Bosch CDi User Manual

CDi Series
Engineering
Model SM - Split System Residential Geothermal Heat Pump
Overview and Certifi cations
Condenser Section
Submittal
Sheet
2013
Compact Air Handler/Fan Coil
Standard Features, Factory Installed Options, and Field Installed Accessories
Standard Features for Condenser Section
White Pre-Painted Sheet Metal Cabinets
Appliance white for a clean - durable look — Door handles - for easy removal for service — Indoor or outdoor installation for condenser section
High Efficiency
Up to 32.7 EER and 5.0 COP @ PL GWHP — Up to 26.5 EER and 5.2 COP @ FL GWHP with Bosch
Model DX Fan Coil Section
Closed Cell (Fiber Free) Insulation
Lowers unit sound levels
Patent Pending Floating Base Pan
Lowers sound levels to whisper quiet operation
Factory installed swivel fi ttings
Scroll two capacity compressor
Better comfort control when match with a Bosch
Communicating Thermostat
Two capacities compressor helps to match the
structures heat gain or heat loss
Reliability - Durability - Serviceability
Alert communicating circuit board — Completely serviceable from front of unit
Electronic Circuit Board
Low pressure switch protection — High pressure switch protection — Alarm output — Anti-short cycling — 5 Minute delay — Low pressure bypass at start up — Random start of unit — Brown out protection
Freeze Sensor
Standard Warranty
10 Year all parts limited warranty — 10 Year labor limited warranty
1 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Standard Features, Factory Installed Options, and Field Installed Accessories continued..
Engineering Submittal Sheet
Factory Installed Options for Condenser Section
Cupro-nickel Coil:
Recommended in conditions anticipating moderate
scale formation or in brackish water/well water
SmartStart:
A factory installed start up device that improved start
up effieciency as much as 65% and helps reduce wear and tear on the compressor during start up
Comfort Alert Module:
This module can be added for additional diagnostic
features
Fluid Differential Pressure Switch
Prevents the unit refrigerant pressure switches to fault
out
Pump Interlock Relay
Helps ensure the external flow/pump center operates
when unit is operating
Closed Cell Foam Insulation
For whisper quiet operation — Not recommended for outdoor installation
Domestic Hot Water Generator/Heat Recovery Package/
Desuperheater
This option can supplement your hot water needs
Standard Features for SM Fan Coil Section
Electronically Commutative Motor
Constant CFM Variable Speed ECM
Closed Cell (Fiber Free) Insulation
Less than 2% Air Leakage Rate — Improved Indoor Air Quality
Dehumidification:
Lowering the humidity in your home allows you to
turn up the thermostat in the summer and save you on operational costs; accomplished with a Bosch communicating thermostat
Tin Plated Copper Tubing with Aluminum Fins
This will protect the evaporator coil from most forms of
corrosive elements in the airstream
Factory Installed Options for SM Fan Coil Section
Internal Electric Heat:
Can be factory mounted or field installed. Choices
include 5, 10, 15, or 20 kilowatt back up or an emergency heater depending on the size of the geothermal heat pump
Field Installed Accessories for All
Thermostats:
Bosch thermostats are fully customized to meet your
individual needs. True Communicating thermostat that displays the alert messages without having to go to the unit
Photo-Catalytic Oxidizers (PCO):
Refreshes and cleans the air in your home by
converting Volatile Organic Compounds and other gases into harmless water vapor and CO2
Humidifiers:
Bosch humidifiers release moisture into the air while
helping to seal windows and doors tightly
Smoke Detection:
In case of a fire, prevents smoke from spreading from
room to room
Fresh Air Dampers:
Helps to prevent home from going into a negative
pressure situation
Carbon and Potassium- Permanganate Filters:
Helps to remove gases, odors, and other volatile
organic compounds by trapping them in mesh
DDC Control
DX Air Handler/Fan Coil
The Bosch DX fan coil is a full size fan coil for indoor
use — Delivers the highest combined efficiencies — Constant CFM Variable Speed ECM
DX Evaporator Coil
The Bosch DX Evaporator Coil is a great addition to
add to a Hybrid System — Fits most manufacturers furnace opens — Delivers the highest combination efficienceis
2 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Engineering Submittal Sheet
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Condenser Model Nomenclature
SM 024 - 1 CS C - F
SERIES WATER CONNECTIONS
SM F - Front
SIZE
024 C - Copper 036 N - Cupro-Nickel 048 060 070 CS - Condensing Section
COAX OPTIONS
CABINET CONFIGURATION
VOLTAGE DESIGNATIONS
1
- 208/1/60 & 230/1/60
Fan Coil Model Nomenclature
SM 024 - 1 AV X - X L T A
SERIES
SM A - Constant Airflow ECM
SIZE DISCHARGE AIR CONFIGURATION
024 T - Top (AV only) 036 048 E - End (AH only) 060 070
VOLTAGE DESIGNATIONS
1
- 208/1/60 & 230/1/60 X - None
FAN MOTOR OPTIONS
S - Straight (AH only)
RETURN AIR CONFIGURATION
L - Left R - Right
CABINET CONFIGURATION Not Used for Air Handlers
AH - Air Handler Horizontal AV - Air Handler Vertical
Bosch Thermotechnology Corp.
