electrical tape) to mask the desired areas.
33
34-
44
55
56-
66
45-
DS940Q Installation Instructions
P/N: F01U035308-07 Page 2
0
67-
77
1234567891011
12 22 23 33 34 44 45 55 56 66
67 77
DS940Q Lens (inside view)
2/11
Loading...