SPLIT-TYPE ROOM AIR CONDITIONER
BOSCH CLIMATE 8000 RAC
All Model Numbers
Read this manual carefully before installing or operating your new air conditioning unit.
Ma
ke sure to save this manual for future reference.
Installation Manual 6 720 869 159 (2016/12)

2 Installation Summary - Indoor Unit 8
4 Indoor Unit Installation 11
1. Select installation location .......................................... 11
2. Attach mounting plate to wall ...................................... 12
3. Drill wall hole for connective piping .............................. 12
4. Prepare refrigerant piping ........................................... 14
5. Connect drain hose ...................................................... 15
6. Connect signal cable .................................................. 17
7 Wping and cables ...................................................... 18
8. Connect indoor power wire ......................................... 18
9. Mount indoor unit ...................................................... 18
5 Outdoor Unit Installation 20
1. Select installation location ..................................... 20
2. Install drain joint ................................................... 21
3. Anchor outdoor unit .............................................. 22
4. Connect signal and power cables .............................. 23
6 720 869 159 (2016/12) Installation Manual

6 Refrigerant Piping Connection .................... 25
A. Note on Pipe Length ................................................. 25
B. Connection Instructions –Refrigerant Piping ................ 25
1. Cut pipe ............................................................ 25
2. Remove burrs .................................................... 26
3. Flare pipe ends .................................................. 26
4. Connect pipes ................................................... 27
7 Air Evacuation .................... 29
1. Evacuation Instructions .................. 29
2. Note on Adding Refrigerant .............. 30
8 Electrical and Gas Leak Checks ............ 31
9 Test Run ........................................... 32
10 European Disposal Guidelines ............. 34
Installation Manual 6 720 869 159 (2016/12)

4 | Safety Precautions
Safety Precautions
Read Safety Precautions Before Installation
Incorrect installation due to ignoring instructions can cause serious damage or injury.
The seriousness of potential damage or injuries is classified as either a WARNING or CAUTION.
This symbol indicates that ignoring instructions may cause serious injury.
This symbol indicates that ignoring instructions may cause moderate injury to your person, or damage to
your unit or other property.
This symbol indicates that you must never perform the action indicated.
modify the length of the power supply cable or use an extension cord to power the unit.
share the electrical
outlet with other appliances. Incorrect or insufficient power supply can cause fire or electrical shock.
When connecting refrigerant piping,
let substances or gases other than the specified refrigerant enter the unit. The
presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high pressure in the
refrigeration cycle. This can cause explosion and injury.
allow children to play with the air conditioner. Children must be supervised around the unit at all times.
1. Installation must be performed by a qualified persons. Defective installation can cause water leakage, electrical shock, or fire.
2. Installation must be performed according to the installation instructions. Incorrect installation can cause water leakage,
electrical shock, or fire.
3. Contact an authorised service technician for repair or maintenance of this unit.
4. Only use the included accessories, parts, and specified parts for installation. Using non-standard parts can cause water
leakage, electrical shock, fire, and can cause the unit to fail.
5. Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot support the unit’s weight, or
the installation is not done properly, the unit may fall and cause serious injury and damage.
6 720 869 159 (2016/12) Installation Manual

6. For all electrical work, follow all local and national wiring standards, regulations, and the Installation Manual. You must use an
independent circuit and single outlet to supply power. Do not connect other appliances to the same outlet. Insufficient
electrical capacity or defects in electrical work can cause electrical shock or fire.
7. For all electrical work, use the specified cables. Connect cables tightly, and clamp them securely to prevent external forces
from damaging the terminal. Incorrect electrical connections can overheat and cause fire, and may also cause shock.
8. All wiring must be properly arranged to ensure that the control board cover can close properly. If the control board cover is not
closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause
electrical shock.
9. In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is
highly recommended.
install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the
unit, it may cause fire.
operate your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause
electrical components to short circuit.
1. The product must be properly grounded at the time of installation, or electrical shock may occur.
2. Install drainage piping according to the instructions in this manual. Improper drainage may cause water damage to your home
and property.
Note about Fluorinated Gasses
1. This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and the amount, please refer
to the relevant label on the unit itself.
2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
3. Product uninstallation and recycling must be performed by a certified technician.
4. If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months.
5. When the unit is checked for leaks, correct and accurate record-keeping of all checks is strongly recommended.
Installation Manual 6 720 869 159 (2016/12)

1. Accessories
The air conditioning system comes with the following accessories. Use all of the installation parts and accessories to install the air
conditioner. Incorrect installation may result in water leakage, electrical shock and fire, or cause the equipment to fail.
Mounting plate fixing screw ST3.9 X 25
Fixing screw for remote controller holder
ST2.9 x 10
1
(for cooling & heating models only)
6 720 869 159 (2016/12) Installation Manual

Remote controller illustration
1
Installation Manual 6 720 869 159 (2016/12)

8 | Installation Summary - Indoor Unit
2. Installation Summary - Indoor Unit
6 720 869 159 (2016/12) Installation Manual

Installation Summary - Indoor Unit | 9
Installation Manual 6 720 869 159 (2016/12)

NOTE ON ILLUSTRATIONS
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual
6 720 869 159 (2016/12) Installation Manual

Indoor Unit Installation | 11
4. Indoor Unit Installation
Installation Instructions - Indoor Unit
Before installing the indoor unit, refer to the label on the product box to
make sure that the model number of the indoor unit matches the model
number of the outdoor unit.
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate
location. The following are guidelines that will help you choose an
appropriate location for the unit.
following guidelines with help ensure a better installation and user
experience:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid—the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices
(e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might block air circulation
Near the doorway
In a location subject to direct sunlight
If there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room
for a wall hole (see
Drill wall hole for connective piping step)
for the
signal cable and refrigerant piping that connect the indoor and outdoor
units. The default position for all piping is the right side of the indoor unit
(while facing the unit). However, the unit can accommodate piping to
both the left and right.
Installation Manual 6 720 869 159 (2016/12)