3 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Londonderry, NH • Ft. Lauderdale, FL
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
ASHRAE/AHRI/ISO 13256-1. English (I-P) Units
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Models GPM Load
SM024
SM036
SM048
SM060
SM070
6
Partial 18500 16.1 22700 5.6 20900 25.6 18300 4.6 19800 22.2 15500 3.9
9
Partial 26800 18.8 32000 6.1 30500 33 25900 5.1 29300 27.4 22800 4.5
12
Partial 35500 17.6 41000 5.8 39500 30.5 33400 4.8 38200 25.4 29200 4.3
15
Partial 43700 17 52900 5.2 48600 28 43000 4.5 47200 24.1 37800 4
18
Partial 51300 15 62300 5 56600 23.5 50000 4.2 55300 20.4 44800 3.8
Cooling
Capacity
(Btu/hr)
Full 23800 14.1 29800 4.8 27100 20.6 24600 4.2 25300 16.2 19100 3.5
Full 36900 16.2 44000 5.2 41100 24 36300 4.7 38800 18.8 28600 4.1
Full 48000 15.4 56100 5.2 53400 23.1 45800 4.5 49400 17.7 35900 3.8
Full 58100 14.6 72900 4.7 64100 20.6 59200 4.3 60200 16.4 46400 3.6
Full 65200 13.1 80500 4.4 71600 18.6 66400 3.9 67500 14.9 52900 3.4
ASHRAE/AHRI/ISO 13256-1. English (I-P) Units
Fan coil/Air
handler or
Models
Evaporator
Load GPM
Coil Model
Number
DX025-1VTX F 6 23800 14.1 29800 4.8 27100 20.6 24600 4.2 25300 16.2 19100 3.5
DX025-1VTX P 6 18500 16.1 22700 5.6 20900 25.6 18300 4.6 19800 22.2 15500 3.9
SM024-1CS
SM036-1CS
SM048-1CS
SM060-1CS
SM070-1CS
DX035-1VTX F 6 26200 17.4 29000 5.7 29100 26.5 23900 5 27100 20.1 18700 4.2
DX035-1VTX P 6 19600 19.4 22500 6.5 21600 32.7 17800 5.2 21000 28 15500 4.5
DX025-CC/UC F 6 23200 13.9 30500 5 26500 20.5 25300 4.4 24700 16.1 19800 3.6
DX025-CC/UC P 6 18000 16 23200 5.8 20500 26.3 18800 4.7 19400 22.1 15800 4
DX035-1VTX F 9 36900 16.2 44000 5.2 41100 24 36300 4.7 38800 18.8 28600 4.1
DX035-1VTX P 9 26800 18.8 32000 6.1 30500 33 25900 5.1 29300 27.4 22800 4.5
DX049-1VTX F 9 36900 16.7 43100 5.4 42000 25.4 35600 4.8 38600 19.4 28000 4.2
DX049-1VTX P 9 27100 19.3 31400 6.3 30900 34.6 25400 5.3 29400 28.5 22000 4.7
DX035-CC/UC F 9 36000 15.2 45000 5.1 40200 22.4 37200 4.6 37800 17.7 29600 4
DX035-CC/UC P 9 26100 17.2 32800 5.8 29700 29.3 26600 4.9 28600 24.7 23500 4.4
DX049-1VTX F 12 48000 15.4 56100 5.2 53400 23.1 45800 4.5 49400 17.7 35900 3.8
DX049-1VTX P 12 35500 17.6 41000 5.8 39500 30.5 33400 4.8 38200 25.4 29200 4.3
DX049-CC/UC F 12 46500 14.4 57600 5.1 51900 21.3 47300 4.5 47900 16.5 37400 3.8
DX049-CC/UC P 12 34500 16.1 42100 5.6 38500 27.1 34400 4.7 37100 22.8 30300 4.1
