Bosch DS160, DS161 Specsheet

Intrusion Alarm Systems | DS160 Series High Performance Request‑to‑exit Detectors
DS160 Series High Performance Request‑to‑exit Detectors
www.boschsecurity.com
u Door monitor with sounder alert
u Sequential Logic Input (SLI)
The DS160 Series consists of the DS160 Detector (light gray) and the DS161 Detector (black) specifically designed for Request-to-exit (REX) applications. With features such as timers, door monitor with sounder alert, and pointable coverage, the DS160 and DS161 have the flexibility to meet the most stringent REX requirements. The exclusive Sequential Logic Input (SLI) provides added security that is not offered in any other REX device.
Functions
Sequential Logic Input (SLI)
The SLI terminal allows connection of a second device to require sequential detection. This eliminates the possibility that an object that is slid through the door or underneath the door will activate the detector. This input can also be used to lock the sensor if motion is present outside the premises.
Door Monitor
The sensor can monitor a door contact to allow special control of the internal relay. For example, if the door is opened within the relay time period, the sensor can be programmed to halt the timer. If the door is not opened within a specific time period, the relay can be programmed to deactivate.
u Wrap-around coverage pattern with precise pattern
control
u Up to 64 second adjustable latch time
Sounder Alert
An integrated sounder can be programmed to activate if the door is left open too long. The sounder volume is fully adjustable to 85 dB.
Keycard Input
The keycard input allows the sensor relay to be controlled from an external source, such as an access control system or card reader.
Certifications and approvals
Europe Complies with EN50131‑1 Grade 2
Region Certification
Australia RCM [DS160]
Europe CE 2004/108/EC EMC Directive;
2006/95/EC Low-Voltage Directive; 2011/65/EU Restriction of the use of certain hazardous substances in electri­cal and electronic equipment
USA UL ALVY: Access Control Systems Units
(UL294)
ALARM WILL
SOUND WHEN
DOOR IS OPENED
3 m
(10 ft)
ALARM WILL
SOUND WHEN
DOOR IS OPENED
1.2 m (4 ft)
1.5 m (5 ft)
3 m
(10 ft)
.75 m
(2.5 ft)
1.5 m (5 ft)
2 | DS160 Series High Performance Request‑to‑exit Detectors
Installation/configuration notes
Front View Mounted on wall above door and mounted on ceiling . 75 m (2.5 ft) in front of the door.
The higher that you mount the unit, the larger the coverage area. Do not mount the DS160/DS161 more than 4.6 m (15 ft) above the floor. Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed straight down.
Coverage Information
The coverage (detection area) varies depending on the mounting height above the floor, angle of the lens, and whether the unit is mounted on a wall above the door or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x 10 ft) The coverage patterns for the detector at a height of 2.3 m (7.5 ft) are shown. The coverage pattern increases or decreases with height and detector alignment.
Notice
When you mount the unit on the wall and the lens points straight down, some detection zones point toward the wall and do not detect movement.
The diagrams depict views of the coverage pattern with the detector mounted at 2.3 m (7.5 ft) above the floor with the lens pointed straight down. Zones that are pointed toward the wall are not shown.
Side View The higher that you mount the unit, the larger the coverage area. Do not mount the DS160/DS161 more than 4.6 m (15 ft) above the floor. Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed straight down.
Technical specifications
Environmental
Operating Temperature:
-29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F)
Radio Frequency Interference (RFI) Immunity:
No alarm or setup on critical frequencies in the range from 26 MHz to 1000 MHz at 50 V/m
Complies with Environmental Class II (EN50130-5)
Mechanical
Dimensions: 4.5 cm x 17.1cm x 4.4 cm
(1.80 in. x 6.75 in. x 1.75 in.)
Material: High impact ABS plastic enclosure
Modes
Power Loss
Programmable fail-safe or fail-secure modes.
Default:
Timer: Programmable reset accumulative or non-reset
counting mode.
Electrical
Current Draw: 8 mA nominal standby current, 39 mA at 12 VDC in
alarm
Side View
Voltage: 12 VAC or VDC to 30 VAC or VDC
Alarm Output: Two Form C relay contacts each rated 1 A at 30 VAC
or VDC for resistive loads