Bosch DS7460I Installation Manual

Installation Instructions
for the
DS7460i Dual Zone Input Module
1.0 Description
The DS7460i is a Dual Zone Input Module designed to operate with compatible multiplex systems. It provides two supervised input zones for connection of conventional normally open or normally closed contacts. Each DS7460i occupies two multiplex zone addresses on the system and can monitor up to two separate zones. The DS7460i connects to the DS7430 or DS7436 Multiplex Expansion Modules or the D8125MUX Multiplex Expansion Module.
For additional information about installing the DS7460i, refer to the
D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639).
2.0 Specifications
The D7460i is compatible with the D8125MUX
(P/N: F01U034973).
Voltage: 12 VDC nominal
Current: 1 mA maximum
Line Impedance:
Maximum Impedance: 4.05Ω at
+68°F (+20°C) nominal
Maximum Distance Size
250 ft 22 AWG 600 ft 18 AWG
76 m 0.65 mm
193 m 1.02 mm
Fire applications require 18 AWG.
Operating Temperature Range: +32°F to +122°F (0°C to +50°C)
Signaling Line Circuit Type: Class B (S tyle 4)
Initiating Device Circuit Type: Class B (S tyle A)
Relative Humidity: 0 to 93%
When used in a fire alarm system, NFPA 72 prohibits this product from sharing a communication bus with non-fire devices.
3.0 Programming
Consult the intended control panel's installation guide for multiplex zone (point) programming information.
Each DS7460i will require two multiplex addresses.
Program the control panel (or D8125MUX) as described in the control panel's reference guide.
Disconnect power to the panel before running wires to
connect the DS7460i.
After any programming or hardware change, do a
functional test of the system as required by local codes.
Remove the cover of the DS7460i. Press in and up with your thumb and nail directly above the lip of the DS7460i (see Figure 1).
Figure 1: Removing the Cover
Remove the DS7460i circuit board from the base. Press the circuit board retainer tab and pull the circuit board up and out of the base (see Figure 2).
Address
Switches
O
1 2 3 4 5 6 7 8
N
Reed Switch
Circuit Board Retaine r Tab
Wire
Entrance
Terminal Strips
Tamper
Switch
Figure 2: Removing the PCB
Handle this and all circuit boards carefully. Hold the board
by its edges.
Route the wiring through the wire entrance of the DS7460i base.
Mount the DS7460i base to the mounting surface using the supplied screws.
Return the DS7460i circuit board to the base.
5.0 Wiring
DS7460i Terminals Description
2 Protection Zone 2 Input
G Protection Zone Ground (Common)
1 Protection Zone 1 Input
- Multiplex Bus Negative
+ Multiplex Bus Positive
Table 1: DS7460i Terminal Descriptions
See page 3 for switch settings.
4.0 Installation
These Installation Instructions assume the control panel is installed and in proper working condition.
The control panel (or D8125MUX) must be programmed and the DS7460i address switches must be set for the DS7460i to operate.
The input zones are power limited and supervised.
When used in fire applications, Normally Open contacts
must be used on the input zones.
Connect wiring to the DS7460i as shown in Figures 4-6. Protection zones are designed to monitor Normally Open or Normally Closed dry contacts. They are supervised using 47 kilohm end-of­line resistors.
Figure 3: Location of magnet
5.3 D8125MUX Multiplex Expansion Module Wiring
Use 47K ohm EOL P/N:26069
for non-fire applications.
Use 47K ohm EOL P/N:28010
for fire applications.
Zone 2+
Ground
Zone 1+
Multiplex Bus -
Multiplex Bus +
DS7460i
N/O
N/O
N/C
N/C
Supervised
PWR+ PWR- BUS+ BUS- PWR+ PWR- BUS+ BUS-
DS7436
Either Bus A or Bus B,
or both, may be used. Refer
to the panel ’ s referenc e g u ide.
Zone 1 may be used as a magnetic contact by mounting a magnet in conjunction with the reed switch and removing the EOL resistor for Zone 1. Zone 1 may not be used as a magnetic contact and used to monitor other contacts at the same time.
It may be desirable to cut the reed switch from the DS7460i circuit board if it is not being used. This will eliminate possible tampering to override Zone 1 operation. For fire installations, order Multiplex Fire Zone EOL P/N: 28010 in the quantity needed.
5.1 DS7430 Multiplex Expansion Module Wiring
Use 47K ohm EOL P/N:26069
for non-fire applications.
Use 47K ohm EOL P/N:28010
for fire applications.
DS7430
Power Bus
Zone 2+
Ground
Zone 1+
Multiplex Bus -
Multiplex Bus +
DS7460i
Alarm Contact
(Normally Open or
Normally Closed)
N/C
N/O
N/O
N/C
Figure 6: Wiring the D8125MUX Multiplex Expansion Module
For UL Listed fire installations, Normally Open (N/O)
contacts must be used.
6.0 Switch Settings
Set the address switch settings before connecting the DS7460i to the multiplex bus.
No two DS7460i Dual Zone modules may be set to the same address. Having two or more units set to the same address may prevent fault detection or cause multiplex bus failure.
Address
Switches
O
1 2 3 4 5 6 7 8
N
O
In the switch settings chart
= ON
1 2 3 4 5 6 7 8
N
Figure 4: Wiring using a DS7430 Multiplex Expansion Module
Figure 7: Address Switches
5.2 DS7436 Multiplex Expansion Module Wiring
Use 47K ohm EOL P/N:26069
for non-fire applications.
Use 47K ohm EOL P/N:28010
for fire applications.
Zone 2+
Ground
Zone 1+
Multiplex Bus -
Multiplex Bus +
DS7460i
N/O
N/O
Note: Do not loop wires around the terminals.
N/C
N/C
D8125 Multiplex Module
POWER A
MUX BUS A
+- +- + - +-
to the panel’s reference guide.
POWER B
MUX BUS B
Either Bus A or Bus B,
or both, may be used. Refer
You can find the Address Switch Settings using the chart on this page, or by calculating the decimal number of the address.
O
1234 56 78
N
128 64 32 16 8 4 2 1
Binary Switch Values (P oint 17 sho wn )
Zone (Point) addresses 001-008 may not be used for multiplex zones on the DS7400Xi.
Figure 5: Wiring using a DS7436 Multiplex Expansion Module
Page 2 © 2009 Bosch Security Systems, Inc. DS7460i Installation Instructions
Loading...
+ 2 hidden pages