DX061-1VTX F 15 58100 14.6 72900 4.7 64100 20.6 59200 4.3 60200 16.4 46400 3.6
DX061-1VTX P 15 43700 17 52900 5.2 48600 28 43000 4.5 47200 24.1 37800 4
DX071-1VTX F 15 58700 14.5 70800 4.8 64900 20.4 59100 4.4 60800 16.4 47000 3.7
DX071-1VTX P 15 43700 17.3 51700 5.4 49000 28.6 42700 4.6 47300 24.4 37900 4.2
DX061-CC/UC F 15 56500 13.9 74600 4.8 62500 19.8 60900 4.3 58600 15.8 48100 3.6
DX061-CC/UC P 15 42500 15.7 54200 5.1 47400 25.4 44200 4.4 46000 21.9 39000 3.9
DX071-1VTX F 18 65200 13.1 80500 4.4 71600 18.6 66400 3.9 67500 14.9 52900 3.4
DX071-1VTX P 18 51300 15 62300 5 56600 23.5 50000 4.2 55300 20.4 44800 3.8
DX071-CC/UC F 18 63400 12.9 82300 4.5 69900 18.5 68200 4 65800 14.7 54700 3.5
DX071-CC/UC P 18 49900 14.3 63700 5 55200 22.6 51400 4.2 54000 19.6 46300 3.9
Heating
EER
Capacity
(Btu/hr)
COP
Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump
Cooling
Capacity
(Btu/hr)
EER
Capacity (Btu/hr)
Heating
Cooling
Capacity
(Btu/hr)
COP
EER
Cooling
Capacity
(Btu/hr)
Heating
Capacity
(Btu/hr)
EER
COP
Heating
Capacity
(Btu/hr)
Engineering Submittal Sheet
Cooling Capacity (Btu/hr)
COP
EER
Cooling
Capacity
(Btu/hr)
EER
Heating
Capacity
(Btu/hr)
Heating
Capacity
(Btu/hr)
COP
COP
4 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Engineering Submittal Sheet
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Condenser Physical Data
Description Unit
Compressor Type (Qty 1)
Refrigeration Charge* Oz. 80 86 93 115 127
Max Water Working Pressure PSIG/kPa
Water Connection Size
FPT Swivel Connection Inch
Coaxial Coil Volume Gal
Cabinet
Weight - Operating (lbs)** lbs 172 172 172 237 237
Weight - Shipping (lbs)** lbs
SM024 SM036 SM048 SM060 SM070
Scroll Scroll Scroll Scroll Scroll
450/3100 450/3100 450/3100 450/3100 450/3100
1.0 1.0 1.0 1.0 1.0
0.33 0.62 0.62 1.07 1.07
189 189 189 261 261
Fan Coil Physical Data
Description Unit
ECM Const AirFlow -Eon Fan Motor & Blower
Fan Motor Type/Speeds
Fan Motor HP 0.33 0.50 0.75 1.00 1.00
Blower Wheel Size
Vertical Cabinet (AV)
Air Coil Dimensions (H x W)
Nominal size of Standard Filter - 2" MERV8
Weight - Operating (lbs)** lbs
Weight - Shipping (lbs)** lbs
Horizontal Cabinet (AH)
Air Coil Dimensions
Nominal size of Standard Filter - 2" MERV8
Weight - Operating (lbs)** lbs 124 143 180 207 228
Weight - Shipping (lbs)** lbs
* for 25 feet of line set
** This data refl ects standard unit weights only. Additional options may cause differences in
listed weights.
Inch
(Dia. x W)
Inch
(H x W)
Inch
(L x H)
Inch
(H x W)
Inch
(L x H)
SM024 SM036 SM048 SM060 SM070
ECM Const Air
Flow
9 X 7 9 X 7 10 X 8 11 X 9 12 X 9
24 X 21 24 X 21 24 X 27 24 X 27 32 x 27
24 X 24 (1) 24 X 24 (1) 24 X 30 (1) 24 X 30 (1) 16 X 30 (2)
124 143 180 207 228
152 175 220 253 279
18 X 28 18 X 28 20 X 32.5 20 X 32.5 20 X 43
20 X 30 (1) 20 X 30(1) 20 X 34 1/2 (1) 20 X 34 1/2 (1) 20 X 24 (2)
152 175 220 253 279
ECM Const Air
Flow
Value
Value
ECM Const Air
Flow
ECM Const Air
Flow
ECM Const Air
Flow
5 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Condenser Electrical Data
Engineering Submittal Sheet
Models Compressor
SM024 8733902168 1 208-230/1/60 197/253 1 11.7 58.3 14.6 25
SM036 8733902169 1 208-230/1/60 197/253 1 15.3 83.0 19.1 30
SM048 8733902170 1 208-230/1/60 197/253 1 21.2 104.0 26.5 45
SM060 8733902171 1 208-230/1/60 197/253 1 27.1 152.9 33.9 60
SM070 8733902172 1 208-230/1/60 197/253 1 29.7 179.2 37.1 60
Voltage
Code
Voltage/Phase/Hz
Voltage Min/
Max
Compressor Total Unit
QTY RLA LRA
Min Circuit
Amps
Fan Coil Electrical Data
Total Unit
Models Blower motor Voltage Code Voltage/Phase/Hz Voltage Min/Max QTY Motor FLA (A)
Min Circuit Amps Max Fuse/ HACR
SM024 8733805680 1 208-230/1/60 197/253 1 2.8 3.5 15
SM036 8733805681 1 208-230/1/60 197/253 1 4.3 5.4 15
SM048 8733805682 1 208-230/1/60 197/253 1 6.8 8.5 15
SM060 8733805683 1 208-230/1/60 197/253 1 9.1 11.4 20
SM070 8733805684 1 208-230/1/60 197/253 1 9.1 11.4 20
For units with Electric Heat Option - Constant CFM Variable Speed ECM all single circuit fused
Model
SM024 4.8 1 4,800 3,600 20.0 17.3 2.8 28.5 25.1 30 30
SM036 4.8 1 4,800 3,600 20.0 17.3 4.3 30.4 27.0 35 35
SM036 9.6 1 9,600 7,200 40.0 34.6 4.3 55.4 48.6 60 60
SM048 4.8 1 4,800 3,600 20.0 17.3 6.8 33.5 30.1 35 35
SM048 9.6 1 9,600 7,200 40.0 34.6 6.8 58.5 51.8 60 60
SM048 14.4 2 14400 10800 60 51.9 6.8 83.5 73.4 90 80
SM060 4.8 1 4,800 3,600 20.0 17.3 9.1 36.4 33.0 40 35
SM060 9.6 1 9,600 7,200 40.0 34.6 9.1 61.4 54.6 70 60
SM060 14.4 2 14400 10800 60 51.9 9.1 86.4 76.3 90 80
SM060 19.2 2 19200 14000 80 69.2 9.1 111.4 97.9 125 100
SM070 4.8 1 4,800 3,600 20.0 17.3 9.1 36.4 33.0 40 35
SM070 9.6 1 9,600 7,200 40.0 34.6 9.1 61.4 54.6 70 60
SM070 14.4 2 14400 10800 60 51.9 9.1
SM070 19.2 2 19200 14000 80 69.2 9.1
Electric Heater
Rated
kW
Stage
Heater
Watts
240V 208V 240V 208V 240V 208V 240V 208V
Heater
Amps
Motor FLA
(A)
MCA MOCP
86.4
111.4
76.3 90 80
97.9 125 100
Max Fuse/
HACR
6 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Condenser Dimensions and Connections
Engineering Submittal Sheet
7 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Fan Coil Horizontal Dimensions and Connections
Engineering Submittal Sheet
8 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
Fan Coil Vertical Dimensions and Connections
Engineering Submittal Sheet
9 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Engineering Submittal Sheet
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
SM024 Heating Performance Data - Full Load @ 900CFM
Water Temp
Entering
°F
30
40
50
60
70
80
Water
ow
GPM
3 1.9 0.8
4 3.2 1.4
6 6.6 2.9
3 1.8 0.8
4 3.1 1.3
6 6.4 2.8
3 1.8 0.8
4 3 1.3
6 6.1 2.6
3 1.7 0.7
4 2.9 1.3
6 5.9 2.6
3 1.6 0.7
4 2.8 1.2
6 5.7 2.5
3 1.6 0.7
4 2.7 1.2
6 5.5 2.4
Pressure
Drop
(FOH)
Pressure
Drop (PSI)
Ent. Air
db/wb, °F
60 16911 12302 1351 3.7 70 16800 11442 1485 3.3 80 16511 10495 1628 3.0 60 17464 12848 1359 3.8 70 17310 11954 1492 3.4 80 16978 10933 1635 3.0 60 18262 13446 1367 3.9 70 17849 12495 1501 3.5 80 17464 11543 1643 3.1 60 19093 14446 1384 4.0 70 18943 13557 1518 3.7 80 18723 12555 1662 3.3 60 19937 15162 1395 4.2 70 19503 14239 1530 3.7 80 19215 13240 1673 3.4 60 20766 15995 1408 4.3 70 20352 14923 1541 3.9 80 19928 13918 1685 3.5 60 22018 17322 1430 4.5 70 21597 16356 1565 4.0 80 21251 15292 1709 3.6 60 22964 18141 1443 4.7 70 22388 17131 1578 4.2 80 21971 15986 1722 3.7 60 23975 18993 1458 4.8 70 23274 18010 1593 4.3 80 22793 16757 1736 3.9 60 24767 19968 1473 4.9 70 24260 18983 1609 4.4 80 23851 17817 1755 4.0 60 25912 20876 1489 5.1 70 25209 19919 1625 4.5 80 24667 18796 1772 4.1 60 27075 22003 1508 5.3 70 26436 20800 1642 4.7 80 25835 19596 1789 4.2 60 27631 22790 1519 5.3 70 27216 21564 1655 4.8 80 26519 20590 1805 4.3 60 28968 23825 1537 5.5 70 28333 22644 1673 5.0 80 27739 21438 1822 4.5 60 30379 25157 1559 5.7 70 29593 23864 1694 5.1 80 28897 22553 1842 4.6 60 30791 25562 1565 5.8 70 29957 24553 1703 5.2 80 29534 23175 1853 4.7 60 32207 26935 1584 6.0 70 31392 25627 1723 5.3 80 30725 24326 1873 4.8 60 33755 28559 1603 6.2 70 32916 27095 1739 5.5 80 32082 25640 1893 5.0
Total
Btu/hr.
Ht. Abs.
Btu/hr.
Unit
kW
COP
10 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Engineering Submittal Sheet
CDi Series Model SM - Split System
Residential Geothermal Heat Pumps
SM024 Heating Performance Data - Par tial Load @ 600CFM
Water Temp
Entering
°F
30
40
50
60
70
80
Water
ow
GPM
3 1.9 0.8
4 3.2 1.4
6 6.6 2.9
3 1.8 0.8
4 3.1 1.3
6 6.4 2.8
3 1.8 0.8
4 3 1.3
6 6.1 2.6
3 1.7 0.7
4 2.9 1.3
6 5.9 2.6
3 1.6 0.7
4 2.8 1.2
6 5.7 2.5
3 1.6 0.7
4 2.7 1.2
6 5.5 2.4
Pressure
Drop
(FOH)
Pressure
Drop (PSI)
Ent. Air
db/wb, °F
60 11921 8450 1012 3.5 70 11892 7765 1143 3.1 80 11625 7030 1280 2.7 60 12526 8902 1015 3.6 70 12210 8146 1144 3.1 80 11917 7366 1281 2.7 60 12967 9391 1018 3.7 70 12575 8562 1145 3.2 80 12256 7741 1282 2.8 60 13981 10304 1023 4.0 70 13534 9512 1148 3.5 80 13297 8801 1283 3.0 60 14602 11163 1026 4.2 70 14015 10014 1151 3.6 80 13830 9224 1287 3.2 60 14951 11437 1028 4.3 70 14469 10665 1154 3.7 80 14219 9744 1288 3.2 60 16029 12638 1032 4.6 70 15723 11740 1157 4.0 80 15513 11044 1294 3.5 60 16666 13324 1034 4.7 70 16345 12405 1158 4.1 80 16024 11513 1296 3.6 60 17365 13929 1035 4.9 70 16925 13025 1159 4.3 80 16561 12060 1298 3.7 60 18768 15524 1039 5.3 70 17772 13452 1160 4.5 80 18052 13535 1303 4.1 60 18959 15635 1039 5.3 70 18498 14658 1162 4.7 80 18119 13589 1303 4.1 60 19665 16341 1039 5.5 70 19091 15352 1164 4.8 80 18740 14340 1305 4.2 60 21214 18287 1042 6.0 70 19532 15558 1167 4.9 80 19731 14651 1306 4.4 60 21721 18347 1040 6.1 70 20757 17069 1168 5.2 80 20272 15710 1309 4.5 60 22132 18847 1040 6.2 70 21496 17732 1168 5.4 80 21016 16640 1310 4.7 60 21935 20052 1045 6.2 70 21855 17854 1168 5.5 80 22013 17724 1313 4.9 60 22863 18866 1037 6.5 70 23304 19772 1168 5.9 80 21525 18464 1282 4.9 60 24507 20832 1033 7.0 70 23833 20011 1167 6.0 80 23322 18979 1321 5.2
Total
Btu/hr.
Ht. Abs.
Btu/hr.
Unit
kW
COP
11 of 36
Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances |
BTC 760108304 B | 05.2017
Bosch Thermotechnology Corp.
Londonderry, NH • Ft. Lauderdale, FL
Tel: 1-866-642-3198 Fax: 1-954-776-5529 www.boschheatingandcooling.com
Loading...
+ 25 hidden pages